research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Phytoplankton Diversity and Pollution Index in North Part of Euphrates River, Iraq
تنوع الهائمات النباتية ومعامل التلوث في الجزء الشمالي من نهر الفرات– العراق

Authors: Huda A. Ali هدى عبدالله علي --- Mahmood M. Al-Mahdawi محمود مصطفى المهداوي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 3B Pages: 2223-2236
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study covered approximately 150 km from the northern part of the Euphrates River in Iraq. Water and phytoplankton samples were monthly collected from six selected stations from April 2013 to March 2014; three stations were distributed within Hadithah Reservoir, while the three others were in the river's inflow. Water physical and chemical parameters and the phytoplankton community structure were analyzed. The most important results of this study were the diagnoses of 355 phytoplankton species belong to eight phylums. Algal class Bacillariophyceae which belong to phylum Ochrophyta was the most qualitative and quantitative dominant in all stations over the study period. The stations within the reservoir were characterized by higher number of genes and species, which led to higher Shannon-Weaver diversity index values in comparison to other stations. Water quality were evaluated by using the mentioned diversity index and Palmer's pollution index, stations 1 which is located in the river before the reservoir were with low levels of pollution; stations 2, 3 and 4, which are located inside the reservoir and station 5 (downstream the reservoir) were likely polluted, while the organic pollution in station 6 was confirmed because it's location close to the sewage discharge. The study concludes that Palmer's pollution index was more accurate than diversity index for the evaluation of water pollution levels.

شملت الدراسة ما يقارب 150 كم من الجزء الشمالي لنهر الفرات في العراق, حيث جمعت عينات المياه والهائمات النباتية شهرياً من ستة محطات مختارة بدءاً بشهر نيسان 2013 ولغاية آذار 2014, وزعت المحطات بواقع ثلاث محطات في مجرى النهر وثلاثة أخرى ضمن خزان حديثة. تم دراسة العوامل الفيزيائية والكيميائية وكذلك تركيب مجتمع الهائمات النباتية في تلك المحطات. ومن أهم نتائج هذه الدراسة هي تشخيص 355 نوعاً من الهائمات النباتية تعود إلى ثمانية طوائف, كان لشعبة الطحالب العصوية Bacillariophyceae التي تعود إلى طائفة الـ Ochrophyta السيادة المطلقة كماً ونوعاً في جميع المحطات وطيلة فترة الدراسة. اتسمت المحطات داخل الخزان أرتفاعاً ملحوظاً في عدد الأنواع والأجناس مما أدى إلى ارتفاع قيم معامل شانون- ويفر للتنوعShannon–Weaver Diversity Indexفيها مقارنة بالمحطات الأخرى. صنفت مياه المحطات وفق معامل التنوع المذكور وكذلك معامل بالمر للتلوثPollution Palmer'sIndex, وكانت مياه المحطة1 التي تقع في مجرى النهر قبل دخوله الخزان ذات مستويات متدنية للتلوث, أما المحطات 2 و 3 و 4 التي تقع داخل الخزان فكانت مياهها من المحتمل أن تكون ملوثة وكذلك المحطة 5, بينما المحطة 6 فأن تلوثها العضوي كان مؤكداً لموقعها القريب من مصدر الصرف الصحي, كما وتؤكد ذلك الفروق المعنوية للعوامل الفيزيائية والكيميائية المدروسة في تلك المحطة مقارنة مع المحطات الأخرى. ومن خلال نتائج هذه الدراسة يمكن الاستنتاج بأن معامل بالمر للتلوث هو الأدق في تقييم مستويات التلوث مقارنة بمعامل التنوع.


Article
Evaluation of The Bacterial Content Removal and Treatment of Some Chemical Parameters in Waters of Tigris River and Wells in Baghdad City By Using Home Water Treatment System
تقييم ازالة المحتوى البكتيري ومعالجة بعض العوامل الكيميائية لمياه نهر دجلة والابار في مدينة بغداد باستخدام المنظومة المنزلية لمعالجة المياه

Authors: Doaa D. Salman دعاء داود سلمان --- Mahmood M. Al-Mahdawi محمود مصطفى المهداوي
Journal: Journal of university of Anbar for Pure science مجلة جامعة الانبار للعلوم الصرفة ISSN: ISSN: 19918941 Year: 2016 Volume: 10 Issue: 2 Pages: 56-62
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

