research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Effect of Cavity in Sandy Soil on Load Distribution of Pile Group
تأثير الفجوة في الترب الرملية على توزيع الحمل لمجموعة ركائز

Authors: Mohammed Y. Fattah --- Karim H. Ibrahim. Al-Helo --- Hala H. Abed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 7 Part (A) Engineering Pages: 1733-1751
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The present study investigates the influence of presence of cavities on adjacent buildings especially in the case of piled structures. The presence of cavity affects on the bearing capacity and settlement of piled foundation. This paper presents an experimental study to investigate the behavior of model piles embedded in sandy soil of dry unit weight 16.8 kN/m3. Model piles were tested in a sand box with load applied by a hydraulic compression jack and measured by means of a load cell. The settlement of the piles was measured by means of two dial gages; three strain gages were attached on piles to measure the strains and to calculate the load carried by each pile in the group by the strain indicator. Two types of piles (single pile and group of piles (1x2)) were tested in the laboratory as a free standing pile group. A prototype of a cavity was used and placed adjacent to the piles at different distances from the pile centerline and different depths from the surface. The effect of variation of cavity locations (X), cavity depths (Y), and cavity diameter (d) on the load and settlement of the pile and groups of piles have been studied for all tests. It was found that the presence of the cavity in the soil reduces the ultimate failure load of the pile. For single pile, the reduction rate is about (10% to 60%). For pile group (1x2), the reduction rate is about (40% to 80%). As intuitively expected, induced pile axial force is largest for the case where the level of the cavity is located below pile tip because the cavity is located within the zone of large displacement

هذه الدراسة تبحث تأثير وجود الفجوات على المباني المجاورة خاصة في حالة المنشآت المستقرة على الركائز. إن وجود فجوة يؤثر على قابلية التحمل والهبوط للركيزة. يقدم هذا البحث دراسة تجريبية للتحقيق في تصرف نماذج ركائز مغروزة في تربة رملية ذات كثافة جافة تساوي (16.8 كيلونيوتن/م3). تم إختبار نموذج ركائز في صندوق تربة يحتوي على رمل مع حمل مسلط باستخدام مكبس ضغط هيدروليكي ويقاس بما يسمى خلية الحمل. وقد تم قياس الإنفعالات على الركائز بأستخدام مقياس الإنفعال، حيث تم ربط ثلاثة مقاييس انفعال لكل ركيزة يتم من خلالها حساب الحمل الذي تحمله كل ركيزة في المجموعة بواسطة مؤشر الأنفعال. تم إختبار مجموعتين من الركائز (ركيزة واحدة و مجموعة ركائز (1×2)) مختبريا ً بوصفها مجموعة ركائز حرة الإستناد. إستخدم نموذج مصغر لفجوة وضعت بالقرب من الركائز تبعد عن مركز الركيزة بمسافات مختلفة وكذلك بأعماق مختلفة عن سطح التربة. وقد تم دراسة تأثير اختلاف مواقع الفجوة بالإتجاه الأفقي (X) والأعماق بالإتجاه العمودي (Y) وكذلك قطر الفجوة (d) على كل من الحمل والهبوط لركيزة ولمجموعة ركائز في جميع الإختبارات. و قد وجود أن وجود الفجوة في التربة يقلل من التحمل الأقصى للركيزة. في الركيزة المفردة، يكون التقليل بالتحمل بحدود (10 – 60%) بينما في مجموعة الركائز (1 x 2) يكون التقليل بحدود (40 – 80%). و كما هو متوقع وجد أن الحمل المحوري على الركيزة أعلى ما يمكن عنما يكون مستوى الفجوة تحت مسنوى قاغدة الركيزة بسبب كون الفجوة واقعة ضمن المنطقة ذات الازاحة الكبيرة التي تسببها الركيزة.

