research centers


Search results: Found 9

Listing 1 - 9 of 9
Sort by

Article
AQUIFERS DELINEATION USING VERTICAL ELECTRICAL SOUNDING IN SOUTH AND SOUTHWEST OF SAMAWA CITY, SOUTHERN IRAQ
تحديد الخزانات الجوفية باستعمال الجس الكهربائي العمودي في جنوب وجنوب غرب مدينة السماوه، جنوب العراق

Authors: Jassim M. Thabit جاسم محمد ثابت --- Ahmed S. Al-Zubedi احمد سرداح الزبيدي
Journal: Iraqi Bulletin of Geology and Mining مجلة الجيولوجيا والتعدين العراقية ISSN: 18114539 Year: 2015 Volume: 11 Issue: 1 Pages: 133-141
Publisher: Ministry of Industry and Minerals وزارة الصناعة والمعادن

Loading...
Loading...
Abstract

This study includes application of (VES) Vertical Electrical Sounding for delineation of aquifers in the area located south and southwest of Samawa City, southern Iraq. The VES was carried out by using Schlumberger array in the 16 sounding points distributed along three profiles trending NW – SE, except one point that is not located within any profile. The field curves of apparent resistivity are interpreted by the application of forward calculation and inverse modeling. The results of the inverse modeling are used to construct three geo-electrical sections along electrical profiles, and then converted to geological sections by including the lithological well sections and all available geological and hydro-geological information. The results indicate the presence of three aquifers. The first is the Euphrates aquifer which is located at depths ranging between 1 and 7 m. This aquifer overlaps with the Ghar aquifer in the southeast area, and thus forming one hydro-geological unit. The thickness of this aquifer varies from 8 to 30 m. The second is the Ghar aquifer which appears at depths (1 – 3) m. The thickness of this aquifer ranges between 12 and 40 m. The third is Dammam aquifer, which occurs below the Euphrates aquifer in the north and southeast of the Al-Emaed spring. It also occurs below the Euphrates and the Ghar aquifers in the southeast end of the studied area; its depths ranges between 13 and 43 m, in most locations, but to the south and southwest of Al-Emaed spring, near the ground surface. Its thickness ranges between 100 and 120 m, and it splits into two parts in the area located north and southeast of Al-Emaed spring. The lower part is characterized by increased fractures in comparison with the upper part. The presence of hydraulic connection between these aquifers is observed and this agrees with previous studies.

تضمنت هذه الدراسة تطبيق الجس الكهربائي العمودي (VES) لتحديد الخزانات الجوفية في المنطقة الواقعة جنوب وجنوب غرب مدينة السماوه، جنوب العراق. أنجز الجس الكهربائي العمودي باستعمال ترتيب شلمبرجر للأقطاب في 16 نقطه جس توزعت على ثلاثة مسارات ماعدا نقطه جس واحدة لم تقع ضمن أي مسار، وقد فسرت المنحنيات الحقلية للمقاومة النوعية الكهربائية بتطبيق كل من طريقة الحساب الأمامي (Forward Calculation) وطريقة الموديل المعكوس (Inverse Modeling). وقد تم الاعتماد على نتائج طريقة الموديل المعكوس لرسم ثلاث مقاطع جيوكهربائيه على طول مسارات المسح، حولت هذه المقاطع الى مقاطع جيولوجية بالاعتماد على المقاطع الصخرية للآبار المحفورة والتي تمر بها تلك المسارات بالإضافة إلى كل المعلومات الجيولوجية والهيدروجيولوجية المتوفرة. بينت نتائج الجس الكهربائي العمودي من خلال المقاطع الجيولوجية وجود ثلاثة خزانات للمياه الجوفية في المنطقة، الخزان الأول هو خزان الفرات الذي يقع على عمق يتراوح (1 – 7) م، يتداخل هذا الجزء من الخزان مع خزان تكوين الغار ليشكلان وحده هيدروجيولوجية واحده في المنطقة الجنوبية الشرقية من منطقه الدراسة بسمك يتراوح بين (30 – 8) م. الخزان الثاني هو خزان تكوين الغار ويقع على عمق يتراوح (1 – 3) م وله سمك يتراوح بين (12 – 40) م. أما الخزان الثالث فهو خزان تكوين الدمام الذي يقع تحت خزان تكوين الفرات شمال وجنوب شرق عين العميد وتحت خزان تكوين الغار في نهاية المنطقة الجنوبية الشرقية لمنطقة الدراسة ويقع هذا الجزء من الخزان على عمق يتراوح بين (13 – 43) م تقريبا في معظم المناطق ماعدا المنطقة الواقعة جنوب وجنوب غرب عين العميد، حيث يكون قريباً من سطح الأرض، أما سمك الخزان فيتراوح بين (100 – 120) م، ينقسم هذا الجزء من الخزان الى جزئيين في المنطقة الواقعة شمال وشرق عين العميد، الجزء الأسفل يتميز بكثرة وجود الكسور مقارنه بالجزء الأعلى. كما لوحظ وجود اتصال هيدروليكي بين هذه الخزانات وهذا ما يتفق مع الدراسات السابقة.


