research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Experimental Investigation of Heat Transfer and Pressure Drop in Square Metal Packed Duct with Different Boundary Heating
دراسة عملية لأنتقال الحرارة وفقدان الضغط في وسط مسامي معدني ذو مقطع مربع باختلاف حدود التسخين

Author: Kifah H. Hilal
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 6 Pages: 1082-1107
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper presents experimental results of forced convection heat transfer and pressure drop across ( 12.5 * 12.5 * 100 cm ) square packed duct. The pad made of forty- eight metallic wrapping coil unit with (0.98 porosity ) and (26 W/m.°C thermal conductivity ). The local surface duct temperature and local heat transfer coefficientdistribution, Nusselt number, pressure drop and friction factor were measured for heat flux (0.56 to 2.73 kW/m2) ,Reynolds number (40339 to 54797 ) and three boundary condition of heat flux imposed on duct surface . It was found that Nusselt number increases as Reynold number, heat flux and number of duct surface exposed to heat flux increases. Nusselt number in packed duct is to be ( 1.2 , 1.19 ) times higher thanthe empty ducts at heating all surface and top & bottom surface of packed duct respectively. Many empirical relation between Reynold number, Nusselt number and pressure drop obtained in this study.


Article
An Experimental Study on Heat Transfer Enhancement for Porous Heat Exchange in Rectangular Duct
دراسة تجريبية لزيادة انتقال الحرارة لتبادل حراري مسامي في مجرى مستطيل المقطع

Authors: Kifah H.Hilal --- Adel M.Saleh --- Muntaha H.Ebraheem
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 11 Part (A) Engineering Pages: 2788-2802
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Forced convection heat transfer of air in porous rectangular duct was investigated experimentally . The pad consist of (zig-zag ) metallic wire mesh insert with two different porosities ( ε) namely ( 0.97 ) and ( 0.99) .The experiments were carried out for Reynolds number (7682,12497 and 17323 ) and constant heat flux (192,297 and 422 W/m2 ) .The results indicated that Nusselt number was increased with increasing Reynolds number and heat flux but decreased with increasing pad porosity .The Nusselt number in the porous duct was increased up to (144% ) for (ε=0.97) and (72% ) for (ε=0.99) when compared to clear duct at the same tested condition . For optimization between heat transfer enhancement and pad weight added into clear duct , it is found that [ (Nuporous - Nuclear ) / weight of pad ] equal to (84.34 ) and ( 40.49 ) for (ε=0.99 and ε=0.97) respectively and this is good improvement in heat transfer through porous rectangular duct and reducing size and weight of original duct .

انتقال الحرارة بالحمل القسري للهواء المار خلال مجرى مسامي مستطيل المقطع تم دراسته عمليا في هذا البحث . تتكون الحشوة من مشبك سلكي معدني متعرج بمسامية تتراوح بين( 0.97 ، 0.99 ) . اجريت التجارب لرقم رينولدز Re) ) ( 17323 , 12497 , 7682 ) وفيض حراري ثابت ( q ) ( 422 , 297 , 192 واط / م2 ) . بينت النتائج ان رقم نسلت (Nu ) يزداد بزيادة رقم رينولدز (Re ) والفيض الحراري (q ) ولكن يقل بزيادة مسامية الحشوة (ε ) . رقم نسلت للمجرى المسامي يزداد بمقدار (144 % ) عند (ε=0.97 ) و (72 % ) عند (ε=0.99) عند مقارنته مع المجرى الخالي من الحشوة عند نفس الظروف التشغيلية ومن المفاضلة بين الزيادة في انتقال الحرارة ووزن الحشوة المضافة الى المجرى الخالي ، وجد ان[( Nuخالي - Nuمسامي ) / وزن الحشوة المضافة] يساوي ( 84.34 ) و ( 40.49 ) عند مسامية (0.99 ) و (0.97 ) على التوالي وهذا يعتبر تحسين جيد في انتقال الحرارة خلال المجرى المستطيل المقطع اضافة الى تقليل حجم ووزن المجرى الاصلي .


Article
AN EXPERIMENTAL STUDY OF FORCED CONVECTION HEAT TRANSFER IN A VERTICAL PACKED DUCT
دراسة عملية لانتقال الحرارة بالحمل ألقسري في مجرى مسامي عمودي

Author: Dr.Kifah H.Hilal د.كفاح حامد هلال
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2017 Volume: 30 Issue: 1 Pages: E153-E164
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

This paper investigate the effect of tilt angle on heat transfer through (12.5*12.5*100 cm) packed duct experimentally. The duct was at a vertical position ,heated at constant heat flux varying from (0.2 to 0.5 kW/m2) and the tests were done for Reynolds number (8010 to 18400). The porous duct were packed by ( 12 piece) of commercial galvanized steel wire mesh and arranged courrgeatly in (V end) shape (zig-zag) at the center line axial with pad porosity (Ɛ=0.99). The results showed that Nusselt number was increasing with increasing heat flux and Reynolds number. Average Nusselt number obtained in this work at vertical duct was increased up to ( 150% ) when compared to empty duct and up to ( 40% ) when compared to horizontal duct at the same tested condition. This results indicated that heat transfer in vertical duct is enhanced than horizontal duct.

