research centers


Search results: Found 20

Listing 1 - 10 of 20 << page
of 2
>>
Sort by

Article
Electrocoagulation of phenol for wastewater treatment

Author: Ahmed A-Mohammed
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2008 Volume: 9 Issue: 3 Pages: 45-49
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Electrocoagulation is an electrochemical process of treating polluted water where sacrificial anode corrodes to produce active coagulant (usually aluminum or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles). The present study investigates the removal of phenol from water by this method. A glass tank with 1 liter volume and two electrodes were used to perform the experiments. The electrode connected to a D.C. power supply. The effect of various factors on the removal of phenol (initial phenol concentration, electrode size, electrodes gab, current density, pH and treatment time) were studied. The results indicated that the removal efficiency decreased as initial phenol concentration increased, the highest removal obtained at pH in the range (6-8), the removal enhanced with increasing electrode size and decreasing the gab between the electrodes. The optimum current density obtained at 221 A/m2.


Article
Removal of Emulsified Paraffine from Water: Effect of Bubble Size and Particle Size on Kinetic of Flotation

Author: Ahmed A. Mohammed
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2007 Volume: 8 Issue: 3 Pages: 1-5
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper studied kinetics of flotation of emulsified paraffine in water in a bubble column with sodium dodecylsuiphate as a collector agent. The effects of oil drops and air bubble diameters on the flotation rate constant were studied The removal rate for each oil drop size was first order with respect to oil drop concentration. An experimental procedure permitting determination of the first order rate constants for removal due to bubble/drop interaction was developed, decreasing bubble diameter by adding Naci and increasing oil drop diameter increased the rate constants. A comparison between the experimental and theoretical rate constants showed that the predicted mechanism of oil-droplet removed by bubbles less than 1. diameter is one of hydrodynamics capture in the wake behind the rising bubbles.

Keywords

f lotation --- emulsion --- kinetic


Article
Biosorption of Lead, Cadmium, and Zinc onto Sunflower Shell: Equilibrium, Kinetic, and Thermodynamic Studies

Author: Ahmed A. Mohammed
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2015 Volume: 16 Issue: 1 Pages: 91-105
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present study deals with the application of an a bundant low cost biosorbent sunflower shell for metal ions removal. Lead, Cadmium and Zinc were chosen as model sorbates. The influences of initial pH, sorbent dosage, contact time, temperature and initial metal ions concentration on the removal efficiency were examined. The single ion equilibrium sorption data were fitted to the non-competitive Langmuir and Freundlich isotherm models. The Freundlich model represents the equilibrium data better than the Langmuir model. In single, binary and ternary component systems,Pb+2 ions was the most favorable component rather than Cd+2 and Zn+2 ions. The biosorption kinetics for the three metal ions followed the pseudo-second order kinetics indicating that the chemical sorption was the rate-limiting step. The thermodynamic parameters including free energy (∆G0), enthalpy and entropy changes for Pb2+,Cd2+ and Zn2+ ions indicated that the sorption process was feasible,spontaneous,and endothermic in the temperature range 20-50 0 C .Desorption of the three metals ions from the biosorbent was effectively achieved in a 0.2 mol L-1 HCl solution.


Article
REMOVAL OF COPPER ION FROM WASTEWATER BY FLOTATION

Authors: Farah I. Abed --- Ahmed A. Mohammed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 6 Pages: 1483-1491
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Several industrial wastewater streams may contain heavy metal ions, which must be effectively removal before the discharge or reuse of treated waters could take place. In this paper, the removal of copper( II) by foam flotation from dilute aqueous solutions was investigated at laboratory scale. The effects of various parameters such as pH, collector and frother concentrations, initial copper concentration, air flow rate, hole diameter of the gas distributor, and NaCl addition were tested in a bubble column of 6 cm inside diameter and 120 cm height. Sodium dodecylsulfate (SDS) and Hexadecyl trimethyl ammonium bromide (HTAB) were used as anionic and cationic surfactant, respectively. Ethanol was used as frothers and the optimal removal conditions have been established. Successful removals about (98%) and (76%) could be achieved for copper ions with SDS and HTAB, respectively. Copper removal reached about 80% under the optimum conditions at low pH; at high pH it became as high as 98% probably due to the contribution from the flotation of precipitated copper. It was found that the presence of NaCl in the solution reduced the recoveries. Adding ethanol at 1% concentration increased the removal efficiency. From the results the rate of flotation was found to be first order


