research centers


Search results: Found 12

Listing 1 - 10 of 12 << page
of 2
>>
Sort by

Article
Study Heavy Metal Concentrations In Drinking Water In Ad Dīwānīyah City
دراسة تركيز العناصر الثقيلة في مياه الشرب في محافظة الديوانية

Author: علي هادي غاوي
Journal: Muthanna Journal of Engineering and Technology(MJET) مجلة المثنى للهندسة والتكنولوجيا ISSN: 25720317 25720325 Year: 2017 Volume: 5 Issue: 2 Pages: 40-44
Publisher: Al-Muthanna University جامعة المثنى

Loading...
Loading...
Abstract

Countries with high population density such as Iraq, are facing many health problems caused by pollution resulting from population activities on the different components of the environment burden which is the most dangerous of these pollutants are heavy metals in the waters of rivers, and that most of the water treatment plants where there is no chemical treatment to remove heavy elements stage. This project aims to find out the concentration of toxic heavy metals and cancer-causing disease in humans in the case of non-processed. Where the study of concentration of heavy metals in the three water treatment plants in Diwaniya city first in the north of the province of Diwaniya (Diwaniya large project, "Project No. 6") and in the center (water treatment plant in Aljazaer) and the South of Diwaniya city (water treatment plant in Aleskan). The aim of the selection of three sites to demonstrate the impact of the discharge of sewage from the city on the sites of three drinking water treatment plants. Heavy elements that have been studied in this research are (nickel, cadmium, aluminum, mercury and lead) for three drinking water treatment plants, and for five stages which were (the intake (the river), sedimentation, after filtration, the ground reservoir, and the water network). These stages were identified to indicate the effect of the treatment stages on the concentration of these elements in terms of increase or decrease. The results of the study showed high concentrations of both the aluminum and lead which were above the permissible limits of the standard Iraqi standard, where concentrations of the lead were high for all stages of treatment. The results of the study showed that the concentration of the aluminum is more than the permissible limits in all stages of drinking water treatment due to adding alum to the rapid mixing tank. Concentrations of the remaining heavy metals (nickel, cadmium and mercury) were few or nil and were within the limits of Iraqi standards.

تواجه البلاد ذات الكثافة السكانية العالية مثل العراق العديد من المشكلات الصحية التي يسببها عبء التلوث الناتج عن الأنشطة السكانية على مكونات البيئة المختلفة, ومن اخطر هذه الملوثات هي العناصر الثقيلة في مياه الانهار, وان معظم محطات تصفية المياه لا يوجد فيها مرحلة معالجة كيمياوية لإزالة العناصر الثقيلة. تهدف هذه الدراسة الى قياس تراكيز العناصر الثقيلة السامة في مياه الشرب في محافظة الديوانية والتي تسبب امراض السرطان لدى الانسان. حيث تم دراسة تركيز العناصر الثقيلة في ثلاث محطات لتصفية المياه في محافظة الديوانية من شمال المدينة (مشروع الديوانية الكبير "مشروع رقم 6") ووفي وسط المدينة (مجمع ماء الجزائر) وفي جنوب المدينة (مجمع ماء الاسكان). والهدف من اختيار ثلاث مواقع لبيان تأثير طرح مياة الصرف الصحي من المدينة على مواقع وحدات تصفية مياة الشرب الثلاثة. والعناصر الثقيلة التي تم دراستها في هذا البحث هي (النيكل ,الكادميوم ,الالمنيوم ,الزئبق و الرصاص) لكل محطة من محطات المعالجة الثلاث و لخمس مراحل (المأخذ (النهر), حوض الترسيب, بعد الفلتر, الخزان الارضي, ونموذج من ماء الشبكة الواصل للمنازل). وحددت هذه المراحل لبيان تأثير مراحل التصفية على تركيز هذه العناصر من حيث الزيادة او النقصان وجودها من عدمة. وبينت نتائج الدراسة وجود تراكيز عالية لكل من عنصري الالمنيوم والرصاص فوق الحدود المسموحة للمواصفة العراقية القياسية, حيث كانت تراكيز عنصر الرصاص عالية لكل مراحل التصفية. وبينت نتائج الدراسة ان تركيز عنصر الالمنيوم اكثر من الحدود المسموحة في جميع مراحل معالجة مياة الشرب بسبب اضافة الشب لحوض المزج. اما تراكيز بقية العناصر الثقيلة وهي (النيكل ,الكادميوم والزئبق) فكانت قليلة او معدومة وتقع ضمن حدود المواصفات القياسية العراقية.


