research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Effect of The Elevated Temperature on the Tensile Strength of Cold Cured Acrylic Denture Base in Comparison to Heat Cure Acrylic
تأثير درجه الحراره المرتفعه على قوه الشد لقاعده الطقم ذات الاكريلك(الراتنج) البارد بلمقارنه مع الاكريلك الحار

Authors: AMAL ABDUL-LATIF RASHID --- LAYLA MOUSA Ouda
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2011 Volume: 9 Issue: 3 Pages: 126-133
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

Acrylic denture base materials were possessing adequate mechanical strength to with stand the load of mastication. The strength properties of cold cured is lower than that of the heat cured. Studies were done to increase the strength of cold acrylic resin. The purpose of this study was to evaluate the tensile strength of cold cured when polymerized by elevated temperature and compare to those polymerized by conventional methods also to compare it with heat cured acrylic polymerized by the same methods. Sixty specimens, thirty from cold cured acrylic and thirty from heat cured acrylic were prepared, flasking and packing procedure were done according to manufacturer direction and divided according to polymerization as follow:20 specimens(10 from cold cured and 10from heat cured acrylic)were polymerized by ivomat curing device containing water under air pressure 30 Pascal for 15 minutes at37˚C. 20 specimens (10 from cold cured and 10from heat cured acrylic) were polymerized by microwave oven; the power level was set at 50% to get 500 watts output for 3 minute and 20 specimens (10 from cold cured and 10from heat cured acrylic)were polymerized by water bath (fast cycle).All specimens were tested for tensile strength. Result showed that the cold cured acrylic have high value of tensile strength when processed by elevated temperature (by water bath and microwave) in comparison to those processed by conventional methods (Ivomate)with highly significant differences P<0.01, There was no significant differences P=0.11 between cold cured acrylic groups that polymerized by water bath and heat acrylic groups that polymerized by microwave. Heat cured acrylic that polymerized by water bath show the maximum value for tensile strength followed by heat cured acrylic that polymerized by microwave, then by cold cured acrylic groups that polymerized by water bath ,while the least group for the tensile strength recorded by heat cured acrylic that polymerized by Ivomate. Also show there was significant and highly significant differences between all groups (cold and heat cured acrylic) processed by three methods (Ivomate, water bath, microwave).

الاكريلك الراتنجي لماده قاعده الطقم يتحمل قوة ميكانيكية كافية ليقاوم ضغط المضغ خصائص القوة للاكريلك البارد هي اقل من الاكريلك الحار الدراسات اجريت لزيادة قوة الاكريلك البارد.ان الهدف من هذه الدراسه لتقييم قوه الشد للاكريلك البارد عند بلمرته بواسطه درجات حراره عاليه ومقارنته بلمتبلمر بلطريقه الاعتياديه باستخدام جهاز Ivomateومقارنته ايظا بالاكريلك الحار اللمتبلمر ينفس الطرق . 60عينه,30من الاكريلك البارد و30من الاكريلك الحار حضرت ووضعت في البودقه طبقا لتعليمات الصنع وقسمت الى مجاميع حسب البلمره ,20عينه (10من الاكريلك الحار و من الاكريلك البارد10 )بلمرت بواسطه جهاز Ivomateتحت ضغط حراري30باسكال/انج2لمده 15دقيقه بدرجه˚37سيليليزيه و20عينه (10من الاكريلك الحار و من الاكريلك البارد10 )بلمرت بواسطه المايكروويف تحت مستوى طاقه50%,500واط لمده3دقائق,و و20عينه (10من الاكريلك الحار و من الاكريلك البارد10 )بلمرت بواسطه الحمام المائي(الطريقه السريعه).جميع العينات خضعت لاختبار قوه الشد.اضهرت النتائج بأن الاكريلك البارد الذي بلمر تحت بدرجات حراره مرتفعه (بواسطه الحمام المائي و المايكروويف) يمتلك قيمه اعلى لقوه الشد مقارنه مع الاكريلك البارد المتبلمر بلطريقه الاعتياديه باستخدام جهاز Ivomateوبفروق معنويه عاليه0,01 P<,ولاتوجد فروق معنويه 0,11 P= بين مجموعه الاكريلك البارد الذي بلمر بواسطه الحمام المائي مع الاكريلك الحار الذي بلمر بواسطه المايكروويف. الاكريلك الحار الذي بلمر بواسطه الحمام المائي سجل اعلى قيمه لقوه الشد تلي بالاكريلك الحار الذي بلمر بواسطه المايكروويف ,ثم تلي بالاكريلك البارد الذي بلمر بواسطه الحمام المائي بينما سجل الاكريلك الحارالذي بلمر بواسطه جهاز Ivomate اقل قيمه لقوه الشد.ايظا اظهرت النتائج بأن هناك فروق معنويه وفروق معنويه عاليه بين جميع المجاميع المتبلمره بطرق الثلاثه (Ivomate ,المايكروويف ,الحمام المائي)