Article
Delineation of Quaternary Aquifers by Using Long 2D Imaging in Southern Al-Shihaby Area (Wasit Governorate), Eastern Iraq
تحديد خزانات العصر الرباعي باستخدام التصوير ثنائي البعد الطويل في جنوب منطقة الشهابي (محافظة واسط ) شرق العراق

Authors: Jassim M. Thabit جاسم محمد ثابت --- Kassim A.AL-Tamimi قاسم عبد التميمي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 1C Pages: 785-797
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An electrical survey was carried out by using 2D imaging technique at (15) station. The study area is located southern Al-Shihaby area, south-east of Wasit governorate, Eastern Iraq. The numbers of the employed electrodes were (120) and the (a) spacing equal to (10m), and the total length of survey line is (1200m). The inverse models of 2D imaging showed one Quaternary aquifer located in the Quaternary deposits which comprises in alluvial fan and wind deposits of (Pleistocene – Holocene) ages. Layers of aquifer consist of gravel and sand with little silt. Low resistivity values reflected the presence of clay layers, and increasing salinity of water gradually with the depth. The aquifer occurs at minimum depth equal to (12m) approximately in the inverse model of 2DSh10 station and maximum depth equals to (153m) approximately in 2DSh2 station. In addition, the minimum thickness of aquifer was (7m) approximately as appeared in 2DSh15 station and the thickness increased to (91m) approximately in 2DSh4 station. The results indicated that the type of aquifer is unconfined.

نفذ المسح الكهربائي باستخدام تقنية التصوير ثنائي البعد في (15) محطة. وتقع منطقة الدراسة جنوب منطقة الشهابي، جنوب شرق محافظة واسط، شرق العراق. وكانت عدد الأقطاب المستعملة (120). أما المسافة القطبية (a) فتساوي (10م). لذلك كان الطول الكلي لمسار المسح (1200م). أظهرت الموديلات المعكوسة وجود خزان جوفي يعود إلى رواسب العصر الرباعي والتي تتكون من ترسبات المراوح الغرينية والريحية، وهي ذات أعمار (البليستوسين- هولوسين). وظهر الخزان الجوفي على عمق (12م) تقريبا" في محطة ثنائي البعدين ( (2DSh10ويزداد إلى عمق (153م) تقريبا" في محطة ((2DSh2. أما سمك الخزان فكان يتراوح بين (7م) تقريبا" في محطة ( (2DSh15ويزداد إلى (91م) تقريبا" في محطة (2DSh4). بينت النتائج أن الخزان الجوفي من النوع غير المحصور.


Article
Evaluation of Three Important Electrode Arrays in Defining the Vertical and Horizontal Structures in 2D Imaging Surveys
تقييم ثلاثة ترتيبات كهربائية مهمة في تحديد التراكيب العمودية والافقية في المسوحات ثنائية البعد

Authors: Jassim M. Thabit جاسم محمد ثابت --- Ahmed S. Al-Zubedi احمد سرداح الزبيدي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 2B Pages: 1465-1470
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Three important electrode arrays in 2D imaging surveys were tested in this study through synthetic model to determine which array is the most successful in defining the vertical and horizontal geological structures. These arrays are Wenner-Schlumberger, Wenner and Dipole - dipole. The numerical modeling was created through vertical fracture zone and three separate cavities surrounded by horizontal layers. The results showed that the Wenner-Schlumberger is the most suitable electrode array when both vertical and horizontal structures are present in the subsurface. It is the best in imaging the vertical and horizontal contacts and represented these structures more accurately than the Wenner and Dipole-dipole arrays.