Keywords

Cavity --- tunnel --- Pile group --- Sandy soil


Article
Detection of Buried Utilities Using Electrical Resistivity Imaging (ERI) Technique
الكشف عن الخدمات المدفونة باستخدام تقنية المقاومة النوعية التصويرية (ERI)

Authors: Hussein H. Karim --- Karim H. Ibrahim --- Mohammad A. H. Al-Rubaye
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 3 Part (A) Engineering Pages: 703-719
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The main objective ofthis paper is to show the ability of resistivity technique for investigating the buried utilities (their location and depth) for characterizing the surrounding subsurfacesoils. This study deals with implementation of 2-D electrical resistivity imaging (ERI) to detect the location of buried utilities existing in the Al-Dhubat Interchange in Kut city, Wassit Governorate south of Baghdad. Interpretation results of the subsurface investigation of this site have been compared with those obtained from conventional methods.Generally, the site is characterized by its gradual decreases in resistivity with depth with range of resistivity values (<1-140 ohm.m) which is mostly consisting of silty clay to clayey silt with lenses or pockets of medium, stiff and very stiff silty clay with sand or gravel. Several utility pipes with different diameters of φ1200, φ1100, φ600 and φ 400 mm with low resistivity values (<1 ohm.m) have been identified in the 2-D resistivity sections.The results of 1-D VES agree with that of 2-D ERI as their resistivity values decrease with depth. Besides, IP values for this site agree with the resistivity data as it is an indicator of clay content and their uniform sections reflecting the high moisture content and the effect of salts in the subsurface soil and water.

ان الهدف الأساسي لهذا البحث هو إظهار قدرة تقنية المقاومة النوعية الكهربائية للتحري عن الخدمات المدفونة (موقعها وعمقها) و توصيف التربة تحت السطحية المحيطة بها. تتعامل هذه الدراسة مع تطبيق طريقة المقاومة النوعية الكهربائية التصويرية ثنائية البعد 2-D ERI)) لكشف وتحديد موقع وعمق الخدمات المدفونة والموجودة في تقاطع الضباط في مدينة الكوت بمحافظة واسط جنوب بغداد. تمت مقارنة نتائج تفسير التحري تحت السطحي لهذا الموقع مع تلك التي تم الحصول عليها من الطرق التقليدية. عموما، يتميز الموقع بالتناقص التدريجي لقيم المقاومة النوعية مع العمق بمدى قيم تتراوح ما بين (أقل من 1- 140 أوم.م) مكونة معظمها من الطين الغريني إلى الغرين الطيني مع عدسات أو جيوب من الطين الغريني والرمل والحصى بقوام متوسط، وقاسي الى قاسي جدا. تم تحديد عدة أنابيب خدمة بأقطار مختلفة هي φ1200 و φ1100 و φ600 و φ 400 ملم مع قيم مقاومة نوعية منخفضة (أقل من 1 أوم.م) في مقاطع المقاومة النوعية ثنائية البعد. كانت نتائج الجس الكهربائي العمودي (1-D VES) في اتفاق مع تلك الخاصة بثنائية البعد (2-D ERI) طالما تقل قيمها مع العمق. علاوة على ذلك، كانت قيم IP لهذا الموقع في اتفاق مع بيانات المقاومة النوعية طالما تعد كمؤشر للمحتوى الطيني وعكست مقاطعها المتجانسة المحتوى العالي للرطوبة وتأثير الأملاح في التربة والمياه تحت السطحية.


Article
Plug Length Developed in Pipe Pile Embedded Within Partially Saturated Cohesionless Soils (Part 1)

Authors: Ali M. AL-Gharbawee --- Karim H. Ibrahim Al -Helo --- Mahmood Rashid Mahmood
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 7 Part (A) Engineering Pages: 1335-1346
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper presents an experimental study to investigate the change of plug length for pipe pile under different state of saturation and investigate the effect of number of pipe piles on plug length. The influence of matric suction (i.e., capillary stresses) in unsaturated zone is typically considered on the plug length of pipe piles.The experimental work consist of testing 20 models of pipe piles, these models divided into 4 different configuration of pipe piles; single pipe pile, group of double pipe piles, group of triple pipe piles and group of six pipe piles. All these models are loaded and tested under three different states; dry condition, fully saturated condition (i.e., matric suction equals to 0 kPa) and unsaturated conditions with three different matric suction values (6, 8 and 10 kPa), which are achieved by predetermined lowering of water table. The relationship between matric suction and depth of ground water table was measured in suction profile set by using three Tensiometers (IRROMETER). The soil, water characteristic curve (SWCC) was estimated by applying fitting methods through the program (Soil Vision).The results of experimental work demonstrate that the values of plug length decreased with increase in value of matric suction for the same configuration of pipe piles, and the values of plug length decreased with increase in number of pipe piles.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (3)


Year
From To Submit

2016 (1)

2015 (1)

2014 (1)