research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Electrochemical Behavior of Chemical Conversion of Coated Aluminum 1100Al in a Neutral Tartrate Solution
التصرف الكهروكيمياوي الناتج عن أنودة سبيكةالمنيوم 1100 في محلول الترترات المتعادل

Author: Khalid H. Rashid
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 18 Pages: 5640-5650
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

1100 Al specimens were anodically oxidized in different concentrations oftartaric acid-tartrate solution (pH=7) in 1, 1.75, 3.25 and 4 wt % at temperatures of30, 37.5, 52.5 and 60 ºC by applying a range of potentials of 30, 37.5, 52.5 and 60V at exposure times of 40, 47.5, 62.5 and 70 min.. These four variables aremanipulated through the experimental work using Box – Wilson experimentaldesign where second order polynomial model was proposed to correlate the studiedvariables with the thickness of anodic film of aluminum alloy (1100) to estimatethe coefficients of the proposed polynomial adopted via statistica software.Optimum conditions for achieving the maximum film thickness are obtained fromoptimizing the above correlation and are found as follows: temp. = 44ºC, acid conc.= 2.8 wt %, voltage = 43.6 V, time = 54.6 min.. Stagnate Solutions of 3, 5, 10 and25 wt % Nacl at 25ºC have been investigated using polarization technique atoptimum conditions for anodizing. The most important feature achieved was thegreat difference in behavior between the anodic polarization curves for bare andanodized aluminum in different concentrations of Nacl solutions. The corrosionrates for anodized specimens are lower than those for unanodized ones. Thepolarization behavior of anodizing specimens shows that the breakdown potentialsare shifted to more noble direction than bare specimens which is more pronouncedin 25 wt % Nacl solution due to anodizing.

تم أنودة نماذج من سبیكة الألمنیوم 1100 في تراكیز مختلفة من المحلول المتعادل لحامض, الترتریك و ملح ترترات الأمونیوم في ( 4 , 3.25 , 1.75 ,1 )% وزنا عند درجات ح رارة ( 30م و جھود مسلطة بمدى یتراوح بین ( 60 , 52.5 ، 37.5 ، 30 ) فولت عن د º (60 , 52.5 , 37.5فترات زمن تعرضیتراوح بین ( 70 , 62.5 ، 47.5 ، 40 ) دقیقة . الأربع المتغیرات تم معالجتھال ربط المتغی رات أع لاه ( Box- Wilson) م ن خ لال تص میم التج ارب العملی ة بأس تخدام طریق ةبمعادلة من الدرجة الثانی ة تش یر ال ى العلاق ة ب ین المتغی رات الأربع ة وس مك طبق ة الان ودة لس بیكةالألمنیوم ( 1100 ). من خلال أیج اد مع املات المعادل ة المتع ددة الح دود المقترح ة و المعتم دة ف يت م تحدی د الظ روف المثالی ة للحص ول عل ى أعل ى . ( Statistica analysis) البرنامج الإحصائيمº قیمة لسمك الطبقة بواسطة أختیار الأفضل للمعادلة المتعددة الحدود من الدرجة الثانیة وكانت 44درج ة الح رارة و 2.8 % وزن ا تركی ز الح امضو 43.6 فول ت جھ د مس لط و 54.6 دقیق ة زم نتع رض.أس تخدمت محالی ل كلوری د الص ودیوم الس اكنة بتراكی ز ( 25 ,10 , 5 , 3 ) % وزن ا عن دم التي درست بأستخدام تقنیة الأستقطاب عند الظروف المثلى للأنودة. º درجة حرارة 25


Article
Modelling and Optimization of Carbon Steel Corrosion in CO2 Containing Oilfield Produced Water in Presence of HAc

Authors: Khalid H. Rashid --- Aprael S. Yaro
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2015 Volume: 16 Issue: 2 Pages: 1-8
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Previously, many empirical models have been used to predict corrosion rates under different CO2 corrosion parameters conditions. Most of these models did not predict the corrosion rate exactly, besides it determined effects of variables by holding some variables constant and changing the values of other variables to obtain the regression model. As a result the experiments will be large and cost too much. In this paper response surface methodology (RSM) was proposed to optimize the experiments and reduce the experimental running. The experiments studied effects of temperature (40 – 60 °C), pH (3-5), acetic acid (HAc) concentration (1000-3000 ppm) and rotation speed (1000-1500 rpm) on CO2 corrosion performance of the regression model calculated by RSM. The experiments were conducted in saturated solution of CO2 with 3.5 % NaCl solution. STATISTICA program version 10 was used for data analysis. In conclusion a quadratic model is proposed to predict the effect of mentioned variables in CO2 environment.