اختبرت في هذه الدراسة ثلاثة ترتيبات كهربائية مهمة تستعمل في المسوحات ثنائية البعد من خلال موديل صناعي لتحديد الترتيب الاكثر نجاحا في تصوير التراكيب الجيولوجية العمودية والافقية. هذه الترتيبات هي فنر- شلمبرجر , فنر و ثنائي القطب. صمم الموديل العددي من خلال طبقات افقية تحتوي على نطاق تكسر عمودي وثلاثة فجوات متفرقة. اظهرت النتائج ان ترتيب فنر- شلمبرجر هو الاكثر ملائمتا" في حالة وجود مثل هذه التراكيب الجيولوجية معا , حيث صور الحدود العمودية والافقية بينها وبين الطبقات بدقة اكبر من باقي الترتيبات.


Article
Distinction of Two Zero-Spaced Iron Pipes in GPR Radargram for Engineering ProblemsJassim M. Thabit
تمييز مسافة التباعد بين ألأنابيب الحديدية في التسجيلات الجيورادارية للأغراض الهندسية

Authors: Jassim M. Thabit جاسم محمد ثابت --- Hawkar B.Bakir هاوكار بابير بكر
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 3A Pages: 1775-1782
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The researchers have tried to focus on how to determine the number of pipes that are present in one obtained hyperbola in radargram profile. Ground Penetration Radar (GPR) survey was performed to distinguish between two zero-spaced iron pipes in radargram. The field work was carried out by constructing artificial rectangular models with dimensions of length, width, and depth equal to 10.0, 1.0, 0.65 meter respectively that filled with dry clastic mixture deposit, three twin sets of air filled iron pipes of 15.24 cm (6 inch) diameter were buried horizontally and vertically inside the mixture at different distances together. Visual and Numerical interpretation were chosen to get the best results. In the visual interpretation, the amplitude variations show that the height of the positive peaks increases with the increase of the space distance between the buried pipes. Numerical interpretation appeared that the decrease in the width of the bands means an increase of the space between the pipes. The second part of the numerical analysis comprises measuring the amplitude value variation, among the signal forms; relying on the value of amplitude in each hyperbola the distinction process becomes quite easy. Depending on the variations in amplitude, the identification and discrimination of two closely spaced underground pipes will be feasible. The big values refer to highly spaced pipes while the low values denote the slightly spaced pipes. It is worth mentioning that the lowest value indicates the amplitude of only one buried iron pipe.

حاول الباحثان التركيز على كيفية تحديد عدد الأنابيب التي تظهر في القطع الزائد للمقطع الجانبي الجيوراداري. تم إجراء المسح الجيوراداري للتمييز بين اثنين من ألأنابيب الحديدية المتباعدة بمسافات مختلفة. لذلك تم تنفيذ العمل االحقلي من خلال بناء نماذج مستطيلة ذات أبعاد (10.0 × 1.0 × 0.65) متراً مكعباً تحتوي على مزيج لرواسب فتاتية،وتم دفن ثلاث مجموعات ثنائية من أنابيب الحديد بقطر 15.24 سنتمتر (6) أنجاً أفقيا وعموديا داخل المزيج وعلى مسافات مختلفة. وقد تم اختيار التفسير البصري والعددي للحصول على أفضل النتائج. في التفسير البصري، اختلافات السعة يشير الى أن ارتفاع القمم الموجبة في السعة يزداد مع زيادة المسافة بين الأنابيب المدفونة. التفسير العددي أظهر أن النقصان في العرض الى القطع الزائد(Hyperbola) يعني زيادة المسافة بين الأنابيب. الجزء الثاني من التحليل العددي يتألف من قياس التباين في قيمة السعة بين أشكال ألأشارة ،والاعتماد على قيمة السعة في كل قطع زائد تصبح عملية التمييز سهلة جدا. اعتمادا على الاختلافات في السعة، يكون من الممكن تحديد وتمييز اثنين من ألأنابيب المدفونة تحت سطح الأرض و متباعدة بمسافة معينة. القيم الكبيرة تشير إلى مسافة تباعد كبيرة بين ألأنابيب ، في حين أن القيم المنخفضة تشير الى مسافة قليلة بين ألأنابيب. ومن الجدير بالذكر أن القيم ألأقل تشير إلى أن السعة هي لأنبوب حديدي واحد.


