Noise Pollution in Mosul Medical City Center Teaching Hospitals
التلوث الضوضائي في المستشفيات التعليمية لمركز مدينة الطب في الموصل

Authors: Raghad A. Al-Joomard رغد الجومرد --- Asma A. Al-Jawadi اسماء الجوادي --- Humam G. Al-Zubeer همام غانم الزبير
Journal: Annals of the College of Medicine Mosul مجلة طب الموصل ISSN: 00271446 23096217 Year: 2013 Volume: 39 Issue: 1 Pages: 32-37
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

ABSTRACTContext: High levels of noise in hospitals may interfere with patient care services, the doctor-patient relationship and medical education activities.Aim: To measure the noise level and to determine the time-place patterns at Mosul Medical City Center Teaching Hospitals.Materials and methods: Sound levels of different places inside the stated hospitals were recorded, using a Digital Sound Level Meter. A total of 80 readings were taken at different locations of hospitals. The time for each measurement was 5 minutes, repeated for three times in each location, and then the average reading was recorded. Three noise parameters were recorded in every measurement (in dBA): equivalent noise level (Leq), maximum noise level (L max) and minimum noise level (L min). Neither the staff nor the patients in the four institutions were aware of the recordings. Indoor noise levels on weekdays (Saturday through Thursday) were compared to noise levels on weekends (Friday). Outdoor noise levels were measured near each hospital facet, too. Time-patterns of noise pollution were established by recordings at 08:00 a.m., 09:00 a.m., 11:00 a.m., and 02:00 p.m.Results: The mean equivalent sound level was 93.44 ± 6.55 dBA, including hospitals facet. The maximum equivalent sound level was observed in the casualty department (97.80 ± 2.91 dBA) and the minimum equivalent sound level was in Ibn-Sena General Teaching Hospital (89.16 ± 6.83 dBA) (p = 0.001). During morning hours, the mean equivalent noise level (94.35 dBA) was higher than the afternoon level (90.14 dBA) (p=0.037). The mean equivalent noise levels were higher on the weekdays (94.05 dBA) than on the weekend (88.57 dBA) (p = 0.002).Conclusion: The noise pollution in Mosul Medical City center greatly exceeded the WHO guideline level for hospitals. This study highlights the need for noise monitoring and control measures inside hospital areas.Keywords: Noise pollution, hospitals, patterns.

الخلاصةمقدمة: المستوى العالي للضوضاء في المستشفيات قد يؤثر على مستوى الخدمات المقدمة للمريض، وعلاقة المريض بالطبيب وكذلك على نشاطات التعليم الطبي.هدف الدراسة: تهدف الدراسة الحالية إلى قياس مستوى الضوضاء وتحديد النمط المكاني والزماني لها في المستشفيات التعليمية لمركز مدينة الطب في الموصل.¬طريقة الدراسة: تم قياس مستوى الصوت في أماكن مختلفة داخل المستشفيات التعليمية باستخدام جهاز قياس الصوت الرقمي Digital Sound Level Meter)). حيث تم أخذ 80 قراءة بهذا الجهاز في أماكن متعددة من المستشفيات. كل قراءة تستغرق 5 دقائق حيث تمت إعادة القراءة في كل موقع ثلاث مرات ثم أخذ المعدل لها. ثلاثة مقاييس للضوضاء استخدمت في هذه الدراسة: مقياس الصوت المكافئ (Leq)، مقياس الصوت المنخفض (Lmin)، و مقياس الصوت المرتفع (Lmax). وكانت وحدة القياس هي الديسي بل (dBA). النتائج: ظهر أن معدل الصوت المكافئ هو 93,44 ± 6,55 الديسي بل في المستشفيات التعليمية بما فيها واجهة المستشفيات. وأعلى مستوى صوت مكافئ لوحظ في قسم الطوارئ 97,80 ± 2,91 ديسي بل وأوطئ مستوى صوت مكافئ كان في مستشفى ابن سينا التعليمي 89,16 ± 6,83 ديسي بل (p = 0.001). وأظهرت النتائج أن مستوى الصوت المكافئ للفترة الصباحية (94,35 ديسي بل) كان أعلى من المستوى لفترة ما بعد الظهيرة (90,14 ديسي بل). كما لوحظ أن مستوى الصوت المكافئ خلال أيام الدوام الأسبوعي (94,05 ديسي بل) كان أعلى من ذلك المستوى ليوم الجمعة (88,57 ديسي بل) (p = 0.002).ألاستنتاجات: يشكل التلوث الضوضائي في مركز المستشفيات التعليمية لمدينة الموصل الطبية مشكلة حقيقية حيث سجلت مستويات للضوضاء فاقت بكثير المستويات القياسية للصوت لمنظمة الصحة العالمية بالنسبة للمستشفيات. الكلمات الدليلة: التلوث الضوضائي، المستشفيات، الأنماط.


