research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Experimental Investigation of Laminar Natural Convection Heat Transfer in a Rectangular Enclosure with and without Inside Partitions

Authors: Ahmed Abdul Ameer Abdul Raheem --- Hussain Y. Mahmood
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 4 Pages: 674-693
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Experimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*10^7 – 1.3*10^8) and aspect ratio of (0.5). 22 different configurations of partition were used in this study these are:a)Undivided enclosure (no – partition).b)(21) Cork partitions of different shapes.Empirical correlations for average Nusselt number are obtained for the different cases tested. The results show that heat transfer is independent on the partition position according to the cold wall and according to the upper or lower walls, while it shows that heat transfer is sensitive to:1.Rayleigh number (Ra), which increase with increasing Ra.2.Aperture height ratio (Ap=hp/H), which is found that when Ap= 5/6 (case 2,3), the reduction in heat transfer is 10.3%, while when Ap=1/2 (case 4,5), the reduction is 17.2% compared with the non partitioned enclosure.3.Aperture position according to the height, which is found that when the aperture at the centre of the partition (case 13), the reduction in heat transfer is 16.7%, while when the aperture displaced to the upper surface (case 14), the reduction is 19% compared with the non partitioned enclosure.4.Partition thickness (t), which is found that when t = 10 mm (case 4,5) the reduction in heat transfer is 17.2%, while when t = 150 mm (case 16) the reduction is 20.5% compared with the non partitioned enclosure.5.Partition inclination (δ), which is found that the rate of heat transfer reduced with increasing as shown:a.For δ= 30° toward the cold wall (case 22), the reduction in heat transfer is 18.2%.b.For δ= 45° toward the cold wall (case 18), the reduction in heat transfer was 21.9%.c.For δ= 60° toward the cold wall (case 20), the reduction in heat transfer is 30.2%.d.For δ= 30° toward the hot wall (case 21), the reduction in heat transfer is 31.3%.e.For δ= 45° toward the hot wall (case 17), the reduction in heat transfer is 40.7%.f.For δ= 60° toward the hot wall (case 19), the reduction in heat transfer is 42.1%

