research centers


Search results: Found 14

Listing 1 - 10 of 14 << page
of 2
>>
Sort by

Article
EFFECT OF DUST AND SHADOW ON THE EFFICIENCY OF PHOTOVOLTAIC SOLAR MODULE AT BAGHDAD CLIMATE CONDITIONS

Author: Emad Talib Hashim
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2013 Volume: 13 Issue: 4 Pages: 769-783
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The performance of a solar cell under sun radiation is necessary to describe the electrical parameters of the cell. The Prova 200 solar panel analyzer is used for to test a solar cell at Baghdad climate conditions (the experimental measurements had been made at weather temperature in the range between 20-28oC and average wind speed 2.5 km/hr). The results showed that as dust accumulated the solar panel loose power for the first three days, but when the dust had created several layers the power dropped in smaller intervals for the forth days to two weeks. More power and efficiency lose for more exposure days and tilt angle 0o ≥ 30o ≥ 60o ≥ 90o(The results show that modules tilted with larger angles let less dust get accumulated on surfaces) at a fixed time (exposure days) for the fourth angles respectively. Sharp reduction of energy (power) is yield up to 63.2-99.8% of PV (photovoltaic) solar cell under 5Ω resistance load was observed as a result of corresponding shaded percentage area of the cells 5.6-50% from the total cell area.

اداء الخلية الشمسية تحت الاشعاع الشمسي ضروري لوصف الخلية .لقد استعمل جهاز محلل اداء الخلية بروفا 200 لاختبار لوح شمسي عند الظروف المناخية لمنطقة بغداد ( القياسات العملية كانت ضمن مدى لدرجة حرارة الجو يتراوح بين 20 الى 28 درجة مئوية) . النتائج بينت ان تراكم الغبار يفقد بعض من قدرة الخلية وللايام الثلاث الاولى وعند تراكم طبقات اخرى من الغبار يكون انخفاض القدرة بقيمة اقل ابتداً من اليوم الرابع الى مدة اسبوعين. يزداد نقصان القدرة والكفاءة مع زيادة تعرض الخلية للايام المغبرة وزاوية الميل عند 0≥ 30 ≥ 60 ≥ 90 درجة (النتائج بينت انه كلما كانت زاوية ميلان الخلية عالية كلما كان تراكم الغبار على سطحها قليل) وعند زمن ثابت للزوايا الاربعة وعلى التوالي. نقصان كبير وحاد لقدرة الخلية المربوطة مع حمل 5 أوم , يتراوح بين 62.2- 99.8 % من قدرة الخلية يمكن مشاهدته كنتيجة لمساحة تظليل ما يقابل 5.6-50 % من مساحة الخلية الكلية.

Keywords

photovoltaic --- solar cell --- dust --- shadow --- power --- efficiency


Article
Critical Volume Prediction of Select Substances

Authors: Emad Talib Hashim --- Yasir Khalil Ibrahim
Journal: Journal of College of Education مجلة كلية التربية ISSN: 18120380 Year: 2010 Issue: 1 Pages: 1-16
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

New generalized formula has been generalized to permit calculation of the critical volume, as a function of critical temperature Tc, critical pressure Pc and molecular weight Mw. This correlation provides accurate and computationally reliable prediction of the critical volume; Vcc with an average absolute error 2.4 % for 34 data points.

عُممت علاقة لإيجاد الحجم الحرج لبعض المركبات وتعتمد على قيمة درجة الحرارة الحرجة والضغط الحرج والورن الجزيئي. هذه العلاقة تعطي تكهن ممتاز وملائم لحساب الحجم الحرج وبمعدل نسبة خطا 2.4% ل 34 نقطة عملية.