Article
In Situ Measuring of Relative Dielectric Permittivity to Calculate Electromagnetic Wave Velocity
القياس الموقعى لثابت العزل الكهربائى لحساب سرعة الموجة الكهرومغناطيسية

Authors: Hawkar B.Bakir هاوكار بابير بكر --- Jassim M. Thabit جاسم محمد ثابت
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 3C Pages: 2252-2257
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The relative dielectric permittivity (dielectric constant) values for various materials are measured on site. The calculated values that are derived from measuring the ratio of the electrical capacitance of a cell when the sample of the material is placed. Parallel plate technique that consists of two parallel circular metallic plates is used. The instrument made up of aluminum which acts as electrodes and stuffed inside the PVC cylinder. Then the thin sheet of material (models) sandwiched between the two plates. Calculation of dielectric constant (εr) through this new technique gives a new velocity value of electromagnetic wave that propagates underground. These measured velocity values will utilize in Ground Penetration Radar (GPR) data acquisition and interpretation in order to increase the resolution of the obtained radargrams.

لقد تم قياس قيم سماحية العازل النسبية (ثابت العزل الكهربائي) لمختلف المواد في الموقع . القيم الجديدة تعتمد على قياس نسبة السعة الكهربائية الى الخلية للمادة المراد قياس ثابت العزل الكهربائي لها. تم في هذا العمل ألأعتماد على تقنية اللوحة المتوازية والتي تتألف من لوحتين معدنيتين دائريتين متوازيتين .أما الجهاز فيتكون من الألومنيوم الذي يعمل بمثابة أقطاب محشوة داخل اسطوانة بلاستيكية، ويتم وضع طبقة رقيقة من المادة المراد قياس ثابت العزل الكهربائي لها بين ألأسطوانتين.أن حساب ثابت العزل الكهربائي من خلال التقنية الجديدة يعطي قيمة جديدة لسرعة الموجات الكهرومغناطيسية للمواد تحت سطح الأرض. هذه القيم للسرعة سوف تستخدم في القياس والتفسير للبيانات الجيورادارية وذلك لزيادة القدرة التحليلية .


Article
Delineation of Subsurface Fractures Density Within and Out of Abu-Jir Fault Zone Using 2D Imaging Resistivity Technique, A case Study from Southwest of Karbala City, Central Iraq
تحديد كثافة الكسور تحت السطحية ضمن وخارج نطاق فالق ابو جير باستخدام تقنية المقاومة النوعية ثنائية البعد, دراسة في جنوب غرب مدينة كربلاء , وسط العراق

Authors: Ahmed S. Al-Zubedi احمد سرداح الزبيدي --- Jassim M. Thabit جاسم محمد ثابت --- Mohammed M. AL-Hameedawi محمد محسن الحميداوي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 1B Pages: 466-473
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The 2D imaging survey was carried out using Wenner-Schlumberger array through (11) 2D survey lines distributed within and out of Abu-Jir fault zone, Southwest of Karbala City, central Iraq. The aim is to delineate subsurface fractures density. The total length of each 2D survey line is (600m.) with the unit electrode spacing (a) equals to (10m.).The results showed two types of fractures zones. The first type is formed by dissolution process of carbonate rocks, while the second fractures zone is formed from tectonic movements, and it includes two types of fractures system, oblique and vertical fractures. This study includes comparison between subsurface fracture density within and out of Abu- Jir fault zone. This comparison showed that the fracture zones are characterized by increasing of resistivity values within Abu- Jir fault zone to reach (106.1 Ω.m), while it decreases out of this zone to reach (30.9 Ω.m). This is caused by increasing groundwater salinity out of this zone. In addition, the fractures density within Abu- Jir fault zone is more than outer ones, despite they have high resistivity values. In general, they increase with the depth, in (NE) direction within and out of this zone. The results indicated that the best area of groundwater investment is located within Abu- Jir fault zone.

