research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Effects of Coupling between Lateral and Torsional Motions in Seismic Response of Buildings

Author: Husain Khalaf Jarallah حسين خلف جارالله
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2018 Volume: 18 Issue: 1 Pages: 16-30
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

The goal of the present paper is to study the adequacyof torsional provisions in the international buildings code (IBC)for irregular building taken into account effect of the angles ofseismic attacks. The responses of the frame-shear-wall twelvestory asymmetric building under earthquake loading by usingequivalent lateral force procedure and dynamic responsespectrum analysis have been studied intensively in this presentresearch paper. This study performs static and dynamicresponse analyses of building models under earthquake groundmotions compatible with the design response spectrum definedin the international buildings code. The dynamic responsespectrum was scaled according to the code static base shear. Thestatic and dynamic base shear with different angles of seismicattacks has been calculated. The scaling factors, angles ofseismic attacks, accidental storey torsions, storey shear,dynamic and static base shear have been evaluated here. Thetorsional moment at different storey levels for dynamic analysishas been estimated and compared with the static values.


Article
PUNCHING SHEAR STRENGTH AND DEFORMATION CAPACITY OF R.C. SLABS WITH DIFFERENT PATCH LOAD AREAS
مقاومة القص الثاقب وقابلية الهطول للبلاطات الخرسانية المسلحة تحت تاثير حمل البقعة وبمساحات تسليط مختلفة

Authors: Aamer Najim Abbas عامر نجم عباس --- Husain Khalaf Jarallah حسين خلف جارالله
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2014 Volume: 7 Issue: 1 Pages: 81-96
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

ABSTRACTThe main objective of this paper was to evaluate the effect of using different supporting areas or patch loads on a reinforced concrete slab within the slab-column connections. The increasing of the punching shear strength and deformation capacity when subjected to patch load was studied here. An experimental study was carried out on reinforced concrete slabs under a central patch load with circular, square and rectangular shapes of patch areas. A single concrete mix design was used throughout the test program. All of slab specimens were reinforced with distributed mesh reinforcement with equal steel ratios in both directions. The validation of the experimental work was made by analyzing the tested slabs by finite element method under cracking load. The results obtained by the finite element method were found to compare well with those obtained experimentally. In order to calculate the ductility for the tested slabs, the punching load has been determined by applying the published failure criterion and a load-rotation relationship obtained from semi-empirical relationship for the tested slabs. Conclusions on the influence of patch area on the punching shear capacity of reinforced concrete slabs were drawn. The experimental results confirm that the strength and deformation capacity are slightly influenced by the shape of the patch area. Among all specimens, the slabs with circular shape of patch area exhibited the best performance in terms of ductility and splitting failure.

الخلاصة:الهدف الرئيسي من هذا البحث هو تقييم تاثير شكل منطقة الاسناد على الاعمدة في البلاطات الخرسانية المسلحة ولمعرفة مقدار الزيادة في قوة القص ومقاومة التشوه في منطقة اتصال البلاطة الخرسانية مع العمود عند تسليط الاحمال. وقد أجريت دراسة تجريبية على بلاطات خرسانية مسلحة تحت تحميل احمال بقعية مع شكل مختلف من منطقة التسليط. وقد تم استخدام نسب حديد متساوية بكلا الاتجاهين مع خرسانة تملك نفس المواصفات لجميع النماذج مع سمك متساوي. دقة النتائج المستحصلة من الدراسة العملية جاءت معقولة ومقبولة مقارنة بالنتائج التحليلة المستحصلة من التحليل باستخدام العناصرالمحددة تحت الاحمال االتي تحدث عندها اول تشقق في خرسانة النماذج في منطقة الشد. تم تحديد الحمل الذي يتم حساب اليونة عند تسليطه باستخدام معادلة تم الحصول عليها من دراسات اخرى. النتائج العملية تؤكد ان شكل منطقة تاثير الاحمال يؤثر قليلا في مقاومة القص. كان الشكل الدائري لمنطقة التسليط اعطى أفضل أداء من حيث اليونة وفشل الخرسانة.


