Article
ASSESSMENT OF POWER SYSTEM TRANSIENT STABILITY BY RKE METHOD

Author: Majli Nema Hawas AL-Kazraji
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2008 Volume: 21 Issue: 1 Pages: 14-22
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

The criterion for assessment is given in terms of the rate of change of kinetic energy of individual machines subsequent to fault clearance. The basic concepts and the mathematical formulation of the method are summarized. Practical test system is used to demonstrate the superior efficiency of the method relative to step by step given in the literature. Comparison of results between stability prediction of the step by step method and the RKE method shows good agreement.The importance of this development may be judged by the saving it can make in the calculation of power system stability for large system.

أن معيار الحكم على استقرارية منظومة القدرة يعتمد على حساب معدل تغير الطاقة الحركية في لحظة إزالة العطل, تم تلخيص التمثيل الرياضي البسيط والمفصل للماكنة حسب الحاجة.تم اعتماد نماذج اختبارية تطبيقية معتمدة في الأدبيات لعرض مزايا الطريقة مع طريقة الخطوة خطوة, من مقارنة النتائج لاحظنا أن هناك تقارب كبير بين نتائج الطريقتين.يمكن استخدام طريقة معدل تغير الطاقة للحكم على استقرارية منظومات قدرة كبيرة من دون صعوبات أو تعقيدات قد تجعل الحل غير ممكن في بعض الأحيان أو يستغرق زمناً طويلاً كما يحصل في طريقة الخطوة- خطوة الكلاسيكية.

Keywords


Article
Transient Voltage Stability Enhancement Using Fuzzy Logic Controller Techniques *

Authors: Dr. Majli Nema Hawas ** --- Abdullah Yaseen Abbas **
Journal: IRAQI JOURNAL OF COMPUTERS,COMMUNICATION AND CONTROL & SYSTEMS ENGINEERING المجلة العراقية لهندسة الحاسبات والاتصالات والسيطرة والنظم ISSN: 18119212 Year: 2012 Volume: 12 Issue: 2 Pages: 16-27
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Abstract: This paper discusses the transient voltage stability of a synchronous generator at its bus in a power system with a detailed transient modeling for the generator after being subjected to a three phase fault, and designing a Takagi-Sugeno first order fuzzy logic controller with center of area defuzzification algorithm as a fuzzy logic controller based exciter to stabilize the terminal voltage and to damp its oscillations so as to keep the generator under balanced working conditions. The proposed exciter can be easily modified by changing the steady state field voltage value to be applied to any other synchronous generator. This paper also used the integral of square error as an indicator of the terminal voltage stability and monitored all of the generator variables specially the rotor angle to see whether the generator will maintain synchronism or not after the occurrence of the fault.


Article
Comparison between Using FLC and Auto-Tuning FLC in Synchronous Generator Transient Voltage Stability Enhancement
مقارنة بين استخدام متحكم المنطق الضبابي وبين متحكم المنطق الضبابي تلقائي التنغيم لتحسين استقرارية الجهد العابر لمولد متزامن

Authors: Majli Nema Hawas --- Abdullah Yaseen Abbas
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 8 Part (A) Engineering Pages: 1474-1482
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper compares between responses of Fuzzy Logic Controller (FLC) based exciter and auto-tuning FLC based exciter. Both of the exciters are simulated separately with synchronous generator connected to infinite bus through a short transmission line. The systems where subjected to three phase fault at the infinite bus, maximum Integral of Square Error (ISE) of generator terminal voltage response and critical clearing time were taken as performance indices of the exciters. The systems then studied under normal operating condition to justify the need of auto-tuning.

هذه الورقة تقارن بين أستجابة محفز معتمد على مسيطر ضبابي وإستجابة محفز معتمد على مسيطر ضبابي ذاتي التنغيم. تم محاكاة كل محفز على حده للسيطرة على الجهد الطرفي العابر للمولد تزامني متصل بعمومي لانهائي خلال خط نقل قصير. أخضع النظام الى إضطراب ثلاثي الطور على العمومي اللانهائي. أستخدم تكامل مربع الخطأ لاستجابة الفولتية الطرفية للمولد وزمن الإزالة الحرج كدلائل لمعرفة الإداء للمحفزات في ظروف العمل المضطربة وتم إثبات الحاجة الى التنغيم الذاتي في ظروف العمل الطبيعية.


Article
Simulation of Power System Stability Using Lyapunov's Direct Method.
محاكاة استقرارية منظومة قدرة باستخدام طريقة ليبونوف المباشرة

Author: MAJLI NEMA HAWAS AL-KHAZRAJI مجلي نعمة حواس الخزرجي
Journal: Journal of Research Diyala humanity مجلة ديالى للبحوث الانسانية ISSN: 1998104x Year: 2008 Issue: 27 Pages: 64-74
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

This paper presents a brief description of Lyapunov's direct method, and demonstrates its efficiency with respect to previous indirect step by step method, in order to compute the stbility of electromechaincal power system. The practical advantages of this direct method of analysis are:(i)Rapid solution.(ii)Ability to compute the degree of stability.The limitations that Lyapunov's direct method suffers from:a)Severe modeling limitations.b)If the system is unstable, the analysis does not indicate how it separates and whether the separated parts survive of collapse. The basic concepts and the mathematical formulation of the method are summarized. Practical test system are used to demonstrate the superior efficiency of the method relative to step by step method.

