research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Study the effect of Gaussian Filter on Image of point Object for Optical System Using Different Apertures
دراسة تأثير المرشح الكاوسي على صورة جسم نقطي لنظام بصري باستخدام فتحات مختلفة

Author: رجاء عبد الأمير مدلول
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2010 Volume: 8 Issue: 2 Pages: 88-100
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

In this research , the effect of Gaussian spatial filter which has coefficient of normative deviation (a) in different value (a=0.25,0.5,0.75,1) has been studied on point spread function )PSF (whereas the equation of )PSF (which contain the term which represent the gausian filter has been derived for the ideal optical system or contain focus error (W20=0.25λ,0.5λ), the results have been showed that the lower value of coefficient of normative deviation for Gaussian spatial filter leads to increase the intensity in the formed image and the reduced the effect of aberrations on the distribution of the intensity in the image plane , also the effect of aperture shape has been studied on the formed image for the system contains Gaussian spatial filter, the aperture is used in different shapes (square, rectangle (vertical and horizontal)),the results showed that the rectangle horizontal aperture give the best resolution from the other at the perfect system and best distribution of intensity in the image plane at system contain focus error (W20=0.25λ,W20=0. 5λ) from the other.

تم في هذا البحث دراسة تأثير المرشح الكاوسي ذي معامل الانحراف المعياري (a) لقيم مختلفة منه (0.25,0.5,0.75,1=a) على دالة الانتشار النقطية (PSF) حيث تم اشتقاق معادلة الانتشار النقطية التي تحتوي الحد الذي يمثل المرشح الكاوسي لنظام بصري مثالي أو يحتوي على خطأ بؤري مقداره ( W20=0.25λ,0.5λ) , وقد بينت النتائج إن القيم الدنيا من معامل الانحراف المعياري للمرشح الكاوسي تؤدي إلى زيادة الشدة في الصورة المتكونة وتقلل من تأثير الزيوغ على توزيع الشدة في مستوى الصورة , أيضا تم دراسة تأثير شكل الفتحة على الصورة المتكونة لنظام بصري يحتوي على مرشح كاوسي , وقد اعتمدت الفتحات (المربعة,المستطيلة(العمودية والأفقية)) , وأعطت الفتحة المستطيلة الأفقية صورة هي الأفضل من حيث قدرة التحليل في النظام المثالي وكذلك الافضل لتوزيع الشدة في النظام الذي يحتوي على خطأ بؤري W20=0.25λ, 0.5λ)) من الفتحات الأخرى.

Keywords


Article
Study the effect of the Aperture on Cassegrain Telescopes
دراسة تأثير فتحة الإدخال على التلسكوب الكاسكريني

Authors: رجاء عبد الأمير مدلول --- مروه جواد حزام الجبوري
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2014 Volume: 12 Issue: 3 Pages: 60-74
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

In this research study the effect of (Aperture) on some of the parameters that control the visual quality of the image formed by Cassegrain telescope for the purpose of evaluate the performance of this telescope that study (RMS) Root Mean Square.The form of the distribution of the rays Encircled Energy (Enc) and A spherical Aberration is one of the most important factors affecting the composition of the image in the telescope and by which they can evaluate the work of the telescope. I have been studying these parameters through the use of program Zemax where the results showed that an increase in Aperture lead to increased A spherical Aberration in the image or visual system also leads at the same time to increase the area of the bright spot (RMS).The Encircled Energy they increase less Aperture System spherical and non-spherical system increases and this evidence quality optical design for the case study of this topic telescope Cassegrain.

تم في هذا البحث دراسة تأثير فتحة الإدخال (Aperture)على بعض المعلمات البصرية التي تتحكم بجودة الصورة المتكونة بواسطة التلسكوب الكاسكريني لغرض تقيم أداء هذا التلسكوب إن دراسة مساحة البقعة المضيئة (RMS) Root Mean Square وشكل توزيع الأشعة فيها وكمية الطاقة المتجمعة Encircled Energy (Enc) والزيغ الكروي spherical Aberration تعتبر من أهم العوامل المؤثرة على تكوين الصورة في إي تلسكوب والتي من خلالها يمكن تقيم عمل التلسكوب ولقد تم دراسة هذه المعلمات من خلال استخدام برنامج Zemaxحيث أظهرت النتائج أن زيادة فتحة الإدخال يؤدي إلى زيادة الزيغ الكروي في الصورة (أو المنظومة البصرية)، كذلك يؤدي في نفس الوقت إلى زيادة مساحة البقعة المضيئة (RMS)، أما الطاقة المتجمعة فإنها تقل بزيادة فتحة الإدخال للمركبة اللاكروية وتزداد للمركبات الكروية وهذا دليل جودة التصميم البصري لهذه الحالة المدروسة للتلسكوب الكاسكريني.

Keywords


Article
Thermal Modeling for Studying Optical System Using Zemax Program
أنموذج حراري لدراسة الأنظمة البصرية باستخدام برنامج زيماكس

Authors: فاضل خدام فليفل --- رجاء عبد الأمير مدلول --- إيمان إبراهيم عوض --- رحيم كعيد كاظم
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2012 Volume: 10 Issue: 3 Pages: 195-202
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The thermal properties of lenses play an important role in the performance of optical systems. The effects of temperature changes on lens performance are discussed. The comparison between the output results using Zemax and the results obtained from the analytical solution of the equations using by the researchers are performed for describing the change of focal length and the radius of spot energy as a function of temperature depending on the prescription output data from Zemax program for optical glass types using in manufacture process which is contained the following types SK16,SK11 ,F2 , K7 .

تلعب الخواص البصرية للعدسات دورا مهما في تحديد كفاءة الأنظمة البصرية ,في هذا البحث تم مناقشة تأثيرات التغير في درجات الحرارة والطول ألموجي على كفاءة العدسات ومقارنة النتائج المخرجة باستخدام برنامج زيماكس مع النتائج التي تم حسابها بالاعتماد على مجموعة من المعادلات المستخدمة من قبل الباحثين لوصف تغير البعد البؤري ونصف قطر بقعة الطاقة كدالة لدرجة الحرارة بالاستفادة من المعلومات الوصفية المخرجة من برنامج زيماكس لأنواع الزجاج البصري المستخدم . SK16,SK11,F2,K7 في عملية التصنيع الذي تضمن الأنواع التالية

Keywords

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

Arabic (2)

English (1)


Year
From To Submit

2014 (1)

2012 (1)

2010 (1)