research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
New Approach for The Turbidimetric Determination of Iron(III) in Drug Samples of Different Origins Using Homemade Linear Array Ayah 5SX1-T-1D-CFI Analyser
نمط جديد لقياس التعكرية لتقدير الحديد(III) في مناشئ مختلفة من العينات الدوائية باستخدام المحلل الحقن الجرياني المستمر Linear Array Ayah 5SX1-T-1D-CFI Analyser المصنوع محلياً

Authors: Issam M.A. Shakir عصام محمد علي شاكر الهاشمي --- Mohammad K. Hammood محمد كاظم حمود
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 3A Pages: 852-864
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A new Turbidimetric method characterized by simplicity, accuracy and speed for determination of iron(III) in drug samples by continuous flow injection analysis. The method was based on the formation of complex for iron(III) with 8-hydroxyquinoline in presence of ammonium acetate as a medium for the formation of deep green precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.6 mL.min-1 flow rate using H2O as a carrier, 1.9 mL.min-1 (14 mmol.L-1) ammonium acetate, 2.4 mL.min-1 (14 mmol.L-1) 8-hydroxyquinoline, 60 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.1-8.0 mmol.L-1 while L.O.D 4.8×10-9 M/sample equivalent to 16.1 pg/sample from the stepwise dilution for minimum concentration of lowest concentration in linear dynamic range of the calibration graph. The correlation coefficient (r) was 0.9911 while percentage linearity (%r2) C.O.D was 98.24%. R.S.D.% for the repeatability (n=6) was <1% for determination of iron(III) with concentration 4 and 8 mmol.L-1. The method was applied successfully for the determination of iron(III) in pharmaceutical preparations. Using paired t-test between the newly developed method and official method; shows that there were no significant differences between either methods. On this basis the new method can be accepted as an alternative analytical method for determination of iron(III) in pharmaceutical samples.

استحدثت طريقة بسيطة وسريعة ودقيقة لتقدير الحديد(III) في المستحضرات الصيدلانية من خلال اقتران الحقن الجرياني المستمر مع قياس التعكرية. تستند الطريقة على تكوين راسب بين ايون الحديد(III) والكاشف 8-هيدروكسي كوينولين بوجود خلات الامونيوم كوسط، اذ ينتج راسب اخضر غامق، قدر الراسب المتكون باستخدام جهاز Linear Array Ayah 5SX1-T-1D-Continuous Flow Injection Analyser المصنوع محلياً. درست الظروف الفضلى للتفاعل، اذ استخدم 2.6 مل.دقيقة-1 كسرعة جريان للتيار ناقل H2O، 1.9 مل.دقيقة-1 (14 مللي مول.لتر-1) كتيار لخلات الامونيوم، 2.4 مل.دقيقة-1 (14 مللي مول.لتر-1) 8-هيدروكسي كوينولين، واستخدم 60 مايكرولتر كحجم لانموذج المحقن مع ترك صمام الحقن مفتوح لخروج مقطع الانموذج. بينت معالجة البيانات المستحصلة المدى الخطي لتقدير الحديد(III) 0.1-8 مللي مول.لتر-1 بينما حدود الكشف 4.8×10-9 مول.لتر-1 والمكافئ الى 16.1 بيكوغرام من التخفيف التدريجي لاقل تركيز في منحني المعايرة. معامل الارتباط (r) 0.9911 والنسبة المئوية للخطية هي 98.24% والانحراف القياسي النسبي المئوي (n=6) اقل من 1% لتركيزين 4 و8 مللي مول.لتر-1 لمحلول الحديد(III). طبقت الطريقة لتقدير الحديد(III) في المستحضرات الدوائية. استخدام اختبار t-المزدوج لاجراء مقارنة بين الطريقة المستحدثة والطريقة القياسية، وجد انه لا يوجد فرق جوهري بين الطريقتين وبذلك يمكن استخدام الطريقة المستحدثة كطريقة بديلة لتقدير الحديد(III) في النماذج الدوائية.


