research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Effect of solid mixing ratio and temperature on the performance of dry anaerobic composting (Dranco) reactors treating domestic solid wastes(Arabic)
تأثير نسبة المزج ودرجة حرارة التشغيل على كفاءة الإزالة ومستوى إنتاج الغاز في مفاعلات المعالجة البيولوجية اللاهوائية الجافة (DRANCO) المستخدمة في معالجة النفايات المنزلية الصلبة

Authors: Roa'aModhaffarYounis رؤى مظفر يونس --- Dr. Kossay K. Al-Ahmady د. قصي كمال الدين الأحمدي
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2012 Volume: 20 Issue: 5 Pages: 14-24
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractIn thisresearch, an experimental plant was operated in order to study the effect of solid mixing ratio and temperature on the performance of dry anaerobic composting (Dranco) reactors treating domestic solid wastes.The experimental plants consists of four reactors, which were operated under different temperatures of 35oC, 45oC, 55oC, and 65oC , for the first, second, third and fourth system respectively. Three of these reactors were used to treat food waste at different solid mixing ratios of 40%, 50% and 60% for the first, second and third reactor respectively, while the fourth one was used to treat processing vegetable, fruit and garden waste (VFG) with the solid mixing ratio of 50%. The result of researchrevealed that, both of the removal efficiency of COD and the volume reduction of waste increase with increasing the temperature.Higherremoval and volume reduction were recorded at 65oC. In contrast, there was no significant effect of the solid mixing ratio on the removal efficiency and the volume reduction. The study also shows that the total volume of biogas produced per kg of solids were (2.4, 2.44, 2.7 and 1.26 L/Kg for the first, second, third and fourth reactor respectively.Key words: Solid waste, Dranco, Anaerobic treatment, Biogas, Temperature, Solid ratio

الملخصتم في هذا البحث إنشاء وتشغيل محطة اختباريه لغرض دراسة تأثير نسبة المزج ودرجة حرارة التشغيل على كفاءة الإزالة ومستوى إنتاج الغاز في مفاعلات المعالجة البيولوجية اللاهوائية الجافة المستخدمة لمعالجة النفايات المنزلية الصلبة. تألفت المحطات الاختبارية من أربعة منظومات تعمل بدرجات حرارية منتخبة هي 35°C، 55°C، 45°C و 65°C للمنظومات الأولى والثانية والثالثة والرابعة وعلى التوالي، حيث احتوت كل منظومة على أربعة مفاعلات استخدمت ثلاثة منها لمعالجة فضلات الطعام التقليدية المطبوخة وباستخدام نسب مزج 40%، 50% و 60% للمفاعلات الأول والثاني والثالث على التوالي، في حين استُخدِم المفاعل الرابع في معالجة فضلات الحدائق والفواكه والخضراوات وبنسبة مزج صلبة 50%. أثبتت نتائج البحث زيادةكفاءة إزالة المتطلب الكيماوي للأوكسجين (COD) مع ارتفاع درجات الحرارة، حيث تم الحصول على أعلى كفاءة إزالة عند درجة حرارة 65°C، كذلك ازدادت نسبة انخفاض حجم الفضلات مع ازدياد درجات الحرارة، إذ انخفض الحجم إلى أكثر من النصف عند نفس الدرجة الحرارية.كما لم يلاحظ وجود تأثير واضح لنسبة مزج الفضلات الصلبة على نسب إزالة المتطلب الكيماوي للأوكسجين (COD).كذلك وأثبتت النتائج إمكانية الحصول على غاز حيوي عند توفر الظروف الملائمة للتشغيل حيث بلغمعدل إنتاج الغاز لكل وحدة من الفضلات(2.7 لتر/كيلوغرام، 2.44 لتر/كيلوغرام، 2.4 لتر/كيلوغرام) في المفاعلات البيولوجية اللاهوائية التي تعالج الفضلات المنزلية وبنسب مزج (60%، 50% و 40%)وعلى التوالي، في حين يبلغ معدل إنتاج الغاز الحيوي في المفاعلات البيولوجية التي تعالج فضلات الحدائق والفواكه والخضراوات (1.26 لتر/كيلوغرام).