Article
Effect of Acetic Acid on Electrochemical Behavior of Sealed AA2319-T3 Al-Alloys Anodized in Phosphoric Acid Electrolytes
تأثير حامض الخليك على السلوك الكهروكيمياوي لأنودة وختم مسامات سبيكة المنيوم 2319 في محاليل حامض الفوسفوريك الأليكتروليتية

Author: Khalid H. Rashid خالد حامد رشيد
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2015 Volume: 11 Issue: 4 Pages: 1-7
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present study investigates the effect of acetic acid on corrosion behavior and its potential of hydrothermally sealed anodized AA2319-Al-alloys. Anodizing treatment was performed in stagnant phosphoric acid electrolyte with or without addition of acetic acid. Hydrothermal sealing was carried out in boiling water for each anodized specimen. The open circuit potential of the unsealed and sealed anodized samples was examined using open circuit potential measurement for the purpose of starting in scanning polarization diagrams. The potentiostatic polarization technique measurements were performed to assess corrosion behavior and sealing quality (i.e., degree of sealing) of the unsealed and sealed anodized aluminum. It was shown that the potentiostatic anodic and cathodic polarization of anodized aluminum was sensitive to degree of seal, which was more efficient in the case of anodized aluminum formed in acetic-phosphoric acid electrolyte mainly due to their higher corrosion potential and lower corrosion current, generally passes lower anodic and cathodic currents obtained at sealing exposure time 60 min. This suggests a specific role of the species on the sealed anodized aluminum surface coating, which contributes to the increasing of the performance in terms of corrosion improvement. The present study clearly validates the beneficial role of acetic acid in phosphoric acid anodizing baths for the corrosion protection of AA2319-Al-alloys.

في هذا البحث تم دراسة التأثير لحامض الخليك على سلوك وجهد التآكل لسبيكة الألمنيوم AA2319 المأنودة المختومة المسامية بأستخدام الماء المغلي. تم إجراء عملية الأنودة في المحلول الأليكتروليتي الساكن لحامض الفوسفوريك بوجود أو بدون إضافة حامض الخليك. تم إنجاز عملية الختم (غلق المسامات) بطريقة الماء المغلي لكل نموذج مأنود. تم إجراء فحص جهد الدائرة المفتوحة للنماذج المأنودة المختومة وغير المختومة المسامية بأستخدام قياس جهد الدائرة المفتوحة لغرض البدأ في مسح مخططات الأستقطاب. تم إستخدام تقنية الأستقطاب للجهد الساكن لتعيين سلوك التآكل وجودة الختم (أي درجة الختم) للألمنيوم المأنودة غير المختوم والمختوم المسامية. من النتائج تبين أن عملية الأستقطاب الأنودي والكاثودي الساكن للألمنيوم المأنود كانت حساسة وتتأثر بدرجة الختم و كانت أكثر كفاءة في حالة الألمنيوم المأنود المتكون في المحلول الأليكتروليتي لحامض الفوسفوريك-الخليك بشكل رئيس نتيجة لجهدهم التآكلي الأعلى قيمة والأقل تيار التآكل , بعامة يسمح بمرور أقل تيارات أنودية وكاثودية حصلت عند زمن تعرض ختم 60 دقيقة. هذا يقترح للدور المحدد للدقائق على أكساء سطح الألمنيوم المأنود المختوم مساميته الذي يساهم في تحسين الأداء من وجهة نظر التآكل. أثبتت الدراسة الحالية بشكل واضح الوظيفة المفيدة لحامض الخليك في أحواض الأنودة لحامض الفوسفوريك لحماية التآكل لسبيكة الألمنيوم AA2319.


Article
Electrochemical Behavior of Chemical Conversion Coated Aluminum ASA6061in Chromic Acid

Loading...
Loading...
Abstract

The corrosion behavior of bare and chemical conversion coated (through anodizing) aluminum AS4 6061 in stagnant chromic acid solutions. Solutions of 2, 6 & lO wt% Cro3, at 45°C have been investigated using polarization ion technique. The anodizing experiments were conducted under fixed conditions of 35 minute exposure time and 30 volt supplied voltage. The most important feature achieved was the great d(fference in behavior between the anodic polarization curves for bare and anodized aluminum in different concentrations of chromic acid solutions.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (3)

Arabic and English (1)


Year
From To Submit

2015 (2)

2010 (1)

2007 (1)