Keywords


Article
Prediction of Enthalpy and Internal Energy of Saturated Steam

Authors: Sabah Jebour Al-Janabi --- Emad Talib Hashim --- Zeyad D. Kadhim
Journal: Journal of College of Education مجلة كلية التربية ISSN: 18120380 Year: 2011 Issue: 5 Pages: 137-149
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The main aim of this work is to establish an empirical formula for calculation the enthalpy and internal energy of saturated steam. The use of this formula reflects a good result under saturated steam conditions. In order to obtain this reliable model for calculating these thermodynamic prosperities, a formula is established by nonlinear regression based on experimental data collection, after a thorough survey of literatures. Application of the proposed formula shows that, the average percentage error between the results obtained by this equation and the experimental data, is about (0.58%) for internal energy, and for enthalpy is about (0.64%), for 71 data points at each case.

هدف البحث هو ايجاد علاقة رياضية تجريبية لحساب المحتوى الحراري والطاقة الداخلية للبخار المشبع. استعمال هذه العلاقة عكست نتائج جيدة في ظروف البخار المشبع. ولاجل ان تكون العلاقة اكثر شمولية تم الاعتماد على الاساس اللاخطي الرياضي للنتائج العملية الماخوذة من المصادر.تم تطبيق العلاقة المذكورة واظهرت آلنتائج بان معدل نسبة الخطأ مقارنتا بالنتائج العملية هي (%0.58) للطاقة الداخلية و (%0.64) للمحتوى الحراري ول 71 نقطة عملية لكل حالة.


Article
Generalized Formula for Estimating VUHS Saturated Steam Properties

Authors: Emad Talib Hashim --- Lubna Ghalib --- Yasir Khalil Ibrahim
Journal: Journal of College of Education مجلة كلية التربية ISSN: 18120380 Year: 2011 Issue: 1 Pages: 54-68
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

A simple formula has been developed to predict specific volume V; internal energy U; enthalpy H and entropy S of saturated steam. The use of this formula reflects a good result under saturated steam conditions. In order to obtain this reliable model for the calculating these thermodynamic prosperities (V, U, H and S), the same formula type is established. The formula can be used to calculate the V, U, H and S values for a given saturated temperature with the corresponding saturated pressure. Also an analysis for application of the proposed formula has been made ,where the over all absolute average percentage error are for specific volume (0.69%),internal energy (0.58%) , enthalpy (0.64%) and entropy (0.39%) for 71 data points of each thermodynamic property (V,U,H and S).

تم ايجاد علاقة لحساب الحجم النوعي , الطاقة الداخلية , المحتوى الحر اري والعشوائية الخاصة بالبخار المشبع. استخدام هذه العلاقة يعكس نتائج جيدة في ظروف البخار المشبع. من اجل جعل العلاقة لها مرونة تطبيق تم تثبيت شكل المعادلة للخواص الاربعة .(V, U, H, S) العلاقة تستعمل لحساب الحجم النوعي ،الطاقة الداخلية، المحتوى الحراري والعشوائية لدرجة حرارة والضغط المقابل المشبع. التحليل لتطبيق العلاقة بين ان معدل نسبة الخطا المطلق هي الحجم النوعي( ٦٩.)، الطاقة الداخلية (٥٨.)، المحتوى الحراري ( ٦٤.) والعشوائية (٣٩.) ل ٧١ نقطة عملية على التوالي.

Keywords


Article
A WIDE RANGE FORMULA FOR COMPRESSION FACTOR FUNCTION OF REDUCED PROPERTIES

Loading...
Loading...
Abstract

This paper presents an effort aimed at developing a new formula to calculate compression factor within acceptable error range. A formula has been generalized to permit calculation of the compression factor as a function of reduced properties: reduced temperature TR and reduced pressure PR. The new correlations show improvement in temperature and pressure range which offers flexibility for estimating compression factor for a wide range of reduced temperature; TR=1-5 and reduced pressure ;PR=0.5- 6.5. This correlation provides accurate and computationally reliable prediction of the compression factor (Z) with an average absolute error (AAE) 4.6 % for 169 data points.