Article
Investigation Of An Improved Performance Of Secondary Clarifiers Using Computational Fluid Dynamics Model
فحص الاداء المحسن للمصفيات الثانوية بأستخدام النموذج الحسابي لديناميك الموائع

Author: Ali H. GHAWI علي هادي غاوي
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2011 Volume: 15 Issue: 1 Pages: 82-100
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Secondary clarifier is one of the most commonly used unit operations in wastewater treatment plants. It is customary designed to achieve solids separation from biologically treated effluent through clarification of biological solids and thickening of sludge. As treatment plants receive increasingly high wastewater flow, conventional sedimentation tanks suffer from overloading problems which result in poor performance. Inlet baffle modification by using an energy dissipating inlet (EDI) was proposed to enhance the performance in the circular clarifiers in Al-Dewanyia wastewater treatment plant. A 3-Dimensional fully mass conservative clarifier model, based on modern computational fluid dynamic theory, was applied to evaluate the proposed tank modification and to estimate the maximum capacity of the existing and modified clarifiers. A Computational Fluid Dynamic (CFD) model was formulated to describe tank performance and design parameters were obtained based on the experimental results. The study revealed that velocity and SS is a better parameter than TS, BOD, COD to evaluate the performance of sedimentation tanks, and Removal efficiencies of suspended solids, biochemical oxygen demand, and chemical oxygen demand were higher in the EDI (Baffle).

ان أحواض الترسيب الثانوية واحدة من أكثر وحدات المعالجة أهمية في محطات معالجة مياه الصرف الصحي. ان أحواض الترسيب مصممة لإزالة المواد الصلبة و المواد العضوية الناتجة من المعالجة الحيوية في أحواض التهوية حيث تتجمع هذه المواد و تترسب قي قعر حوض الترسيب على شكل خبث. نتيجة لزيادة كميات التصريف الواصلة الى محطات المعالجة نتيجة للنمو السكاني أصبحت أحواض الترسيب الكلاسيكية تعاني من قلة كفاءتها في المعالجة. لذلك يتطلب الأمر تحسين أداء هزة الأحواض, حيث تم في هزة الدراسة إضافة مصدات عند مدخل مياه الصرف الصحي الى حوض الترسيب لغرض تحسين الأداء لهذه الأحواض, حيث تم تطبيق هذا التحسين في محطة معالجة مياه الصرف الصحي في مدينة الديوانية و التي تعاني من زيادة كمية المياه المتدفقة و بالتالي قلة كفاءة المعالجة. في هذه الدراسة تم تطوير نموذج رياضي ثلاثي الإبعاد بناء على حفظ الكتلة لغرض نمذجه أحواض الترسيب و بالتالي تحسين أداءها و زيادة سعتها. و شملت الدراسة قياسات مختبريه للمواد العضوية و الصلبة و الكيماوية لغرض تحسين أداء محطة المعالجة. و قد بينت النتائج ان كفاءة أحواض الترسيب و بالتالي كفاءة محطة المعالجة تزداد باستخدام المصدات و كذلك سعتها. و ان الدراسة قد كشفت ان سرعة الجريان و تركيز المواد الصلبة هو أفضل مؤشر لتحسين أداء أحواض الترسيب.

Keywords

Clarifier --- Sedimentation --- Sludge --- Wastewater --- Solids --- CFD.


Article
PERFORMANCE IMPROVEMENT OF CONVENTIONAL AERATION TANKS USING CFD MODELING
تحسين أداء أحواض التهوية في محطات معالجة مياه الصرف الصحي باستخدام نموذج ديناميكا السوائل الحسابية

Author: Ali H. Ghawi علي هادي غاوي
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2011 Volume: 3 Issue: 1 Pages: 1-17
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

