research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Wastewater treatment modeling using combined system bio-filter with activated sludge
نمذجة معالجة مياه الصرف الصحي باستخدام نظام مدمج: المرشح الحيوي مع الحماة المنشطة

Author: Ahmed Samir Naje احمد سمير ناجي
Journal: Albahir journal مجلة الباهر ISSN: 23125721 Year: 2019 Volume: 10 Issue: 19-20 Pages: 87-100
Publisher: AL-Abbas Holy Shrine العتبة العباسية المقدسة

Loading...
Loading...
Abstract

The purpose of this article is evaluation of the possibilities of using denitrifyingdephosphatation to enhance biogenic compounds’ removal in the wastewatertreatment plant with separated nitrification on fixed-film. The analysis was basedon the multi-variant simulations of the combined system: fixed film activatedsludge performance. Activated sludge ASIM 2d model related with the modelof pollutions transformations in fixed film was used. The results of exploitationanalyses were performed according to the input parameters: average daily rateof wastewater, pH, COD values, total suspended solids, total Kjeldahl nitrogen,nitrate nitrogen, total phosphorus and alkalinity. The results indicated that thereis a possibility of including fixed film in the activated sludge technology in orderto improve nitrogen and phosphorus removal from the wastewater. Nitrificationprocess will be performed in fixed-film, whereas nitrogen and phosphorus removalfrom the wastewater will be performed in anoxic chambers which operate in theactivated sludge technology. Denitrifying dephosphatation process guaranteesthe high level of total phosphorus reduction (81%), but only if the whole easilydecomposable substrate will be consumed by microorganisms in the anoxicchamber and if enough nitrates will be present in the environment.

الغرض من هذه المقالة هو تقييم إمكانيات إزالة النتروجين والفوسفات لتعزيز إزالة المركبات البيولوجية فيمحطة معالجة مياه الصرف الصحي باستخدام النترجة المنفصلة على الأغشية الثابتة. استند التحليل على محاكاة عدةالمرتبط ASIM 2d متغيرات للنظام المدمج: أداء الحمأة المنشطة بالغشاء الثابت. تم استخدام موديل الحمأة المنشطبموديل تحولات الملوثات في الغشاء الثابت. أجريت نتائج التحاليل وفق ً ا لمعايير المدخلات: المعدل اليومي لمياهالصرف الصحي، درجة الحموضة، المتطلب الكيمايائي للاوكسجين، قيم العوالق الصلبة الكلية، النتروجين الكلي،نيتروجين النيترات، الفوسفور الكلي، والقلوية. أشارت النتائج إلى إمكانية تضمين الغشاء الثابت في تكنولوجياالحمأة المنشطة لتحسين إزالة النيتروجين والفوسفور من مياه الصرف الصحي. تم إجراء عملية النترجة في غشاءثابت، في حين تم تنفيذ إزالة النيتروجين والفوسفور من مياه الصرف الصحي في غرف الأكسدة التي تعمل بتقنيةالفوسفور بنسبة (% 81 )، ولكن فقط ￯ الحمأة المنشطة. تضمن عملية ازالة النتروجين والفوسفات الى هبوط مستوإذا استهلكت الكائنات الدقيقة الموجودة في حجرة الأكسدة بسهولة الطبقة التحتية القابلة للتحلل وإذا كانتهناك نترات كافية.


Article
FIRE FLAME EFFECT ON THE STRENGTH OF SELF – COMPACTING CONCERETE
تأثير لهب النار على مقاومة الخرسانة ذاتية الرص

Loading...
Loading...
Abstract

This study aims to investigate the effect of fire flame on some mechanical properties of self-compacting concrete specimens. To determine the workability, different test methods are adopted in this research such as slump-flow, T50 slump-flow, L-box, U-box and V-funnel. The concrete specimens were subjected to fire flame at the lower surface only to reach temperatures around 400,500 and 600 °C for one hour, then they were cooled gradually to room temperature. After that, they were tested for weight loss, compression, splitting and flexural and compared with specimens not subjected to fire flame (reference mix). Based on the results of this work, it may found that the compressive strength of self- compacting concrete decreases with fire temperature exposure. The residual values of compressive strength were (71-88) % of the strength for the reference specimens. The flexural strength is more sensitive to fire flame temperatures. The residual flexural strengths were in the range of (58- 81) % of the flexural strength for the reference specimens. The splitting tensile strength was extra sensitive than the compressive strength. The residual splitting tensile strength were in the ranges of (58- 90) % of the splitting strength for the reference specimens. The weight loss of concrete specimens increases with increasing fire temperature. The reduction in weight loss ranged between (3.47-6.17) % relative to reference specimens.

تهدف هذه الدراسة للتحقق من تأثير لهب النار على بعض الخواص الميكانيكية للخرسانة ذاتية الرص. لقياس قابلية التشغيل, استخدمت عدة طرق منها فحص الانسياب, زمن الانسياب, الصندوق على شكل حرف L, الصندوق على شكل حرف U, القمع على شكل حرف V. تم تسليط لهب النار على السطح السفلي للنماذج الخرسانية للوصول الى حرارة 400 ,500 و 600 م0 لمدة ساعة واحدة, بعدها تم تبريد النماذج تدريجيا الى درجة حرارة الغرفة. تم قياس فقدان الوزن, الانضغاط, الانشطار والانثناء للخرسانة ذاتية الرص ومقارنتها مع نماذج غير معرضة الى النار (خلطة مرجعية).بناءا على النتائج, تناقصت مقاومة الانضغاط بزيادة التعرض الى درجة الحرارة. القيم المتبقية لمقاومة الانضغاط كانت تتراوح بين (71 – 88) % قياسا الى الخلطة المرجعية, كما وجد ان مقاومة الانثناء حساسة اكثر الى حرارة لهب النار. وان القيم المتبقية لمقاومة الانثناء تراوحت بين (58 – 81) % قياسا الى الخلطة المرجعية. مقاومة الانشطار وجدت بانها حساسة اكثرمن مقاومة الانضغاط الى حرارة لهب النار. حيث كانت القيم المتبقية لمقاومة الانشطار تتراوح بين (58 – 90) % قياسا الى الخلطة المرجعية. كما لوحظ ان النقصان بالوزن يزداد بزيادة درجة حرارة الحرق. وتراوحت قيم النقصان بالوزن بين (3,47 -6,17) % قياسا الى الخلطة المرجعية.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2019 (1)

2013 (1)