Keywords


Article
Caries experience and treatment need among students of health and medical technologies college.

Authors: Ola Mohammed Abdullah --- Sebeha Mehdy Kanaan --- Amal Abdul latif Rashid
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2010 Volume: 8 Issue: 1 Pages: 206-212
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

250 students from Health and Medical Technology Collage, who aged was between (19-22 years) where choiced randomly from 1239 students(the total number of the college) and they were conducted to oral health survey. The aim of this study was to assess the oral health status and treatment needs for these students. The WHO criteria (1987) were used to assess the individual tooth status and treatment needs. This study has shown that the mean DMFT per subject was found to be 7.2 and there was no caries-free subject in the examined sample. Female had higher caries experience than male.Results have demonstrated that the mean number of filled teeth per subject was 2.4. The mean of filled teeth in females were highly significant difference with males (P value > 0.001). The mean number of missing teeth per subject was 0.7. The mean of missing teeth in females was not significant with male (P value 0.93) and the mean number of decayed teeth per subject was found to be 4.2. The mean number of decayed teeth in female was not significant with males (P value 0.45). The percentage of teeth that need filling 96 %, teeth need crown abutment was 34%, teeth need bridge element was 36%, teeth need pulp care was 1.6 %, and teeth need extraction was 7.2%. From this study we can conclude that both age and gender had a statistically significant association with DMFT.

250 طالب من كلية التقنيات الصحية والطبية والذين تتراوح اعمارهم بين 19-20 سنة والذين تم اختيارهم عشوائيا من بين 1239 طالب (العدد الكلي لطلاب الكليه) وخضعوا لتطبيق المسح الميداني لحالة الفم الصحية .الهدف من هذه الدراسة هو لتقييم الحالة الصحية للفم وقياس الحاجة للمعالجة بين هؤلاء الطلاب. نظام منظمة الصحة العالمية ((WHO لسنة 1987 استخدم لتقييم حالة السن وقياس حاجته للعلاج. هذه الدراسة اظهرت ان معدل الاسنان المتسوسة والمفقودة وذوات الحشوة (DMFT ( هو 7.2 . لا يوجد شخص من بين الاشخاص الذين تم فحصهم خالي من التسوس [ أي معدل (DMFT ( له صفر]. أن نسبة الاناث كان اعلى من نسبة الذكور بالنسبة لمعدل التسوس. اظهرت النتائج ان معدل الاسنان ذوات الحشوة هي 2.4 سن/شخص ,معدل الاسنان ذوات الحشوات في الاناث هو اكثر من الذكور وبفرق معنوي كبير (0,001 P<). معدل الاسنان المفقودة هي (0.7) والفرق بين معدل الاسنان المفقودة في الاناث مقارنة مع الذكور هو فرق غير معنوي (0,93 P =). ومعدل الاسنان المتسوسة هي 4.2 والفرق ايضا غير معنوي ( 0,45p=) بين معدل الاسنان المتسوسة في الاناث مقارنة مع الذكور.ان نسبة الاسنان التي تحتاج الى حشوة كانت تمثل 96% من مجموع الطلاب الذين تم فحصهم ونسبة الاسنان التي تحتاج الى التيجان هي 34%, ونسبة الاسنان التي تحتاج الى جسور هي 36 %, الاسنان التي تحتاج الى علاج في الجذر هي 1.6% والاسنان التي تحتاج الى قلع تمثل 7.2%.ومن هذا البحث يمكن الاستنتاج ان هناك علاقة معنوية بين العمر والجنس مع. DMFT

