research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Numerical Analysis of Piled Raft Foundation on Clayey Soil
التحليل العددي للأساس الحصيري المدعم بالركائز في التربة الطينية

Authors: Hussein H. Karim --- Mahmoud R. AL-Qaissy --- Mudhafar K. Hameedi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 7 Part (A) Engineering Pages: 1297-1312
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The piled raft foundations allow an increase in the load capacity and reduction of settlements in a very economic way as compared with the traditional foundation concepts. Due to the development of structures that use piled rafts as a foundation system, an extensive numerical modeling study was performed considering different factors and conditions. This study highlights the percentage ratio of bearing loads between the pile and the pile cap (raft). Present modeling results obtained by computer program (Plaxis 3D Foundation V 1.1) have been verified with an experimental work of the same problem using the same configuration but extended to include 8 and 16 piles with raft for different soil layers. In addition, a comparison of the present results is achieved with another a theoretical study using the program (Ansys). The finite element method through Plaxis program evaluates the effect of parameter on the load-settlement behavior of the piled raft foundation. The effect of spacing between piles on the load-settlement behavior of the piled raft foundation was also studied. The percentage of the load carried by piles to the total applied load of the numerical model for case sixteen piles with raft is around 42%. The contribution to carry the load of piles relative to the total load is decrease with the increase of the spacing to diameter ratio. The percentage of the load carrying for piled raft for the case of two piles with raft only decreases about 23% when the spacing between piles increases from 3 to 10 times pile diameters.

ان الأسس الحصيرية المدعمة بالركائز تسمح بزيادة التحمل و تقليل الهطول وبشكل اقتصادي بالمقارنة مع مجاميع الأسس التقليدية. ونتيجة التطور الحاصل في التراكيب المستخدمة للأسس الحصيرية المدعمة بالركائز, أجريت هذه الدراسة النمذجية أخذين بنظر الاعتبار عوامل وظروف مختلفة. تسلط الدراسة الحالية الضوء على النسبة المئوية للتحمل ما بين الركيزة والأساس. تم التحقق من نتائج النمذجة الحالية المستحصل عليها باستخدام برنامج (PLAXIS 3D Foundation V 1.1) من خلال مقارنتها مع عمل مختبري يعالج نفس المشكلة وبنفس الترتيب وتم حل النموذج مع اضافة حالتين هما 8 و 16 ركيزة مع الأساس و لطبقات تربة مختلفة. وبالإضافة إلى ذلك، تم إجراء مقارنة اخرى بين النتائج الحالية مع دراسة نظرية باستخدام برنامج (ANSYS). تهدف البرامج التي تعتمد طريقة العناصر المحددة من خلال برنامج (PLAXIS)الى تقييم تأثيرسلوك علاقة الحمل- الهطول للأسس الحصيرية المدعمة بالركائز. كما درس تأثير المسافة بين الركائز على هذه العلاقة. وجدت النسبة المؤية لقابلية تحمل الركائز الى الحمل الكلي في النموذج النظري لحالة ستة عشر ركيزة مع الاساس هي بحدود 42 %. وتبين من الدراسة أن مقدار مساهمة الركائز في قابلية التحمل الكلية تقل بزيادة المسافة بين الركائز. وقد وجد في حالة ركيزيتين مع الأساس الحصيري تقل قابلية التحمل بمقدار 23 % مع زيادة المسافة بين الركائز من ثلاثة أضعاف الى عشرة أضعاف قطر الركيزة.


Article
Differentiating Clayey Soil Layers from Electrical Resistivity Imaging (ERI) and Induced Polarization (IP)
تمییز طبقات التربة الطینیة من المقاومة النوعیة الكھربائیة (ERI) التصویریة (IP) والاستقطاب المستحث

