research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
TILTED FIBER BRAGG GRATINGS (TFBGs) TEMPERATURE SENSING ELEMENT USING 244NM Ar+ LASER WRITTEN ON SIDE HOLE FIBER
عنصر تحسس حرارة لمحزز براغ الليفي المائل مستخدما ليزر ايون الاركون 244 نانومتر مكتوب على ليف ذو ثقوب جانبية

Authors: Xinyong Dong --- Khalil I. Hajim خليل ابراهيم حاجم --- Jingyi Yang --- Riyadh Khlf Ahmed رياض خلف احمد
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2015 Volume: 8 Issue: 3 Pages: 116-123
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Tilted Fiber Bragg Gratings (TFBGs) are designed and implemented at the 1550 nm communication window in Institute of Optoelectronic Technology, China Jiliang University, Hangzhou, China. They are experimentally demonstrated to work as high sensitive temperature sensing element. The tilted fiber Bragg gratings of 10 mm were written on the core of 7-cm and 26-cm hydrogen loaded side hole fibers using 244 nm frequency doubled 488 nm Argon ion laser based on phase mask technique. The transmission spectrum of the first TFBG sensing element showed two resonant dips at 1579.614 nm and 1582.502 nm respectively. The transmission spectrum of the second TFBG sensing element showed two resonant dips at 1579.108 nm and 1580.304 nm. The achieved sensitivity is about 10 pm / °C. To the best of our knowledge our finding regarding setup with low cost is very close to the performance of other types of Fiber Bragg Gratings (FBGs) (1).

محززات براغ الليفية المائلة تم تصميمها وتنفيذها في اطار حزمة الاتصالات 1550 نانومتر. تم تجريب المتحسسات ان تعمل كعنصر تحسس حرارة ذو استشعارية عالية. كتب محزز براغ الليفي المائل بطول 10 ملي متر على نواة الليف ذو ثقوب جانبية وبطول 7سم و26 سم المحملين بالهيدروجين مستخدما ليزر ايون الاركون 244 نانومتر لمضاعف التردد 488 نانومتر باستخدام طريقة القناع الطوري. اظهر طيف الارسال لمحزز براغ الليفي المائل الاول انخفاضات عند 1579.614 نانومتر و1582.502 نانومتر. اظهر طيف الارسال لمحزز براغ الليفي المائل الثاني انخفاضات عند 1579.108 نانومتر و 1580.304نانومتر. ان الاستشعارية المنجزة حوالي 10 بيكومتر/ م°. الى حد معرفتنا ان الاستشعارية المنجزة لهذا التصميم المنخفض الكلفة قريب جدا من اداء الانواع الاخرى من محززات براغ الليفي (1).


Article
An In Vitro Histological Study of Human Skin Wound Soldering Using 980 nm Diode Laser in Continuous versus Pulsed Modes.
دراسة نسيجية خارج الجسم الحي للصاق جروح جلد الانسان باستخدام ليزر اشباه الموصلات 980 نانومتر بنمط عمل مستمر مقارنة بنمط عمل نبضي .

Authors: Ahmed A. Abbood أحمد عبد الرزاق عبود --- Khalil I. Hajim خليل ابراهيم حاجم --- Zakaria Y. Arajy زكريا العريجي
Journal: Iraqi Journal of Laser المجلة العراقية لليزر ISSN: 18121195 Year: 2015 Volume: 14 Issue: B Pages: 1-10
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Abstract: Background: Laser skin wound soldering offers many distinct advantages over conventional closure and laser welding techniques. Objective : to compare the histological effects of human skin wound soldering using 50 % human albumin solder and compound charcoal photosensitiser with 980 nm diode laser acting in various modes of action and parameters. Study Design/Materials and Methods: In this in vitro experimental study , Multiple 3-4 cm long full thickness incisions in a specimen of human skin were soldered using a 4 mm spot diameter beam of 980 nm diode laser(at different laser parameters and modes of action) with 50 % human albumin solder mixed with the compound charcoal at 5 % W/V concentration .After obtaining a successful wound soldering , the wound edge were excised and then studied histologically. Results: Although a single pulse per shot , spot by spot soldering technique has resulted in a weaker soldering of the wound experimentally, yet it was less tissue harmful than the continuous mode laser, inspite that the later had resulted in a stronger wound soldering. A strong wound closure didn't happen using repetitive pulsed laser mode at any of the tested parameters or action modes. Conclusion: A single spot by spot , pulsed 980 nm laser wound soldering is less tissue harmful than the continuous mode laser soldering although it has resulted in a weaker soldered wound initial tensile strength.