البحث الحالي يمثل محاولة لايجاد علاقة لحساب معمل الانضغاطية وبنسبة خطأ معقولة. تم تطبيق العلاقة لحساب معامل الانضغاطية لمدى واسع بالاعتماد على الخواص التناسبية : درجة الحرارة التناسبية (TR ) والضغط التناسبي (PR ) . العلاقة الجديدة حسنت المدى التطبيقي لدرجة الحرارة والضغط والذي ادى لحساب معمل الانضغاطية وفي مدى واسع لدرجة الحرارة التناسبية (TR=1-5 ) والضغط التناسبي (PR=0.5- 6.5). الموديل الجديد يوفر التنبؤ الدقيق والموثوق لحساب معمل الانضغاطية وبمعدل نسبة خطأ مطلق ((4.6 % الخاصة في (169) نقطة عملية.


Article
Dust Effect on the Efficiency of Silicon Mono Crystalline Solar Modules at Different Tilt Angles at Al-Jadryia Climate Conditions
تأثير الغبار على كفاءة وحدات الالواح الشمسية احادية التبلور وبزوايا ميل مختلفة وضمن الظروف المناخية لمدينة الجادرية

Authors: Emad Talib Hashim عماد طالب هاشم --- Tabark Abed Hussien تبارك عبد حسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 2 Pages: 56-73
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Solar energy usage in Iraq is facing many issues; one of those is the accumulation “of the dust on the surface of the solar module which” would highly lower its efficiency. The present work study the effect of dust accumulation” on installing fixed solar modules with different inclined angles 15o, 33o, 45o, 60o. Evaluation of the solar modules performance under different circumstance conditions such as rain, wind and humidity are considered in study of dust effect on solar module performance. The results show that the lowest output average efficiencies of solar modules occurs at 15o horizontally inclined angle are 7.4% , 6.7% , 8.0% , 8.1%, and 8.4% for the corresponding months; June, July, August, October, and September respectively while the highest average efficiencies are 8.9% , 9.1% , 9.4% , 9.6% , 9.6% for an inclined angle 60o for the same month. lose power output rate for angle 15o horizontally inclined solar modules are as following 32.6%, 32%,31.6%,34.9%,26.2% for months; June, July, August, October, and September respectively , while the results for the 60o horizontally inclined solar module are 26.9%, 17%, 24.2%, 28.1%, and 9.7% for the same five months. As a final result is that the 15o horizontally inclined solar panel is less efficient compared with the 60o horizontally inclined solar panel and the difference in the results in the months was mainly due to the weather changes (summer and winter). The solar modules efficiency and lose power rate values for the inclination angles 33o and 45o are ranged between the values of 15oand 60o inclination angles.

أن تطبيقات الطاقة الشمسية في العراق تواجه مشاكل كثيرة, واحدة من أهم هذه المشاكل هي تراكم الغبار على سطح الألواح الشمسية التي تسبب انخفاض أدائها بشكل حاد. في العمل الحالي.تم دراسة ثأثير تراكم الغبار على كفاءة الخلية الشمسية من خلال نصب ألواح شمسية ثابتة بزوايا ميل مختلفة º15º,33, º45,º60 مع الأفق تمت القياسات خارج المختبر. تم تقييم أداء الألواح الشمسية تحت الظروف الجوية مثل هطول الإمطار, العواصف الترابية, الرياح, والرطوبة.تشير النتائج التجريبية إلى أن معدل الكفاءة الخارجة للوح الشمسي المائل بزاوية15ºمع الأفق تصل إلى حوالي , 7.4%, 7.6%, 8%, 8.1%8.4%لأشهر حزيران, تموز,أب, أيلول,تشرين الأول على التوالي. بينما تصل لحوالي , 8.9%, 9.1%, 9.4% 9.6%,9.6% لنفس الأشهر المذكورة سابقا للوح الشمسي المائل بزاوية 60ºمع الأفق. وكنتيجة نهائية فان أقصى قيمة لخسائر القدرة الخارجة للوح الشمسي المائل بزاوية º15 وصلت لحوالي , 32.6%, 32% 31.6%,, 34.9% 26.2 لأشهر حزيران , تموز, آب, أيلول و تشرين الأول على التوالي. بينما وصلت لحوالي 26.9% 17%, 24.2%, 28.1%9.7%لنفس الأشهر المذكورة سابقا للوح الشمسي المائل بزاوية 60º. من هذه النتائج يمكن ملاحظة إن اللوح المثبت بزاوية º15 مع الأفق اقل فعالية مقارنة مع اللوح الشمسي المثبت بزاوية 60 مع الأفق وان تغير النتائج للأشهر المختلفة (الصيف و الشتاء) هو نتيجة التأثر بصورة كبيرة بالظروف الجوية. كفاءة الالواح الشمسية والتي زوايا ميلها 33ºو 45ºوخسارة القدرة محصورة بين قيم النتائج للزاويتيين 15º و60º.


