research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
The evaluation of heavy metals pollution in agricultural lands in Jisser Diyala district
تقييم التلوث بالعناصر الثقيلة في الاراضي الزراعية الواقعة في منطقة جسر ديالى

Loading...
Loading...
Abstract

plants grown in contaminated site can expose consumers health to danger, this research was done to evaluate the contamination with heavy metals in part of Diyala River, soil, plants in agricultural lands located on the both side of the Diyala River and irrigated from this river, 12 samples of irrigation water, 12 samples of soil and another 12 samples of plants like celery, radish. malt and clovers were taken and analyzed to find the concentration of some heavy metals Pb, Zn, Ni, Cd, Cr, Mn and Cu, results show that the average concentration of Cd in irrigation water was 0.0215 mg/l and more than the acceptable level for WHO, while the average concentration of Ni in soil was 109.87 mg/kg which is more than WHO limit, on the other hand most of these heavy metals concentration in the surface layer of soil were more than their concentrations in the below layers, this lead to say metals can move and translate through the layers of soil, results for plants show that the average concentration of Pb in all samples was more than WHO limit, it was 1.85, 1.8, 1.375 and 1.04 mg/kg in celery, radish, malt and clovers respectively, therefore the increasing of consumption for this contaminated plants by community could cause health problems in the future.

إن نمو النباتات في مواقع ملوثة قد يعرض صحة المستهلك للخطر، لذلك أنجز هذا البحث لتقييم التلوث بالعناصر الثقيلة في جزء من مياه نهر ديالى وفي التربة والنباتات للاراضي الزراعية الواقعة على جانبي النهر في منطقة جسر ديالى والتي تستخدم مياه النهر لاغراض الري، اذ تم اخذ 12 أنموذجاً من مياه النهر فضلا عن 12 أنموذجاً من التربة و12 أنموذجاً اخرى من النباتات مثل الكرفس والفجل والشعير والبرسيم الواقعة ضمن منطقة الدراسة وتم تحليل هذه النماذج لايجاد تراكيز بعض العناصر الثقيلة مثل الرصاص والزنك والنيكل والكادميوم والكروم والمنغنيز والنحاس، وبينت نتائج البحث ارتفاع تركيز الكادميوم في مياه النهر حيث كان معدل تركيزه 0.0215 ملغم/لتر وبهذا يتجاوز الحد المسموح به لمنظمة الصحة العالمية لمياه الري، أما في التربة فقد كان معدل تركيز النيكل 109.87 ملغم/كغم متجاوزا بذلك محددات منظمة الصحة العالمية، ومن الناحية الاخرى كان معدل تراكيز اغلب العناصر للطبقة السطحية من التربة اعلى من تراكيزها للطبقات الاخرى مما يشير الى وجود حركة وانتقال لهذه العناصر خلال طبقات التربة، وفيما يخص نتائج النباتات فقد كان تركيز الرصاص مرتفعا في اغلب النماذج عن الحد المسموح به حيث بلغ 1.04,1.375,1.8,1.85 ملغم/كغم لكل من الكرفس والفجل والشعير والبرسيم وعلى التوالي، لذلك فأن زيادة الاستهلاك من هذه النباتات الملوثة من قبل المجتمع قد يسبب مشاكل صحية في المستقبل.

Keywords


Article
أيجاد موديل رياضي لتقييم أداء محطة تصفية مياه الشرب ومصدر تجهيزها بالماء الخام

Authors: رياض حسن الانباري --- جواد كاظم عبود الرفاعي --- رعد هاشم منصور الطالقاني
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2007 Volume: 5 Issue: 1 Pages: 87-95
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

In this research an experiment work was done to study and analysis the physical, chemical, and Biological data for (1) the raw water that entering the Mussaib Tech. Institute treatment plant from the main source (M.M. Canal). (2) Raw water on the stream line of the Canal for 15 Km distance from the upstream in the North of Mussaib city, in (7) stations on the line stream (2.5 Km) between each fallowing two stations in the studying period from 1/3/2005 to 31/8/2005 (3) the settled and treated water without using any coagulants in the same period in the first item. (4) with this period also for settled and treated water with using alum as coagulant. The results was discussed and the figures show the limitation of the plant performance and the validity or the suitability of the Canal raw water according to the Iraqi standards of the drinking water. The results illustrated than the max. value of the turbidity in the Canal in a year not reach 30 NTU, the settling tank efficiency is not good because of the accumulated collected sludge reaches (3m) from the height (8.5m) after (6) months for bad existing hydraulic disposal system. There is well filter performance. The observed canal data illustrate that all the variables are under the Iraqi standards guide line for raw water unless the variable (NO2-), and the agriculture areas that the canal flows through it, effect on the canal water characteristics. The observed data was Analyzed statistically with [SPSS 7.5 windows 98] to determine the correlation matrix, Descriptive statistical, and the Regression relationship. The result is in the acceptable degree and in the degree of significant level for the mentioned-items-are:1-Intake Raw W., [ Turb.(NTU) =22.38 – 0.919 TSS (mg/L )], R2 = 0.919 2- a- settled W. Without [ Trub. (NTU) = 35.348-0.742 SO4(mg/L)-0.45Mg(mg/L)], R2 = 0.933b- treated W. Without., [Turb.(NTU)=-1.907+0.833 TSS(mg/L)+0.584 Temp. °C ] , R2 = 0.893 3-a- settled W. With., [Trub.(NTU)=12.976-0.929 TSS (mg/L)], R2=0.929b- treated W. With., [Trub.(NTU)=-4.182-0764 TSS(mg/L)] R2=0.764.