Article
Hypomagnesaemia in critically ill patients
نقص المغنيسيوم في مرضى الحالات الحرجة

Loading...
Loading...
Abstract

ABSTRACTBackground: Hypomagnesaemia is a common electrolyte abnormality in critically ill patients. A lot of controversy exists regarding the optimum method of measuring magnesium and the influence of hypomagnesaemia on the morbidity and mortality of these patients.Objectives: To study the prevalence of hypomagnesaemia (measured in serum and RBCs) in critically ill patients and its impact on morbidity and mortality. Patients and methods: Sixty five (65) critically ill patients were studied. Their total serum and erythrocyte Mg (representing intracellular Mg) were measured within 24 hours of intensive care unit (ICU) admission. The patients were followed throughout their ICU stay and assessed regarding the severity of their illness using acute physiology and chronic health evaluation II (APACHE II) score, duration of stay in the ICU and mortality rate.Results: Serum hypomagnesaemia was present in 84.6% of patients. Only 36.9% of patients were having low erythrocyte Mg. There was a weak positive correlation between serum and erythrocytes Mg levels. No patient with normal serum Mg died, compared with 22.2% mortality rate in patients with low serum Mg (p=0.000). No significant difference in the mortality rate was noticed between patients with normal and low erythrocyte Mg. Neither low serum nor erythrocyte Mg had been associated with more severe illness or prolonged ICU stay.Conclusion: Hypomagnesaemia (measured as total serum Mg) is associated with excess ICU mortality, irrespective of the severity of the underlying illness. Intracellular Mg (measured as erythrocyte Mg) does not correlate with ICU morbidity and mortality, and its routine measurement may not be indicated.

الخلاصةالخلفية: نقص المغنيسيوم أحد اضطرابات الكهاريز الشائعة لدى مرضى الحالات الحرجة. يكتنف كثير من التضارب الطريقة المثلى لقياس المغنيسيوم وتاثير نقص المغنيسيوم على مرضية ووفيات هؤلاء المرضى.الأهداف: دراسة انتشار نقص المغنيسيوم (مقاسا في المصل والكريات الحمراء) في مرضى الحالات الحرجة, وتأثير ذلك على نسبة المرضية والوفيات.المرضى وطرق العمل: درسنا 65 مريضا من المصابين بحالات حرجة. أجرينا قياس نسية المغنيسيوم في مصل الدم والكريات الحمراء خلال 24 ساعة من إدخالهم الى وحدة العناية المركزة. تمت متابعة حالة هؤلاء المرضى طيلة فترة رقودهم, وتم إحتساب حرز اباشي (كمؤشر لشدة المرض) وفترة بقائهم في العناية المركزة ونسبة الوفيات.النتائج: سجل إنخفاض في نسبة المغنيسيوم في مصل الدم لدى 84,6 ٪ من المرضى، بينما بلغت نسبة المرضى الذين لديهم إنخفاض في نسبة المغنيسوم في الكريات الحمراء 36,9 ٪. كانت هناك علاقة موجبة ضعيفة بين نسبة المغنيسيوم في مصل الدم والكريات الحمراء. لم يتوف أي مريض من الذين لديهم نسبة مغنيسيوم طبيعية في الدم, بينما بلغت نسبة الوفيات 22,2٪ لدى المرضى الذين إنخفضت لديهم نسبة المغنيسيوم في مصل الدم عن المدى الطبيعي (ب = 0,000). لم يكن لنقص المغنيسيوم في الكريات الحمراء تأثير ذو قيمة احصائية على نسبة الوفيات. لم يكن لإنخفاض نسبة المغنيسيوم في المصل أو الكريات اي علاقة بشدة المرض أو فترة البقاء في العناية المركزة.الإستنتاج: إنخفاض نسبة المغنيسيوم (مقاسآ في مصل الدم) متعلق بزيادة نسبة الوفيات عند مرضى الحالات الحرجة, وهذا التأثير لا علاقة له بشدة المرض. لم يكن لنسية المغنيسيوم داخل الخلايا (متمثلا بنسبة المغنيسيوم في الكريات الحمراء) أي تأثير على مرضية ووفيات حالات العناية المركزة, وقد لا يكون قياسه ضروريا.