The hydraulic design of wastewater treatment plants (WWTP) is usually based on general guidelines and experience. Research and development in this field is mainly focused on understanding and improvement of the biological processes. However, hydraulic design is an important factor in the performance of a wastewater treatment plant. The aeration tank is a process-step where hydraulic and biological behavior are both important for overall performance. In this study a general Computational Fluid Dynamic (CFD) model is developed to characterize the flow field and improvement performance in conventional aeration tank in Al-Dewanyia Wastewater Treatment Plant in Al-Dewanyia city. A local Residence Time Distribution (RTD) model is developed to predict a resident time in the aeration tank based on converged flow fields. Furthermore, a Biological Oxygen Demand (BOD) model is incorporated to simulate BOD removal in the aeration tank. A number of operational scenarios are evaluated using CFD. These calculations provide useful information for the assessment of risks on short-circuit flows and sedimentation. The CFD results are compared with measurements and show good agreement. The gained insight in the hydraulic design improves the operation of the wastewater treatment plants and reduces energy and maintenance costs.

ان التصميم الهيدروليكي لمحطات معالجة مياه الصرف الصحي تعتمد على المحددات التصميمية و الخبرة العملية للمصمم. البحوث والتطوير في مجال تصميم محطات معالجة مياه الصرف الصحي يعتمد بشكل رئيسي على فهم وتحسينِ العمليات الحيوية في وحدات المعالجة. على أية حال التصميم الهيدروليكي عامل مهمُ في تقييم أداءِ محطات معالجة مياه الصرف الصحي. و يعتبر حوض التهوية في محطات معالجة مياه الصرف الصحي والذي يشمل السلوك الهيدروليكي و الحيوي احد أهم مراحل المعالجة التي يمكن ان تقيم بواسطة أداء محطات معالجة مياه الصرف الصحي. في هذا البحث تم تطوير موديل رياضي عام باستخدام نموذج ديناميكا السوائل الحسابية CFD لمعرفة خواص الجريان و تحسين أداء محطات معالجة مياه الصرف عن طريق تحسين أداء حوض التهوية في محطة معالجة مياه الصرف الصحي في مدينة الديوانية. كذلك تم تطوير نموذج RTD للتنبؤ بزمن بقاء مياه الصرف الصحي في حوض التهوية بالاعتماد على معرفة سلوك الجريان. وتم إضافة نموذج المتطلب الحيوي للأوكسجين BOD الى النموذج الرياضي الذي طور في هذه الدراسة لغرض تمثيل إزالة المتطلب الحيوي للأوكسجين في حوض التهوية. تم تطبيق عدد مِنْ السيناريوهات لنموذج ديناميكا السوائل الحسابية في هذه الدراسة. ان النتائج التي تم الحصول عليها من هذه الدراسة تعتبر مفيدة جدا لمعرفة تأثير حصول الترسيب و الدوامات القصيرة على أداء حوض التهوية. تم مقارنة النتائج الناتجة من النموذج الرياضي و الناتج من القياسات حيث كانت النتيجة تطابق جيد بين النتائج و القياسات. ان هذه الدراسة أثبتت التصميم الهيدروليكي يحسن أداء تشغيل محطات المعالجة و يقلل كلف الصيانة و الطاقة.


Article
A COMPUTATION FLUID DYNAMIC INVESTIGATION INTO THE USE OF BAFFLES IN POTABLE WATER TREATMENT PLANT PROCESS TANKS IN IRAQ
تحقيق ديناميِكية حسابِ المائعِ في استعمال ِالحواجز في أحواضِ محطات معالجةِ الماءِ الصالح للشرب في العراق

Author: ALI H. GHAWI د. علي هادي غاوي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2009 Volume: 2 Issue: 2 Pages: 94-107
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The reaction that takes place in a process tank is in a large way dependent on the internal hydraulics of the tank, irrespective of the type of tank. In some tanks mixing is desirable in others plug flow is desirable. In most tanks it is very hard to achieve either of the two. This is partially due to the fact that the area through which the fluid enters the tank is small in relation to the tank cross sectional, complex geometries and changes of fluid direction. Baffles can in some cases offer cost effective and simple solutions. This paper demonstrates how Computation Fluid Dynamic (CFD) can be used to improve process tanks performance in Iraq water treatment plant by the introduction of baffles.