Article
Temperature Effect on Power Drop of Different Photovoltaic Modules
تأثير درجة الحرارة على انخفاض القدرة لأنواع مختلفة من الالواح الفوتوفولتائية

Authors: Emad Talib Hashim عماد طالب هاشم --- Akram Abdulameer Abbood أكرم عبد الأمير عبود
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 5 Pages: 129-143
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Solar module operating temperature is the second major factor affects the performance of solar photovoltaic panels after the amount of solar radiation. This paper presents a performance comparison of mono-crystalline Silicon (mc-Si), poly-crystalline Silicon (pc-Si), amorphous Silicon (a-Si) and Cupper Indium Gallium di-selenide (CIGS) photovoltaic technologies under Climate Conditions of Baghdad city. Temperature influence on the solar modules electric output parameters was investigated experimentally and their temperature coefficients was calculated. These temperature coefficients are important for all systems design and sizing. The experimental results revealed that the pc-Si module showed a decrease in open circuit voltage by -0.0912V/ºC while mc-Si and a-Si had nearly -0.07V/ºC and the CIGS has -0.0123V/ºC. The results showed a slightly increase in short circuit current with temperature increasing about 0.3mA/ºC ,4.4mA/ºC and 0.9mA/ºC for mc-Si , pc-Si and both a-Si and CIGS. The mc-Si had the largest drop in output power about -0.1353W/ºC while -0.0915, -0.0114 and -0.0276 W/ºC for pc-Si, a-Si and CIGS respectively. The amorphous silicon is the more suitable module for high operation temperature but it has the lowest conversion efficiency between the tested modules.

تمثل درجة حرارة الوح الشمسي العامل الثاني الاكثر تاثيراً في أداء المنظومات الشمسية الفوتوفولتائية بعد مقدار الاشعاع الشمسي. يقدم هذا البحث مقارنة اداء لاربع انواع مختلفة من الالواح الفوتوفولتائية : سيليكون احادي التبلور، سيليكون متعدد التبلور، سيليكون غيرمنتظم التبلور ونحاس انديوم )غاليوم( ثنائي السلينايد تحت الظروف المناخية لمدينة بغداد. تم التحقق عمليا من تأثير درجة الحرارة على مخرجات الالواح الشمسية وتم حساب معاملات درجة الحرارة والتي لها التاثير المباشر على تصميم وتقدير سعة المنظومات الفوتوفولتية. بينت النتائج العملية ان لوح السيليكون متعدد التبلور أظهر هبوط في مقدار فولتية الدائرة المفتوحة بمقدار -0.0912 فولت/درجة مئوية، بينما للوحي السيليكون احادي التبلور والسيليكون غير منتظم التبلور -0.07 فولت/درجة مئوية وللوح النحاس كان مقدار الهبوط حوالي -0.0123 فولت/درجة مئوية. كما أظهرت النتائج زيادة طفيفة في تيار دائرة القصر مع زيادة درجة الحرارة بمقدار 0.3 ملي أمبير/درجة مئوية ، 4.4 ملي أمبير/درجة مئوية للوح السيليكون احادي التبلور،السيليكون متعدد التبلور على التوالي و 0.9 ملي أمبير/درجة مئوية لكل من لوحي السيليكون غير منتظم التبلور والنحاس. بالنسبة للقدرة العظمى الخارجة من اللوح الشمسي، لوح السيليكون احادي التبلور اظهر الانخفاض الاكبر من بين الالواح المدروسة بمعامل حرارة حوالي -0.1353 واط/درجة مئوية بينما كان الانخفاض -0.0915،-0.0114 و -0.0276 واط/درجة مئوية للوح السيليكون متعدد التبلور، السيليكون غير منتظم التبلور ولوح النحاس على التوالي.