This study was conducted to assess the efficiency of home water treatment system for removing bacterial content and reducing concentrations of some chemical agents (calcium, magnesium, sulfate and chlorides) by treating samples of river water and well water. Results Bacteriological tests showed that the system highly efficient in removing bacterial content after it exceeded the standard value of total number of aerobic bacteria in the Iraqi water quality standard and the World Health Organization (WHO) for drinking water quality, which reached before treatment 21x105 and 16x105 (cellml) in both waters samples of river and wells, respectively.The results showed high efficiency of the system for reducing the concentrations of calcium, sulfates and chlorides in both of river and wells waters, which made them identical with the Iraqi and WHO standards in exception of the sulfate concentration in the wells water, which remained higher than the Iraqi standards. The study indicate that the concentration of magnesium has decreased significantly after treatment in both waters, but it remained higher than Iraqi and WHO standards, while in wells it exceeded the Iraqi standards only.The results of the statistical tests indicate a significant effect of treatment on reducing the concentrations of calcium and sulfate in both raw waters, while it had no significant effects on reducing concentration of magnesium in river water and chlorides concentration in wells water.

اجريت هذه الدراسة لتقييم دور المنظومة المنزلية لمعالجة المياه في أزالة المحتوى البكتيري وخفض تراكيز بعض العوامل الكيميائية (الكالسيوم, المغنيسيوم, الكبريتات والكلوريدات) من خلال معالجة عينات من مياه النهر ومياه الابار. أظهرت نتائج الفحوصات البكتيرية ان للمنظومة كفاءة عالية في ازالة المحتوى البكتيري بعد ان تجاوز العدد الكلي للبكتريا الهوائية القييم المعيارية في المواصفات العراقية وتلك لمنظمة الصحة العالمية (WHO) لنوعية مياه الشرب والتي بلغت قبل المعالجة21 X 105 و 16 X 105 (خليةمل) في كل من عينات مياه نهر دجلة ومياه الآبار على التوالي. كما واظهرت النتائج كفاءة عالية للمنظومة في خفض تراكيز كل من الكالسيوم والكبريتات والكلوريدات لمياه النهر والآبار وجعلتها متوافقة مع المواصفات القياسية العراقية والعالمية باستثناء تركيز الكبريتات في مياه الآبار و الذي بقى غير متوافقاً مع المواصفات العراقية. وأوضحت الدراسة بأن تركيز المغنيسيوم في مياه النهر والآبار قد انخفض بعد المعالجة, الا ان تركيزه في مياه النهر بقية متجاوزة المواصفات العراقية والعالمية بينما تجاوز تركيزه في مياه الأبار المواصفات العراقية فقط. واظهرت نتائج التحليل الاحصائي ان للمعالجة تأثير معنوي في خفض تراكيز الكالسيوم والكبريتات في مياه النهر والآبار ولم يكن لها تأثير معنوي في خفض تركيز المغنيسيوم في مياه النهر والكلوريدات في مياه الآبار.


Article
ESTIMATION OF SOME CHEMICAL AND PHYSICAL PROPERTIES USING A WATER TREATMENT UNIT VORTISAND COMPARED TO THEIR CONCENTRATION IN WATER PRODUCED BY TRIDINTINAL DRINKING WATER PROJECTS IN BAGHDAD.
تقدير بعض الخصائص الكيميائية والفيزيائية باستخدام وحدة معالجة المياه الدوامات القسرية بالمقارنة مع تركيزها في المياه التي تنتجها مشاريع المياه الصالحة للشرب التقليدية في بغداد

Loading...
Loading...
Abstract

This study was conducted to determine the ability of water treatment system (Vortisand) to reduce some chemical and physical properties for tigris river raw water, It consisted of turbidity, electrical conductivity, pH, total hardness, calcium Hardness as well as temperature in order to determine the unit`s efficiency for reducing their concentration as compared to those in the water produced by some classical potable water projects (Dora and Wathba) in Baghdad. Samples were collected during the cold months (December 2016 and January 2017) and during the hot months (May and June 2017). The results showed that this system has the ability to reduce some properties such as turbidity, the values were 215NTU in raw water and decreased to NTU 2.8 during the cold months and NTU343.3 was reduced to NTU 125 during the hot months while it has no significant effect in reducing some properties such as total hardness of 503-513.3 mg/ L in produced water and calcium ranged from 131.3-160.5 mg/ L during the cold and hot months, respectively, and the properties in produced water fall within the permissible limits of potable water according to the Iraqi and international water quality standards.