نفذ المسح الكهربائي ثنائي البعد باستخدام ترتيب فنر- شلمبرجر للاقطاب من خلال (11) خط مسح ثنائي البعد, وزعت ضمن و خارج نطاق فالق ابو جير, جنوب غرب مدينة كربلاء المقدسة, وسط العراق, للتحديد كثافه التكسرات التحت سطحيه. بلغ طول مسافه النشر لكل خط مسح ثنائي البعد (600م) , اما المسافة الفاصلة بين الاقطاب فقد كانت (10م). اظهرت النتائج, ان هناك نوعان من انطقة التكسرات, النوع الاول تكون بسبب عملية الاذابة للصخور الكاربونية, اما النوع الثاني فتكون نتيجة الحركات التكتونية والذي يتضمن نوعين من انظمة التكسرات, التكسرات المائلة و التكسرات العمودية. في هذه الدراسة تم اجراء مقارنة بين كثافة التكسرات ضمن وخارج نطاق الفالق, هذه المقارنة اظهرت ان انطقة التكسرات تتميز بارتفاع قيم المقاومة النوعية داخل نطاق فالق ابو جير لتصل الى(106,1 اوم.متر), بينما تقل خارجه لتصل الى ( 30,9 اوم.متر). وهذا نأتج عن زياده ملوحة المياة الجوفية خارج هذا النطاق. بالاضافة الى ذلك , فان كثافة الكسور داخل نطاق فالق ابوجير هي اعلى من كثافتها خارجه, وبشكل عام تزداد كثافة هذه الكسور مع العمق في الاتجاه (NE) في كلا المنطقتين . النتائج اشارت بان افضل منطقة لاستثمار المياة الجوفية تقع ضمن نطاق فالق ابو جير.


Article
3D resistivity imaging survey to delineate Um El-Githoaa cavity in Hit area, Western Iraq
المسح التصويري الثلاثي ألأبعاد لتحديد فجوه أم الجذوع في منطقة هيت ،غرب العراق

Authors: Jassim M. Thabit جاسم محمد ثابت --- Ali M. Abd علي مشعل عبد --- Firas H. AL-Menshed فراس حميد المنشد
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2015 Volume: 20 Issue: 2 Pages: 135-141
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The 3D resistivity imaging survey was carried out over Um El-Githoaa cavity in Hit area, western Iraq. Resistivity data were collected along four parallel traverses using Dipole-dipole array with electrode spacing of (2m) and (n) factor equal to 6. Inversion 3D models of standard least-squares method and robust constrain method for Um El-Githoaa cavity showed horizontal slices of the 3D resistivity distribution with depth. The first three slices, which represented the resistivity changes from ground surface to depth approximately equal to (3m), showed relatively higher resistivity reflecting the dry sediments of gypsum rocks, and some of these rocks visible on ground surface .The slices after (3m) depth showed the effect of the subsurface cavity by noticeable increasing in resistivity contrast (more than 800 ohm.m)with surround sediment, and the dimensions of the cavity equal approximately to the actual dimensions of this cavity. The comparison between the two methods of inversion appeared that the invers model produced by the robust constrain method has sharper and straighter boundaries, and the dimensions of the Um El-Githoaa cavity appeared closer to the actual dimension of this cavity (maximum diameter equal approximately to 19.3m, while the minimum equal to 15.8m and perpendicular to the first diameter). Therefore, the 3D resistivity imaging survey was delineated Um El-Githoaa cavity at depths ranges from (3 to 6 m). It is concluded that, the dense measurements along 2D lines in small area can be increasing the 3D imaging resolution.

تم أجراء المسح الثلاثي ألأبعاد فوق فجوه أم الجذوع الواقعة في منطقة هيت غرب العراق.وكان الهدف هو تقييم هذا النوع من المسح في تحديد الفجوات التحت سطحية.وتم أخذ القياسات للمقاومة النوعية بأمتداد أربعة مسارات متوازية، وبأستعمال ترتيب ثنائي القطبين (Dipole-dipole array) .وقبل تنفيذ العمل الحقلي تم تحديد المسافة القطبية (a) والعامل (n) وكانت تساوي 2متر و6 على التوالي . وتم رسم الموديلين المعكوسين ثلاثيي ألأبعاد لفجوة أم الجذوع بطريقة(Standard least-squares) وطريقة (Robust constrain). أظهرت الشرائح ألأفقية لهما تغير قيم المقاومة مع العمق ،وأن الشرائح الثلاثة ألأولى تمثل تغير قيم المقاومة الى عمق3 متر تقريبا، وتعكس أرتفاعا نسبيا في المقاومة والتي تعود الى الرواسب الجافة للحجر الجبسي والذي تظهر أجزاء منه على سطح ألأرض.الشرائح بعد عمق 3 متر تظهر تأثير فجوة أم الجذوع ،وذلك بزيادة فرق المقاومة لها(أعلى من 800 أوم.متر)مع الرواسب المحيطة . وأبعاد الفجوة المحدد من هذه الشرائح مساويا تقريبا الى ألأبعاد الحقيقية لها والمحدده من المشاهد الحقلية.عند المقارنة بين طريقتي التفسير أعلاه تبين أن الموديل المعكوس لطريقة (Robust constrain) قد أظهر حدود حادة واكثر أستقامة االى الفجوة ،وألأبعاد الى الفجوة أقرب الى ألأبعاد الحقيقية.لذلك فأن المسح الثلاثي ألأبعاد قد حدد فحوة أم الجذوع على عمق يتراوح بين (3-6) متر.وتم ألأستنتاج أن القياسات الكثيفة بأمتدادات المسارات الثنائية البعدين (2D Imaging) في المسوحات الصغيرة يمكن أن تزيد القدرة التحليلية للمسح الثلاثي ألأبعاد.