التفاعل الذي يَحْدثُ في أحواض معالجة مياه الشرب عَلى نَحوٍ كبير معتمدة على الهيدروليكية الداخلية للأحواض، بصرف النّظر عن نوعِ الحوضِ. في بَعْض الأحواض تكون عملية الجريان الممزوج مرغوبة و البعض الأخر تكون عملية الجريان المتدفقِِ مرغوبُة. في أكثر الأحواض من الصعب جداً ان يحصل الاثنان معا". هذهً الحقيقة بسبب إن منطقة دخول المائع إلى الحوض صغيرة بالنسبة إلى مساحة الحوض, الشكل المعقدة للحوض و التغير في اتجاه الجريان . المصدات لها القدرة على تقلل كلفة معالجة الماء الصالح للشرب في محطات المعالجة و كذلك توفر حلول سهلة و بسيطة في عملية المعالجة و لمختلف أحواض المعالجةِ. هذه الدراسة أثبتت كيفية ان ديناميكية حساب المائع (CFD) يمكن أن تُستَعملَ لتحسّينُ أداءُ الأحواض المستخدمة في محطات معالجة مياه الشرب في العراق و بتالي الحصول على نوعية مطابقة للمواصفات العالمية لنوعية الماء الصالح للشرب باستخدام المصدات.


Article
STUDY OF THE EFFECT OF FERRIC CHLORIDE CONCENTRATIONS AND pH ON ORGANIC MATTAR REMOVAL PERCENTAGE IN AL-DEWANYIA WATER TREATMENT PLANT
دراسة تأثير كلوريد الحديديك والاس الهيدروجيني على نسبة الازالة للمواد العضوية في محطة معالجة مياه الشرب في الديوانية

Author: Ali H. Ghawi علي هادي غاوي
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2011 Volume: 11 Issue: 1 Pages: 135-146
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Supplying drinking water in Al-Dewanyia city to meet Iraqi Drinking Water Guidelines is a challenge as source waters contain high concentrations of Natural Organic Matter (NOM) that often exceed 12 mg/L Dissolved Organic Carbon (DOC). The US EPA indicates that enhanced coagulation is the best available technology to control DOC in drinking water treatment plants. A water director of Al-Qadissiya has used enhanced coagulation at Al-Dewanyia Water Treatment Plants (WTP’s) in Iraq since 2004 to improve water quality in the distribution system. NOM reduction has led to treated water with a lower chlorine demand allowing a greater residual penetration enabling improved bacteriological compliance. Since the cost of DOC (and Disinfection by-product DBPs) determination was high, it was decided to study the traditional analysis of COD as a surrogate measure to detect the organic constituents in raw water and the extent to which optimized coagulation with ferric chloride can increase COD removal. The water samples studied belonged to Al-Dewanyia River. For samples the observed values of COD removal by coagulation at lower pH (about 1-1.5 pH values less than the regular pH (5.8 ~ 8.5)) were about 85-95 percent without making water turbidity unacceptable. In order to determine the effects of organic content on coagulation, The results indicated that a modified coagulation process without need to much increasing the amount of coagulant can be developed for these water samples

Keywords

Water Quality --- WTP --- DOC --- COD --- NOM


Article
APPLICATION OF ADVANCED OXIDATION PROCESS FOR REDUCING THE VOLUME OF AN AERATION TANK OF A CONVENTIONAL WASTEWATER TREATMENT PLANT
تطبيق عملية الاكسدة المتقدمة في اختزال حجم احواض الاكسدة الهوائية لمحطة معالجة مياه ثقيلة تقليدية

Authors: عامر دحام زماط --- علي هادي غاوي
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2011 Volume: 9 Issue: 3 Pages: 60-69
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

Iraqi government is actively promoting wastewater reclamation because of urgent water needs. Wastewater reuse is governed by stringent regulations to protect public health against waterborne diseases and any other adverse environmental effects. This study is aimed at determining the type and level of advanced treatment needed for effective treatment of 60000 m3.day-1 domestic wastewater of an Iraqi city without major modification of plant layout. An urgent request by the Iraqi government to implement nutrients and phosphorous removal units for an under construction project. Extensive investigations were carried out to size and add both Phosphorus & Nitrogen (P & N) removal units into the plant layout. Due to limitation of site land, it was found itself obliged to work on redesigning the aeration basin of the WWTP. The aeration basin consists of eight cells of (25x25x5) m3volume. The redesign approach adopted here involved two main objectives; one objective is to utilize part of the aeration basin as Phosphorus & Nitrogen (P & N) removal units while the second objective is to raise the efficiency of the aeration basin to handle the original influent with the remaining cells to deliver the standard effluent specifications. A cost effective study was carried out to use Advanced Oxidation Process (AOP) based on Fenton's process to achieve both objectives mentioned above. Fenton's process using H2O2 to react with wastewater in the presence of Fe++ prior to the aeration tank resulted in considerable reduction of BOD entering the aeration tank. The study has revealed that AOP is effectively accomplishing the target, and reducing the volume of the aeration basin to less than 60% of its original volume (capacity). The cost analysis shows a cut in per unit cost from (0.17 $/m3) to (0.16 $/m3).

