research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Seismic Design Of Single Span Steel Girder Bridges And Bridges In Seismic Performance Category A

Authors: Esraa Mubder Edaan --- Abdul Muttalib I. Said
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 3 Pages: 5337-5351
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper studies the validity and accuracy of the seismic design force recommended by AASHTO for single span bridges. A parametric study for single steel girder bridges is presented, included the effect of span length and elastomeric bearing and lateral bracing (cross-frame) stiffness. The results of simplified AASHTO method are compared with response spectrum and time history analysis. Also studying the seismic design reqiurements for continuous steel girder bridges in seismic performance category (A), included the effect of span length, seismic zone, effect of elastomeric bearing and cross-frame stiffness and bridge skew on their seismic responses. It is concluded that the AASHTO simplified analysis method for single span bridges underestimates the seismically induced forces at supports and the proposed seismic design force of (2.5 multiplied by acceleration coefficient multiplied by tributary weight w(x)) has been recommended for single span bridges for seismic zone 3 and 4 and for soil type II. Also it is observed that the seismic design force for two span continuous bridges in performance category A is safe and conservative method to predict the shear forces transferred by connection elements to the substructures.

يدرس هذا البحث صلاحية ودقة قوى التصميم الزلزالية الموصاة من قبل (AASHTO) للجسور ذات الفضاء الواحد. تم عمل دراسة مقارنة للجسور ذات العوارض الفولاذية بفضاء واحد متضمنة تأثير طول الفضاء و صلابة الوسائد المطاطية وانظمة التثبيت الجانبي. تم مقارنة نتائج طريقة ال AASHTO المبسطة مع طريقة طيف الاستجابة والتحليل الزمني. أيضاً تم دراسة متطلبات التصميم الزلزالي لجسور العارضة الفولاذية المستمرة في صنف الأداءِ الزلزالي (A)، متضمنة تأثير طول الفضاء، المنطقة الزلزالية، تأثير صلابة الوسائد المطاطية وانظمة التثبيت الجانبي وإنحراف الجسر على استجاباتهم الزلزالية. تم التوصل الى ان طريقة ال(AASHTO ) المبسطة لتصميم الجسور ذات فضاء واحد تقلل من مقدار القوى عند المساند وان القوى التصميمية المقترحة من (2.5 ) مضروبة في معامل التعجيل (A) مضروبة في و زن منتظم W(X) ينصح بها لتصميم الجسور ذات الفضاء الواحد للمناطق الزلزالية 3 ,4 و لنوع التربة II . وايضا ًاظهرت الدراسة ان قوة التصميم الزلزالية 20%) من وزن المنشأ) الموصى بها من قبل ال (AASHTO) للجسور الواقعة في صنف الاداء الزلزالي (A) أمينة ومحافظة للتنبأ بمقدار قوى القص المنتقلة عبر عناصر الربط الى الهيكل السفلي.


Article
Effect Of Reinforcement Ratio On Punching Shear Strength Of Reactive Powder Concrete Slab Reinforced With CFRP Bars
تاثير نسبة التسليح على مقاومة القص الثاقب لسقوف المساحيق الفعاله المسلحه بواسطة قضبان الياف الكاربون البوليمريه

Authors: Abdul Muttalib I. Said --- Samir M. Chasib
Journal: Misan Journal of Acodemic Studies مجلة ميسان للدراسات الاكاديمية ISSN: 1994697X Year: 2017 Volume: 16 Issue: 32 Pages: 1-15
Publisher: Misan University جامعة ميسان

Loading...
Loading...
Abstract

This work is devoted to study the effect of reinforcement ratio (ρ) on punching shear strength of reactive powder concrete slab reinforced with CFRP bars. The experimental program includes investigating the effect reinforcement ratio (ρ) on the first crack, type of failure, load – deflection curve and compression the ultimate punching shear capacity with ACI – 440 equation. All tested slabs were with dimension (1150 × 1150) mm and tested under concentrated load on column at the center of the slab.

يهتن البحث الحالي بدراسة تاثير نسبة التسليح على هقاوهة القص الثاقب لسقىف الوساحيق الفعاله الوسلحه بىاسطة قضبباى اليبافالكاربىى البىليوريه. يتركب البرنباها العولبي حبىت استقتباي تباثير نسببة التسبليح علبى اوت بق نبىع الفشب, هحححبي لالحوب, –الهطببىت و هقارنببة اعلببى قيوببه لوقاوهببة القببص هببي هعا لببه الكببى ا هريكببي ل ACI-440 . كبب, الحوببافح الوفحىعببه بابعببا5511 هلن وفحتت تحت حو, هرك على الكىلىم بالوحتتف. × ل 5511


Article
Punching Shear Strength Of Reactive Powder Concrete Slab Reinforced With CFRP Bars
تاثير سمك السقف على مقاومة القص الثاقب لسقوف المساحيق الفعاله المسلحه بواسطة قضبان الياف الكاربون البوليمريه

Authors: Abdul Muttalib I. Said --- Samir M. Chasib
Journal: Misan Journal of Acodemic Studies مجلة ميسان للدراسات الاكاديمية ISSN: 1994697X Year: 2017 Volume: 16 Issue: 32 Pages: 34-48
Publisher: Misan University جامعة ميسان

Loading...
Loading...
Abstract

This work is devoted to study punching shear strength of reactive powder concrete slab reinforced with CFRP bars. The experimental program includes investigating the effect thickness of slab on the first crack, type of failure, load – deflection curve and compression the ultimate punching shear capacity with ACI – 440 equation. All tested slabs were with dimension (1150 × 1150) mm and tested under concentrated load on column at the center of the slab.