Article
Equilibrium and Thermodynamic Studies of Reactive Orange Dye Biosorption by Garden Grass
دراسة توازن وثرموداينمكية الامتزاز الحيوي للصبغة البرتقالية باستخدام ثيل الحدائق

Author: Ahmed A. Mohammed احمد عبد محمد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 4 Pages: 82-97
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present study aims to evaluate the biosorption of reactive orange dye by using garden grass. Experiments were carried out in a batch reactor to obtain equilibrium and thermodynamic data. Experimental parameters affecting the biosorption process such as pH, shaking time, initial dye concentrations, and temperature were thoroughly examined. The optimum pH for removal was found to be 4. Fourier transform infrared spectroscopy analysis indicated that the electronegative groups on the surface of garden grass were the major groups responsible for the biosorption process. Four sorption isotherm models were employed to analyze the experimental data of which Temkin and Pyzhey model was found to be most suitable one. The maximum biosorption capacity was 12.2 mg/g at 30 °C. The maximum removal percent reached 90% at optimum conditions. Therefore, the pretreatment or modification of this biosorbent may enhance the biosorption capacity. Thermodynamic parameters (i.e., change in the free energy, the enthalpy, and the entropy) were also evaluated and their values revealed that the biosorption process was exothermic in nature and less favorable at high temperature.

تهدف الدراسة الحالية الى تقييم الامتزاز الحيوي للصبغة البرتقالية الفعالة باستخدام ثيل الحدائق. اجريت العديد من التجارب بطريقة الدفعات لغرض الحصول على بيانات الامتزاز الحيوي و الثرموديناميكية. تم دراسة تأثير بعض الظروف في عملية الامتزاز مثل الدالة الحامضية، سرعة الخلط، التركيز الابتدائي، والحرارة. وجد ان افضل ازالة حصلت عند قيمة دالة الحامضية 4. بينت نتائج تحليل الثيل باستخدام الاشعة تحت الحمراء (FTIR) ان المجاميع الفعالة سالبة الشحنة الموجودة على سطح الثيل كان لها الدور الكبير في عملية الامتزاز. تم مطابقة النتائج العملية مع اربعة موديلات رياضية حيث بينت النتائج تطابق كبير مع الموديل المقدم من قبل TemkinوPyzhey. وصلت اعلى قيمة لعملية الامتزاز الى 12.2 ملغم/غم عند درجة حرارة 30 مئوية. و ان اعلى نسبة ازالة وصلت الى 90% بالظروف المثلى. لذا فان عملية المعالجة او التعديل للمادة الممتزة ربما تحسن عملية الازالة. اثبتت نتائج دراسة الثرموداينمك ان طبيعة الامتزاز هو باعث للحرارة و غير مفضل بدرجات الحرارة العالية.


Article
Experimental Study of The Performance of The Dual Purpose Solar Collector
دراسة عملية لاداء المجمع الشمسي المزدوج الغرض

Authors: Ahmed A. Mohammed Saleh --- Maytham A. Jasim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 11 Part (A) Engineering Pages: 2673-2683
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In the present work, experimental study has been done to estimate the performance of solar heating system by air-water (Dual) solar collector. Flat plate dual solar collector with dimensions (120 cm length, 80 cm width and 15 cm thickness) has been used for heating the test space with dimensions (2×2×2.5) m. In this study, the system has been operated in Al-Najaf city with 45o tilt angle to the south. The results obtained that the dual flat plate solar collector daily efficiency is 52.02 %.They also showed the ability to use dual solar collector absorber as heat exchanger in the night to maintain room temperature in the comfort condition for space heating in the winter season.

في هذا البحث تم اجراء دراسة عملية لتخمين اداء منظومة تدفئة بالطاقة الشمسية باستخدام مجمع شمسي هوائي مائي (مزدوج) لهذا الغرض . تم استخدام مجمع شمسي مستوي بابعاد 120 سم طول، 80 سم عرض و 15 سم سمك لتدفئة حيز بأبعاد 2 م طول، 2 م عرض و 2.5 م ارتفاع . تم تشغيل هذه المنظومة في مدينة النجف (الكوفة) و بزاوية 45o نحو الجنوب بالنسبة للمجمع الشمسي . لقد بينت النتائج العملية لهذه الدراسة ان الكفاءة اليومية للمجمع الشمسي المزدوج تساوي 52.02% . و كذلك اثبتت النتائج العملية انه من الممكن استخدام هذا النوع من المجمعات الشمسية كمبادل حراري في الليل للحفاظ على درجة حرارة فضاء معين ضمن درجات حرارة الراحة للأنسان كعملية تدفئة في فصل الشتاء.