Authors: Nadia A. Aziz --- Mahmoud R. AL- Qaissy --- Hussein H. Karim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 17 Part (A) Engineering Pages: 3216-3234
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electrical Resistivity Imaging (ERI) method is one of the most promisingtechniques which is well suited for the applications in the fields of geohydrology,environmental science and engineering. The present work is aimed to show theefficiency of 2D Electrical Resistivity Imaging (ERI) and Induced Polarization (IP) inprobing the subsurface soil for site investigation and differentiating the clayey soillayers as it is a common practice to measure the IP sounding along with resistivity forcorrect interpretation of field data. The study has demonstrated the practicalapplication of 2D ERI and IP tomography along 7 lines using Wenner- Schlumbergerarray. The data analysis comprises of 2D inversions using the RES2DINV software,thus 2D electrical resistivity and IP imaging sections have been obtained. The depth ofinvestigation was 4 m, and resistivity values range from <1 to 292 ohm.m. Twoelectrical layers were recognized: the upper layer with high resistivity (7-71 ohm.m)represents the loamy soil extends to a depth around 1.3 m; and the second layer withlow resistivity (<1-9 ohm.m) represents the clayey layer. Some anomalous low andhigh electric zones are appeared reflecting the inhomogeneity in deposits. The IPvalues are ranging from -2 to 17 mV/V showing good confirmation with resistivitydata, where high chargeability are associated with low resistivity. The study revealsthat combining IP with resistivity surveys is recommended since IP is, sometimes, veryeffective in relieving ambiguity in interpretation.


Article
2D and 3D Resistivity Imaging for Soil Site Investigation
المقاومة النوعیة التصویریة ثنائیة وثلاثیة الأبعاد للتحري الموقعي للتربة

Authors: Hussein H. Karim --- Mahmoud R. AL- Qaissy --- Nadia A. Aziz
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 1 Part (A) Engineering Pages: 249-272
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electrical Resistivity Imaging (ERI) method is one of the most promisingtechniques which is well suited to applications in the fields of geohydrology,environmental science and engineering. The present work is aimed to show the efficiency of 2D Electrical Resistivity Imaging (ERI) and Induced Polarization (IP) in probing the subsurface soil for site investigation and differentiating the clayey soil layers as it is a common practice to measure the IP sounding along with resistivity forcorrect interpretation of field data. The study has demonstrated the practical application of 2D ERI and IP tomography along 7 lines using Wenner- Schlumberger array. The data analysis comprises of 2D inversions using the RES2DINV software, thus 2D electrical resistivity and IP imaging sections have been obtained. The depth of investigation was 4 m, and resistivity values range from <1 to 292 ohm.m. Two electrical layers were recognized: the upper layer with high resistivity (7-71 ohm.m)represents the loamy soil extends to a depth around 1.3 m; and the second layer with low resistivity (<1-9 ohm.m) represents the clayey layer. Some anomalous low and high electric zones are appeared reflecting the inhomogeneity in deposits. The IP values are ranging from -2 to 15 mV/V showing good confirmation with resistivity data, where high chargeability are associated with low resistivity. The study reveals that combining IP with resistivity surveys is recommended since IP is, sometimes, very effective in relieving ambiguity in interpretation.


Article
Studying Soil Undrained Shear strength Due to Driving Piles Using Seismic Cross-Hole Technique
دراسة مقاومة القص غيرالمبزول للتربة نتيجة ركائز الدق باستخدام تقنية الابار المتقاطعة الزلزالية

Authors: Hussein H. Karim --- Mahmoud R. AL-Qaissy --- Wisam Rahi Hasan
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 10 Part (A) Engineering Pages: 2408-2428
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The study is intended for geotechnical engineers who deal with the construction of deep foundations using driving piles with the implementation of seismic cross-hole technique to estimate the accompanying increase (or decrease) in soil shear strength. The study concluded that there is a direct relation between the increases in soil undrained shear strength with yield stress ratio and reverse relation with moisture water content and void ratio. The increase in undrained shear strength is observed in the clay soil layer at 3-5 m in depth with low moisture content and void ratio due to the effect of time. While at depth of 1-3 m, the reverse was noticed, this decrease is attributed to the upward displacement of the soil due to shear force from driven pile and then leading to increase the soil moisture content and void ratio. The study also concluded that an increase in undrained shear strength and yield stress ratio causing a decrease in void ratio and moisture content due to the effect of aging factor. The present results have provided good overall views of the shear strength increases and their distributions and the estimated values are also of the right sizes.

