Feasibility Study of Power Saving Based on Using EMMEDUE M2 Building System

Author: Akram. W. Izzat
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2008 Volume: 14 Issue: 4 Pages: 3257-3267
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work concentrates on the feasibility of the heat load reduction by utilizing some structural material with very poor heat conductivity as isolators for heat transmission. Average annular heating and cooling load is estimated for a typical building of certain area and design using ordinary structural material and EMMEDUE M2 building system. The basic element of the new structural material is made of a foam polystyrene core that is self extinguishing and chemically inert with varying density and thickness depending on panel type. The calculations are based on the average maximum and minimum monthly temperature in Baghdad. Building heating load could mainly depend on the average temperature difference per each daily hour per year, while building cooling load components are; direct solar radiation, transmission load, ventilation/infiltration load and internal load. Except the transmission load which depends on the same average temperature difference the other factors could be calculated separately.A reduction of 55% in the annual load is estimated per each house using the new building technology. For a district sums up 1000 houses of the new structural design the total saving of power will be 10.45 MW. The saving in heating and cooling cost is estimated based on capital cost of the diesel generation system and the fuel consumption cost. It has been concluded that the passive structural heat isolation is a very effective manner in countries like Iraq which has severe temperature differences between the summer and winter seasons.

يتركز البحث على مدى عملية تفليل الحمل الحراري بأستخدام مواد بناء ذات توصيل حراري ضعيف كمواد عازلة للأنتقال الحراري. تم تخمين معدل الحمل الحراري والتريد السنوي لبناية نموذجية ذات مساحة وتصميم معين بأستخدم مواد بناء عادية مقارنة بمادة بناء EMMEDUE M2. العنصر الأساسي في مادة البناء الجديدة مكونة من مادة البوليسترين الرغوية ذات قابلية الأطفاء التلقائي وغير الفعالة كيمياويا وبكثافات مختلفة وسمك يعتمد على نوع القطعة.تم بناء الحسابات على معدل القيم العليا والسفلى لدرجات الحرارة الشهرية في مدينة بغداد. يعتمد الحمل الحراري على معدلات فرق درجات الحرارة اليومية على مدار السنة بينما يعتمد حمل التبريد على: أشعة الشمس المباشرة¸ الحمل الأنتقالي, حمل التهوية, والحمل الداخلي. بأستثناء الحمل الأنتقالي الذي على نفس معدلات فروقات درجات الحرارة فأن بقية العوامل تحسب بشكل منفصل.تم تخمين مفدار النقصان في قيمة الحمل السنوي بقيمة مقدارها 55% لكل بناية يتم فيها أستخدام مواد البناء العازلة والمشار اليها في البحث. لحي سكني مكون من 1000 بناية مبنية من مادة البناء العازلة يكون مقدار الأدخار في طاثة التدفئة والتبريد 10.45 ميكاواط. تم حساب معدل الأدخار في كلفة التدقئة والتبريد بناءا على القيمة الفعالة لمنظومة التوليد وكلفة الوقود المتسخدم لمدة سنة. حيث تم الأستنتاج من البحث أن أستخدام مواد البناء العازلة في دول ذات مناخ قاري يكون ذا جدوى اقتصادية عالية جدا.


Article
Flash Evaporation Enhancement By Electrolysis Of Saturated Water Flowing Upwards In Vertical Pipe

Authors: Radwan Muhammad Addaiy --- Akram. W. Izzat
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 3 Pages: 5620 -5632
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental system was designed and built to produce the flash evaporation of upward water flow in a (1.8 m) vertical mounted glass test section pipe. The water loses the static head as it moves up, accordingly flash evaporation occurs somewhere inside the test section, where the water local temperature reaches its saturation temperature at that position, which is dependent on the water inlet temperature and its mass flow rate. The steam quality in the test section exit was measured by collecting the steam generated in the test section outlet and condensed in the condenser at specified time. The hydrogen bubbles are injected inside the two – phase mixture flow within the test section. These bubbles act as an exciter for steam generation inside saturated water. Water electrolysis using (12 V) and ionization current (7 A), increases steam quality at test section outlet by (33%) when it is compared to that obtained without water electrolysis. A reduction of (42%) in non-equilibrium temperature difference is achieved using the same ionization settings. The effect of ionization process on flash inception point and temperature is investigated from the experiments. The experimental results are compared to the theoretical results obtained using mathematical model based on solving the mass, momentum and energy equations for two –phase flow assuming separated flow model. The effect of the electrical power used for water ionization is simply simulated in these calculations using mass and heat balance equation that covers the boundary conditions of the system.

تم تصميم منظومة تجريبية لغرض تحقيق ظاهرة الغليان التلقائي أثناء جريان الماء إلى الأعلى داخل أنبوب زجاجي بطول (1,8 م ) مخصص للقياسات , عمودي التثبيت . عند جريان الماء إلى الأعلى فانه يفقد جزءا من ضغطه الاستاتيكي , عند ذلك يحصل الغليان التلقائي عند نقطة ما داخل الأنبوب الزجاجي تكون فيها درجة حرارة الماء مساوية لدرجة حرارة الإشباع في تلك النقطة . تم قياس النسبة الوزنية للبخار ( steam quality ) في مخرج الأنبوب الزجاجي من خلال تجميع البخار المتولد في الأنبوب الزجاجي والمتكثف في جهاز التكثيف خلال فترة زمنية محددة . لقد تم حقن فقاعات الهيدروجين في داخل المزيج الثنائي الطور أثناء جريانه في الأنبوب الزجاجي. حيث تعمل فقاعات الهيدروجين كمحفز لتوليد البخار . لقد وجد إن نسبة البخار الوزنية (steam quality ) عند نهاية انبوبة الاختيار تزداد بنسبة ( 33 %) عما عليه بدون حقن تلك الفقاعات وذلك بتسليط فرق جهد قدره 12 فولت وتيار قيمته 7 أمبير, وانخفاض بنسبة (42%) من قيمة درجة الحرارة غير المتزنة عند نفس ظروف التأيين. إن تأثير عملية التائيين على نقطة بداية الغليان التلقائي ودرجة حرارته تم دراستها خلال الجزء العملي . النتائج العملية تم مقارنتها مع النتائج النظرية والتي حصلنا عليها باستخدام موديل رياضي يستند في حله على معادلات الكتلة والزخم والطاقة لجريان ثنائي الطور مع فرض نمط جريان أنفصال عند الحل . إن تأثير الطاقة الكهربائية المستخدمة في عملية التائيين يكون مبسطا في عمليات الحساب باستخدام معادلة توازن الكتلة والحرارة والتي تغطي الظروف المحيطة بالمنظومة.