research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Experimental prediction of pressure drop and friction coefficient of Gas –solid fluid flow in a circular tube
التنبؤ التجريبي لهبوط الضغط ومعامل الاحتكاك لجريان مائع غاز صلب في انبوب دائري

Author: Mohammed Fowzi Mohammed محمد فوزي محمد
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2011 Volume: 11 Issue: 1 Pages: 139-151
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Abstract:-This study explains the relationship between friction coefficient and pressure change at a range of Reynolds (21056 - 32033) and (0 -1.4) solid loading ratio of two phase flow (Gas-solid) inside a circular copper pipe of (63mm) inside diameter and (2m) length by using laboratory apparatus and solving the equations mathematically . An experimentally relationships of friction coefficient and pressure change with Reynolds number and flow velocity one obtained also the relationship between the solid loading ratio with friction coefficient and pressure change has been done for a limit range of Reynolds number . It is noticed that the increasing in friction coefficient and pressure change for two phase flow was occurred when solid loading ratio increasing. Also the relationship between pressure change and Reynolds number was direct proportion while the relationship between friction coefficient and Reynolds number were inversely related

الخلاصة: -يتناول هذا البحث دراسة تبين علاقة معامل الاحتكاك و الهبوط بالضغط باستخدام ارقام(1.4 - 32033 ) ولمقادير مختلفة لنسب تحميل الصلب ( 0 - رينولدز تتراوح مابين ( 21056(63mm) لجريان ثنائي الطور (غاز- صلب ) داخل انبوب دائري نحاسي بقطر داخلي2) . وذلك من خلال بناء جهاز مختبري وحل المعادلات الحاكمة رياضيا . ت م m) وبطولالحصول على العلاقات التجريبية بين معامل الاحتكاك والهبوط بالضغط مع عدد رينولدزوسرعة الجريان بالاضافة الى بيان علاقة نسبة التحميل مع معامل الاحتكاك والهبوط بالضغطلمدى معين من ارقام رينولدز.ومن اهم الاستنتاجات التي تم الحصول عليها هو حدوث زيادة في مق د ار معامل الاحتكاكوالهبوط بالضغط لجريان ثنائي الطور بزيادة نسبة تحميل الصلب . كما وجد ان العلاقة التيتربط هبوط الضغط مع عدد رينولدز هي علاقة طردية على عكس العلاقة التي تربط معاملالاحتكاك بعدد رينولدز حيث تكون علاقة عكسية .


Article
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
دراسة تجريبية للأداء الحراري لمصفوفة من المجمعات الشمسية المسطحة ذات اشكال ربط مختلفة

Authors: Jafar Mehdi Hassan جعفر مهدي حسن --- Qussai Jihad Abdul-Ghafour قصي جهاد عبد الغفور --- Mohammed Fowzi Mohammed محمد فوزي محمد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 5 Pages: 55-71
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at water flow rate (150) ℓ/ hr. It was also noted that the thermal stratification of storage tank in case of series connection is higher than that of parallel connection. Also, when the flow rate increases, the thermal stratification of storage tank reduces.

يوضح البحث الحالي تجريبيا تأثير ربط التوالي، وربط التوازي (شكلZ-I) لمصفوفة من المجمعات الشمسية المسطحة على الاداء الحراري لمنظومة تسخين بالطاقة الشمسية مغلقة الحلقة .تضمنت الدراسة تأثير تغير معدل التدفق على الكفاءة الحرارية. بينت النتائج العملية ان كفاءة المجمعات ذات ربط التوالي اعلى من ربط التوازي عند معدل التدفق اقل من 100 لتر/ ساعة . كما بينت التجارب العملية ان كفاءة المجمعات ذات ربط التوازي (شكل-I-) اعلى من (شكلZ--) عند زيادة معدل التدفق. ان الكفاءة القصوى لربط التوازي (شكلZ-I) خلال اليوم(55%) و(51%) عند معدل تدفق 150 لتر/ ساعة . كما لوحظ ان التدرج الحراري للخزان في حالة ربط التوالي اعلى من ربط التوازي . بالإضافة الى ان عند زيادة معدل التدفق تقلل من قيم التدرج الحراري للخزان .

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2015 (1)

2011 (1)