Article
ESTIMATION OF HYDRAULIC PARAMETERS AND POROSITY FROM GEOELECTRICAL PROPERTIES FOR FRACTURED ROCK AQUIFER IN MIDDLE DAMMAM FORMATION AT BAHR AL-NAJAF BASIN, IRAQ
تخمين المعاملات الهيدروليكية والمسامية من الصفات الجيوكهربائية للخزان الجوفي الحجري المتكسر لتكوين الدمّام في حوض بحر النجف, وسط العراق

Authors: Jassim M. Thabit جاسم محمد ثابت --- Ameen I. Al-Yasi أمين إبراهيم الياسي --- Ala'a N. Al-Shemmari علاء ناصر الشمّري
Journal: Iraqi Bulletin of Geology and Mining مجلة الجيولوجيا والتعدين العراقية ISSN: 18114539 Year: 2014 Volume: 10 Issue: 2 Pages: 41-57
Publisher: Ministry of Industry and Minerals وزارة الصناعة والمعادن

Loading...
Loading...
Abstract

This study tries to examine the correlation between the hydraulic and geoelectrical parameters in an appropriate way, to construct empirical relationship at sites in Bahr Al-Najaf basin in the middle part of Iraq. It is a first attempt of estimating mathematically the effective porosity, hydraulic conductivity, and transmissivity of a confined and anisotropic aquifer of Middle Dammam formation. This aquifer is distinguished with the presence of fractures and paleo karst features of Carbonate rocks. Sixteen of (VES) Schlumberger array using a maximum current electrode separation of (1000) m are conducted near existed wells and boreholes (with pumping test data). The field (VES) data is interpreted, and values of geoelectrical parameters as layer resistivity and thickness, in addition to Dar Zarrouk parameters are determined. Correlating Dar Zarrouk parameters with hydraulic conductivity and transmissivity (derived from pumping test analyses) at nine positions nearby selected boreholes is made. Then representing the results as several graphical relationships of nonlinear curves with polynomial equations of second order and show very good Reliability (R2). Directly proportional relations between longitudinal conductance with both; the hydraulic conductivity of R2 = 0.893 and the transmissivity of R2 = 0.868 are more conformable for such aquifer of average resistivity (70) Ωm. Mathematically estimated values of hydraulic conductivity, transmissivity and those estimated by pumping test analyses are compared by means of histogram figures. The small error ratios (RMS %) as (5.53) and (6.32) between the average values respectively, verify the validity of this methodology to be applied in other sites of similar characteristics. Average effective porosity (secondary type) and water saturation of Middle Dammam aquifer are geophysically computed by Archie's equation as (22%) and (0.9) respectively. These results are close to the typical porosity of saturated carbonate rocks as (27%), and agree with the prevail knowledge that the studied area is a discharge zone for Al-Shbecha hydrogeological basin.

