research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Performance Assessment of LiBr-H2O Absorption Chiller for Air Conditioning Purposes
تقييم أداء مثلج ماء امتصاصي يعمل بمحلول )ماء + بروميد الليثيوم (لأغراض تكييف الهواء

Authors: Qusay Rasheed Al-Amir --- Hameed Kadhem Hamzah --- Riyadh S.Al-turaihi
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2017 Volume: 15 Issue: 3 Pages: 160-173
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The thermodynamic analysis of a 4TR single stage absorption chiller is executed numerically using Engineering Equation Solver (EES) software. In this chiller, water and lithium bromide mixture is used as a working fluid and supplies by hot water from electrical boiler at any temperature. The investigation is done to assess the effect of varying the exit temperatures of the absorber, evaporator, generator, and condenser on the absorption chiller cycle performance. The cycle simulation is based on the operating temperature ranges and fixed parameters which include as follows: evaporating exit temperature within a range of 2-11 °C, generator exit temperature within a range of 80-89°C, condenser exit temperature range from 30 to 48°C, absorber exit temperature range from 20 to 38°C, three magnitudes of effectiveness of heat exchanger (0.6, 0.65 and 0.7), strong solution flow rate 0.05 kg/s. The results depicted that the performance parameters are affected by the operation temperatures of main components and heat exchanger effectiveness

تم اجراء دراسة عددية ببرنامج EES على مثلج ماء امتصاصي بسعة تتراوح 4 طن تثليجي . هذا المثلج يعمل بمحلول ماء و بروميد الليثيوم كمائع تشغيلي ويجهز بالمائع الحار عن طريق غلاية كهربائية. الهدف من هذا البحث, دراسة تاثير تغير درجات الحرارة الخارجة من الماص و المبخر و المولد والمكثف على أداء مثلج الماء. المحاكاة العددية تمت عند معدلات درجات حرارية مختلفة وكانت كالآتي: درجات الحرارة الخارجة من المبخر بين 2 و11°م, درجات الحرارة الخارجة من المولد بين 80 و89°م , درجات الحرارة الخارجة من المكثف بين 30 و 48°م و درجات الحرارة الخارجة من الماص بين 20 و38°م. كذلك تم دراسة تأثير تغير قيم فعالية المبادل الحراري على أداء المثلج وكانت على التوالي 0,6 و 0,65 و0,7. النتائج المستحصلة بينت ان أداء المثلج يتأثر بتغير درجات الحرارة التشغيلية للمكونات الأساسية للنظام بالإضافة الى تأثره مع تغير قيم فعالية المبادل الحراري.


Article
EFFECT OF WAVY WALL LOCATION ON THE NATURAL CONVECTION IN AN ENCLOSURE CONTAINING A CONCENTRIC HEATED CIRCULAR CYLINDER
تأثير موقعِ الجدار المتموّجِ على الحمل الحراري الطبيعيِ في حيز يَحتوي على أسطوانة دائرية ساخنة مركزية

Loading...
Loading...
Abstract

An investigation has been made to study numerically the effect of wavy wall locations on natural convection flow in a two dimensional enclosure filled with air containing a concentric heated circular cylinder. The external walls of the considered enclosure are maintained at a constant cold temperature (Tc) while the surface of the circular cylinder is kept at a constant hot temperature (Th). The numerical simulation, based on a finite element approach, is performed using program ANSYS version 11. The governing equations with boundary conditions are solved iteratively using the Tri-Diagonal Matrix Algorithm (TDMA). The current work is validated with previous numerical results available in the literature. The study aims to determine the effect of wavy wall location which is represented by varying the inclination angle (∅=0°, 90° and 180°), and undulation numbers (n=1 and 2) on flow field and heat transfer for four selected Rayleigh numbers (Ra=103, 104, 105 and 106). Streamline and isotherm contours are determined. The effect local Nusselt number along the hot surface of the circular cylinder is also examined in this study. The results indicated that the average Nusselt number at the hot surface of the cylinder increases with increasing the Rayleigh numbers and reduces when undulation number increases from one to two.

في هذه الدراسة العددية, تم أجراء دراسة تحقيقيه حول تأثيرِ تغير موقعِ الجدار المتموّج على الحمل الحراري الطبيعيِ في حيز مربع ثنائي الأبعاد مَمتلئ بالهواءِ يَحتوي على أسطوانة دائرية ساخنة مركزية. إنّ الجدرانَ الخارجيةَ للحيز المدروس ثبتت عند درجة حرارة باردة (Tc) بينما سطح الأسطوانة الدائريةِ ثبتت عند درجة حرارية ساخنة (Th). تم إجراء المحاكاة العددية المستندة على نظرية العناصرِ المحدودةِ باستخدام برنامجُ (ANSYS) نسخة 11. إنّ المعادلاتَ الحَاكِمةَ لهذه الدراسة تم َحْلُها باستعمال خوارزميةَ مصفوفةِ ثلاثيةِ القطرَ بشكل تكراري (TDMA). كذالك تم تحقيق من النتائج العددية للعملَ الحاليَ ومقارنتها مع النَتائِجِ العدديةِ المتوفرةِ في الدراسات السابقة. إنّ هدفَ الدراسةِ هو دراسةَ تأثيرَ تغير موقعِ الجدار المتموّج المُمَثَّلُ بتَغيير زاويةِ الميلَ الحيز (∅=0°, 90° و180 °)، وعدد التمواجات السطحية للجدار (=n 1و2) على مجال التدفقِ ونقلِ الحرارةِ لأربعة أعدادِ Rayleigh مختارة (105, 104, 103 =Ra و106). رسمت النتائج العددية على شكل نماذج خطوط تساوي درجة الحرارة وخطوط الانسياب. تم دراسة أيضاً تأثير عددَ Nusselt ألموقعي والمعدل على طول السطحِ الأسطوانة الدائريةِ الساخنة. بينت النَتائِجَ بأنّ عددَ Nusselt المعدل في السطحِ الأسطوانة يَزِيدُ بزيَاْدَة عدد Rayleigh ويُقل عندما يَزِيدُ عددَ التموّجِ مِنْ واحد إلى اثنان .

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2017 (2)