أجريت هذه الدراسة لتحديد قدرة منظومة معالجة المياه (Vortisand) في التقليل من بعض الخصائص الكيميائية والفيزيائية في مياه نهر دجلة الخام، وتمثلت بالكدرة والايصالية الكهربائية والرقم الهيدروجيني والعسرة الكلية وعسرة الكالسيوم فضلا عن درجة الحرارة، وقد تمت دراسة كفاءة النظام بمقارنة مكونات التراكيز في المياه الخام مع تلك الموجودة في المياه المنتجة للنظام وكذلك مع تراكيزها في المياه الخام والمنتجة في كل من مشروعي الدورة والوثبة لمعالجة المياه في اشارة الى العراق والمعايير الدولية لنوعية المياه، وتم جمع العينات خلال الأشهر الباردة (كانون الأول 2016 وكانون الثاني 2017) وخلال الأشهر الحارة (أيار وحزيران 2017)، وبينت النتائج أن هذه المنظومة لها قدرة على خفض بعض الخصائص كالكدرة، اذ كانت قيمها 215NTU في المياه الخام وانخفضت الى NTU 2.8 خلال الاشهر الباردة وكانت NTU343.3 وانخفضت الى NTU 125 خلال الاشهر الحارة في حين لم يكن لها تأثير كبير في تقليل من بعض الخصائص كالعسرة الكلية، أذ كانت تتراوح من 513-503.3 ملغم/ لتر في المياه المنتجة والكالسيوم تراوحت تراكيزهُ من 160.5-131.3 ملغم/ لتر خلال الاشهر الباردة والحارة على التوالي، وأن بعض القيم تقع ضمن الحدود المسموح بها من مياه الشرب.


Article
The relationship between genotype using BOX-PCR technique and lead bioremoval by Klebsiella pneumoniae
العلاقة بين النمط الوراثي باستعمال تقنية BOX-PCR والازالة الحياتية للرصاص بوساطة بكتريا Klebsiella pneumoniae .

Loading...
Loading...
Abstract

The effect of metabolic status on lead bioremoval byKlebsiella pneumoniae were tested. The results revealed a significant differences (P<0.05) between live and dead (killed by heat) cellsas the bioremoval reached 57.0 ± 3.4 and 21.6 ± 2.5, respectively.Bioremoved lead ions were recovered (P<0.05) using three different washing solutions, 0.1M EDTA was the most efficient since it recovered about 63.9 ± 5.6 mg/ml, while Na2CO3 was able to recover 35.9 ± 2.6 mg/ml; whereas 0.1M HCl recovered 21.8 ± 2.6 mg/ml. genomic DNA was extracted from different isolates of K. pneumoniae in order to study the relationship between genotype using BOX-PCR and bioremoval of lead. Three clusters were detected C1, C2, and C3 with similarity percentages reached 52, 60, and 100%. What's more, bioremoval did not depend on particular genotype

اختبرت الحالة الايضية لبكتريا K. pneumoniae و تأثيرها في الازالة الحياتية للرصاص حيث بينت النتائج وجود فروق معنوية عالية عند مستوى احتمالية p ≤ 0.05 بين الخلايا الحية والخلايا المقتولة بالحرارة ,حيث كانت نسبة الازالة الحياتية للخلايا الحية (57.0 ±3.4) ملغم / لتر/ساعة , بينما للخلايا الميتة (21.6 ± 2.5) ملغم / لتر. امكن اعادة ايونات الرصاص الممتزة باستعمال عدة محاليل غسل , كان محلول (0.1M EDTA) الاكفاء اذ تم استرجاع (63.9 ± 5.6) ملغم /لتر/ساعة , وتمكن محلول (Na2CO3) من استرجاع (35.9 ± 2.6) ملغم /لتر / ساعة , أما محلول 0.1 M (HCL) فقد استرجع (21.8 ± 2.6) ملغم /لتر /ساعة . بينت النتائج وجود فروق معنوية عالية عند مستوى احتمالية p ≤ 0.05 بين محاليل الغسل. تم استخلاص الدنا الجينومى للعزلات البكتيرية. كما تم اجراء تجربة لمعرفة العلاقة بين التنميط الوراثى والازالة الحياتية بطريقة البصمة الوراثية BOX – PCR و بينت النتائج ظهور ثلاث انماط وراثية وبنسبة تشابه 53 % وهى C1 وC2 وC3 فكانت نسبة التشابه للمجموعه الاولى 52 % والثانية 60 % والثالثة 100 % . أن نسبة الإزالة الحياتية لم تعتمد على نمط وراثى معين.