اجريتْ دراسة عملية لانتقال الحرارة بالحمل الطبيعي الطباقي لجريان الهواء في حيز مغلق بوجود حواجز ذات أشكال هندسية مختلفة وبعدم وجود حاجز, يتم وضع الحاجز بين سطحين أحدهما بارد والاخر ساخن بشرط ثبوت درجة الحرارة, بينما الاسطح الباقية معزولة حرارياً. الجانب العملي اشتمل على تصميم وبناء جهاز مختبري لدراسة تأثير رقم رايلي (Ra), نسبة ارتفاع فتحة الحاجز الى ارتفاع الحيز (Hp), سمك الحاجز (t), موقع الفتحة في الحاجز, موقع الحاجز, و ميلان الحاجز. اجريت الدراسة العملية باستخدام الهواء كوسط ناقل للحرارة (مائع العمل) ولمدى عدد رايلي ( 5×7^10 – 1.3×8^10) ولنسبة ارتفاع الحيز الى طوله (النسبة الباعية) تساوي نصف. ولقد تم استخدام (22) حاجزاً بمختلف الاشكال :غرفة مفردة بدون حاجز.حواجز من الفلين وعددها (21). تم استنتاج علاقات تجريبية للحالات المختلفة التي درست, وقد بينت النتائج ان الحرارة المنتقلة لا تعتمد على موقع الحاجز نسبة الى الجدار البارد, بروز الحاجز من الاعلى او من الاسفل, وانما تعتمد على:1)رقم رايلي (Ra) , حيث وجد ان معدل انتقال الحرارة يزداد بزيادة رقم رايلي.2)نسبة ارتفاع فتحة الحاجز الى ارتفاع الحيز(Ap), حيث وجد عندما تكون (Ap=5/6) (حالة 2,3), ان الحاجز يقلل من انتقال الحرارة بنسبة %10.3, بينما عندما (Ap=1/2) (حالة 4,5), الحاجز يقلل من انتقال الحرارة بنسبة 17.2%, مقارنة بانتقال الحرارة في الحيز بعدم وجود حاجز.3)موقع الفتحة نسبة الى الارتفاع, حيث وجد عندما تكون الفتحة في وسط الحاجز (حالة 13), ان الحاجز يقلل من انتقال الحرارة بنسبة 16.7%, بينما عندما تكون الفتحة قرب الجدار العلوي (حالة 14) الحاجز يقلل من انتقال الحرارة بمقدار 19%, مقارنة بانتقال الحرارة في الحيز بعدم وجود حاجز.4)سمك الحاجز (t), حيث وجد عندما يكون سمك الحاجز 10 ملم (حالة 4و5), ان الحاجز يقلل من انتقال الحرارة بمقدار 17.2%, بينما عندما يكون سمك الجدار 150 ملم (حالة 16), الحاجز يقلل من انتقال الحرارة بمقدار 20.5%, مقارنة بانتقال الحرارة في الحيز بعدم وجود حاجز.5)زاوية ميلان الحاجز (δ), حيث وجد ان معدل انتقال الحرارة يقل بزيادة زاوية ميلان الحاجز.•عندما يميل الحاجز بزاوية °30 باتجاه الجدار البارد (حالة 22), الحاجز يقلل من انتقال الحرارة بمقدار 18.2%. •عندما يميل الحاجز بزاوية °45 باتجاه الجدار البارد (حالة 18), الحاجز يقلل من انتقال الحرارة بمقدار 21.9%. •عندما يميل الحاجز بزاوية °60 باتجاه الجدار البارد (حالة 20), الحاجز يقلل من انتقال الحرارة بمقدار 30.2%. •عندما يميل الحاجز بزاوية °30 باتجاه الجدار الحار (حالة 21), الحاجز يقلل من انتقال الحرارة بمقدار 31.3%. •عندما يميل الحاجز بزاوية °45 باتجاه الجدار الحار (حالة 17), الحاجز يقلل من انتقال الحرارة بمقدار 40.7%. •عندما يميل الحاجز بزاوية °60 باتجاه الجدار الحار (حالة 19), الحاجز يقلل من انتقال الحرارة بمقدار 42.1%.


Article
Flow Calculations for a Two-Dimensional Irrigation Nozzle

Authors: Munther A. Mussa --- Hussain H. Ahmad --- Hussain Y. Mahmood
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2005 Volume: 11 Issue: 4 Pages: 759-773
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The most efficient nozzle is generally considered to be that for which the discharge coefficient is nearly unity. Nozzle dimensions influence the discharge coefficient. In sprinkler irrigation systems there are many types of nozzles because any sprinkler irrigation system has special one depend on these system characteristics, so the discharge coefficient relation with nozzle dimensions must be known to the sprinkler irrigation system designer. A computer program for nozzle flow characteristic was built and the relation between the discharge coefficient (Cd) and the nozzle geometrical dimensions to reach to the best nozzle design was studied. The finite difference approach was introduced to carryout all computations with special grid arrangement. The steady state Navier-Stocks equations complemented with (k - ε) turbulence models were solved. These work calculations were for nozzle of convergent part with some angle (3.7° -7.7°) followed by straight part (tip part). Three values were taken for the convergent part length; three for tip part length and the nozzle diameter changed for three values also. The Reynolds number range was 1.95 x 10^5 < Re < 3.9 x 10^5 and Fortran 95 computer program language was used. The results gave good imaging to the relation between nozzle dimensions and the discharge coefficient, where the major result was increasing the tip length is allowing the boundary layer to growth and hence increasing its thickness and so discharge coefficient decreasing. Comparison of the results with ANSYS package shows that the present numerical method was accurate enough and might be used to predict the discharge coefficient for the sprinkler irrigation system nozzle.