Article
Biosorption of Methylene Blue from Aqueous Solution Using Mixed Algae
امتزاز صبغه المثيل الزرقاء من المحلول المائي باستخدام الطحالب المختلطة

Authors: Aya Abbas Najim --- Ahmed A. Mohammed
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2018 Volume: 19 Issue: 4 Pages: 1-11
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A mixture of algae biomass (Chrysophyta, Cyanophyta, and Chlorophyte) has been investigated for its possible adsorption removal of cationic dyes (methylene blue, MB). Effect of pH (1-8), biosorbent dosage (0.2-2 g/100ml), agitated speed (100-300), particle size (1304-89µm), temperature (20-40˚C), initial dye concentration (20-300 mg/L), and sorption–desorption were investigated to assess the algal-dye sorption mechanism. Different pre-treatments, alkali, protonation, and CaCl2 have been experienced in order to enhance the adsorption capacity as well as the stability of the algal biomass. Equilibrium isotherm data were analyzed using Langmuir, Freundlich, and Temkin models. The maximum dye-sorption capacity was 26.65 mg/g at pH= 5, 250 rpm, 89µm, 25˚C, and 50 mg/L as initial concentration. Four kinetic models were tested, pseudo first order, pseudo second order, intra- particle diffusion and Elovich model. Taking into account the analysis of the (SSR and X2), the data were best fitted to Temkin isotherm model. The pseudo-second order with higher coefficient of determination fitted the data very well. Thermodynamic parameters (ΔG0, ΔH0, ΔS0, Ea and S*) at temperature ranges of 293–313 K demonstrated that biosorption is an endothermic, spontaneous reaction and higher solution temperature favors MB removal by adsorption onto algae biomass. Results show that adsorption- desorption process lasts for five cycle before losing its efficiency and the recovery efficiency increased up to 80.52%.

تم استخدام خليط من الكتلة الحيوية للطحالب (Chrysophyta ، Cyanophyta ، و Chlorophyte) لازاله (الصبغه الزرقاء ، MB). تم دراسة تأثير الأس الهيدروجيني (1-8) ، كمية المادة المازة (0.2-2 جم / 100 مل) ، سرعة التحريك (100-300) ، حجم الجسيمات (1304-89 ميكرو متر) ، درجة الحرارة (20-40˚C) ، تركيز الصبغة الأولي (20 -300 ملغم / لتر) ، وتمت دراسة امتصاص الامتصاص لتقييم آلية امتصاص صبغة الطحالب. وقد تم تجربة مختلف المعالجات، القلويات ، والبروتونات ، و CaCl2 من أجل تعزيز قدرة الامتزاز وكذلك استقرار الكتلة الحيوية للطحالب. تم تحليل بيانات متساوي الحرارة باستخدام نماذج Langmuir و Freundlich و Temkin. كانت السعة القصوى لامتصاص الأصباغ 26.65 ملغ / غم عند الرقم الهيدروجيني = 5 ، و 250 دورة في الدقيقة ، و 89 ميكرو متر ، و 25 درجة مئوية ، و 50 ملغم / لتر كتركيز أولي. تم اختبار أربعة نماذج حركية ، من الدرجة الأولى الزائفة ، والنظام الثاني الزائف ، وانتشار داخل الجزبئة والنموذج Elovich. مع الأخذ بعين الاعتبار تحليل (SSR و X2) ، كانت البيانات الأفضل ملائمة لنموذج Temkin isotherm. اضهرت النتائج ان البيانات تخضع لمودبل الزائف من الدرجة الثانية. أظهرت المعلمات الديناميكية الحرارية (ΔG0 ، ΔH0 ، ΔS0 ، Ea و S *) عند درجات حرارة تتراوح بين 293-313 K أن الإمتصاص هو تفاعل ماص للحرارة ، وتفاعل تلقائي ، ودرجة حرارة أعلى للحل تدعم إزالة الصبغة الزرقاء بالامتزاز على الكتلة الحيوية للطحالب. تظهر النتائج أن عملية الامتزاز- الاسترجاع تستمر لمدة خمس دورات قبل أن تفقد كفاءتها وزيادة كفاءة الاسترداد إلى 80.52 ٪.


