research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
CONVECTION HEAT TRANSFER IN A CHANNEL OF DIFFERENT CROSS SECTION FILLED WITH POROUS MEDIA

Authors: Ahmed A. Mohammad Saleh --- Suhad A. Rasheed --- Rafel B. Smasem
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2018 Volume: 9 Issue: 2 Pages: 57-73
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

A forced convection heat transfer in ducts (circular, triangular, rectangular) cross sections and (1m) length with hydraulic diameter (0.1m) filled with porous media (glass spheres 12 mm diameter) is investigated experimentally at constant heat flux from the wall (1070W/m²) with Reynolds number range of (12461-2500). Comparison was made between three ducts for local temperature distribution and local Nusselt number). The experimental results showed the effect of Reynolds number and cross section on the temperature profile and local Nusselt number,also empirical correlations for average Nusselt number and Peclet number were obtained for three ducts.


Article
Experimental and Theoretical Study for Performance Enhancement of Air Solar Collectors by Using Different Absorbers
دراسة عملية و نظرية لتحسين أداء المجمعات الشمسية الهوائية باستخدام سطوح امتصاص مختلفة

Authors: Taher Abbas Rashid طاهر عباس رشيد --- Ahmed A. Mohammad Saleh احمد عبد محمد صالح
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2016 Volume: 12 Issue: 3 Pages: 110-120
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental and theoretical study has been done to investigate the thermal performance of different types of air solar collectors, In this work air solar collector with a dimensions of (120 cm x90 cm x12 cm) , was tested under climate condition of Baghdad city with a (43° tilt angel) by using the absorber plate (1.45 mm thickness, 115 cm height x 84 cm width), which was manufactured from iron painted with a black matt. The experimental test deals with five types of absorber:- Conventional smooth flat plate absorber , Finned absorber , Corrugated absorber plate, Iron wire mesh on absorber And matrix of porous media on absorber .The hourly and average efficiency of the collectors were investigated for three values of mass flow rates (0.016 kg/s to 0.027 kg/s) for each type of collector and then the porosity for the last collector type was tested by changing the porosity of porous media.A typical air solar collector has been studied Theoretically to build a standard software for testing any type of air solar collectors with local weather data .From the experimental study it can be seen by using some obstacle material to the air flow (fins, corrugated absorber plate, iron wire mesh porous media on the absorber) could be enhanced the efficiencies not less than 4 % for finned type and 8 % for corrugated and 25 % for mesh and 30 % for porous media comparing with flat plate (smooth) collector .Theoretically, the results showed that the collector with high convention heat transfer coefficient porous media has high hourly efficiency about (η = 56 %) and iron wire mesh on absorber ( η = 52 % ), on the other side the minimum performance occurred in the flat plate absorber (η = 28 %).Comparison of results reveals that the theoretical predictions agree reasonably well with experimental results. And the difference between the theoretical and experimental efficiency in general was between (1─ 15 %).

تم القيام بدراسة عملية ونظرية لبحث الأداء الحراري لأنواع مختلفة من المجمعات الشمسية الهوائية, في هذا العمل ابعاد المجمع الشمسي الهوائي (120 cm x90 cm x12 cm) تم اختباره تحت الظروف المناخية لمدينة بغداد بزاوية ميل للمجمع،43°) ) باستخدام لوح امتصاص (1.45 mm thickness) , (115 cm height × 84 cm width)الذي تم تصنيعه من الحديد مطلي بطلاء اسود مطفي. تم التعامل في الاختبار العملي مع خمسة أنواع من سطوح الامتصاص : - السطح المستوي الاملس التقليدي (flat plat), زعانف على سطح الامتصاص (fins), سطح الامتصاص المتعرج ( (corrugated,مشبك معدني من الحديد (wire mesh) , وحشوه وسيط مسامي على لوح الامتصاص (porous). ان الكفاءة الساعية ومعد ل الكفاءة تم تحقيقها على ثلاث قيم من معدل التدفق (0.016 kg/s to 0.027 kg/s) لكل نوع من المجمعات الشمسية وأيضا تم اختبار المسامية للنوع الاخير عن طريق تغيير قيمه المسامية لحشوه الوسيط المسامي. تم دراسة نظريا أنموذج للمجمع الشمسي الهوائي وذلك لأنشاء برنامج قياسي لاختبار اداء أي نوع من المجمعات الشمسية على بياناتنا الجوية المحلية. من الدراسة العملية يمكن ان نلاحظ بواسطة استعمال بعض الاعاقات لمجرى الهواء (fins, corrugated absorber plate, Iron wire mesh, pours media) بانه قد امكن من تحسين الكفاءات ليس باقل من (4 % for finned type) و(8 % for corrugated) و(25 % for wire mesh) و(30 % for porous media) وذلك بالمقارنة مع المجمع الشمسي المستوي التقليدي . نظريا , أظهرت النتائج بان المجمع الشمسي ذو المعامل العالي لانتقال الحرارة هو الاعلى كفاءه وهو (pours media η = 56 %) ومن ثم يأتي ( Iron wire mesh η= 52%) في حين ان الاداء الاقل يحصل عند (flat plate η = 28 %.). مقارنة النتائج تظهر أن التوقعات النظرية تتفق بشكل منطقي مع النتائج التجريبية . وكانت عموماً الفروقات بين الكفاءة النظرية والعملية ما بين (1─ 15 % ) .

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (1)

English (1)


Year
From To Submit

2018 (1)

2016 (1)