research centers


Search results: Found 14

Listing 1 - 10 of 14 << page
of 2
>>
Sort by

Article
Study Of Causative Agents Of Cervicitis In Women Attending Gynecologic Outpatient Department In Najaf City
دراسة مسببات التهاب عنق الرحم لدى النساء الوافدات إلى قسم النسائية في مستشفيات محافظة النجف

Author: Jaafar K. Naama*MBChB, PhD
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2008 Volume: 11 Issue: 1 Pages: 166-174
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

This study included 450 cervical swabs collected from women suffering from cervicitis attending the gynecological/obstetrics department at two hospitals in Najaf (Al-Zahraa maternity and children hospital and AL- Hakeem general hospital) between April 2005 to January 2006. A total of 628 isolates were obtained these included high percentage (58.4%) of bacterial cervicitis especially Staphylococcus aureus isolates (23%), followed by Candida albicans 23.4 %, Trichomonans vaginalis 7%. The main age group of disease occurrence was 25-34 years of age (29.9%), and was more common among patients of urban residency and most women were of non-educated group. It was found that the bacterial infection plays an important and significant role (P<0.05) in the causation of post-abortion cervicitis specially at 0-8 weeks of pregnancy (57%), whereas contraceptive using was considered as an important predisposing factor for cervicitis (P<0.05).

تضمنت الدراسة 450 مسحة من عنق الرحم من نساء مصابات بالتهاب عنق الرحم اللواتي حضرن إلى قسم النسائية والتوليد في مستشفى الزهراء التعليمي للولادة والأطفال ومستشفى الحكيم العام في النجف، في الفترة بين نيسان 2005 إلى كانون الثاني 2006. مجموع المسببات المعزولة كان 628 وكانت النسبة الأكبر المسببات البكتيرية (58.4%)، أمّا نسبة الكانديدا فكان (23.4%)، ونسبة الترايكوموناس (7%). النسبة الأكبر من المصابات كانوا في المجموعة العمرية 25-34 (29.9%)، وأكثر المصابات من سكنة المدينة ومن غير المتعلمات. وجد أنّ الإلتهاب البكتيري يلعب دوراً مهماً بالتسبب بالتهاب عنق الرحم ما بعد الإسقاط، وخاصة في الأسابيع (0-8) من الحمل (57%)، وكذلك فإنّ استخدام موانع الحمل له دور مهم بالتسبب بالتهاب عنق الرحم.

Keywords


Article
Al-Hijamah Cupping Therapy

Author: *Yesar MH AL- Shamma, MBChB, PhD(UK)
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2009 Volume: 12 Issue: 1 Pages: 49-56
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Cupping therapy has been practiced for thousands of years ago for the treatment of some disease and pain. It is a form of acupuncture that focuses on the movement of blood, energy - called Qi - and body fluids, such as lymph - which circulates around the body's tissues. Oriental medicine states that pain is due to stagnation of these systems. This stagnation can be a result of injury or stress. Cupping is believed to stimulate flow of blood, lymph and Qi to the affected area. Its uses include relieving pain in the muscles, especially back pain from stiffness or injury, and clearing congestion in the chest, which can occur with colds and flu. This study was carried out to investigate the effect of Al-Hijamah on mean blood pressure(MBP), heart rate(HR) and blood parameters like hemoglubin(Hb) %, platelets count, white blood cell(WBC) count, Neutophils%(N), Eosinophils(E)%, Basophils(B)%, Monocytes(M)%, and Lymphocytes(L)% before and after the performance of Al-Hijamah. The result indicate that there are significant decrease in MBP, WBC count, N% and M%. However there are significant increase in Hb%, platelets counts and L% but HR and E% were showed no significant changes