هذه الدراسة تمثل محاولة لاختيار المضاهاة بين المعاملات الهايدروليكية والجيوكهربائية بطريقةٍ مناسبةٍ من أجل استنباط علاقات تجريبية بينهما في مناطق من حوض بحر النجف في الجزء الأوسط من العراق. إنها المحاولة الأولى لحساب قيم المسامية الفعالة، التوصيلية الهايدروليكية والناقلية رياضياً للخزّان الجوفي المحصور والغير متجانس.إن هذا الخزّان يتميّز باحتوائه على الكسور والتكهفات القديمة العائدة لتكوين الدمّام الكاربوناتي. تم إنجاز ستة عشر مسحاً كهربائياً عمودياً (VES) بترتيب شلمبرجر وبأقصى انفتاح مقداره (1000) م بين أقطاب التيار بالقرب من الآبار الموجودة وآبار الدلالة ذات معلومات الضخ الاختباري. تم تفسير المعلومات الحقلية العائدة للمسحح الكهربائي (VES)، وأن قيم المعاملات الجيوكهربائية كالمقاومية النوعية الحقيقية والسمك الطباقي، مضافاً لمعاملات دار زاروك (Dar Zarrouk) قد حُددت. إن المضاهاة لقيم معاملات دار زاروك مع قيم التوصيل الهايدروليكي والناقليّة (المشتقة من تحاليل الضخ الاختباري) عند تسعة مواقع بالقرب من آبار الدلالة المختارة أجريت. لقد مُثلت النتائج بشكل علاقات بيانية ذات منحنيات غير خطية ومعادلات متعددة الحدود للدرجة الثانية والتي تمتلك قيم ثقة (R2) جيدة جداً. العلاقات الطرديةُ المباشرة بين التوصيل الطولي مع كل من التوصيل الهايدروليكي ذي R2 = 0.893 والناقليّة ذي R2 = 0.868 تُعتبر أكثر ملائمة للاعتماد لمثل هذا الخزان والذي له مقاوميه نوعية تبلغ (70) أوم.متر. إن قيم التوصيل الهايدروليكي والناقلية المحسوبة رياضياً تمت مقارنتها مع تلك المحسوبة بواسطة الضخ الاختباري بهيئة أشكال إحصائية. إن صغر مقادير نسب الخطأ (RMS%) مثل 5.53)) و (6.32) بين معدل القيم بالتعاقبي بيّن مشروعيةَ هذه الطريقة للتطبيق في مناطق أخرى لها خصائص متشابهةٌ. قيمة المسامية الفعالة (الثانوية) والتشبع المائي لخزان الدمّام الأوسط قد حُسبت جيوفيزيائياً بواسطة معادلة "آرجي" وكانت القيم 22%)) و (0.9) بالتعاقب. إن هذه النتائج تقترب من المسامية المثالية للصخور الكاربوناتية المشبعة (27%)، وتتفق مع المعرفة السائدة بأن منطقة الدراسة هي منطقة تصريف لحوض شبچة الهايدروجيولوجي.


Article
USING VERTICAL ELECTRICAL SOUNDING IN BUILDING SITES INVESTIGATION; A CASE STUDY IN SOUTH OF BAGHDAD, IRAQ
استعمال التحري الكهربائي العمودي لدراسة مواقع إنشائية؛ دراسة حالة، جنوب بغداد، العراق

Authors: Jassim M. Thabit جاسم محمد ثابت --- Ahmed S. Al-Banna أحمد شهاب البناء --- Mundher D. Al-Awsi منذر ظاهر نصيف الأوسي
Journal: Iraqi Bulletin of Geology and Mining مجلة الجيولوجيا والتعدين العراقية ISSN: 18114539 Year: 2016 Volume: 12 Issue: 1 Pages: 31-39
Publisher: Ministry of Industry and Minerals وزارة الصناعة والمعادن

Loading...
Loading...
Abstract

Vertical Electrical Sounding is used for engineering purposes at Al-Jadiriya area, within Baghdad University site .Two different electrical resistivity techniques were applied using Schlumberger array. These are the vertical electrical sounding (VES) and cross vertical electrical sounding (CVES) technique. The measurements of VES were carried out at 38 points distributed as much as possible to cover the area. Three main layers were delineated; these are the top soil, unsaturated layer of clayey sand or silty sand and saturated layer of sand to clayey sand and sand mixed with gravel at some places. The resistivity of the top soil varies from 11 – 600 ohm.m, and thickness ranges from 0.7 – 2.8 m. The unsaturated layer has resistivity values varying from 46 – 320 ohm.m, and thickness ranging from 2.0 – 7.2 m. The resistivity of the saturated layer varies from 11 – 60 ohm.m, and thickness ranges from 4.6 – 13.8 m. There are also lenses in some places within the layers, 1.2 – 2.45 m. thick, which have high resistivity 800 – 900 ohm.m or low resistivity 9.6 – 29 ohm.m that may represent fill material and clay lenses respectively. The average depth of the groundwater surface ranges between 5 – 8 m. The measurements of CVES were taken along two perpendicular directions around fixed central point, at 5 points. The results are presented as radial graphs to show the variation of resistivity with direction; these graphs show that the sediments are heterogeneous in their vertical and horizontal distribution; especially for the top soil. Finally, it is concluded that three major causes of failures prevail in the buildings in Baghdad University. The first cause is the lateral inhomogeneity of the subsurface sediments. The second is the presence of lenses, and the third is the variation in the groundwater level. These failures may cause many engineering problems such as cracks in the foundation and walls of buildings.