Article
EFFECT OF EXTERNAL SULFATE ATTACK ON MECHANICAL PROPERTIES AND MODELING OF HYBRID FIBER REACTIVE POWDER CONCRETE

Authors: Mohammed Mosleh Salman محمد مصلح سلمان --- Husain Khalaf Jarallah حسين خلف جارالله --- Shifaa Al-Bayati
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2017 Volume: 10 Issue: 3 Pages: 121-140
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Sulfate attack is a serious factor play important role in the degradation of structural capacity of reinforced concrete structures members especially those members exposure with ground water or sea water. This paper study the effect of external sulfate attack on mechanical properties of hybrid fiber reactive powder concrete (HFRPC) containing (polypropylene fiber and steel fiber) and normal strength concrete (NSC) after specimens have been casted, directly and continuously cured, and full immersed in saline solution containing magnesium sulfate, the concentration of the sulfate ion used in this study was equal to upper limit defined in ACI318M building code (10000 ppm), other specimens have been direct and continuously cured and fully immersed in tap water, prepare 108 cylinder, 36 cube and 36 prism for this purpose. The mechanical properties such as compressive strength, splitting tensile strength (measured splitting resistance and tensile strength), modulus of rupture (measured tensile strength) and modulus of elasticity (measured flexural strength) tests were investigated for HFRPC and NSC at different exposure periods (28, 90 and 180) days. Test results showed continuous development with time in mechanical properties for HFRPC when cured in sulfate water but test results for NSC showed significant deterioration when cured in sulfate water. An analytical equations have been derived by curve fitting to derive the relationships between the mechanical properties and compressive strength for HFRPC and NSC and its validation with ACI predicted. The ACI expression for the mechanical properties may result in underestimation of HFRPC and good accuracy of NSC under tap water and sulfate water curing condition.

تعد مهاجمة الاملاح الكبريتية مشكلة رئيسية تؤثر بشكل سلبي على الخرسانة والمواد الانشائية المختلفة. تناول البحث تأثير الاملاح الكبريتية الخارجية على مقاومة خرسانة المساحيق الفعالة المحتوية على الياف هجينة (الياف البولي بروبلين والياف الحديد) والخرسانة العادية بعد غمر النماذج كليا وبشكل مباشر ومستمر بعد الصب في محلول ملحي احتوى على كبريتات المغنسيوم المضافة بتركيز مساوي لاعلى تركيز محدد بالكود الامريكي,وكان هنالك نماذج اخرى مغمورة بشكل كلي ومباشر في المياه الاعتيادية الخالية من الكبريتات, وقد تم تهيئة 108 اسطوانة و36 مكعب و36 موشور لهذا الغرض. أجريت فحوصات مقاومة الانضغاط و الشد بالانشطار الغير المباشر ومعامل الانحناء ومعامل المرونة لكل من خرسانة المساحيق الفعالة والخرسانة العادية خلال فترات مختلفة من المعالجة بالمياه الاعتيادية ومياه الكبريتات وتشمل فترات المعالجة(28 و90 و 180) يوم وقد اجريت هذه الفحوص لكل النماذج المعالجة بالمياه الاعتيادية والمعالجة بالكبريتات. أظهرت نتائج الفحوصات الخاصة بخرسانة المساحيق الفعالة تطور مستمر أثناء معالجتها بمياه ألاملاح الكبريتية(محلول كبريتات المغنسيوم),بينما حصل تدهور واضح في النتائج المستحصلة من الخرسانة العادية عند نفس ظروف المعالجة. تم اشتقاق معادلات خاصة بعلاقة الخواص الميكانيكية مع قوة الانضغاط للخرسانة العادية والهجينة باستخدام منحني المناسيب وتم مقارنتها مع معادلات الكود الامريكي. تبين من الدراسة ان معادلات الكود الامريكي تعطي قيم اقل للخرسانة الهجينة وقيم جيدة للخرسانة العادية تحت تأثير المعالجة بالمياه الاعتيادية والمعالجة بالكبريتات.