في ضوء الحاجة الملحة الى اعادة استخدام مياة المجاري لاغراض سقي المزروعات بسبب ازمة المياة في العالم عامة و العراق بصورة خاصة. تخضع مواصفات المياة الخارجة من وحدات معالجة المياة الثقيلة الى محددات بيئية دقيقة تهدف الى حماية الصحة العامة. يهدف هذا البحث الى تحديد نوع و مستوى المعالجة المتقدمة المطلوبة لتحديث محطة معالجة مياة ثقيلة تقليدية سعة 60000 م3 يوم (لمشروع تحت الانشاء). وجد ان اضافة وحدة ازالة الفسفور و النتروجين ضرورية لتحقيق مواصفات مطابقة للمحددات البيئية. برزت الحاجة الى اعادة تصميم حوض التهوية مع اضافة وحدة اكسدة متقدمة بطريقة (FENTON ) بعد احواض الترسيب االابتدائية. جرت عملية تقييم فني و اقتصادي لوحدة FENTON وتحققت نتائج ايجابية تلخصت بخفض قيمة BOD الداخل الى حوض التهوية و اختزال حجم الاكسدة الى اقل من 60% من الحجم الاصلي بالاضافة الى خفض كلفة معالجة المتر المكعب من المياه الثقيلة من (0.17 $/m3) الى (0.16 $/m3).

Keywords


Article
Study And Evaluation The Optimal Performance Of The Mixing Chlorine Tank In Dhi Qar Wastewater Treatment Plant In Iraq
دراسة وتقييم الاداء الامثل لحوض مزج كلور التعقيم لمحطة معالجة مياه الصرف الصحي في محافظة ذي قار في العراق

Author: Ali Hadi GHAWI علي هادي غاوي
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2017 Volume: 11 Issue: 2 Pages: 1-14
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Chlorine contact tank in water and waste water treatment plant suffer from a lack of efficiency disinfected treated water, which discharge to the rivers and they need a large amount of chlorine for the purpose of disinfection as a result of the presence of dead zones in the basins of chlorine as well as the need to contact a long more than exact standard specifications for the tanks disinfection time. This study deal with optimal performance basin mixing chlorine, which is located at the beginning of Chlorine contact tank of waste water treatment plant in the city of Nasiriyah in Dhi Qar, which is located south of the province of Iraq. In this paper, the use of computational fluid dynamic model in the numerical analysis for the purpose of finding the optimum performance of the chlorine mixing tank with the help of the program FLUENT 6.3.26 and program GAMBIT 2.3.16. Also in this study was used User Defined Function for the purpose of improvements of mixing chlorine. Where the results of the study showed that the ideal rotational speed of the mixer is 140 rpm as well as the results showed Numerical Model that can reduce chlorine dose to 5 mgliter, which is the optimum concentration of chlorine to be supplied for wastewater disinfect and is identical to the Iraqi specifications water sanitation, which discharge to the Euphrates River. In this study the best contact time of chlorine which give the best performance for mixing was 20 seconds.