يهتى انبحث انحاني بدراسة تاثير س كً انسقف عهى يقاوية انقص انثاقب نسقىف ان سًاحيق انفعانه ان سًههحبىاسطة قضبا انياف انكاربى انبىني رًي . يتركز انبرنايح انع هًي حىل استقصاء تاثير س كً انسقف عهى اولشق, نىع انفشم, ينحني )انح مً انهطىل ( و يقارنة اعههى قي هً ن قًاويهة انقهص يهد يعالنه انكهىل ا يريكهي

Keywords

CFRP Bars


Article
BEHAVIOR OF CONCRETE BEAMS REINFORCED IN SHEAR WITH CARBON FIBER REINFORCED POLYMER

Authors: Amjad H. Abdul-Razaq Al-Modhafer --- Abdul-Muttalib I. Said Al-Mussaue
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 1 Pages: 46-61
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Carbon fiber reinforced polymers (CFRP) were widely used in strengthening reinforced concrete members in the last few years, these fibers consist mainly of high strength fibers which increase the member capacity in addition to changing the mode of failure of the reinforced concrete beams. Experimental and theoretical investigations were carried to find the behavior of reinforced concrete beams strengthened by CFRP in shear and bending. The experimental work included testing of 12 beams divided into 4 groups; each group contains 3 beams. The following parameters were taken into consideration:- Concrete crushing strength. - CFRP strengthening location (shear strengthening and both shear and flexure strengthening).Reinforced beams were simply supported subjected to two point loads. Each group consists of three beams; the first beam without CFRP, the second one, is strengthened with CFRP in shear and the third is strengthened with CFRP in both flexure and shear. Four groups with different crushing strength of (12, 20, 30 and 39 MPa). The CFRP sheets are attached externally.It was found that in beam with low crushing strength loads transfer to the CFRP at early stages while in those of high crushing strength, CFRP contribution only starts when full strength of the beam is fulfilled. A full bond between CFRP sheets and the concrete is assumed in the theoretical analysis. Comparison between the theoretical and the experimental results revealed the validity of the numerical analysis and the developed methods such that there was a difference of 13% in the ultimate strength for the tested and analyzed beams.

استعملت العناصر الإنشائية الخرسانية المسلحة المقواة بألياف البوليمر الكاربونية في السنوات الحديثة ، تتألف ألياف التقوية البوليمرية بصورة أساسية من ألياف )عالية المقاومة (حيث تزيد سعة التحمل بالإضافة إلى تغيير أسلوب الفشل للعتبات الخرسانة المسلحة.أجريت تحريات عملية ونظرية لسلوك العتبات الخرسانية المسلحة، لحالتي تقوية العتبات في مناطق فشل القص والانثناء المقواة باستخدام CFRP حيث يتكون البرنامج العملي من 12 عتبة فحص قسمت إلى أربعة مجاميع ،كل مجموعة تضم 3 عتبات. الدراسة أخذت بنظر الاعتبار مقاومة الانضغاط للخرسانة و حالة التقوية ، استعملت مرة للتقوية في منطقة القص وأخرى في منطقتي القص و الانثناء معاً.كل العتبات تم فحصها في فضاء بسيط الإسناد ومتعرض لنقطتي تحميل بينما المتغير الرئيس يمثل مقاومة الانضغاط للخرسانة و موقع . CFRP كل مجموعة تتكون من ثلاثة عتبات الأول وهو النموذج المرجعي وهو خالي من CFRP و الثاني يحتوي على CFRP في منطقة القص و هي عبارة عن سبعة شرائح مائلة بزاوية 45 درجة و الثالث يحتوي على CFRP في منطقتي القص و الانثناء.كل مجموعة لها مقاومة انضغاط مختلفة عن الأخرى وهي (12-20-30-39 MPa ). إستعمل CFRP كمقوي خارجي. أن استعمال CFRP له تأثير على نتائج الحمل الأقصى، شكل التشقق، الهطول. تم اكتشاف إن CFRP يشارك الخرسانة الضعيفة في أوقات مبكرة من الحمل بعكس الخرسانة التي لها قوة انضغاط عالية حيث تتحمل أولا هي لوحدها جميع الاجتهادات ثم تشاركها شرائح CFRP في التحمل.إن أفضل استخدام لشرائح CFRP في منطقة القص بسبب تحول القوى بصورة مباشرة إلى شد على هذه الشرائح. تم استعمال التحليل اللاخطي بواسطة العناصر ثلاثية الإبعاد لتحري أداء العتبات الخرسانية المسلحة المقواة ب CFRP، حيث تم استخدام البرنامج الحاسوبي ANSYS.اعتبرنا هنالك تماس تام بين شرائح CFRP والخرسانة. وتم الحصول على تنبؤ جيد لسلوك ما بعد التصدع. المقارنة بين النتائج النظرية والعملية أكدت صلاحية التحليل العددي و حيث كانت أكبر نسبة فرق في المقاومة القصوى أقل من 13 % لكل العتبات المفحوصة.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2017 (2)

2011 (1)

2010 (1)