الخلاصة: المقدمة : الصاق الجروح بمساعدة الليزر ذو مزايا وفوائد عديدة مقارنة باغلاق الجروح بالطرق التقليدية أواللحام بالليزر. الغاية:دراسه التاثير النسيجي للصاق جروح جلد الانسان باستخدام خليط من لاصق 50% البومين بشري و كاربون مركب بمساعدة ليزر أشباه الموصلات 980 نانومتر باستخدام انماط عمل وطاقات ليزر مختلفة. المواد وطرائق العمل: لقد استخدم في هذه الدراسة خارج الجسم الحي عينات من جلد الانسان حيث تم استحداث عدة جروح طولية قطعية بطول 3-4 سم كاملة العمق خلال عينة الجلد هذه ثم تمت محاولة غلقها باللصق بتعريضها لليزر اشباه الموصلات بطول موجي 980 نانو متر وقطر البقعة 4 ملم باستخدام طاقات وأنماط عمل ليزر مختلفة مع اضافة 50% ألبومين بشري يحتوي على 5 % كربون مركب كعامل متحسس للضوء.لقد تمت مقارنة وتحليل النتائج مختبريا ونسيجيا. النتائج: ان لصاق الجروح بالليزر تكون اقل ضررا على الانسجه عندما يستخدم نمط عمل نبضي بطريقة نقطية منفرده ولكنها اضعف من حيث المتانه مقارنة باللصق بالليزر عندما يعمل الليزر بنمط عمل مستمر . لم ينجح اللصق بالليزر عندما يعمل بطريقة النبض المتكرر . ألأستنتاجات: أن لصق جروج جلد الانسان باستخدام الليزر تكون اقل ضررا على الانسجه ولكنها اقل متانة ايضا عندما يعمل الليزر بنمط عمل نبضي بطريقة لصق نقطية مقارنة بانماط العمل الاخرى.هناك الحاجة لإجراء المزيد من الدراسات المستقبلية قبل الاستخدام والتطبيق الفعلي ألسريري لهذه الطريقة الجديدة .

Keywords


Article
Effect of Nd-YAG, XeCl, and Nitrogen Laser Radiation on Human Aorta , and Some Arterial Tissues
تأثير أشعاع ليزر النديميوم-ياك وكلوريد الزينون و النايتروجين على الشريان الاورطي البشري وبعض الانسجة الوريدية

Loading...
Loading...
Abstract

The effect of laser radiation on human aorta, coronary, and pulmonary arteries, and pulmonary veins has been investigated. Xenon-Chloride (eximer), Nitrogen, and Nd-YAG pulsed lasers of wavelengths 308, 337, and 1060 nm respectively were used. Their effects on fresh postmortem tissues, normal and diseased, was studied. The diameter and depth of ablation of the exposed tissues, in air, were measured as a function of many factors related to the type of laser and nature of the tissue. The effect of properties of the applied lasers, such as average power density and deposited energy density, on the exposed tissue surface were studied. The increase of these two parameters cause an increase in the depth and diameter of ablation. However the diameter increases until it reaches a saturation value defined by the laser spot cross section. The laser effects were studied as functions of the tissues’ nature and thickness. Normal tissues were found to have higher values of ablations’ diameters and depths in comparison in with atheromatous tissues. It has been found also that the laser ablation decreases as the tissue thickness increases. It has been found that optical properties of the tissues, such as absorption coefficient, play important role in laser – tissue interaction. When the absorption increases the effects of laser increase too. Light microscopy showed that clean cuts with histological normal edges were produced when UV lasers had been applied, with no thermal effects on the tissues. However, it was observed that the thermal side effect reached more than 200 μm on the area around the cuts when the near – infrared (Nd-YAG) laser was used.