Article
Experimental Investigation of Short Square Normal and Hybrid Fiber Reactive Powder Concrete Columns Subjected to Chloride Solution Attack
التصرف العملي للأعمدة الخرسانية القصيرة مربعة المقطع ذات الخرسانة العادية والمساحيق الفعاله المسلحة بالياف هجينة والمعرضة لهجوم محلول الكلورايد

Authors: Mohammed Mosleh Salman محمد مصلح سلمان --- . Husain Khalaf Jarallah حسين خلف جارالله --- Raed Satar Al-Behadili رائد ستار البهادلي
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 7 Pages: 75-94
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research, the structural behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) subjected to chloride salts with concentration was 8341.6 mg/l. The study consists of two parts, the first one is experimental study and the second one is theoretical analysis. Three main variables were adopted in the experimental program; concrete type, curing type and loading arrangement. Twenty (120x120x1200) mm columns were cast and tested depending on these variables. The samples were reinforced using two different bars; Ø8 for ties and Ø12 with minimum longitudinal reinforcement (0.01Ag). The specimens were divided into two main groups based on curing type: The first group consists of casting and testing of ten columns that cured in tap water for 28 days with two types of concrete (normal and hybrid), five columns for each type. While the second group consists of ten columns that direct cured and fully immersed in chloride water (8341.6 mg/l) 6 months with two types of concrete (normal and hybrid), five columns for each type. The specimens were tested under three types of loading, the first one is axial load, the second one is eccentric load with three different eccentricities (50,100 and 150) mm and where (e/h) are (0.42, 0.83 and 1.25) respectively from the center of column while the third type of loading is tested the specimens as beam.The experimental results showed an increase in ultimate load capacity and higher chlorides resisting for hybrid reactive powder concrete in comparison with normal concrete in both types of curing (tap and chloride water) through studying strain profile. Interaction diagram charts were obtained from different types of loading for each specimen. These charts showed high values for hybrid reactive powder concrete in comparison with normal concrete.

في هذا البحث تم دراسة التصرف الانشائي للاعمدة الخرسانية والمعرضة للاملاح الكلوريدية و (بتركيز 8341.6 ملغملتر) في نوعين من الخرسانة العادية وذات المساحيق الفعاله والمهجنة بالالياف ((steel and polypropylene fibers. تم اجراء ( جانبين في البحث الاول الجانب العملي والثاني الجانب النظري. يتضمن الجانب العملي ثلاث متغيرات هي نوع الخرسانة ونوع المعالجة ونوع التحميل, حيث تم صب وفحص 20 عمود خرساني بابعاد (120 × 120) ملم وبارتفاع 1200 ملم واستخدام نوعين من الاقطار لحديد التسليح Ø8 للاطواق المقاومة للقص و Ø12 التسليح الطولي وبنسبة 1%, تم تجزئة الجانب العملي الى جزئين: الجزء الاول وهو صب 10 اعمدة ومعالجتها في المياه العادية لمدة 28 يوم بنوعين من الخرسانة العادية والمهجنة 5 اعمدة لكل نوع خرسانة اما الجزء الثاني هو صب 10 اعمدة ومعالجتها بالمياه الكلوريدية و (بتركيز 8341.6 ملغملتر) وغمرها كليا لمدة 6 اشهر وايضا بنوعين من الخرسانة ولكل نوع 5 اعمدة.في الفحص تم تسليط ثلاث انواع من الحمل وهي الحمل المحوري واللامحوري وهي (50, 100, 150) ملم ونسبة ( (e/h0.42 , 0.83 و 1.25 ) من سنتر العمود والحمل الاخير هو فحص النموذج كعتبة.اظهرت النتائج العملية زيادة في الحمل والمقاومة في كلا المعالجة العادية والكلوريدية للخرسانة المهجنة مقارنة بالخرسانة العادية من خلال الحصول على interaction diagram chart, strain profile من خلال اختلاف نوع الحمل لكل نموذج حيث اظهرت النتائج الارقام العالية لرسم ال chart للخرسانة المهجنة مقارنة بالعادية.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2018 (2)

2017 (1)

2014 (1)