Keywords


Article
Effect of sodium fluoride on the properties of acrylic resin denture base material subjected to long-term water immersion

Author: Amal Abdul-Latif Rashid امل عبد اللطيف رشيد
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 4 Pages: 14-21
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Fluoridated acrylic resin material can present more stable properties when compared withconventional one.The most widely used fluoride –containing substance added to dental resin materials is sodiumfluoride (Naf). This study evaluated the effect of Naf in different concentration to the acrylic resin denture basematerial and its effect on tensile strength ,modules of elasticity with long –term water immersion (after 4 monthsimmersion in de-ionized water)Materials and methods: Eighty specimens from dumbbells shaped metal pattern for tensile strength test werepreparedaccording to ISO 527: 1993 plastic –Determination tensile properties ,in dimensions(60mm, 12mm, 3 ±0.2mm) length, width and depth respectively were allocated to two groups according to water immersion therewere 40 specimens before immersion and 40 specimens after water immersion for 4 months in de-ionized water(thede-ionized water was changed every day),these two groups were sub divided in to four groups according to theconcentration of Naf,Naf powder were added to monomer of acrylic in concentrations of 1%,2%and 5% Naf .0%Naf(control group) ,then mixing were done with polymer according to manufacture instructions ,the conventionalflasking ,packing procedure were used following that (fast cycle). For tensile strength test the measuring was doneby Instron machine, the values of modulus of elasticity were obtained from tensile test.Results: Results showed that the addition of sodium fluoride to acrylic resin material werelower the tensile strengthand modules of elasticity with highly significant differences p<0.01 when compared to control group regardless theconcentration of Naf,But after immersion (for 4 month ) the tensile strength and modules of elasticity increased incomparison to groups before immersion (with highly significance differences p <0.01 ), highly significance differences(p <0.0)were found between groups after and before immersion in all concentrations except for tensile strengthbetween 1%Naf and 2%Naf after immersion there was no significant differences(p>0.05), and for modules ofelasticity between control and 1%Naf, 1% Naf and 2%Naf( after immersion ),there was only significant differencesbetween them(p<0.05).Conclusions: Addition of fluoride to acrylic resin material lower the tensile strength and modules of elasticity whencompared to control group regardless the concentration of Naf, But after immersion (for 4 months ) the tensilestrength and modules of elasticity increased in comparison to groups before immersion (with highly significancedifferences p <0.01)

الخلاصةالمقدمة:مادة الراتنج الاكریلیك المفلوره یمكن أن تقدم خصائص أكثر استقرارا بالمقارنة مع المادة التقلیدیة للاكریلیك. الأكثر استخداما على نطاق واسع مواد الفلوراید المضافة الىالموادالراتنجیة ھو فلورید الصودیوم.الھدف من الدراسة:دراسة تأثیر اضافھ تراكیز مختلفة من صودیوم الفلوراید للاكریلیك الراتنج ومعرفة تأثیره على قوة الشد ،معامل المرونة مع الغمر في الماء الایوني لمدى طویل(بعد 4 أشھرغمر في الماء الأیوني)3) عرض طول و عمق.قسمت الى قسمین حسب ± المواد وطریقة العمل: 80 عینة من شكل عظمة الكلب على نمط معدني حضرت لأختبار قوة الشد وحسب الابعاد ( 60,12,0,2الغمر بلماء الایوني , 40 عینة قبل الغمر و 40 عینة بعد الغمر بلماء الایوني لمدة اربعة اشھر مع تغییر الماء الایوني المغمورة فیھ یومیاوقسمت ھاتین المجموعتین الى إلى أربعة0٪(مجموعة السیطرة عدم احتوائھا على صودیوم ,٪5 ، ٪ 2 ، ٪ مجموعات فرعیة وفقا لتركیز ماده صودیوم الفلوراید ، أضیفت مسحوق صودیوم الفلوراید لسائل الاكریلیك بنسبة 1فلوراید), ثم خلط مع بودر الاكریلك (البولیمر)وفقا لتعلیمات الصنع.لأختبار قوة الشد تمت بواسطة جھاز الانسترون .أما معامل المرونة تم قیاسھا من نتائج اختبار قوة الشد.مقارنة مع مجموعة السیطرة ( p < النتائج :تظھر النتائج أن إضافة الفلورید إلى مادة الراتنج الاكریلیك قد خفض قوة الشد و معامل المرونة, مع وجود فروق معنویة عالیة ( 0.01بغضالنظر عن تركیز صودیوم فلوراید, أما بلنسبة للقیاس بعد الغمر بلماء الایوني(لمدة اربعة اشھر) تظھر النتائج بزیادة قوة الشد ومعامل المرونة مقارنة مع المجموعة قبل الغمر مع2 ٪ صودیوم ، ٪ بین جمیع المجامیع والتراكیز قبل الغمر وبعده ماعدا في قیاس قوة الشد بین تركیز 1 ( p < ھناك فروق معنویة عالیة ( 0.01 .( p < وجود فروق معنویة عالیة( 0.01وبلنسبة لقیاس معامل المرونة بین:تركیز 1 ٪ و 2 ٪ صودیوم فلوراید ,و مجموعة السیطرةو 1 ٪صودیوم فلوراید( بعد الغمر) (p> فلوراید (بعد الغمر) فلایوجد فروق معنویة( 0.05.(p< توجد فقط فروق معنویة( 0.05الاستنتاجات:نستنتج بأن اضافة الفلوراید الى مواد الاكریلك الراتنج یؤدي الى انخفاضقوة الشد و معامل المرونةمقارنة مع مجموعة السیطرة بغضالنظر عن تركیز صودیوم فلوراید,( p < لكن بعد الغمر بلماء الایوني(لمدة اربعة اشھر) تزداد قوة الشد ومعامل المرونة مقارنة مع المجموعة قبل الغمر مع وجود فروق معنویة عالیة( 0.