يعرض البحث وصف مختصر لطريقة ليبونوف المباشرة وتعرض كفائتها مقارنة بطريقة الخطوة – خطوة غير المباشرة من اجل حساب الأستقرارية لمنظومة قدرة كهروميكانيية, والفوائد العملية لهذه الطريقة التحليليه:أ‌.سرعة الحل.ب‌.امكانية حساب درجة الاستقراريه وتعاني هذه الطريقة من الاتي:1.محدوديةالنمذجة.2.في حالة عدم استقرار المنظومة لايمكن تحديد الماكنه او مجموع المكائن الخارجة عن الاستقرار.تم تلخيص المفاهيم الاساسيه والتمثيل الرياضي. وتم اعتماد منظومة اختباريه لعرض كفاءة طريقة ليبنوف المباشرة مقارنة مع كفاءة طريقة الخطوة – خطوة غير المباشرة.

Keywords


Article
A Comparative Study of Power System Transient Stability Parameters Calculation
دراسة مقارنة لحساب معلم الأستقرارية العابرة لمنظومة القدرة

Authors: MAJLI NEMA HAWAS مجلي نعمة حواس --- FADIL MUHAMMED KALAF فاضل محمد خلف --- ARWA AMER ABDUL-KAREEM أروى عامر عبد الكريم
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2010 Issue: 16 Pages: 269-290
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

The power system transient stability studies depend on the state of sudden disturbance to which the system is subjected, such as the fault state on the system. The increasing size of modren power systems requires fast and more efficient methods of solutions. Therefore the classical approach of repeated integrations will be length and time consuming. Investigations to overcome this difficulty led to the use of direct methods. These mothods use the energy balance in the system. Two different direct methods are investigated in this work to provide a comparative study with the Indirect Integration method. The first is the rate of change of kinetic energy method. The critical fault clearance time in this method corresponds to the machine. In which the RACKE has the largest negative value at this time. The second direct method is the extended equal area criterion. In this method the multi-machine system is composed of two subsets: one consists of the critical machines; the other comprises the remaining system. Each group is reduced to a single machine, and then the two-machine equivalents were reduced to a single machine to infinite bus system. Then the equal area criterion is applied to determine the Critical Clearing Time and Transient Stability Margin (TSM). As a result, the RACKE method has closer Critical Clearing Time and Transient Stability Margin to the Indirect Integration method although the EEAC method is faster than the RACKE method. The application of these methods on four; five and twelve machine power systems is presented. The programs that were used in this work are implemented by using (MATLAB).

تتركز دراسة الاستقرارية العابرة في منظومات القدرة الكهربائية على حالات الاضطراب المفاجئ التي تتعرض لها المنظومة على سبيل المثال حالات العطل التي تحدث في المنظومة. تم اعتماد الطرق غير المباشرة والطرق المباشرة لحساب زمن الإزالة الحرج للمنظومات في الطرق غير المباشر (الخطوة - خطوة) , تتضمن تكرار تكامل المعادلات التفاضلية للمنظومة على طول الزمن اللازم لحالة المنظومة خلال العطل وبعده , ويعاد هذا الحل لكل زمن إزالة عطل. ان هذه الطريقة وبالرغم من دقة نتائجها تستغر ق زمن حسابي كبير وهذا لا يتناسب مع تطور المنظومة الكهربائية. لذا فأن الدراسات المستمرة وجدت طرق سريعة وكفوءه لحساب الإزالة الحرج دون اللجوء الى الاعتماد على منحنيات المتغيرات المختلفة للمنظومة لتحديد زمن الازالة الحرج وهي الطرق المباشرة التي تتجاوز الصعوبات المذكورة اعلاه وان هذه الطرق تعتمد على معيار التوازن في الطاقة. تم اعتماد طريقتان في البحث لغرض مقارنتها مع الطريقة غير المباشرة. الطريقة الأولى هي طريقة معدل تغير الطاقة الحركية. الزمن الحرج لازالة العطل يكون طبقاً للماكنة ذات معدل تغير الطاقة الحركية الأكثر سالبيه. والطريقة الثانية هي طريقة تساوي المساحات المتوسعة ان هذه الطريقة تعتمد على تحويل المنظومة الى مجموعتين حيث تمثل المجموعة الاولى المكائن الحرجة والمجموعة الثانية تمثل باقي المكائن, وتحول المجموعتين الى ماكينتين مكافئتين ثم تحول إلى ماكنة مكافئة مربوطة الى القظيب إللامتناهي وتطبق بعد ذلك على المنظومة المبسطة طريقة تساوي المساحات المعروفة. تم التوصل في هذا البحث الى ان طريقة معدل تغير الطاقة الحركية تحقق قيم ادق من طريقة تساوي المساحات المتوسعة ووجد ان القيم التي توصلت لها طريقة معدل تغير الطاقة الحركية اقرب الى حد ما من القيم التي توصلت اليها الطريقة غير المباشرة على الرغم من ان طريقة تساوي المساحات المتوسعة تكون اسرع من طريقة معدل تغير الطاقة الحركية. ولقد تم اختيار ثلاثة منظومات تحققت من خلالها هذه النتائج وهي كما يلي :1-المنظومة الاولى ذات اربعة مكائن وستة عقد وسبعة خطوط . 2-المنظومة الثانية ذات خمسة مكائن واثناعشر عقده وخمسة عشر خط. 3-المنظومة الثالثة ذات اثنا عشرة ماكنة وتسعة عشر عقدة وثلاثة وثلاثون خط تم تنفيذ العمل باستخدام البرمجيات المتوفرة في المختبر الرياضي (MATLAB) وقورنت النتائج المستحصلة.