Article
Experimental and Simulation for the Effect of Partial Shading on Solar Panel Performance
التجربة والمحكاة لتأثير الظل الجزئي على أداء اللوح الشمسي

Authors: Emad Talib Hashim عماد طالب هاشم --- Aseel Jamal Khaled اصيل جمال خالد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 6 Pages: 87-99
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Partial shading is one of the problems that affects the power production and the efficiency of photovoltaic module. A series of experimental work have been done of partial shading of monocrystalline PV module; 50W, Isc: 3.1A, Voc: 22V with 36 cells in series is achieved. Non-linear power output responses of the module are observed by applying various cases of partial shading (vertical and horizontal shading of solar cells in the module). Shading a single cell (corner cell) has the greatest impact on output energy. Horizontal shading or vertical shading reduced the power from 41W to 18W at constant solar radiation 1000W/m2 and steady state condition. Vertical blocking a column of cells (9 cells) in a module reduces the power from 41W to 18W (53% power reduction); while, blocking one or two cell in the row reduces the power from 41 W to 18W (53% power reduction). Shading three or four cells in the same row reduces the power from 41W to 1W or 0.006W (94% power reduction). A complete Matlab / Simulink model are achieved to simulate the effect of partial shading on power output of module. It is found that shading a single cell reduces the power from 50 W to 25 W (50%) using Matlab/Simulink model. Comparisons have been made between the I-V and P-V characteristic curves from the simulation with the practical (experimental) curves. The results showed that the percentage of error between the Simulink results and the corresponding experimental measurement are 22% without shading effect and, 32% with partial shading.

التظليل الجزئي هو احد المشاكل التي تؤثر على الطاقة المنتجة والكفاءة للوح الكهروضوئي .تم اجراء سلسلة من التجارب من الظل الجزئي على وحدة كهروضوئيه من نوع احادية البلورة 50 واط ,3.1 امبير,22 فولت تحتوي 36 خلية مربوطة على التوالي.الاستجابة الغير خطيه للطاقة الناتجة يمكن ملاحظتهاعند تطبيق حالات مختلفه للتظليل الجزئي( افقي ,عمودي).تظليل خليه واحده(خلية الزاوية) لها الاثر الكبير على الطاقة الخارجية.التظليل الافقي او العمودي يقلل الطاقة من 41 واط الى 18واط عند اشعاع ثابت ١٠٠٠وحالة مستقرة . تم التحقق من ان حجب عمود من الخلايا(9خلايا)في الوحده الضوئية يقلل الطاقة من 41 واط الى 18واط (53%تخفيض استهلاك الطاقة ) و حجب خلية او خليتين في الرف الواحد يقلل الطاقة من 41 واط الى 18 واط (53%تخفيض استهلاك الطاقة).) .تظليل ثلاث او اربع خلايا في نفس الرف يقلل الطاقة الى 1واط او 0.006 واط (94%تخفيض استهلاك الطاقة) .تم توضيح تاثير الظل الجزئي ببرنامج السميولنك ماتلاب.تم التحقيق ان تظليل خلية واحده يقلل من الطاقة من ال50واط الى 25واط (50% تخفيض استهلاك الطاقة).عملت مقارنة بين منحنيات (تيار- فولتية)و(طاقة- فولتية)الناتجه من برنانج الماتلاب مع المنحنيات الناتجة من التجارب العملية,وكما هو مبين من النتائج نسبة الخطأ المئوية بين النتائج العمليه والنظرية بدون تأثير الظل تصل الى 22%,ومع تاثير الظل الجزئي تصل الى %32


