research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Micro determination of Cadmium (II) and Mercury(II) with New Reagent 5-[(4- hydroxyl phenyl)azo ] -4,6- di hydroxyl -2- mercapto pyrimidine as a chelating Reagent by spectrophotometric methods.

Authors: Hussain.J.Mohammed حسين جاسم محمد --- Maysaa A. Majeed --- Shemaa Hamza
Journal: Iraqi National Journal Of Chemistry المجلة العراقية الوطنية لعلوم الكيمياء ISSN: 22236686 Year: 2010 Issue: 40 Pages: 650-663
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Abstract A simple, accurate and sensitive spectrophotometric method for the determination of cadmium (II) and mercury (II) is described. The method is based on the chelation of Cd (II) and Hg (II) ions with 5-[(4-hydroxy phenyl)azo]-4,6 dihydroxy-2- mercapto pyrimidine (HADMP) to form an intense colour soluble products, that are stable and have a maximum absorption at 573.5 nm and at 585 nm. The molar extinction coefficient (ε) 1.5×104 and 2.4×104 L.mole-1.Cm-1 for Cd (II) and Hg (II) respectively .The stability constant, relative error and standard deviations for Cd (II) and Hg (II) were, 2.02×108, 1.05×108 L.mole-1 and (2%, 1.176%), (2%, 2%) respectively. The new reagent and the two metal complexes have been prepared in aqueous solutions and were characterized by electronic spectrum, F.T.IR and also molar conductivity. Under optimum conditions the described methods were applied satisfactorily to biological sample.

الخلاصةتم وصف وتطوير طريقة طيفية بسيطة ودقيقة وحساسة في تقدير الكادميوم (II) والزئبق (II). أعتمدت الطريقة على اساس عملية التعقيد لايون الكادميوم (II) والزئبق (II) مع الكاشف الجديد 5-[(4-هيدروكسي فنيل أزو)]-4,6- ثنائي هيدروكسي -2-مركبتو بيريميدين (HADMP) وتكوين محاليل ملونة ذائبة ثابتة تمتلك أعلى قمة امتصاص عند طول موجي 573.5 نانوميتر و585 نانوميتر ولها معاملات أمتصاص مولاري مقداره 1.5×410 و 2.4×410 لتر .مول-1.سم-1 للكادميوم (II) والزئبق ((II على التتالي. كانت ثوابت الاستقرار ومقدار الخطأ النسبي والانحراف القياسي النسبي للكادميوم (II) والخارصين (II) 2.02×810 و 1.05×810 لتر.مول-1 ,(2%) (2%) و(1.176%),(2%) على التوالي. تم تحضير الكاشف ومعقداته من محاليل مائية وقد تم تشخيصها بوساطة أ طياف الاشعة مافوق البنفسجية –المرئية , ومطيافية ماتحت الحمراء وكذلك التوصلية المولارية. وباستخدام الظروف الفضلى تم تطبيق الطرق على نماذج حيوية (شعرالانسان) .


Article
Synthesis ,spectroscopic study of Antipyryl azo 2-Naphthol and use it as new reagent for determination of Co(II) and Cu(II)
تخليق ودراسة طيفية للمركب Antipyryl azo 2-Naphtholواستخدامه ككاشف جديد لتحديد ايونات Cu(II)و Co(II)

Authors: Fatema. Abbas فاطمة عباس خزعل --- Azhar.Y. Muhi أزهار ياسين محي --- Hussain.J. Mohammed حسين جاسم محمد
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2013 Volume: 10 Issue: 3عدد خاص بموتمر الكيمياء Pages: 977-985
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A simple ,accurate and sensitive spectrophotometric method has been developed the determination of Cobalt(II) and Cupper (II) .The method is based on the chelation of Co(II) and Cu(II) ions with 4-(4´-pyrazolon azo) -2-Naphthol(APAN) in aqueous medium . The complexes have a maximum absorption at (513) and (506) nm and Ԑ max 0.531×10 4 and 0.12×10 5 L.mol -1.cm -1 for Co(II) and Cu(II) respectively .The reagent and two complexes have been prepared in ethanolic solution.The stoichiometry of both complexes were found to be 1:2 (metal :legend) .The effects of various cations and anions on Co(II) and Cu(II) determination have been investigated .The stability constants and standard deviations for Co(II) and Cu(II) 0.291 x107 ,0.909X108 L.mol -1 ,(0.291) and (0.332) respectively .The optimum condition for full color development for described methods were applied satisfactorily to synthetic samples.

تم تطوير طريقة طيفية حساسة وسريعة ودقيقة في تقدير الكوبلت (II) والنحاس (II) . اعتمدت الطريقة على عملية التعقيد بين الايونات المذكورة والكاشف 4(4- بايروزولون ازو|)-2-نفثول في الوسط المائي. كانت قيمة الامتصاصية العظمى وثابت الامتصاصية المولارية للمعقدات المتكونة 513 و 506 , 0,531x104 و 0,12x105 لتر .مول-1 .سم-1 للكوبلت والنحاس على التوالي . تم تحضير الكاشف ومعقديه من المحاليل الايثانولية المائية. اثبتت الدراسة الستكيومترية ان نسبة الفلز الى الكاشف هي (2:1) . درست التداخلات الايونية من خلال استعمال الايونات السالبة والموجبة وكانت قيم ثوابت الاستقرار والانحراف القياسي 0,291x107 و 0,909x108 لتر زمول-1 , (0,291) و (0,332) على التوالي. تم تطبيق الطريقة وبنجاح على نماذج مختبرية محضرة .

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2013 (1)

2010 (1)