Article
Temperature Effect on the Hardness of Different types of Resin Denture Base Materials

Author: Dr. Amal Abdul-Latif Rashid, M.Sc. Preventive Dentistry, Lecturer د. امال عبد الطيف
Journal: MUSTANSIRIA DENTAL JOURNAL مجلة المستنصرية لطب الاسنان ISSN: 18138500 Year: 2013 Volume: 10 Issue: 1 Pages: 69-76
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The cold cured acrylic resin is inferior to heat cured acrylic resin from stand pointof strength and degree of polymerization. Many attempts have been made to improvethese properties. Because heat affects maturity of the chemical reaction of acrylicresin therefore its maintenance during polymerization will affect the properties ofcured resin.The purpose of this study was to evaluate the effect of increase curing temperatureon the hardness of two commercially available cold cured acrylic resin material(Holland and Germany type) in comparison to heat cure resin and to those(cold cure)curing by conventional methods in air at 23°C ± 5°C.Ninety specimens,10 specimens from heat cure resin curing by water bath(shortcycle) and eighty specimens from cold cured acrylic [forty from cold curedacrylic(Holland Type) and forty from cold cured acrylic(Germany type)] wereprepared , flasking and packing procedure were done according to manufacturerdirection and divided according to processing as follow:20 specimens(10 fromHolland type and 10 from Germany type) were processed in air for two hours at 23°C± 5°C under press (bench curing) as a control, and 60 specimens(30 from Hollandtype and 30 from Germany type) were processed by ivomat curing device containingwater under air pressure 30 Pascal for 15 minutes at different temperature: 40°C,60°C, and 80°C(10 specimens for each groups) .All specimens were tested forhardness test by shore D device (adigital model) for measuring the indentationhardness of the specimens the test load was set to 50 Newton for shore (( D ))which issuitable for acrylic resin material .Result showed that heat cure resin show the maximum value of hardness(88.8),followed by cold cured acrylic type Germany( polymerized by elevatedtemperature 80˚C) (88.696) followed by cold cured acrylic type Holland polymerizedat 60˚C(88.471). While control group type Germany (polymerized at air bench)recorded the minimum value of hardness (81.83). All groups that polymerized at hightemperature: 40°C, 60°C, and 80°C show the higher value of hardness in comparisonto those processed by conventional methods (at air bench at 23°C ± 5°C) withsignificant and highly significant differences. There were highly significantdifferences between heat cure acrylic and cold cure (both types) processed byconventional methods and with cold cure Holland type processed at 40˚C, but therewere no significant differences between heat cure acrylic and cold cure (both types)processed at high temperatures.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2014 (1)

2013 (1)

2011 (1)

2010 (1)