النفاث الأحسن كفاءة يعتبر عمومأ الذي له معامل تدفق الأقرب إلى الوحدة الواحدة. معامل التدفق يتأثي بأبعاد النفاث، في منظومات الري بالرش يوجد أنواع متعددة من النفاثات ذلك لان كل منظومة ري بالرش لها نفاث خاص بها يعتمد على مواصفات هذه المنظومة، لذلك علاقة معامل التدفق بأبعاد النفاث يجب أن تكون معروفة لمصمم منظومات الري بالرش. تم بناء برنامج حاسوبي لإيجاد خواص جريان النفاث وتم دراسة العلاقة بين معامل التدفق وأبعاد النفاث الهندسية للوصول إلى احسن تصميم للنفاث. استخدمت طريقة الفروق المحددة لانجاز الحسابات مع شبكة عقدية خاصة، معادلات Navier-Stock للحالة المستقرة بالتكامل مع نموذج(k - ε) للإضطراب تم حلها. الحسابات في هذا العمل تمت لنفاث ذو جزء متقارب بزاوية معين (3.7° -7.7°) يتبعه جزء ثابت المساحة العرضية، تم أخذ ثلاثة قيم لطول الجزء المتقارب وثلاثة لطول الجزء الثابت و ثلاثة لقطر النفاث أيضاً. مدى قيم رقم رينولد كان 1.95 x 10^5 < Re < 3.9 x 10^5 و تم استخدام لغة الحاسبة فورتران.95 النتائج تعطي تصور جيد للعلاقة بين أبعاد النفاث و معامل التدفق حيث النتيجة الرئيسية كانت أن زيادة طول الجزء الثابت المساحة تسمح للطبقة المتاخمة أن تنمو وبالتالي زيادة سمكها وهذا يؤدي إلى نقصان معامل التدفق. مقارنة النتائج مع تنائب برنامج ANSYS أظهرت أن الطريقة المستخدمة ذات دقة كافية وممكن استخد امها لإيجاد معامل التدفق لنفاثات منظومات الري بالرش.


Article
Experimental and Numerical Attenuation of Vibration for Delta Wing Using PI Controller

Authors: Ahmed A. Ali --- Hussain Y. Mahmood --- Mahmood Wael Saeed
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 4 Pages: 823-831
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Active vibration controlling loop with proportional - Integral (PI) controller was tested numerically and experimentally for delta wing with three different manufacturing materials; aluminum, [0/90] composite and aluminum foam, both P and PI loop were tested separately. Numerical work was performed in ANSYS v.15 where controller with piezoelectric transducers was totally integrated in program macro. Experimental wings where fabricated to be tested under simulated excitation. Labview 2015 program with high speed Data acquisition were used besides actuators to perform controlling circuit experimentally. Good suppression in wing oscillation was performed where 72% of wing's time of vibration was eliminated for aluminum foam wing. Noticeable agreement was achieved between experimental and numerical responses.

استخدام دائرة تخميد الاهتزاز الفعالة باستخدام المنظم التناسبي – التكاملي عمليا وعدديا لتخميد اهتزاز جناح من نوع دلتا ولثلاث انواع مختلفة من مواد التصنيع وهي الالمنيوم,(0/90) مواد مركبة و رغوة الالمنيوم. جرى اختبار كل من المنظم التناسبي و المنظم التناسبي-التكاملي بصورة منفصلة. تم اجراء الجانب العددي باستخدام برنامج انسز النسخة 15 حيث ان دائرة المنظم مع المواد الذكية كانت قد اٌدخلت بملف برمجة (ماكرو). الاجنحة العملية جرى تصنيعها ليتم اختبارها تحت الاثارة الممثلة سابقا في برنامج الأنسز. تم استخدام برنامج لاب فيو النسخة 2015 مع محول اشارة عالي السرعة الى جانب مولدات الاشارة لإكمال عمل منظومة السيطرة عمليا. تم الحصول على تخميد جيد لاهتزاز الجناح حيث تم تقليل 72% من زمن اهتزاز الجناح لجناح مصنوع من رغوة الالمنيوم. تم ملاحظة توافق جيد بين الاستجابات المقاسة عمليا مع تلك المقاسة عدديا.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (3)


Year
From To Submit

2017 (1)

2011 (1)

2005 (1)