ان هذه الدراسة موجهة الى مهندسي الجيوتكنيك الذين يتعاملون مع انشاء الأساسات العميقة باستخدام ركائز الدق من خلال تنفيذ تقنية الابار المتقاطعة الزلزالية لتقدير الزيادة (أو النقصان) المصاحبة لمقاومة قص التربة. خلصت الدراسة الى ان هنالك علاقة طردية بين زيادات مقاومة القص غيرالمبزول للتربة مع نسبة إجهاد الخضوع وعكسية مع محتوى ماء الرطوبة و نسبة الفراغات. لوحظت زيادة مقاومة القص غيرالمبزول في طبقة التربة الطينية في العمق 3-5 متر مع انخفاض محتوى الرطوبة و نسبة الفراغات بسبب تأثير الزمن. بينما في العمق 1-3 م، لوحظ العكس ويعزى هذا النقصان الى ازاحة التربة للاعلى بسبب قوى القص الناتجة من طرق الركيزة و والتي أدت الى زيادة المحتوى المائي ونسبة الفراغات في التربة. كما خلصت الدراسة إلى أنه أي زيادة في مقاومة القص غيرالمبزول ونسبة إجهاد الخضوع تسبب انخفاض في نسبة الفراغات ومحتوى الرطوبة بسبب تأثيرعامل العمر. وفرت النتائج الحالية نظرة جيدة عموما في زيادات مقاومة القص وتوزيعاتها والقيم المقدرة لها بنسب معقولة.


Article
Three-Dimensional Dynamic Analysis of Pile Foundations by Using Finite Element Method
التحليل الحركي الثلاثي الأبعاد لأسس الركائز بإستخدام طريقةِ العناصرِ المحدودة

Authors: Saad Faik Abbas Al-Wakel --- Mahmoud R. Al-Qaissy --- Ahmed Sameer Abdulrasool
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 5 Part (A) Engineering Pages: 1038-1048
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In recent years, there is a dramatic progress in the development of theories for dynamic analysis of piles. The finite element method is a numerical approximation procedure to analyze physical problems by transforming them into mathematical models. This needs to be done numerically because it is either too complicated or impossible to solve problems by classical analytical methods.In this study, a three- dimensional analysisby using finite element method will be adopted to predict the displacement response of pile foundation due to dynamic loads. A case study is carried out to investigate the effect of particles size of soil, length of pile, spacing between piles andpile cap size on the dynamic response of pile foundations. The results indicate that, the maximum amplitude of displacement of pile foundation under dynamic loads can be occurred in loose sand in comparison with the other types of sand. In addition, the increase in pile length will lead to decrease in the amplitude of displacement due to increases in the mass of the foundation.

في السَنَوات الأخيرة، هناك تقدّم كبير في تطوير النظرياتِ للتحليل الحركي للركائز. إنّ طريقةَ العناصرِ المحدودةِ إجراء تقريبِ عدديِ لتَحليل المشاكلِ الفيزيائية بتَحويلها إلى النماذج الرياضية. هذا يعني مَنْ الضَّرُوري أَنْ يكون الحل بشكل عددي لأنه أمّا أن يكون معقّد أَو مستحيل جداً لحَلّ المشاكلِ بالطرقِ التحليليةِ الكلاسيكيةِ.في هذه الدراسةِ، التحليلِ الثلاثي الابعاد باستخدامُ طريقةَ العناصرِ المحدودةِ سَيتبنّى لتَوَقُّع رَدِّ الإزاحةَ لأسس الركائز بسبب ألأحمالِ الديناميكيةِ. حيث سيتم دراسة حالة للتَحرّي عن تأثيرِ حجم حبيبات التربةِ، طول الركيزة، المسافة بين الركائز، حجم قبعة الركائزعلى الرَدِّ الديناميِكي لأسس الركائز.تُشيرُ النَتائِجُ بأنّ، السعة القصوى لإزاحةِ أسس الركائز تحت الأحمالِ الديناميةِ يُمْكِنُ أَنْ تُحدث في الرملِ الرخو بالمقارنة بالأنواعِ الأخرى للرملِ. بالإضافة، الزيادة في طولِ الركيزة سَتُؤدّي إلى النقصانِ في سعة الإزاحةِ بسبب الزيادة في كتلةِ الركيزة.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (5)


Year
From To Submit

2015 (1)

2014 (2)

2013 (2)