استخدمت الحجامة قبل آلاف السنين لعلاج بعض الإمراض ولتخفيف بعض الآلام في جسم الإنسان.وتعود طريقة الحجامة حسب التصنيف الطبي إلى طريقة الوخز المباشر والذي يعتمد على حركة الدم والطاقة والسوائل في الدورة الدموية للإنسان. وقد أقر الطب الشرقي منذ زمن بعيد إن سبب الآلام هو ركود الدم والطاقة و السوائل اللمفاوية داخل بعض المنعطفات والأجهزة في جسم الإنسان والذي يؤدي بدوره إلى نتائج رديئة تسبب الأذى الكبير والإجهاد لدى الإنسان. وقد اعتقد العلماء أن الحجامة تحفز انسياب الدم والسوائل اللمفاوية والطاقة إلى المنطقة المصابة وعلى هذا الأساس فان الحجامة تزيل الألم في العضلات وبالأخص في منطقة الظهر وذلك بإزالة التخشب والتقلصات والتشنجات العضلية والتي تكون سببا لهذه الآلام ,كذلك يرى الباحثون أن الحجامة تزيل الاحتقان في منطقة الصدر والذي يصاحب أمراض البرد والأنفلونزا.تبين هذه الدراسة تأثير الحجامة على ضغط الدم وضربات القلب ونسبة الهيموكلوبين وعدد كريات الدم البيضاء وعدد الأقراص الدموية ونسبة النيوتروفيل والأزينوفيل والمونوسايت واللمفوسايت قبل وبعد إجراء الحجامة وقد أظهرت النتائج أن هناك انخفاضا معنويا في معدل ضغط الدم وعدد كريات الدم البيضاء ونسبة النيوتروفيل والمونوسايت بينما أظهرت النتائج ارتفاعا معنويا في نسبة الهيموكلوبين وعدد الأقراص الدموية و نسبة اللمفوسايت ولم يحصل أي تغيير معنوي في ضربات القلب ونسبة الازينوفيل .


Article
Physiological Healing Power Of The Cornea After Foreign Body Exposure

Author: Yesar MH.Al.- Shamma. MBChB, PhD (UK)
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2009 Volume: 12 Issue: 1 Pages: 90-97
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Keywords


Article
Electrophysiological Study Of The Effect Of Posture On The Sympathetic Skin Response In Normal Subjects And In Diabetic Patients

Author: Yesar M.H.Al-Shamma MBChB, PhD
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2008 Volume: 11 Issue: 1 Pages: 284-300
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Thirty nine diabetic patients, of both insulin dependent and noninsulin dependent types, and thirty four age and sex matched control subjects were included in this study in an attempt to clarify the effect of changing posture on the peripheral nerves in both groups and to clarify the effect of diabetes on the peripheral nerve by using electromyography. Peripheral nerve dysfunction was evaluated by clinical examination, and electrophysiological testing of the somatosensory and autonomic peripheral nerves in supine and in standing position.The sympathetic skin responses (SSR) evoked by electrical stimulation of right and left median nerves and right and left common peroneal nerves were also recorded and analyzed. The sympathetic skin response test of diabetic patients show a significant reduction in latency and amplitude of the SSR in both upper and lower limbs with more affection in the lower limbs, and it was absent in 7 patients in upper and lower limbs, and in 13 patients in lower limbs only. Also there is a significant reduction in the amplitude of SSR in both control and diabetic groups on standing from supine position. Lastly, we conclude that the electrophysiological assessment of the peripheral nerve is essential for the diagnosis of the peripheral neuropathy which often accompanied with diabetes mellitus. Also we found that the abnormal SSR indicates the early affection of small unmyelinated c fibers in case of diabetic neuropathy. Also, we found that the sympathetic nerve fibers are significantly affected by changing body posture from supine to standing position.

