research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
The Penetration Parameter (λ) for Anomalies (M1) conversion in and
معلم الاختراق (λ) للتحول (M1) الشاذ في النوى و

Author: Ammar A. A. Al-Battawy عمار عبد عبدالله البطاوي
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2010 Volume: 15 Issue: 2 Pages: 297-301
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

In this work, the anomalies in internal conversion coefficients of 312 keV and 296 keV nuclei for M1 conversion are studied by calculating the values of nuclear penetration parameters which indicates as anomalies in internal conversion.The anomalies in was a large, which leads the ratio of deformed in to be large, this means that the M1 conversion is a strongly hindered, while for the anomalies was small, therefore the ratio of deformed is very small and there are no hindered in the M1 conversion.

تم في هذا البحث دراسة الشذوذ في معاملات التحول الداخلي للنواتين عند طاقة مقدارها (312 keV) و عند طاقة مقدارها (296 keV) للتحول الخاص بثنائي القطب المغناطيسي M1 بواسطة حساب قيم معلم الاختراق النووي والذي يعد المؤشر الخاص بالشذوذ في معاملات التحول الداخلي وكان الشذوذ في النواة كبيراَ وهذا يدل على أن نسبة التشوه في النواة كبيرة جداَ مما يعني وجود إعاقة شديدة في انتقالات ثنائي القطب المغناطيسي , أما الشذوذ في نواة فقد كان صغيرا جدا وهذا يدل على أن نسبة التشوه في النواة قليلة جدا ولهذا لا تظهر أي إعاقة في انتقالات ثنائي القطب المغناطيسي .

Keywords


Article
Effect of The X- Ray Exposure Time on the Nuclear Track Detector CR-39
تأثير زمن التعرض للأشعة السينية على كاشف الأثر النووي CR-39

Author: Ammar A. A. Al-Battawy عمار عبد عبدالله البطاوي
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2009 Volume: 14 Issue: 1 Pages: 124-129
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The effect of X-rays of various exposure times on the alpha particles tracks diameters , tracks growth velocity and the tracks appearing time is investigated using the CR-39 nuclear track detector. Increasing the X–rays exposure time is found to improve the above mentioned parameters . The detector sensitivity to X-ray exposure preceded by alpha particles irradiation is better than being followed by that irradiation Also . The detector thickness played a clear role in the response , thin detector responds better than thick detector .

درس تأثير الأشعة السينية بأزمان تعرض مختلفة على أقطار آثار جسيمات الفا وسرعة نمو الآثار وزمن ظهورها باستخدام كاشف الأثر النووي CR-39. وجد أن زيادة زمن التعرض للأشعة السينية يحسن المعلمات المذكورة. إن حساسية الكاشف للتعرض للأشعة السينية المسبوق بالتشعيع بجسيمات ألفا هي أفضل مما لحالة تشعيع ألفا اللاحق. كما لعب سمك الكاشف دوراً واضحاً في استجابته ، فالكاشف الرقيق يستجيب أفضل من الكاشف السميك.

Keywords

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2010 (1)

2009 (1)