Article
Synchronous Buck Converter with Perturb and Observe Maximum Power Point Tracking Implemented on a Low-Cost Arduino-microcontroller
المحول التزامني الخافض مع تقنية التتبع والاضطراب لنقطة الطاقة العظمى تنفذ على متحكمة الاردوينو واطئة الكلفة

Authors: Emad Talib Hashim عماد طالب هاشم --- Sarah Adil Mohammed Hussien سارة عادل محمد حسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 2 Pages: 16-33
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Maximum power point tracking (MPPT) is used in photovoltaic (PV) systems to enhance efficiency and maximize the output power of PV module, regardless the variation of temperature, irradiation, and the electrical characteristics of the load. A new MPPT system has been presented in this research, consisting of a synchronous DC-DC step-down Buck converter controlled by an Arduino microcontroller based unit. The MPPT process with Perturb and Observe method is performed with a DC-DC converter circuit to overcome the problem of voltage mismatch between the PV modules and the loads. The proposing system has high efficiency, lower cost and can be easily modified to handle more energy sources. The test results indicate that the use of the proposed MPPT control with the designed synchronous Buck converter increases the PV output power; hence increases the overall solar system efficiency. The synchronous Buck converter test results used in this design showed high converter efficiency up to 95% of the power produced from the solar module, leading to reduce power loss caused by the power transfer process from PV module to the loads.

تقنية تتبع نقطة الطاقة العظمى تستخدم في النظام الفوتوفولتائي لكي تزيد من القدرة المستخرجة من اللوح الفوتوفولتائي بغض النظر عن تأثير درجة الحرارة وحالة الاشعاع الشمسي وخصائص الحمل الكهربائية. طور نظام جديد بتقنية تتبع نقطة الطاقة العظمى في اللوح الفوتوفولتائي يتكون من المحول التزامني الخافض للتيار الكهربائي المستمر والذي يتحكم به وحدات المتحكمة الصغيرة الاردوينو.ان تقنية تتبع نقطة الطاقة العظمى مع طريقة الاضطراب والتتبع قد طبقت مع دائرة المحول التزامني الخافض للتيار المستمر للتغلب على مشكلة عدم توافق الفولتية بين اللوح الفوتوفولتائي والحمل. النظام الناتج لديه كفاءة عالية, كلفة واطئة وممكن بسهولة تحويله لكي يتحمل مصادر فولتية او طاقة اعلى. النتائج العمليه بينت ان استخدام النظام المقترح يتحكم بتقنية تتبع نقطة الطاقة العظمى يزيد من كفاءة الطاقة المستخرجة من اللوح الفوتوفولتائي وبالتالي يزيد من كفاءة النظام الشمسي الكلية. ان نتائج اختبار المحول التزامني الخافض للتيار المستمر المستخدم في هذا التصميم اظهرت كفاءة تحويل عالية للطاقة الماخوذة من اللوح الفوتوفولتائي بنسبة اعلى من 95% وبالتالي قلل من خسائر الطاقه الناتجة من تحويل القدرة من اللوح الفوتوفولتائي الى الحمل.