تضمنت هذه الدراسة تسعة وثلاثين من مرضى السكري بنوعيه معتمد الأنسولين وغير معتمد الأنسولين، وأربعاً وثلاثين شخصاً صحيحاً متوافقين عمراً وجنساً مع مرضى السكري في محاولة لتوضيح تأثير التغير في وضع الجسم على الإستجابة السمبثاوية للجلد باستخدام جهاز تخطيط الأعصاب والعضلات. يتم تقييم الخلل الوظيفي في العصب المحيطي بواسطة الفحص السريري والإختبار الكهروفسلجي للأعصاب المحيطية التلقائية والجسمية الحسية في وضع الإستلقاء والوقوف. الإستجابات السمبثاوية التي تستثار بواسطة التحفيز الكهربائي للعصب الأوسط الأيمن والأيسر والعصب الشضوي المشترك الأيمن والأيسر، تم تسجيلها وتحليلها في وضع الوقوف والإستلقاء. إختبار الإستجابات السمبثاوية للجلد لمرضى السكري أوضحت إنخفاضاً ذا مغزى في الكمون والقمة للإستجابات السمبثاوية للجلد في الأطراف العليا والسفلى، مع تأثير أكبر في الأطراف السفلى، وكان مفقوداً في سبعة مرضى في الأطراف العليا والسفلى، وفي ثلاثة عشر مريضاً في الأطراف السفلى فقط. كذلك كان هناك إنخفاض ذا مغزى في القمة في الإستجابات السمبثاوية للجلد في كلا المجموعتين من مرضى السكري والأصحاء في وضعي الأستلقاء والوقوف. أخيراً، نستنتج بأن التقييم الكهروفسلجي لوظيفة الأعصاب المحيطية ضروري جداً لتشخيص اعتلال الأعصاب المحيطية الذي غالباً ما يترافق مع داء السكري، كذلك وجدنا بأن استجابة الجلد السمبثاوية غير الطبيعية تشير إلى التأثر المبكر للألياف العصبية الصغيرة نوع ج غير المغطاة بالنخاعين في حال إعتلال الأعصاب المحيطية المرافق للسكري. كذلك وجدنا بأن الألياف العصبية السمبثاوية تتأثر تأثراً ذا مغزى بتغير وضع الجسم من الإستلقاء إلى الوقوف.

Keywords


Article
Evaluation of Sysmex Automated Hematological Analyzer (KX-21N) for the measurement of Blood Hemoglobin Level

Author: Yesar M.H.Al-Shamma MBChB.,PhD.(UK).
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2012 Volume: 15 Issue: 1 Pages: 1-5
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Abstract: This study was carried out on twenty normal subjects (women) in order to evaluate (Sysmex Automated Hematological Analyzer KX-21N) for the estimation of blood hemoglobin level. Two processes where used for evaluation, the first is the systematic error to determine the accuracy of the device by comparison with the standard device (the Sahli's) and the second process is to test the random error or reproducibility of Sysmex. The result of this study indicate that values of Hb measured by Sysmex KX-21N were slightly higher than that measured by Sahli's method (P<0.005) And the result of random error test indicates that the Sysmex KX-21N is reproducible device which is improved by using the statically equation: (2SD/mean x 100%) to determine 95% tolerance limit of the device which indicate that the device is greatly reproducible.

أجريت هذه الدراسة على عشرين شخصا من الأصحاء لغرض تقييم جهاز فحص نسبة الهيموغلوبين في الدم Sysmex KX-21N)) وذلك بإتباع طريقتين: أولا مقارنته بطريقة Sahli)) والتي تعتبر الطريقة القياسية في قياس مستوى الهيموغلوبين لمعرفة مدى دقة الجهاز المراد تقييمه. ثانيا لمعرفة دقة الجهاز أثناء القياسات المتكررة و التي أظهرت نتائجها بان القياسات المتتالية للجهاز متقاربة جدا في القيمة و لغرض البرهنة على دقة الجهاز استعملت المعادلة الإحصائية: (2SD/mean x 100%)والتي تؤكد على أن جهاز يعطي قراءات دقيقة ويمكن استعماله في البحوث الطبية والمستشفيات الغرض منه قياس مستوى الهيموغلوبين في الدم عند الأصحاء وعند المرضى.

Keywords


Article
Evaluation of spirolabII spirometer for the assessment of lung function test.