Article
THE APPLICATION OF PROGRAMMING FAST METHOD FOR CALCULATION THE CRITICAL CLEARING TIME IN TRANSIENT STABILITY ANALYSIS OF IRAQ SUPER GRID
تطبيق طريقة برمجية سريعة لحساب وقت الازالة الحرج في تحليل الاستقرارية العابرة لشبكة الجهد الفائق العراقية

Authors: Majli Nema Hawas مجلي نعمة حواس --- Maitham Ali Naji ميثم علي ناجي --- Arwa Amer Abdul Kareem أروى عامر عبد الكريم
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2014 Volume: 27 Issue: 4 Pages: E1-E21
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

A transmission line trip during a power swing may cause instability of a power system. It is necessary to recognize the power swing from fault based on stability boundary, the power swing blocking relays must be set to do that, power swing should be analyzed, a way of probability of occurrence of fault must be found, the critical condition under which the stability of a power system hasn’t been disturbed is recognized & finally the settings of the power swing relays are calculated. The main aim of this paper is to reduce the execution time of the process of finding of the Critical Clearing Time (CCT) using Programming Fast Method (PFM) and compare it with Bisection Method. In practice however, calculating the CCT is computationally inefficient and not desirable because the Bisection method is a tedious and inefficient process. A proposed method for finding the CCT of the power system at any direct fault or indirect-fault is more efficient method in the accuracy & solution time to calculate (CCT) in transient stability analysis. The results obtain by Bisection and proposed methods show that the proposed method reduce the execution time of the CPU about 8-10 times.In this paper the CCT was calculated for two power systems (single machine and the Iraq Super Grid at 10 locations in the Iraqi transmission line network) by using Bisection & proposed methods.MATLAB version 7 is used to implement several programs for the optimal execution time of the CPU time, with using PC4 and CPU speed 3 GHz.

في نظام القدرة الكهربائية اي قطع او عطل في منظومة القدرة خلال تارجح الماكنة قد يسبب حالة عدم استقرار في نظام القدرة لذلك يكون من الضروري تمييز نظام القدرة خلال حدوث العطل ويتم ذلك عن طريق اجهزة حماية هذه الانظمة لايجاد طريقة افتراضية لحدوث العطل وتحديد الظروف الحرجة لأستقرارية منظومة القدرة وحسابات تارجح النظام.ان الهدف الرئيسي من هذا البحث هو تقليل زمن الانجاز الازم لايجاد زمن الازالة الحرج في وحدة المعالجة المركزية بواسطة طريقة البرمجة السريعة ومقارنتها بطريقة التنصيف. عمليا ,تكون طريقة التنصيف غير مرغوب فيها وتكون غير فعالة وشاقة جدا اما الطريقة المقترحة في عملية ايجاد زمن الازالة الحرج عند اي عطل مباشر او غير مباشر فوجد انها اكثر فاعلية من ناحية الدقة وزمن الحل لتقييم استقرارية القدرة.تشير النتائج المستحصلة بالطريقتين الى تفوق الطريقة المقترحة على طريقة تنصيف الزمن. حيث وجد انها تقلل زمن الانجاز في وحدة المعالجة المركزية بمقدار يتراوح بين 8 – 10 مرات. في هذا البحث تم حساب زمن الازالة الحرج لمنظومتين اختباريتين (الماكنة الاحادية و10 موقع لشبكة الجهد الفائق العراقية) بواسطة تطبيق طريقة التنصيف والطريقة المقترحة وذلك باستخدام برنامج الماتلاب (اصدار 7) وحاسبة بانتيوم 4 وسرعة المعالج 3 ميغا هيرتز.