تشمل الدراسة تأثير زاوية ميل مجرى مسامي مستطيل بأبعاد (12.5*12.5*100 cm)على انتقال الحراة عمليأ. زاوية ميل المجرى المسامي (90°) عن الافق (عمودي) وجداره مسخن بفيض حراري ثابت يتغير)(0.2 to 0.5 kW/m2 واجريت التجارب لمدى رقم رينولدز بين(8010 to 18400 ) . تتكون الحشوة من 12 قطعة من مشبك سلكي معدني رتبت على شكل ( V )عند الاطراف متعرج وتم تثبيتها من الوسط وكانت مسامية الحشوة (Ɛ=0.99) . بينت النتائج ان رقم نسلت يزداد بزيادة رقم رينولدز والفيض الحراري . كذلك بينت النتائج ان رقم نسلت للمجرى المسامي العمودي يكون اعلى بنسبة ( 40% ) عن الوضع الافقي ،ويكون اعلى بنسبة ( 150 % )عن المجرى الفارغ عند نفس الظروف التشغيلية.


Article
Evaluation of Correlations for Mixed Convective Heat Transfer in a Porous Vertical Cylindrical Annulus
دراسة عددية في انتقال الحرارة بالحمل المختلط خلال حلقة عمودية مملوءة بوسط مسامي

Authors: Kifah H. Hilal كفاح حامد هلال --- Eman A. Salih ايمان عبود صالح
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2011 Issue: 17 Pages: 212-229
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

This paper presents a numerical investigation of mixed convection heat transfer in vertical packed annulus with air as the working fluid . The inner cylinder is at constant temperature and the outer cylinder is insulated . The flow in the packed annulus is governed by the usual Darcy model . The analyses were carried out in the range of 10 < Ra* < 100 , 1 < Pe < 10 and 0.2 < A < 1 . The effect of each parameter on Nusselt number was explained and shown that it is increased as (Ra*) increased and (A) increased . The best analysis correlation obtained for average Nusselt number was as follows :

هذا البحث يبّين اجراء دراسة عددية، لانتقال الحرارة بالحمل المختلط للهواء المارخلال حلقة عمودية مملوءة بوسط مسامي ، الجدار الداخلي للحلقة ذو درجة حرارة ثابتة، بينما الجدار الخارجي للحلقة كان معزولاً .ان المعادلة المستخدمة في الجريان خلال الوسط المسامي هي معادلة دارسي . وقد تمت الدراسة لمدى رقم رالي المطور 10 < Ra* < 100 ورقم بكلت 1 < Pe < 10 ونسبة باعية 0.2 < A < 1 وبينت تأثير كل منها على رقم نسلت ، حيث انه يزداد بزيادة رقم رالي المطور (Ra*) والنسبة الباعية (A) . ان افضل علاقة تم الحصول عليها من التحليلات كانت كما يأتي :


Article
EXPERIMENTAL STUDY OF HEAT TRANSFER ENHANCEMENT BY USING POROUS MEDIA IN DOUBLE TUBE HEAT EXCHANGER
دراسة عمليه لتحسين التبادل الحراري باستخدام وسط مسامي لمبادل حراري مكون من اسطوانتين متحدتي المركز

Authors: Dr. Kifah H . Hilal د.كفاح حامد هلال --- Noor Samir Lafta نور سمير لفته --- Dr.Isbeyeh W. Maid Dr. Kifah H . Hilal ** Noor Samir Lafta د.اصبيح وسمي مايد
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2017 Volume: 30 Issue: 1 Pages: E44-E59
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