Article
ASSESSMENT OF DEPLETED URANIUM CONTAMINATION INSELECTIVE IRAQI SOILS

Authors: Nada F. Tawfiq --- Ali Sh. M. Hussien --- Ahmed A. Mohammed
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2008 Volume: 11 Issue: 1 Pages: 74-81
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The aim of this research was to measure the radiation exposure rates in three selected locations in southern part of Iraq (two in Nassireya, and one in Amara) resulted from the existence of depleted uranium in soil and metal pieces have been taken from destroyed tank and study mathematically the concentration of Depleted Uranium by its dispersion from soil surface by winds and rains from 2003 to 2007.The exposure rates were measured using inspector device, while depleted uranium contamination in soil samples and tank's metal pieces were detected with Solid State Nuclear Track Detectors (SSNTDs).The wind and rain effects were considered in the calculation of dispersion effect on depleted uranium concentration in soil, where the wind effect were calculated with respect to the sites nature and soil conditions, and rain effect with respect to dispersive-convective equation for radionuclide in soil. The results obtained for the exposure rates were high near the penetrated surface, moderate and low in soil and metal pieces. The Depleted Uranium concentration in soil and metal pieces have the highest value in Nassireya .The results from dispersion calculation (wind & rain) showed that the depleted uranium concentration in 2008 will be less than the danger level and in allowable contamination range.

الهدف من البحث هو قياس التعرض الأشعاعي في ثلاث مناطق منتخبة من جنوب العراق (موقعين في الناصرية وموقع في العمارة) الناجمة عن وجود اليورانيوم المنضب في التربة وقطع معدنية مأخوذة من دبابة مدمرة, وحساب تراكيز اليورانيوم المنضب وأنتشاره من سطح التربة بتأثير الرياح وألأمطار للفترة من(2003-2007). الجرع الأشعاعية تم حسابها بأستخدام جهاز ال( . (Inspectorوتم الكشف عن اليورانيوم المنضب في نماذج الترب والقطع المعدنية بأستخدام كواشف ألأثر النووي في الحالة الصلبة. الرياح وألأمطار أخذت بنظر ألأعتبار فى حساب تأثير ألأنتشار على تركيز اليورانيوم المنضب في التربة, حيث تم أحتساب تأثير الرياح نسبة الى طبيعة المنطقة وظروف التربة وأحتسب تأثير الأمطار نسبة الى معادلة ألأنتشار في التربة.كانت نتائج الجرع ألأشعاعية عالية قرب منطقة أختراق أطلاقة اليورانيوم, وكانت معتدلة وقليلة نسبيا في نماذج الترب والقطع المعدنية.أعلى تركيز لليورانيوم المنضب في نماذج التربة كانت في محافظة الناصرية. وأن هذه التراكير ستكون أقل من مستوى الخطر بحلول عام 2008.

Keywords


Article
Treatment of Depleted Uranium Contamination in Soil by Using Sodium Bicarbonate Solution

Authors: Ali Sh. M. H. Al-Attar --- Ahmed A. Mohammed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2007 Volume: 13 Issue: 4 Pages: 2090-2108
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The Depleted Uranium contamination in soil was treated with chemical leaching method by using sodium bicarbonate with respect to the effect of several variables (Time, Temperature, Bicarbonate Concentration, Carbonate/Bicarbonate Ratio, Oxidative Reagent Effect, pH, Soil/Solution Ratio and Rinsing Effect after treatment) in order to decontaminate or remove Depleted Uranium to acceptable regulatory levels.The objective is to reach a selectively extracted Depleted Uranium by using a soil washing/extraction without generating a secondary waste which would be difficult to manage and/or dispose off. Results of Depleted Uranium removal efficiency were ranged from (35.4-88.25) %.