Author: Yesar M.H.Al-shamma MBChB.,PhD.(UK).
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2009 Volume: 12 Issue: 2 Pages: 118-123
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

This study was carried out on twenty normal subjects in order to evaluate (SpirolabII spirometer)for the estimation of lung function test.Two processes where used for evaluation, the first is the systematic error to determine the accuracy of the device by comparison with the most accurate standard device (the vitalograph) and the second process is to test the random error or reproducibility of spirolabII. The result of this study indicate that there were no significant differences in values of FEV1, FVC and FEV% measured by spirolabII with that measured by vitalograph.More over the result of random error test indicate that the spirolabII is reproducible device which is proved by using the statistical equation (2SD/mean x100%) to determine 95% tolerance limit of the device which indicate that the device is greatly reproducible.

أجريت هذه الدراسة على عشرين شخصاً من الأصحاء لغرض تقييم جهاز قياس كفاءة الرئتين (spirolabII ) وذلك بإتباع طريقتين:أولاً مقارنته بجهاز أل( (vitalograph والذي يعتبر الجهاز المثالي بالدقة في قياس كفاءة الرئتين لمعرفة مدى دقة الجهاز المراد تقييمه.ثانياً لمعرفة دقة الجهاز أثناء القياسات المتكررة والتي أظهرت نتائجها بان القياسات المتتالية للجهاز متقاربة جداً في ألقيمه ولغرض البرهنة على دقة الجهاز استعملت ألمعادله الاحصائيه: 2SD/mean x100%والتي تؤكد على أن جهاز (spirolabII) يعطي قراءات دقيقه ويمكن استعماله في البحوث الطبية والمستشفيات لغرض قياس كفاءة الرئتين عند الأصحاء وعند المرضى المصابين بالربو القصبي.

Keywords


Article
Changes in Lung Function Tests in Patients with Bronchial Asthma in Response to 60 Degree Upright Tilting.

Author: *-Yesar M.H.Al-shamma MBChB.,PhD.(UK).
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2010 Volume: 13 Issue: 1 Pages: 6-20
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

This study was carried out to investigate the effect of 60° upright tilting on lung function test in patients with bronchial asthma.A-Effect of changing of posture to 60°upright tilting on normal (control) subjects indicates that the FVC, FEV1&PEFR were significantly higher in 60°upright tilting than that of supine values and no significant difference in FEV1%, and the differences between supine and 60°upright tilting values of FVC, FEV1&PEFR were significantly higher in asthmatic patients with no significant change in FEV1%.B- Effect of changing of posture to 60°upright tilting on all the asthmatic patients indicates that the FVC, FEV1&PEFR were significantly higher in 60°upright tilting than that of supine values, while there was no significant changes in FEV1 %.C- The effect of changing of posture to 60°upright tilting in both age groups i.e. group1(20-39year) and group2 (40-60year) indicates that there was significant increase in FVC, FEV1 and PEFR in 60°upright tilting with no significant change in FEV1%.On comparison between group1 &group2 in supine & 60°upright tilting FVC, FEV1& FEV1% were significantly higher in group1 than group2 but no significant difference was found in PEFR between group1& group2 in both supine and 60°upright tilting.D-The difference between the normal control subjects in this study and that of predicted values in both male and female of FVC, FEV1, and PEFR indicate that the predicted value in both male and female is slightly higher than that of the control values.

أجريت هذه الدراسة لبيان تأثير تغيير وضع جسم الإنسان من وضع الاستلقاء إلى الوضع المائل (٦٠درجه) على وظائف الرئتين(FEV1, FVC و (FEV1 (السعة الحيوية القسرية و الحجم ألزفيري ألقسري في الثانية الأولى والنسبة المئوية للحجم ألزفيري ألقسري في الثانية الأولى إلى السعة الحيوية القسرية ) لمرضى الربو القصبي.أ - مقارنه بين الأصحاء والمصابين بالربو القصبي بسبب تغيير وضع جسم الإنسان إلى الوضع المائل بدرجه ٦٠ °. أظهرت النتائج وجود انخفاض معنوي لكل من( (FVC,FEV1,PEFRبسبب تغير وضع جسم الإنسان للوضع المائل بدرجه ٦٠ °عن المرضى المصابين بالربو القصبي ولا يوجد فرق معنوي في( .(FEV1% ب- أظهرت النتائج أن هناك زيادة معنوية في وظائف الرئتين((FVC,FEV1,PEFR بينما لا توجد زيادة معنوية في (FEV1% ) عند تغيير وضع جسم الإنسان للوضع المائل بدرجه ٦٠ °عند جميع مرضى الربو القصبي.د-الفرق بين القيمة التقديرية والقيمة المحسوبة لمجموعة السيطرة, أظهرت النتائج أن هناك زيادة معنوية في القيمة التقديرية لوظائف الرئتين((FVC, FEV1, PEFR عن القيمة المحسوبة لمجموعة السيطرة.