Article
New Developed Data Treatments for the Characteristic Linear Array Ayah 5SX1-T-1D-CFI Analyser Segment Response Profile & Generalization
معالج بيانات جديد ومتطور لمعالجة هيئة الإشارات المسجلة من جهاز Linear Array Ayah 5SX1-T-1D-CFI Analyser

Authors: Issam M.A. Shakir عصام محمد علي شاكر الهاشمي --- Mohammad K. Hammood محمد كاظم حمود
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4A Pages: 1431-1454
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Derivative spectrophotometry is one of the analytical chemistry techniques used in the analysis and determination of chemicals and pharmaceuticals. This method is characterized by simplicity, sensitivity and speed. Derivative of Spectra conducted in several ways, including optical, electronic and mathematical. This operation usually be done within spectrophotometer. The paper is based on form of a new program. The program construction is written in Visual Basic language within Microsoft Excel. The program is able to transform the first, second, third and fourth derivatives of data and the return of these derivatives to zero order (normal plot). The program was applied on experimental (trial) and reals values of sulphate determination in the form of barium sulphate by a Linear Array Ayah 5SX1-T-1D-CFI Analyser. The data was collected through an Array M3500A 6.5Digit Digital Multimeter linked between the spectrometer and computer

تُعد المشتقات الطيفية من التقنيات المستخدمة في الكيمياء التحليلية في تحليل وتقدير المواد الكيميائية والدوائية. اذ تتصف هذه الطريقة بالبساطة والحساسية والسرعة في التقدير. وتجرى المشتقات الطيفية بطرائق عدة منها الضوئية والالكترونية والحسابية وعادة تكون ضمن جهار المطيافية المستخدم. يعتمد البحث على بناء برنامج مكتوب بلغة الفجوال بيسك ضمن برنامج الاكسل يقوم باشتقاق البيانات كمشقة أولى وثانية وثالثة ورابعة وارجاع هذه المشتقات الطيفية الى المشتقة الصفرية. تم تطبيق البرنامج على قيم تجربيبة وأخرى حقيقة عند تقدير الكبريتات على هيئة كبريتات الباريوم باستعمال جهاز (Linear Array Ayah 5SX1-T-1D-CFI Analyser) وتم جمع البيانات من خلال جهاز(Array M3500A 6.5Digit Digital Multimeter) الرابط بين المطياف والحاسوب الالكتروني.


Article
Two Techniques (Spectrophotometric and Turbidimetric) for Determination of Ciprofloxacin HCl in Pharmaceutical Drugs with Comparison between the Techniques
تقنيتان لتقدير الدواء السايبروفلوكسسين هيدروكلورايد (طيفية وتعكرية) في المستحضرات الصيدلانية واجراء مقارنة بين التقنيتين

Authors: Mohammad K. Hammood محمد كاظم حمود --- Jalal N. Jeber جلال ناصر جبر --- Yasmeen H. Muhamad ياسمين حكمت محمد
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 3A Pages: 1620-1628
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A new, effective, simple and inexpensive method was developed for determination the amounts of Ciprofloxacin HCl in solutions and in tablets by spectrophotometry and turbidity using sodium tungstate as reagent. Also, in this paper comparison between two techniques was conducted. The reaction between the Ciprofloxacin HCl and reagent in acidic media formed a yellowish white complex. Chemical and physical conditions have been investigated. The Linear range for spectroscopic and turbidimetric techniques were (0.05-1.25) and (0.05-3.0) mmol.L-1 with correlation coefficients (0.9956) and (0.9941) respectively. The limits of detection were 7×10-5 and 5×10-5 mol.L-1. The proposed method is good alternative for determination of Ciprofloxacin HCl in tablets.

طورت طريقة جديدة لتقدير دواء السايبروفلوكسسن هيدروكلورايد في المحاليل القياسية وفي المستحضرات الصيدلانية من خلال استخدام تنكستات الصوديوم كعامل مرسب وقياس العكورة بتقنيتي المطيافية الضوئية والتعكرية. تتصف هذه الطريقة بالبساطة والحساسية والسرعة في التقدير. كذلك خلال هذا البحث تمت المقارنة بين التقنينتين. الطربقة تعتمد على تكوين مزدوج ايوني بين المادة الدوائية السايبروفلوكسسين والكاشف تنكستات الصوديوم بالوسط الحامضي اذ يتكون راسب ابيض مصفر. تم دراسة كافة المتغيرات الكيميائية والفيزيائية للتفاعل. كان المدى الخطي لتقدير الدواء السايبروفلوكسسين هيدروكلورايد (0.05-1.25) مللي مول.لتر-1 و (0.05-3.0) مللي مول.لتر-1 وبمعامل الارتباط (r) 0.9956 و0.8841 للقياسات الطيفية والتعكرية على التوالي. اما حد الكشف فقد كان 7×10-5 مول.لتر-1 للتقنية الطيفية و5×10-5 مول.لتر-1 للتقنية التعكرية. الطريقة المقترحة تعد طريقة بديلة لتقدير السايبروفلوكسسين في المستحضرات الدوائية.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (3)


Year
From To Submit

2016 (1)