Article
Effect of Using Anaerobic Selectors on the Performance of Continuous Flow Activated Sludge Systems
تأثير استخدام الأحواض الانتقائية اللاهوائية على كفاءة أنظمة الحماة المنشطة المستمرة الجريان-عربي

Authors: Dr. Kossay K. Al-Ahmady د. قصي كمال الدين الأحمدي --- HananHaqeIsmaeel حنان حقي إسماعيل
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 6 Pages: 88-99
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractIn this research, four experimental plants have been constructed and operated in order to study the impact of using the anaerobic selectors on the behavior and efficiency of the extended aeration activated sludge system. The study program was divided into three stages. In the first stage, the experimental plants were run on the hydraulic retention time of the aerobic reactor equals to (32) hours, whereas, the hydraulic retention times in the biological aerobic reactors for the second and the third stages were (24 and 18) hours respectively. The results of the study revealed that; adding the anaerobic selectors improves the properties of the aerobic biological treatment in terms of removing soluble organic materials (CODs) and the efficiency of removing phosphor (PO4). The results also showed that,the organic and phosphorus removal efficiency increases with increasing the hydraulic retention time of the anaerobic selector. In contrast the values of the sludge volume index (SVI) decreases with this increasing. Higher removal efficiencies were recorded in the experimental stations that include anaerobic selector, which operates on a hydraulic retention time of (120 min) followed by the plant with the selector of (60 min) detention time and in the last place the plant that include selector, which operates on a hydraulic retention time of (30 min).Keywords:Anaerobic selector, Activated sludge, HDT,SVI, Phosphorus removal, Organic removal

الملخصتم في هذا البحث إنشاء وتشغيل محطة اختباريه تتكون من أربعة مفاعلات بيولوجية لغرض دراسة تأثير استخدامالأحواض الانتقائية اللاهوائية على سلوك وكفاءة أداء وحدات الحماة المنشطة المستمرة الجريان.قسم برنامج العمل إلى ثلاثة مراحل تم في المرحلة الأولى تشغيل الوحدات الاختبارية على وقت تعويق هيدروليكي للمفاعل الهوائي يساوي (32 ساعة)، في حين كان وقت التعويق الهيدروليكي في المفاعل البيولوجي الهوائي وللمرحلتين الثانية والثالثة مساويا لـ (24 و 18 ساعة) وعلى التوالي.أثبتت نتائج البحث إن إضافة الأحواض الانتقائية اللاهوائية يحسن من خصائص المعالجة البيولوجية الهوائية من حيث إزالة المواد العضوية الذائبة والفسفور والخصائص الترسيبية للحماة البيولوجية. كذلك أظهرت النتائج أن هناك علاقة بين زيادة وقت التعويق الهيدروليكي للحوض الانتقائي اللاهوائي وكفاءة إزالة كل من المواد العضوية والفسفور وتحسين خصائص الحمأة حيث تزداد كفاءة إزالة المواد العضوية والفسفور مع زيادة وقت التعويق الهيدروليكي للأحواض الانتقائية اللاهوائية، بالمقابل تقل قيمة معامل دليل الحماة الحجمي مع زيادة وقت التعويق الهيدروليكي للأحواض الانتقائية،حيث لوحظ أن أفضل كفاءة إزالة واقل معامل دليل حماة حجمي (SVI) تحقق في المحطة الاختبارية الحاوية على حوض انتقائي يعمل بوقت تعويق يساوي (120) دقيقة تليها المحطة الاختبارية ذات الحوض الانتقائي اللاهوائي الذي يعمل بوقت تعويق يساوي (60) دقيقة ثم المحطة ذات الحوض الانتقائي الذي يعمل بوقت تعويق يساوي (30) دقيقة.


Article
Assessment of Air Particulate Pollution in New Badoosh Cement Factory/ Iraq
تقييم مستويات التلوث بالدقائق الهوائية في مصنع سمنت بادوش الجديد/ العراق

Authors: Dr. Kossay K. Al-Ahmady د. قصي كمال الدين الأحمدي --- Hussain Muhsin Obeed, حسين محسن عبيد
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2015 Volume: 23 Issue: 3 Pages: 123-135
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

In this research, measurements of total (TSP) and fine suspended particulate PM1, PM2.5, PM7 and PM10atBadoosh cement factory were carried out. Seventeen locations inside the factory are selected. The effect on soil around the cement factory was also studied by collecting samples in the four directions North, South, East and West to a distance of five kilometers from the factory with one kilometer spacing. The result of the study revealed that;the concentration of very fine suspended particulate PM2.5 was over the international standard limits at different locations of the factory and the overall average concentration for the factory was (47 g/m3). For PM10 suspended particulates, the results at all locations were over the international limits and the overall average concentration reached 869 g/m3, which was much more than the standards of 150 g/m3. On the other hand, the total suspended particulate concentration exceed the standard at several locations in the factory. Significant correlations were found among the suspended particulate concentrations according to their size.The results of soil test around the cement factory showed significant differences of oxides percentages among the directions. Higher percentages were recorded in the South and East directionsthan North-West direction. The results also revealed that the percentages of SiO2 and Al2O3 were 40.94% and 10.53% in the east direction whereas higher percentage for Fe2O3 (4.86%), CaO (36.81%), MgO (4.49%),and SO3(0.76%) were recorded in the south direction of factory.