تم في هذا البحث اجراء دراسة عملية لتحليل البيانات المتعلقة بالخواص الفيزيائية والكيميائية والبايولوجية (1) للماء الخام الداخل من المصدر الرئيسي (قناة مشروع المسيب) لتجهيز محطة تصفية المعهد التقني المسيب لمدة (10) أشهر للفترة من 1/5/2004 الى 28/2/2005 (2) ماء خام المصدر على طول مسار القناة والى المسافة (15) كم من المصب من شمال مدينة المسيب وبواقع (7) مواقع على المسار (كل 2.5 كم ما بين موقع واخر) للفترة من 1/3/2005 ولغلية 31/8/2005. (3) المياه المرسبة والمياه المعالجة (بعد عملية الترشيح واضافة المعقمات) بدون استخدام مخثرات للتلبيد ضمن نفس الفترة في الفقرة الاولى. (4) المياه المرسبة والمياه المعالجة بعد استخدام المخثر (الشب) في التلبيد بنفس الفترة ايضاً المذكورة في الفقرة الاولى. تم مناقشة النتائج والمخططات لتحديد كفاءة تشغيل المحطة وكذلك تحديد صلاحية المصدر لاستخدامه في تصفية مياه الشرب وحسب المواصفات العراقية لتحديد خواص مياه الشرب والاستخدامات المختلفة. تبين ان اقصى عكارة تحملها القناة على مدى سنة كاملة لاتتجاوز 30 NTU وكذلك تبين عدم كفاءة حوض الترسيب الوحيد لازالة الاطيان بسبب ضعف كفاءة الطريقة الهيدرولكية لسحب الاطيان بحيث تتجمع في قعر الحوض لارتفاع (3m) من اصل (8.5m) بعد ستة اشهر. تبين ان حوض الترشيح يعمل بصورة مقبولة. من خلال دراسة البيانات الخاصة بالمصدر (قناة مشروع المسيب) تبين ان متغيرات خواص الماء الخام للقناة كانت ضمن المواصفات العراقية بأستثناء المتغير (NO2). كذلك تبين ان الاراضي الزراعية التي تمر خلالها القناة تؤثر من خلال الرشح على النهر وكذلك البزل القاطع للقناة بعد مسافة 2.5 كم من المصب. تم تحليل كافة النتائج أحصائياً بنظام ] SPSS 7.5 windows 98 [ لايجاد معاملات الارتباط لبيان قوة الارتباط ما بين المتغيرات فيما بينها وايجاد المعادلات (الموديلات الرياضية) لخواص المياه في الحالات الاربعة حسب تاثيرها بأعتماد العكارة كمتغير مستقل وايجاد قوة الارتباط وبمستوى دلالة %5 فكانت جميعها ضمن مستوى الدلالة وهذه المعادلات حسب تسلسلها في اعلاه :

Keywords


Article
Biodegradation of organic content via activated sludge seeding coupled with aeration in simulated self-purification sewer system
التحلل البايولوحي للملوثات العضوية بواسطة الاطيان المنشطة المعززة بالتهوية في منظومة محاكاة للمجاري ذاتية التنقية

Loading...
Loading...
Abstract

Partial degradation of organic materials presented in sewage water had been conducted in the current research in a simulated sewer system. The process had been improved by aeration and seeding with activated sludge to reveal the effect of increasing the amount of biomass in the system. Three ambient temperatures were conducted as 10, 20, and 30 OC to display the influence of temperature on the degradation process. The results revealed that adding activated sludge to the system in a ratio of 50/50 (v/v) had a significant influence on the degradation as more microorganisms required more organic nutrients. In the other hand, increasing the operating temperature indicated positive influence in terms of soluble chemical oxygen demand (SCOD) removal as temperature motivated the living biomass towards severe degradation.

تم في هذا البحث دراسة التحلل الجزئي للمواد العضوية الموجودة في مياه المجاري بواسطة منظومة محاكاة لنظام التصريف. تم تعزيز النظام بالتهوية المستمرة والاطيان المنشطة لمعرفة تأثير زيادة كمية الاحياء المجهرية الموجودة في النظام. تم اختبار النظام تحت ثلاثة درجات حرارة محيطية 10, 20, و 30 درجة مئوية لمعرفة تأثير درجات الحرارة على عملية التحلل. اظهرت النتائج ان اضافة الاطيان المنشطة بنسبة 50 /50 (حجم / حجم) ادت الى تأثير ايجابي على التحلل حيث ان ازدياد كمية الاحياء المجهرية تتطلب ازدياد في المواد العضوية المتحللة. من جانب اخر, ادت زيادة درجة الحرارة المحيطية الى ازدياد ايجابي في ازالة الاوكسجين المتطلب كيمياويا حيث تؤدي زيادة درجة الحرارة الى زيادة نشاط الاحياء المجهرية مؤدية الى زيادة في تحلل المواد العضوية.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

Arabic (2)

Arabic and English (1)


Year
From To Submit

2018 (1)

2010 (1)

2007 (1)