التلوث الناجم عن اليورانيوم المنضب في التربة عولج بإستخدام طريقة الغسل الكيمياوي بواسطة بيكاربونات الصوديوم أخذاً بنظر الإعتبار تأثير متغيرات عديدة ( الزمن, درجة الحرارة, تركيز البيكاربونات, نسبة الكاربونات الى البيكاربونات, تأثير العامل المؤكسد, الأس الهيدروجيني(pH), نسبة التربة الى المحلول, تأثير الشطف بعد المعالجة) لازالة او معالجة التلوث الناجم عن اليورانيوم المنضب وصولا الى نتيجة تكون ضمن الحدود المسموحة.الهدف كان ايضا انتقاء طرقة معالجة بالغسل الكيمياوي لا تولد تلوثا ثانويا كبيرا يصعب التخلص منه.نتائج كفاءة الأزالة تراوحت ما بين (35,4 الى 88,25)%. بالإضافة الى دراسة تأثير ثلاثة محاليل(حامض الكبريتيك, حامض الستريك وبيكاربونات يتبعها حامض الستريك) في عملية المعالجة, وكذلك دراسة تاثير المعالجة بالإذابة على(الحديد و الرصاص) في التربة.أخيراً, تم إيجاد علاقات رياضية خاصة بظروف التجارب التي اجريت ما بين تركيز اليورانيوم المنضب والمتغيرات المذكورة أعلاه.

Keywords


Article
Separation of oil from O/W emulsion by electroflotation technique

Authors: Ali Jassim Mohammed Al-Gurany --- Ahmed A. Mohammed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 3 Pages: 5503 -5515
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Dilute emulsified oil in water (50-500 ppm) was removed by electrocoagulatin and electroflotation process. Effects of various parameters such as current density, initial pH, sodium chloride concentration, different electrodes material, gap, temperature, electrodes surface area, and treatment time on the removal efficiency were studied in batch and continuous mode.It was found that the higher removal efficiency (99%) achieved at pH of 7.5 for Al/Al electrodes while for iron electrodes at pH 8 in the batch mode. The removal efficiency increased and the treatment time decreased with increasing the current density and decreasing the gap distance between electrodes. The removal efficiency was (99%) at 10 min for Al/Al electrodes, (98.6%) at 12 min for Al/St.St. electrodes, and (97.4%) at 12 min for Fe/St.St. electrodes. The present results showed that the best temperature was 60ºC .The best concentration of sodium chloride was found to be (400 ppm) when the oil concentration was (500 ppm). Also it was found that a vertical Al/Al electrode was the best type with an electrical energy consuming (3.36 kWh/m3). In the continuous experiments, the removal efficiency enhanced with increasing flow rate. A multiple linear regression model was used in order to relate experimental data to a statistical model with a correlation coefficient of (0.909) and variance (0.827).

الزيت المستحلب في الماء (50-500 ppm) فصل بطريقة التطويف الكهربائي . تم دراسة تأثير عدة متغيرات مثل كثافة التيار,الدالة الحامضية ,تركيز كلوريد الصوديوم,نوعية الاقطاب ,درجة الحرارة,المساحة السطحية ,المسافة بين الاقطاب ,وزمن المعالجة على كفاءة ازلة الزيت وبأسلوب الوجبة. ومن التجارب وجد ان اعلى كفاءة (99%) وبدالة حامضية (pH=7.5) لاقطاب Al/Al اما بالنسبة لاقطاب Fe/St.St عندما تكون الدالة الحامضية هي (pH=8). وقد تبين ان كفاءة الازالة تزداد وزمن المعاجة يقل بزيادة كثافة التيار الكهربائي في حين عند زيادة المسافة بين الاقطاب يؤدي الى نقصان كفاءة الازلة مع زيادة زمن المعالجة. ومن خلال النتائج المختبرية الكفاءة المستحصلة (99%) بزمن (10 min) لاقطاب Al/Al وكفاءة (98.6%) وزمن (12 min) بالنسبة لاقطاب Al/St.St.واما اقطاب Fe/St.St.تكون الكفاءة (97.4%) وزمن (12 min).أفضل درجة حرارة هي (60 ºC) وأفضل تركيز لملح كلوريد الصوديوم هو(400 ppm) .ونستنتج من التجارب المختبرية ان اقطاب Al/Al العمودية هي الافضل باسنهلاك للطاقة الكهربائية بمقدار (3.36 kWh/m3).وجد ان كفاءة الازالة تتحسن مع زيادة الجريان.من خلال احتساب الانحدار اللاخطي المتعدد للنتائج المختبرية تم ايجاد معادلة تربط كافة المتغيرات المدروسة وبمعامل تصحيح (90.9%) وتباين (82.7%).

Listing 1 - 10 of 20 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (20)


Language

English (17)

Arabic (2)


Year
From To Submit

2018 (2)

2017 (1)

2016 (1)

2015 (4)

2014 (3)

More...