تم في هذا البحث اجراء قياسات مستويات الغبار العالق الكلي والناعم (PM1, PM2.5, PM7, PM10) في 17 موقع مختار في معمل اسمنت بادوش الجديد كما وتم جمع نماذج من التربة حول المعمل بالاتجاهات الاربعة على مسافات 1 كيلومتر ولحد 5 كيلومتر في كل اتجاه لبيان تأثير الساقط الغباري على التربة المحيطة. أظهرت نتائج القياس تجاوز تركيز الدقائق العالقة الناعمة جدا (PM2.5) المحددات القياسية في عدة مواقع من المعمل كما تجاوز المعدل الكلي للمعمل المحددات القياسية وبلغ 47 مايكروغرام/م3، أما تراكيز الدقائق العالقة للقابلة للاستنشاق (PM10) فقد تجاوزت المحددات القياسية في جميع مواقع القياس حيث بلغ التركيز الاجمالي 869 مايكروغرام/م3 مقابل 150 مايكروغرام للمواصفات القياسية، كذلك تجاوزت تراكيز الدقائق العالقة الكلية في عدة مواقع المحددات القياسية المعتمدة. كذلك سجلت النتائجوجود علاقات ارتباط معنوية بين تراكيز الدقائق العالقة حسب أحجامها. كما أظهرت نتائج فحوصات التربة حول معمل السمنت اختلافات معنوية بين نسب الاكاسيد المقاسة فيها وكانت نسب الاكاسيد أعلى في اتجاهي الجنوب والشرق وبفرق معنوي عن الشمال والغرب حيث كانت نسبة (ٍSiO2) و (Al2O3) في التربة شرقي المعمل هي الاعلى وبلغت 40.94% و10.53% على التوالي، في حين كان اعلى معدل لبقية الاكاسيد في التربة باتجاه جنوبي المعمل وبلغ 4.86% لـ (Fe2O3) و36.81% لـ (CaO) و4.49% لـ (MgO) و0.76% لـ (SO3).


Article
Performance Study of the Single and Double Stages Anaerobic Biological Filters in Treating Domestic Greywater
دراسة كفاءة المرشح البيولوجي اللاهوائي ذو المرحلة الواحدة وذو المرحلتين في معالجة المياه الرمادية المنزلية

Loading...
Loading...
Abstract

AbstractIn this paper, a laboratory plant was constructed and operated in order to assess the effect of stages; detention times and depth of filter on the performance of the upflow anaerobic biological filter that treating domestic grey water. The experimental plant was consisted of two upflow anaerobic filters; the first one operates with a single stage, while the second one was with two stages. Crushed gravels were used as a medium for growing the biological organisms. The two filters were worked simultaneously in continuous flow regime at hydraulic detention times of 12, 18 and 24 hours using greywater samples with COD concentration between 190-350 mg/l. The results showed that the two stages filter was more efficient than the single stage filter. The COD and BOD removals were (55.5, 62.7, 75.3)% and (57.2, 67.4, 78.2)% for the detention times of (12, 18 and 24) hours respectively. While the COD and BOD removals were (67.7, 54.8, 39.1)% and (73.2, 60.5, 44.8)% for the first filter and at the same detention times respectively. The two filters were also efficient in removing the suspended solids. Increasing depth of filter has a little influence on the performance efficiency. Depth of (0.3) m was considered the most effective height by which the quickest COD removal is performed.