Forced convection heat transfer in counter flow heat exchanger which uses porous media to enhance heat transfer through it, has been investigated experimentally in the present work.Theexperimental work included the design of double pipe heat exchanger with the dimension of (length 1.11m, 0.063 outer pipe diameter and 0.031m inner pipe diameter). Alumina(2.5mm diameter) as a porous media is added in heat exchangerat three case: inner porous tube (IP) , outer porous tube (OP) and inner- outer tubes (IOP) .Cold andhot water are used as working fluid to transfer heat through outer and inner pipe respectively. The experiment are conducted at hot water mass flow rates (0.0166-0.0833 Kg/s),cold water mass flow rates ( 0.05-0.116 Kg/s) ,inlet temperatures of hot water (47, 55ᵒC) andinlet temperatures of cold water(20, 25 ᵒC).The results are obtained for range of Reynolds number to hot water (1144< Re<6241) and cold water (3939البحث الحالي هو دراسة عملية لانتقال الحرارة بالحمل القسري خلال مبادل حراري مملوء بوسط مسامي لتحسين انتقال الحرارة خلاله. تضمن البحث تصميم مبادل حراري من نوع اسطوانتي متحدتي المركز بأبعاده (1.11m طول, قطر الاسطوانة الداخلية 0.031m , وقطر الاسطوانة الخارجية 0.063 m ). أستخدمت كرات من من الالومينا بقطر (2.5mm ) كوسط مسامي في المبادل الحراري بثلاثه حالات: في الاسطوانه الداخليه (IP), في الاسطوانه الخارجيه (OP), في كلا الاسطوانتين(IOP).. تم استعمال الماء البارد والحار كمائع ناقل للحرارة من جانب الاسطوانه الخارجيه والداخلية على التوالي. جرت الدراســـــــة بمعدل تدفق للماء الحـار تتراوح بين (kg/s 0.833 – 0.0166) ومعدل تدفق للماء البارد (kg/s 0.116 – 0.05)و درجه حراره الدخول للماء الحار فهي (47, 55 ᵒC) ودرجه حراره الدخول للماء البارد (25, 20 ᵒC). بينت لنتائج التي تم الحصول عليها هي ضمن رقم رينولد(1144< Re<6241) للماء الحار و(3939


Article
Effect of Solid Particle Properties on Heat Transfer and Pressure Drop in Packed Duct
تأثير خصائص الحشوة الكروية على انتقال الحرارة وفقدان الضغط في مجرى مسامي

Authors: Muthanna L. Abdulla مثنى لطيف عبد الله --- Salman H. Omran سلمان حسين عمران --- Kifah H. Hilal كفاح حامد هلال
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2013 Volume: 9 Issue: 2 Pages: 33-47
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work examines numerically the effects of particle size, particle thermal conductivity and inlet velocity of forced convection heat transfer in uniformly heated packed duct. Four packing material (Aluminum, Alumina, Glass and Nylon) with range of thermal conductivity (from200 W/m.K for Aluminum to 0.23 W/m.K for Nylon), four particle diameters (1, 3, 5 and 7 cm), inlet velocity ( 0.07, 0.19 and 0.32 m/s) and constant heat flux ( 1000, 2000 and 3000 W/ m 2) were investigated. Results showed that heat transfer (average Nusselt number Nuav) increased with increasing packing conductivity; inlet velocity and heat flux, but decreased with increasing particle size.Also, Aluminum average Nusselt number is about (0.85,2.2 and 3.1 times) than Alumina, glass and Nylon respectively. From optimization between heat transfer and pressure drop through packed duct, it is found thatfinest ratio (Nuav / Δp) equal to (19.12) at (Dp = 7 cm, inlet velocity = 0.07 m/ s and 3000 W/m2 heat flux) with Aluminum as packing material.

اجريت في هذا البحث دراسة عددية لتأثير قطر الجزيئة المكونة للحشوة المسامية والموصلية الحرارية لها وسرعة الهواء الداخل على انتقال الحرارة بالحمل القسري خلال مجرى مسامي مسخن بفيض حراري ثابت. أربعة أنواع من الحشوات مصنوعة من ( الالمنيوم، الالومينا، الزجاج والنايلون) وبمدى موصلية حرارية يتراوح بين (200W/m.Kللالمنيوم الى 0.23W/m.K للنايلون) وبقطر جزيئة (1,3,5,7 cm) وسرعة ( 0.07, 0.19, 0.32 m/s) وبفيض حراري ثابت مقداره ( 1000,2000,3000 W/m2) تم اختبارها. لقد بينت النتائج ان انتقال الحرارة ( معدل رقم نسلت Nuav) تزداد بزيادة الموصلية الحرارية للحشوة المسامية وسرعة الهواء الداخل والفيض الحراري، ولكن يقل بزيادة قطر الجزيئة. معدل رقم نسلت (Nuav ) لحشوة الالمنيوم أعلى ب ( 3.1, 2.2, 0.85 مرة) من ( الالومينا، الزجاج والنايلون) على التوالي. من المفاضلة بين انتقال الحرارة وفقدان الضغط خلال الحشوة المسامية، نجد أن أفضل نسبة ( Nuav / Δp) تساوي ( 19.12) عند ( Dp = 7cm، U = 0.07 m/s وفيض حراري 3000 W/m2(، واستخدام الالمنيوم كحشوة مسامية داخل المجرى.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (5)

Arabic and English (1)


Year
From To Submit

2017 (2)

2014 (1)

2013 (1)

2012 (1)

2011 (1)