Keywords


Article
Evaluation of APEL Digital Hemoglobin meter (HG-202) for the Measurement of Blood Hemoglobin Level.

Author: *-Yesar M.H.Al-shamma MBChB.,PhD.(UK).
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2010 Volume: 13 Issue: 2 Pages: 1-6
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Abstract:This study was carried out on thirty normal subjects in order to evaluate (Apel Hemoglobin meter HG-202) for the estimation of blood hemoglobin level.Two processes where used for evaluation, the first is the systematic error to determine the accuracy of the device by comparison with the standard device (the Sahli's) and the second process is to test the random error or reproducibility of Apel. The results of this study indicate that values of Hb measured by Apel HG-202 were slightly higher than that measured by Sahli's method (p<0.005)And the result of random error test indicate that the Apel HG-202is reproducible device which is proved by using the statistical equation (2SD/mean x100%) to determine 95% tolerance limit of the device which indicate that the device is greatly reproducible.

أجريت هذه الدراسة على ثلاثين شخصاً من الأصحاء لغرض تقييم جهازفحص نسبة الهيموغلوبين في الدم((Apel HG-202 وذلك بإتباع طريقتين:أولاً مقارنته بطريقة ((Sahli والتي تعتبر الطريقة القياسية في قياس مستوى الهيموغلوبين لمعرفة مدى دقة الجهاز المراد تقييمه.ثانياً لمعرفة دقة الجهاز أثناء القياسات المتكررة والتي أظهرت نتائجها بان القياسات المتتالية للجهاز متقاربة جداً في ألقيمه ولغرض البرهنة على دقة الجهاز استعملت ألمعادله الاحصائيه: 2SD/mean x100% والتي تؤكد على أن جهاز (HG-202 Apel) يعطي قراءات دقيقه ويمكن استعماله في البحوث الطبية والمستشفيات لغرض قياس مستوى الهيموغلوبين في الدم عند الأصحاء وعند المرضى.

Keywords


Article
A Non Invasive Evaluation Of Variability Of Intrarenal Blood Flow At Rest And During Exercise

Author: Akeel A.M. Hassan Zwain MBChB, (PhD UK)
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2008 Volume: 11 Issue: 1 Pages: 366-383
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Under normal conditions, renal blood flow is controlled by intrinsic factors and factors include an auto regulatory mechanism, intrarenal renin-angiotensin mechanism and kinins. The critical extrinsic factors include the sympathetic nervous system (SNS) angiotensin II, dopamine, nitric oxide. ADH and ANP. These multiple factors work in concert to sustain renal blood flow and glomerular filtration regardless of wide variations in systemic arterial B.P. This investigation is devoted to assess the variability of intrarenal arterial blood flow at different regions of the kidney at rest and during dynamic exercise. The available Studies on this subject are few, conflicting and are adopting static exercise. The study is conducted on 10 male healthy individuals of age ranging between 18-30 years. The interlobar intrarenal arteries spectral parameters (PSV,MDV, RI, and VTI) at upper pole, mid pole and lower pole are obtained at rest in supine and upright positions and during performing supine exercise. A color Doppler U/S Siemens versa plus equipment with 2.5 MHz phased array probe or 3.5 MHz convex probe and a bicycle ergometer(E 315) to perform supine exercise were utilized for this purpose. It was shown that: 1-The over all intrarenal blood flow is significantly higher in supine position than that in upright position. 2-The intrarenal blood flow at mid pole is significantly higher than that of lower and upper poles. 3-There is no significant difference of intrarenal blood flow between the upper and lower poles. 4-There is significant decrease of over all intrarenal arterial blood flow during dynamic exercise; it is mainly the diastolic flow which is decreased. It was concluded that this technique would afford an indirect approach to study the renal artery blood flow. Further, this study would help to stand as a valuable method to assess renal perfusion. More over, it stands as an indirect method to assess renal artery stenosis before and after surgical revascularization.