لقد تمت دراسة تأثير اشعاع الليزر على الشرايين الاورطي والتاجي والرئوي والوريد الرئوي. واستخدمت ليزرات كلوريد الزينون والنايتروجين والنديميوم – ياك , ذات الاطوال الموجية 308 و 337 و1060 نانومتر على التوالي. و درست تأثيراتها على انسجة هذه الاوعية الدموية السليمة والمريضة الطازجة بعد الوفاة. ولقد قيس قطر الاستئصال وعمقه (الاعظم) للانسجة المعرضة (في الهواء) واعتمادها على عدة عوامل مرتبطة بنوع الليزر و طبيعة النسيج. و تمت دراسة تأثير خواص الليزرات المستخدمة مثل متوسط كثافة القدرة وكثافة الطاقة المترسبة على سطح الانسجة المعرضة. ان زيادة هذين العاملين بؤدي الى زيادة في قطر و عمق الاستئصال. غير ان قطر الاستئصال يزداد حتى يصل الى حد الاشباع الذي يتحدد بمقطع حزمة الليزر. وعند دراسة تأثير طبيعة وسمك الأنسجة، فقد وجد بأن السليمة تمتلك قيما اعلى لقطر وعمق الاستئصال مقارنة بالانسجة المصابة بتصلب عصيدي. ووجد ايضا بأن الاستئصال يقل بزيادة سمك الانسجة المعرضة. كما وجد بأن الخواص البصرية للانسجة مثل معامل الامتصاص تلعب دورا مهما في تفاعل الليزر مع الانسجة. فبزيادة الامتصاص تزداد تأثيرات الليزر ايضا. وبينت الدراسة الحالية باستخدام المجهر الضوئي حدوث قطع واضح و محدد المعالم و ذو حافات اعتيادية و بدون تأثيرات جانبية حرارية على الانسجة عند استخدام ليزرات الاشعة فوق البنفسجبة. ولكن لوحظ بأن التأثيرات الجانبية الحرارية تبلغ اكثر من 200 مايكرومتر على المساحة حول القطع عند استخدام ليزر الاشعة تحت الحمراء – القريبة (النديميوم – ياك).

Keywords


Article
OPTICAL FIBER BRAGG GRATING TEMPERATURE SENSOR
محزز براك للألياف البصرية المتحسس للحرارة

Loading...
Loading...
Abstract

In this work, uniform Fiber Bragg Grating (FBG) temperature sensor system were implemented and investigated due to measurement of the Bragg wavelength shift. An (FBG) is an optical fiber in which the refractive index in the core is perturbed by Germanium, forming a periodic index modulation profile. When light is guided through a fiber granting, it is scattered at each diffraction plane, except at those wavelengths which satisfy the Bragg resonance conditionAn important application of FBG technology is sensing. The reflected wavelength from the FBG depends on physical properties such as temperature. By integration the FBG with broadband light, the shift in peak reflectivity wavelength can be used as a measure for the temperature. It has been shown from the results that the FBG is very sensitive to variations in temperature degrees and the sensitivity was (1pm/0.1°C), also observed from the results, the relation between the shifted Bragg wavelength and temperature degrees was linear.

في هذا البحث تم تحقيق منظومة تحسس للحرارة باستخدام محززالليف البصري نوع براغ أستناداً على قياس إزاحة الطول الموجي لمحزز براغ. محزز الليف البصري نوع براغ المستخدم في العمل الحالي يصنع بواسطة تشويب الجرمانيوم في قلب الليف البصري المشكل كمعامل أنكسار دوري.محزز الليف البصري نوع براغ أستنتج بواسطة أشارة ليزرية شبه موصلة ذات حزمة واسعة ومتحسس محزز الليف البصري نوع سيراميك. الأزاحة في الطول الموجي أستخدمت كقياس لدرجات الحرارة المتغير. أستخدام المتحكم الليزر دايود في تحديد قيم التيار، من خلال قيم التيار، القدرة للأشارة تحدد .أستخدام المتحكم الكهربائي لدرجة الحرارة في أستقرار الليزر دايود وتوليف الطول الموجي بواسطة تنظيم درجة الحرارة، من خلال التغيير في درجات الحرارة من خلال المتحكم الكهربائي بدرجة الحرارة يقود الى قيم مختلفة من القدرة للأشارة، هذه الأختلافات في قيم القدرة تقود الى تغير في قيمة الطول الموجي نوع براك.قد بين من النتائج بأن متحسس محزز الليف البصري نوع براغ هو جداً حساس الى التغيرات في درجات الحرارة والتحسسية كانت (1pm/0.1°C) أيضاً نحن لاحظنا من النتائج، العلاقة بين الطول الموجي المشفت نوع براغ ودرجات الحرارة كانت خطية.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2015 (2)

2014 (1)

2008 (1)