الملخصتم في هذا البحث إنشاء وتشغيل محطة مختبريه لغرض دراسة تأثير مراحل الترشيح، وقت المكوث الهيدروليكي وعمق المرشح على سلوك وكفاءة المرشحات البيولوجية اللاهوائية ذات الجريان نحو الأعلى في معالجة المياه الرمادية المنزلية. اشتملت المحطة الاختبارية على مرشحين بيولوجيين الأول ذو مرحلـة واحـدة والثاني ذو المرحلتين حيث استخدم الـحصى المكسر كوسط لنمو الأحياء المجهرية. تم تشغيل المرشحين وفقاً لنظام التغذية المستمرة باستخدام نماذج مياه رمادية منزلية ذات تراكيز COD تراوحت ما بين (190-350) ملغم/لتر وبأوقات مكوث هيدروليكية قدرها 24 و18 و12 ساعة. أظهرت النتائج تفوق المرشح البيولوجي اللاهوائي ذو المرحلتين خصوصا عند زيادة الحمل الهيدروليكي والعضوي المسلط. إذ بلغت نسبة إزالة كل من COD و BOD في المرشح البيولوجي ذو المرحلتين (75.3 ، 62.7 ، 55.5)% و (78.2 ، 67.4 ، 57.2)% عند أوقات مكوث (24 و18 و12) ساعة على التوالي. في حين كانت نسبة إزالة الـ COD والـ BOD في المرشح البيولوجي اللاهوائي الأول (67.7 ، 54.8 ، 39.1)% و (73.2 ، 60.5 ، 44.8)% وعند نفس أوقات المكوث وعلى التوالي. كذلك أظهرت النتائج كفاءة هذه المرشحات في إزالة المواد الصلبة العالقة. كما أثبتت النتائج أن ارتفاع المرشح البيولوجي لا يعد عاملا مؤثرا حيث لوحظ بان أسرع إزالة COD تحدث عند ارتفاع (0.3) متر.


Article
Effect of Hydraulic Detention Time and WaterTemperature onthe Removal Efficiency of Organic and Nutrients Pollutants InDuckweed Based Wastewater Stabilization Ponds
تأثير تغيير وقت المكوث الهيدروليكي ودرجة حرارة الماء في كفاءة إزالة الملوثات العضوية والمغذيات في برك الأكسدة المغطاة بنباتات عدس الماء-عربي

Authors: Dr. Kossay K. Al-Ahmady د. قصي كمال الدين الأحمدي --- ZenaA. AL-Shrefy زينة عامر إدريس أحمد الشريفي
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 5 Pages: 63-73
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThis study deals with the effect of some operational parameters on the removal efficiency and behavior of duckweed based wastewater stabilization ponds. The results of the study showed that; covering the oxidation ponds with duckweed improve their ability to treat higher organic and nitrogenous loads. In addition, there is a relationship among the hydraulic detention time and each of the removalefficiency of organic and nutrients. Decreasing the hydraulic detention time decreases the removal efficiency of organic.On the other hand, the results of research also showedthat; increasing nitrogen and phosphor load leads to decrease removal efficiency of nitrate, nitrite, and phosphate, and increases removal efficiency of ammonia. Temperatures have also impact on the organic and nutrients removal and the concentration of dissolved oxygen in effluent. Highest removal and dissolved oxygen concentrations were recorded at the temperature of (26°C), and these values decrease with increasing or decreasing the temperatures.Keywords: Duckweed; Stabilization ponds; Nutrient removal; HDT;Temperature

الخلاصةيتناول البحث دراسة تأثير بعض العوامل التشغيلية على كفاءة إزالة الملوثات العضوية والمغذيات في برك الأكسدة المغطاة بنباتات عدس الماء.أثبتت نتائج البحث أن تغطية برك الأكسدة بعدس الماء تحسن من خصائص المعالجة البيولوجية من حيث إزالة المواد العضوية والمغذياتبثبوت وقت المكوث الهيدروليكي ودرجة الحرارة.كما أن هناك علاقة بين انخفاض وقت المكوث الهيدروليكي لبرك الأكسدة البيولوجية المغطاة بعدس الماء وغير المغطاة به مع كفاءة إزالة كل من المواد العضوية والنتروجينية والفوسفات, إذأظهرت النتائج انخفاض كفاءة إزالة كلاً من المركبات العضوية والنتروجينية والفوسفات مع انخفاض وقت المكوث الهيدروليكي.من جانب آخر, بينت نتائج البحث وجود اختلاف في كفاءة إزالة المواد العضوية والمغذيات مع اختلاف درجات الحرارة, إذ سُجِّلتأعلى كفاءة إزالة للمواد العضوية عند درجة حرارة (26 درجة سيليزية) وتقل كفاءة الإزالة عند ارتفاع أو انخفاض درجة الحرارة. وسُجِّل أعلى تركيز أوكسجين مذاب عند درجة حرارة (26 درجة سيليزية) وانخفض التركيز تدريجياً عند درجات حرارة (32 و 18 ) درجة سيليزية وعلى التوالي.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

Arabic (5)


Year
From To Submit

2015 (1)

2013 (2)

2012 (1)

2011 (1)