Article
Modeling and Simulation of Solar Module performance using Five Parameters Model by using Matlab in Baghdad City
النمذجة والمحاكاة لأداء اللوح الشمسي بأستخدام نموذج الخمس عوامل بواسطة الماتلاب في مدينة بغداد

Authors: Zainab Riyadh Talib زينب رياض طالب --- Emad Talib Hashim عماد طالب هاشم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 10 Pages: 15-31
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work presents the modeling of the electrical response of monocrystalline photovoltaic module by using five parameters model based on manufacture data-sheet of a solar module that measured in stander test conditions (STC) at radiation 1000W/m² and cell temperature 25℃. The model takes into account the series and parallel (shunt) resistance of the module. This paper considers the details of Matlab modeling of the solar module by a developed Simulink model using the basic equations, the first approach was to estimate the parameters: photocurrent Iph, saturation current Is, shunt resistance Rsh, series resistance Rs, ideality factor A at stander test condition (STC) by an iteration process. To implement the iteration process, a numerical approach based on the Newton Raphson method has been implemented and programmed in Matlab. The second mathematical model used in Matlab/Simulink using equations for each parameter to determine the parameters at all operating conditions. The Matlab program gives the information about the behavior of the practical PV module, under different atmospheric conditions. The model accuracy was also analyzed through finding out the compatibility between the practical and the theoretical aspects at different solar radiation intensity 500, 750 and 1000 W/m2 by extracting the error ratios. The results show that there is difference between theoretical (modeled) and experimental, the best validation (less error) between five parameters model and experimental maximum power results at radiation 500, 750, 1000 W/m2 and STC was 5.5%, 19%, 18% and 12.3% in January respectively, due to the decreases in ambient temperature and thus decreases in the temperature of solar module in January led to increase in maximum output power and producing best validation between model and experimental in this month.

يقدم هذا البحث نمذجة الاستجابة الكهربائية لأداء اللوح الشمسي أحادي البلورة باستخدام نموذج الخمس عوامل يستند إلى بيانات ورقة التصنيع للوح الشمسي المقاسة عند الظروف القياسية. يأخذ النموذج في الاعتبار مقاومة التوالي والتوازي للوح الشمسي ويهتم البحث بنمذجة ماتلاب المفصلة للوحدة الشمسية بواسطة نموذج سيمولينك المتطور الذي يستخدم المعادلات الأساسية،الطريقة الأولى لحساب العوامل: التيار الضوئي، تيار إلاشباع، مقاومة التوازي، مقاومة التوالي, عامل الجودة في حالة الظروف القياسية (الإشعاع 1000 واط/متر مربع ودرجة حرارة الخلية ℃25) من خلال عملية التكرار. لتنفيذ عملية التكرار،تم تطبيق نهج رقمي يستند إلى طريقة نيوتن رافسون وبرمجتها فى Matlabالنموذج الرياضي الثاني المستخدم في ماتلاب / سيمولينك من خلال تكوين المعادلات لكل عامل لايجاد العوامل في جميع الظروف التشغيل. برنامج ماتلاب يعطي المعلومات حول السلوك العملي للوح الكهروضوئي في ظل الظروف الجوية المختلفة. كما تم تحليل دقة النموذج من خلال معرفة التوافق بين العملي والنظري عند شدة الإشعاع الشمسي المختلفة 500,750,1000 واط/مترمربع باستخلاص نسب الخطأ. أظهرت النتائج وجود فرق بين نظري (نموذجي) وتجريبي، أفضل تحقيق للطاقة القصوى بين نموذج الخمس العوامل والنتائج التجريبية في الإشعاع 500, 750, 1000 واط/متر مربع وSTC هي 5.5% و19% و18% و12.3 في كانون الثاني على التوالي, بسبب الأنخفاض في درجة حرارة الجو وبالتالي انخفاض حرارة اللوح الشمسي في كانون الثاني مما يؤدي الي زيادة انتاج الطاقة القصوى وانتاج افضل تحقق بهذا الشهر بين المودل والعملي.

Listing 1 - 10 of 14 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (14)


Language

English (13)

Arabic and English (1)


Year
From To Submit

2019 (2)

2018 (2)

2016 (3)

2014 (1)

2013 (2)

More...