Article
Efficiency of bacteria isolated from Al-Ramadi General Hospital sewage in bioabsorption of lead
كفاءة البكتريا المعزولة من مياه الصرف الصحي لمستشفى الرمادي العام في امتزاز الرصاص

Loading...
Loading...
Abstract

The present study involved collection of 30 Al-Ramady General Hospital sewage, five samples for each 15 days from the treatment unit for the period October 2014 to February 2015 in triplicates. Six bacterial isolates were identified: Aeromonashydrophila, Aeromonassobria, Escherichia coli, Klebsiella pneumonae, Staphlyococcushominis and Staphylococcus aureus. All these isolates were tested for their ability to remove lead from its aqueous solutions. Significant differences (P< 0.05) were found among bioremoval capacity which were as follows 11.3 ± 5.5, 11.8 ± 5.4, 14 ± 10, 62.2 ± 28.9, 19.6 ± 2.2 and 12.3 ± 7, respectively. However, K. pneumoniae achieved the highest removal capacity. Results revealed a variable minimum inhibition concentration (MIC) of lead among the tested isolates. Furthermore, K. pneumoniae showed the highest MIC reached 3200 mg/ml; whereas, A. sobriadeveloped the lowest MIC reached 500 mg/ml. upon FTIR analysis, hydroxyl, amide, carboxyl and amine were the active sites for lead binding.

تضمنت الدراسة الحالية جمع 30 عينه من مياه الصرف الصحي لمستشفى الرمادي التعليمي , وبواقع خمس عينات مياه كل خمسة عشر يوما , وموزعة بالتساوي على وحدة المعالجة لمياه الصرف الصحي , خلال المدة الممتدة من تشرين الاول 2014 لغاية منتصف شباط 2015 وبواقع ثلاث مكررات لكل عينة .تم عزل وتشخيص (6) عزلات بكتيرية من مياه الصرف الصحي لوحدة المعالجة لمستشفى الرمادي التعليمي Aeromonas hydrophila و Aeromonas sobriaوEscherichia coli وKlebsiella pneumoniae Staphylococcus homonisوStaphylococcus aureus .اختبرت العزلات في قابليتها على إزالة الرصاص من المحاليل المائية وأظهرت فروقا معنوية عالية عند مستوى احتمالية p ≤ 0.05 وقـد كانت سعـة الإزالة 11.3 ± 5.5)) و( 11.8 ±5.4) و(14.0 ± 10.0) و(62.2 ± 28.9)و( 19.6 ± 2.2) و(12.3 ± 7.0),ملغم/لتر/ساعة على التتابع . تم تحديد العزلة ذات الكفاءة العالية في عملية الإزالة الحياتية وكانت العزلة البكتيرية K.pneumoniae. أظهرت نتائج قياس التركيز المثبط الأدنى تباين العزلات البكتيرية في مدى تحملها لتركيز الرصاص , إذ أظهرت العزلة K.pneumoniae مدى تحمل بلغ 3200 ملغم / مل , بينما أظهرت العزلة A. sobria اقل مدى لتحمل الرصاص بلغ 500 ملغم / مل .تباينت مديات التحمل للعزلات المختلفه لبكتريا K.pneumoniae المعزولة من بيئات مختلفة إذ تراوحت بين 3100- 3800 ملغم / مل . من نتائج تحليل الأشعة تحت الحمراء تبين أن المواقع الفعالة لربط ايونات الرصاص الهيدروكسيل , والامايد , والكاربوكسيل , والأمين .

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

Arabic (5)


Year
From To Submit

2018 (1)

2016 (1)

2015 (3)