استخدم الجس الكهربائي العمودي للأغراض الهندسية في منطقة الجادرية (موقع جامعة بغداد). إذ تم تطبيق اسلوبين هما الجس الكهربائي العمودي والجس الكهربائي العمودي المتقاطع، وباستعمال ترتيب شلمبرجر للأقطاب في 38 نقطة جس موزعة في منطقة الدراسة قدر المستطاع. واستخدم أسلوب الجس المتقاطع في خمسة مواقع ضمن منطقة الدراسة للتعرف على طبيعة تجانس الرواسب، حيث أجريت القياسات الكهربائية باتجاهين مختلفين لهما نفس مركز الترتيب. أظهرت المقاطع الجيوكهربائية وجود اربعة أنطقة كهربائية.النطاق الأول يمثل الطبقة السطحية التي تتألف من ترسبات الطين أو الغرين وبنسب مختلفة، والحاوية في بعض الأحيان على الرمل أو بقايا مواد البناء، تتراوح المقاومة النوعية لهذا النطاق من 600 – 11 اوم.متر، اما سمكه فيتراوح من 2.8 – 0.7 متر. النطاق الثاني يظهر بشكل عدسات غير مستمرة ويتراوح سمكة من 2.45 – 1.2 متر. أما مقاومتة النوعية فقد كانت منخفضة في بعض المواقع حيث تراوحت من 29 – 9.6أوم.متر وتشير إلى الترسبات الطينية الحاوية على نسبة قليلة من الرمل في بعض الأحيان. وفي بعض المواقع الأخرى تراوحت مقاومتها النوعية من 950 – 800 أوم.متر وهذه تشير إلى عدسات من الحصى أو بقايا مواد الدفن. ويمثل النطاق الثاني نطاق الترسبات الرملية غير المشبعة بالمياه الجوفية والحاوية على نسب مختلفة من الغرين أو الطين، وتتراوح مقاومتة النوعية من 320 – 46 أوم.متر، أما السمك فيتراوح بين 7.2 – 2 متر. النطاق الرابع يمثل نطاق المياه الجوفية في منطقة الدراسة ويتألف من الرمل الحاوي على نسب مختلفة من الغرين أو الرمل الحاوي على الطين، ومن المحتمل أن يكون حاوي على القليل من الحصى الناعم في بعض المواقع. تراوحت مقاومته النوعية من 60 – 11 أوم.متر، أما سمكه فيتراوح بين 13.8 – 4.6 متر. وتبين إن رواسب منطقة الدراسة غير متجانسة في خصائصها وفي توزيعها الأفقي والعمودي وذلك بناءاً على نتائج الجس الكهربائي العمودي المتقاطع. كذلك أظهرت المقاطع الجيولوجية عدم استمرارية الرواسب وتواجدها بشكل عدسات تتغير من موقع لآخر وضمن مسافات قليلة خاصة نطاق الطبقة السطحية وترسبات الرمل الطيني. وأظهرت منطقة الدراسة الوسطى عدم تجانس واضح في خواص ومكونات الترسبات الرملية غير المشبعة بالمياه الجوفية، حيث يكثر وجود الترسبات الرملية ذات المحتوى المائي القليل والحاوية على نسب متغيرة من الغرين، في حين تنتشر الترسبات الرملية الحاوية على الطين أو الرطوبة في الشمال الشرقي والجنوب الغربي. لذلك يعتقد بأن تشقق جدران بعض البنايات سببة تأثير عدم تجانس الرواسب حيث يؤدي ذلك إلى حدوث تجلس متباين في التربة التي تقام عليها البنايات، بالإضافة إلى تأثير ارتفاع منسوب المياه الجوفية في مواقع هذه البنايات ووجود تذبذب في منسوب هذه المياه.

Listing 1 - 9 of 9
Sort by
Narrow your search

Resource type

article (9)


Language

English (9)


Year
From To Submit

2016 (3)

2015 (5)

2014 (1)