خلال الظروف الطبيعية, من المعلوم أن هنالك عوامل عدة تقوم بتنظيم إنسيابية الدم في شرايين الكلية الداخلية بصورة مستقرة: منها عوامل ذاتية تلقائيه تتعلق بالنسيج العضلي التكويني الخاص في الشرايين الداخلية وعوامل إنزيمية أو هرمونية مثل هرمون الرنين والانجيوتنسين والكاينين, بالإضافة إلى عومل خارجية مهمة تتعلق بتحفز الجهاز العصبي السمبثاوي المجهز لهذه الشرايين...هذه الدراسة خصصت لمعرفة التغيرات في إنسيابية الدم في شرايين الكلية الداخلية في أجزاء مختلفة من الكلية أثناء حدوث تغيير في وضع الجسم من حالة الاستلقاء إلى حالة الوقوف أو أثناء بذل مجهود عضلي كممارسة الرياضة مثلا. لقد تمت دراسة هذه التغيرات بالإستعانة بجهاز الدوبلر الملون، وهذه طريقة غير مباشرة ليس فيها أي أذى لجسم الإنسان. أجري هذا البحث على عشرة أشخاص أصحاء، وإن النتائج التي شوهدت كما يلي: أولاَ: حدوث زيادة ملموسة في كمية انسيابية الدم في شرايين الكلية الداخلية عندما يكون وضع الجسم في حالة الإستلقاء ونقصان ملموس عند تغيير الوضع إلى حالة الوقوف. ثانياً: حدوث زيادة في كمية انسيابية الدم في الشريان الموجود في حوض الكلية أكثر من الشرايين المجهزه للأجزاء العليا أو السفلى للكلية. ثالثاً: أنَ هناك ٌقلَة ملموسة في كمية انسيابية الدم في جميع شرايين الكلية الداخلية أثناء حدوث الإجهاد العضلي، كممارسة الرياضه مثلاً.

Keywords


Article
Possible Association of HLA-DR and DQ Molecules with Autoimmune Hepatitis in Iraqi Patients

Authors: Raghad J H AL-Akayshi --- MBChB, PhD --- Eman Sh. AL-Obeidy
Journal: Journal of the Faculty of Medicine مجلة كلية الطب ISSN: 00419419 / 24108057 Year: 2010 Volume: 52 Issue: 1 Pages: 49-52
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Human leukocyte antigen (HLA) is the most polymorphic genetic system in man. The genes of this region seem to influence susceptibility to certain diseases.
Patients and methods: Polymerase chain reaction-Sequence Specific Primers PCR-SSP is the method used to asses HLA-typing of 100 blood samples of 60 AIH patients and 40 healthy normal controls.
Results: An increased frequency of HLA-DR3, DR4 and DR7 was observed for patients group versus control group with P-value (0.0001, 0.05, and 0.001) respectively, while DR*0211 (DR2) may be formed the basis for protection against the disease. HLA-DQ on the other hand, yielded on association in Iraqi patients with AIH.
Conclusions: This finding demonstrated that HLA-DR3, DR4 and DR7 might play a role in AIH susceptibility.
Key words: autoimmune hepatitis, Human leukocyte antigen (HLA), PCR –SSP assay.

References:

Keywords

Listing 1 - 10 of 14 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (14)


Language

English (12)

Arabic and English (2)


Year
From To Submit

2016 (2)

2015 (1)

2012 (2)

2010 (3)

2009 (3)

More...