research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Optical modeling and analysis of polyurethane lens for correcting presbyopia by using Zemax program
النمذجة البصرية وتحليل عدسة البولي يوريثان لتصحيح طول النظر الشيخوخي باستخدام برنامج زيماكس

Authors: Ali.H.Alhamdani --- Rajaa A.Madlool2 --- Maha. R. Abdul-Hussein2
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2018 Volume: 16 Issue: 1 Pages: 261-270
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

This study aims to design an optical system based on the model of Liu & Brennan by using Zemax EE2006 program. This model was selected because it more accurately reflects anatomical and visual data as compared to the physiological eye model. Polyurethane lens (Pu) is designed for patients with presbyopia patients by using multi-configuration function in Zemax. According to human eye structure, three distances were defined, namely, far (10.0+09mm), middle (1000mm), and near (500mm), to simulate the position of the body, investigate the difference in image received by the eye, and determine the effect of visual defect on image quality. Several techniques have been adopted in the Zemax program to evaluate the visual design efficiency and the magnitude of the difference in the image before and after lens insertion. Results showed that bi-focal polyurethane lens exhibited good performance for far and intermediate distances.

تهدف هذه الدراسة إلى تصميم نظام بصري يعتمد على نموذج ليو وبرينان باستخدام برنامج زيماكس EE2006. تم اختيار هذا النموذج لأنه يعكس بشكل أكثر دقة البيانات التشريحية والبصرية بالمقارنة مع نموذج العين الفسيولوجية. تم تصميم عدسة البولي يوريثان (Pu) للمرضى الذين يعانون من مرض طول النظر الشيخوخي باستخدام وظيفة متعددة التكوين في زيماكس. وفقا لبنية العين البشرية، تم تحديد ثلاث مسافات، وهي بعيدة (10.0 + 09ملم)، والمتوسطة (1000ملم)، وقرب (500 ملم)، لمحاكاة موقع الجسم، والتحقيق في الفرق في الصورة التي تلقاها العين، و تحديد تأثير الخلل البصري على جودة الصورة. وقد اعتمدت العديد من التقنيات في برنامج زيماكس لتقييم كفاءة التصميم البصري وحجم الفرق في الصورة قبل وبعد العدسة الإدراج. وأظهرت النتائج أن عدسة البولي يوريثان ثنائية البؤرة اظهرت الأداء الجيد للمسافات البعيدة والمتوسطة


Article
Effect concentration on spectral properties of Rhodamin 6G dye

Authors: Yasmeen Z. Dawood --- Ali H. alhamdani --- Mustafa M. Jaber مصطفى محمد جابر
Journal: Journal of College of Education مجلة كلية التربية ISSN: 18120380 Year: 2016 Issue: 5 Pages: 455-462
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The spectral properties (absorption and fluorescence) of R6G dye dissolved in acetone were studied for different concentrations (5x10-6, 1x10-5, 5x10-5, 1x10-4, and 5x10-4) mol/l. The results showed that, increase in the absorption intensity with the increased concentration which are found in agreement with Beer – Lambert law. And, shift the absorption and fluorescence spectrum with increase the concentration of the sample. The quantum efficiency of the R6G dye solution were (98.53%, 97.55%, 71.7%, 51.24, and 33.27%) for all concentration respectively, and also, the overlap between the absorption spectrum and the fluorescence decreases with increasing concentration, which, can be due to increase of stokes shift, with increases concentration of the dye solution and this case reduce self-absorption process.

تم دراسة الخصائص الطيفية (الفلورة والامتصاصية) لصبغة الرودامين 6G المذابة في مذيب الاسيتون ولتراكيز مختلفة (5x10-6, 1x10-5, 5x10-5, 1x10-4, 5x10-4) مول/لتر, واشارت النتائج الى زيادة شدة الامتصاص بزيادة التركيز وهذا يفق مع قانون بير-لامبرت. وكذلك, ازاحة كل من طيف الامتصاصية والفلورة مع زيادة التركيز. وكانت الكفاءة الكمية للمحلول (%98.53 , %97.55 , %71.7 , %51.24 و %33.27) للتراكيز على التوالي, وكذالك لوحظ نقصان في التداخل بين طيف الامتصاص والفلورة بسبب زيادة ازاحة ستوكس بزيادة التركيز وهذا يقلل من عملية الامتصاص الذاتي.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2018 (1)

2016 (1)