تعاني احواض التعقيم في محطات الصرف الصحي من قلة الكفاءة بتعقيم المياه المعالجة التي تطرح للأنهار وبالتالي فهي تحتاج الى كمية كبيرة من الكلور لغرض التعقيم وذلك نتيجة لوجود مناطق لا يصلها الكلور (Dead Spaces) في احواض الكلور (Contact Tank ) وكذلك تحتاج الى زمن تماس طويل اكثر من المحدد بالمواصفات الخاصة بأحواض التعقيم. تناول هذا البحث دراسة الاداء الامثل لحوض مزج الكلور الذي يقع في بداية حوض تعقيم مياه الصرف الصحي لمحطة معالجة مياه الصرف الصحي في مدينة الناصرية في محافظة ذي قار التي تقع جنوب العراق. تم في هذا البحث استخدام نموذج ديناميكيا السوائل الحسابية CFD (Computational Fluid Dynamics) في اجراء تحليل رقمي ثنائي الأبعاد لغرض ايجاد الاداء الامثل لحوض مزج الكلور بالاستعانة ببرنامج FLUENT 6.3.26 و برنامج GAMBIT 2.3.16 وتم استخدام تعريف الدالة UDF (User Defined Function) لغرض اجراء التحسينات في الموديل الرياضي بما يناسب حوض مزج الكلور موضوع البحث. بينت نتائج الدراسة ان سرعة الدوران المثالية لجهاز المزج هي 140 دورة الدقيقة وانه يمكن تقليل تركيز الكلور المستخدم لتعقيم مياه الصرف الصحي الى 5 ملغراملتر, وهو التركيز الامثل للكلور الواجب توفيره للحصول على مياه صرف صحي معقمة ومطابق للمواصفات العراقية لمياه الصرف الصحي التي تطرح لمياه نهر الفرات. وكذلك تم في هذه الدراسة ايجاد افضل زمن تماس للكلور والذي يحقق وافضل اداء وقيمته 20 ثانية.


Article
PERFORMANCE EVALUATION OF AL-DEWANYIA WATER TREATMENT PLANT IN IRAQ
تقيم أداء محطة معالجة مياه الشرب في مدينة الديوانية

Author: د . علي هادي غاوي,د. عباس عليوي الجبوري
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2009 Volume: 2 Issue: 4 Pages: 664-677
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

In order to design and operate an effective water treatment system, a thorough understanding of the process of coagulation-flocculation and filtration is essential in the delivery of water of the greatest clarity and lowest possible turbidity in the finished water. This research outlines the finding of investigation of the treatment plant in Al-Dewanyia in Iraq. Performance of Al-Dewanyia Water Treatment Plant in Iraq is an essential parameter to be monitored and evaluated to better understanding of design and operating difficulties in water treatment plants. The conclusions of these evaluations may determine required recommendations and highlight modification requirements for continuous design and operating schemes. The evaluation conducted in this research was carried out by reviewing the engineering design to assure matching of standards and codes. Also, physical (turbidity and TSS) , and biological, analysis were conducted to investigate water quality. The conclusions drawn from this research outlines the importance of accurate engineering design and need for continuous monitoring and analysis of each unit performance. Finished water is not conforming to World Health Organization (WHO) Standard for Drinking water.

لتصميم و تشغيل محطات معالجة مياه الشرب بكفاءة عالية, يتطلب أدراك شامل لعمليات و مراحل معالجة مياه الشرب من تخثير, تلبيد و ترشيح لغرض أنتاج مياه صالحة للشرب و تقليل العكورة إلى أدنى حدود مسموحه. يلخص هذا البحث تقيم أداء محطة معالجة مياه الشرب في مدينة الديوانية في العراق. يعتبر تقييم أداء محطة معالجة مياه الشرب في مدينة الديوانية عامل ضروري و مهم لمراقبة و تقيم و فهم صعوبات التصميم و التشغيل لمحطات معالجة مياه الشرب في العراق لان معظم محطات المعالجة في العراق لها نفس التصميم الهيدروليكي ومصدر المياه هو النهر (مياه سطحية) و لكن تختلف في مقدار التدفق. في هذا البحث تم تقييم التصميم الهندسي لمحطة المعالجة لغرض التأكد من مطابقته للمحددات التصميمية. و لغرض تقييم نوعية الماء الناتج من المحطة تم قياس العكورة, المواد الصلبة العالقة, و الملوثات الحيوية في مختبر محطة المعالجة. و من أهم نتائج هذه الدراسة هو وجوب الاهتمام بتصميم محطات المعالجة و المراقبة المستمرة لمراحل المعالجة و تحليل أداء كل مرحلة. ان نوعية الماء الناتج ن محطة المعالجة لا يتوافق مع معاير ومحددات منظمة الصحة العالمية لمياه الشرب.


Article
IRAQI WATER TREATMENT PLANTS PROCESS CONTROL BY MEASURING EFFLUENT TURBIDITY
السيطرة على وحدات معالجة مياة الشرب في العراق بقياس كمية العكورة الناتجة

Authors: Jwad Khadhum. Ghaziy م.م. جواد كاظم غازي --- Ali H. GHAWI1 د.علي هادي غاوي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2010 Volume: 3 Issue: 4 Pages: 373-381
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The Al-Dewanyia Water General Authority (DWGA) operates and maintains four water treatment plants to produce potable water for 300,000 inhabitations in Al-Dewanyia city. Surface water from Al-Dewanyia river is treated by aluminum sulphate (alum) coagulation, flocculation, sedimentation, filtration, and chlorine disinfection (clearwell). DWGA has set goals for turbidity for clarified and filtered water. These goals pertain to water inside the Water Treatment Plant (WTP), outside the water treatment plant, and in the distribution system, DWGA continues to meet the Iraqi Ministry of Health Standard of 5 NTU. Each day at DWGA WTPs, chemists measure the turbidity of water from each individual clarifier and from each individual filter. The WTP Manager reviews this data and uses it to make process control decisions about chemical dosage and filter backwash. This paper explains DWGA’s Turbidity Goal for filtered water, presents recent data, and describes how WTP managers use this data for process control. Any water treatment plant in Iraq can use these procedures. The results can be better process control and higher quality water

مديرية ماء الديوانية تشغل و تصين اربعة محطات لمعالجة مياه الشرب في مدينة الديوانية و التي تخدم 300,000 ألف نسمة. ان مصدر المياه المعالج هو نهر الديوانية و تستخدم وسائل التلبيد (إضافة الشب) و التخثير و الترسيب و الترشيح و التعقيم في تصفية المياه. مديرية ماء الديوانية و ضعت أهداف لإزالة العكورة من حوضي الترسيب و الترشيح. هذة الأهداف تتمثل بالحصول على ماء صالح للشرب و مطابق للمواصفات العراقية و البالغة NTU 5 . تم قياس تركيز العكورة يوميا من أحواض الترسيب و أحواض الترشيح. المهندسين المسئولين عن تشغيل المشروع قاموا بتحليل تلك القياسات لاتخاذ قرار حول مقدار الشب المضاف و عملية غسل الفلاتر. من خلال هذا البحث تم توضيح وسيلة فعالة من خلال القياسات اليومية لتركيز العكورة للحصول على ماء مطابق للمواصفات العراقية.ان هذة التقنية يمكن استخدامها في أي محطة معالجة لمياه الشرب في العراق.


Article
PERFORMANCE PREDICTION OF ROTATING BIOLOGICAL CONTACTOR IN WASTEWATER TREATMENT APPLICATIONS
تخمين الأداء للملامسات البايولوجية الدوارة في محطات معالجة المياه الثقيلة

Author: Amer D. Zmat ,Ali H. GHAWI عامر دحام زماط ,علي هادي غاوي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2009 Volume: 2 Issue: 2 Pages: 164-176
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Biofilm models were used to model and predict the performance of Rotating Biological Contactors (RBC) in wastewater treatment plants. Assessment techniques have been adopted to evaluate this method in terms of hydraulic loading and Biochemical Oxygen Demand (BOD) removal. The results revealed that RBC not only is efficient, but also proven to be odor controlling reactor. RBC provides efficient mixing and reduces time of retention to minimum, so that a great reduction of area of treatment plants will be achieved.

تم استخدام موديلات الأغشية البيولوجية لتمثيل وحدة معالجة مياه الصرف الصحي التي تعتمد الملامسات البيولوجية الدوارة. جرى تقيم ذلك النوع من الوحدات من خلال دراسة تأثير معامل التحميل الهيدروليكي على كفاءة الإزالة لل BOD . ثم جرى تقيم زيادة عدد الأقراص البيولوجية ( bio-disks ) على كفاءة العملية, واطهرت نتائج الدراسة و التحليل إن عملية الخلط الجيد التي تحققها الملامسات البيولوجية الدوارة نتيجة الدوران ترفع كفاءة عملية المعالجة بشكل ملموس وتقلل زمن البقاء المطلوب للمعالجة و بالتالي يؤدي إلى اختزال المساحات والكلف لبناء مثل تلك الوحدات

Keywords

BOD --- COD --- organic material --- wastewater --- biofilm.

Listing 1 - 10 of 12 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (12)


Language

English (8)

Arabic and English (3)

Arabic (1)


Year
From To Submit

2017 (2)

2012 (1)

2011 (4)

2010 (2)

2009 (3)