research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Implementation of Finite Element Method for Prediction of Soil Liquefaction Around Undergroud Structure
توظيف طريقة العناصر المحددة في تخمين تسييل التربة حول منشأ تحت الارض

Authors: Mohammed Y. Fatah --- Mohammed A. Al-Neami --- Nora Hameed Jajjawi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 4 Part (A) Engineering Pages: 703-714
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Liquefaction is the rapid loss of shear strength in cohesionless soils subjected to dynamic loading, that it is a state of saturated cohesionless soil when its entire shear strength is reduced to zero due to pore water pressure caused by vibration. Liquefaction depends on the nature, magnitude and type of dynamic loading. An entire stratum may be liquefied at the same time under shock loading, or liquefaction may start at the top and proceed downward with steady-state vibrations. In this paper, finite element method is used in an attempted to study liquefaction of soil based on the case solved previously by transient infinite element for 2D soil - structure interaction analysis considering infinite boundaries but without generation of pore water pressure. The properties of fully saturated sandy soil and concrete are fed to geotechnical finite element software called QUAKE/W program. The results showed that liquefaction occurs faster at shallow depths due to low overburden pressure. Also, liquefaction zones and deformation occur faster with the increase of dynamic loading amplitude. The analysis marked that increasing the amplitude pressure accelerates the occurrence of initial liquefaction and increases the pore water pressure.

يعرف التسييل بأنه الفقدان السريع في مقاومة القص للترب عديمة التماسك المعرضة الى حمل ديناميكي وهذا يعني انه حاله للتربة عديمة التماسك المشبعه عندما تنخفض مقاومتها للقص الى الصفر نتيجة ارتفاع ضغط ماء المسام الذي تسببه الاهتزازات. يعتمد التسييل بطبيعته على مقدار ونوع الحمل الديناميكي , ويمكن لطبقة التربه بكاملها ان تسييل في نفس الوقت عند تعرضها لحمل صدمه او يمكن ان يبدأ التسييل في قمة الطبقه ثم ينتقل الى اسفلها عند تعرضها الى اهتزازات منتظمه.في هذا البحث استعملت طريقة العناصر المحددة في محاولة لدراسة تسييل التربة بناءاً على مسألة محلولة سابقاً لتحليل ثنائي الابعاد للتداخل بين التربة والمنشأ بأستعمال العناصر اللامنتهية المنتقلة ((transient بدون تولد ضغط ماء المسام. وتم تغذية خواص التربه الرملية المشبعة والخرسانة الى برنامج حاسبة يستعمل لتحليل المسائل الجيوتكنيكية بطريقة العناصر المحدده يسمى QUAKE/W.لقد بينت النتائج أن التسييل يحدث اسرع في أعماق ضحلة نتيجة قلة ضغط تثقيل التربه وكذلك تحدث مناطق التسييل والتشوهات بشكل أسرع مع زيادة القيمة القصوى للحمل الديناميكي. وقد أشارت النتائج الى أن زيادة القيمة القصوى للضغط المسلط يعجل من حدوث التسييل الأولي ويزيد قيمة ضغط ماء المسام.


Article
Effect of Using Equivalent Driving Energy on Small Model Driven Pile Capacity
تأثير أستخدام طاقة الدق المكافئة على تحمل موديلات مصغرة من ركائز الدق

Authors: Kais Taha Shlash --- Mohammed A. Al- Neami --- Ahmed Majeed Ali
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 7 Part (A) Engineering Pages: 1229-1238
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Physical modeling is performed in order to study particular cases of the behavior of prototype and to validate theoretical and/or empirical hypotheses. However, most physical models will be constructed at much smaller scales than the prototype precisely because it is desired to obtain information about expected patterns of response more rapidly and with closer control over model details than would be possible with full-scale testing. The main problem associated with physical model tests is the stress levels and soil particle size effects. These points should be considered which require deep and thorough research when studying the behavior of small scale model piles in sand. The tests indicate that the number of blows recorded when driving the model pile is affected by pile diameter more than with pile length. As well as, the heavier hammer shows precedence in bearing capacity than the light hammer because it leads to upgrade the soil properties during pile driving.

النمذجة الفيزيائية تنجز لغرض دراسة الجوانب العملية لتصرف النموذج الأصلي ولتأييد الفرضيات النظرية او التجريبية. مع ذلك, أغلب النماذج الفيزيائية سوف تبنى بواسطة مقاييس أكثر صغراً˭ من النموذج الأصلي وبشكل دقيق لأنه مطلوب الحصول على معلومات عن أنماط أستجابة متوقعة بسرعة وبتحكم خلال تفاصيل النموذج على أن يكون ممكنا˭ مع فحص النموذج الكامل. المشكلة الرئيسية المصاحبة لنتائج الموديلات الفيزيائية هي تأثير مستويات الأجهاد وحجم حبيبات التربة. هذه النقاط يجب ان تؤخذ بنظرالأعتبار والتي تتطلب بحث عميق وشامل عند دراسة نماذج الركائز المصغرة في الرمل. الفحوصات تشير إلى إنه عدد الضربات المسجلة عند دق نموذج الركيزة يتأثر بالقطر أكثر من طول الركيزة. أيضا, تظهر المطرقة الأثقل أفضلية عن المطرقة الأخف في قابلية التحمل لأنها تؤدي إلى تحسين خواص التربة أثناء دق الركيزة.


Article
Soil Site Investigations Using 2D Resistivity Imaging Technique
تحریات التربة الموقعیة باستخدام تقنیة المقاومة النوعیة التصویریة ثنائیة الأبعاد

Authors: Hussein H. Karim --- Mohammed A. Al-Neami --- Wisam M. Y. Mohammad
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 16 Part (A) Engineering Pages: 3125-3146
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The use of 2D Electrical Resistivity Imaging (ERI) technique in combination withgeotechnical and geological data allow the determination of the lithologicalcomposition and detailed internal architecture of the subsurface and understanding thecharacterisation and description of the geology of the site. This study is aimed toevaluate the use of 2D ERI for the detection and characterisation of heterogeneities insubsurface soil. The survey was conducted using a Wenner-Schlumberger and Wennerconfigurations along thirteen ERI parallel profiles which have been investigated in theproject of Al-Obaidi Electrical Transformation Station site to find the resistivity anddepth of soil horizons with their lithological description. Analysis of imaging sectionsshows that Wenner-Schlumberger sections are with higher resolving power thanWenner sections in both horizontal and vertical variations in resistivity reflecting morepronounced soil horizons with depth, where Wenner sections are limited to the uppersoil layers. Resisitvity values in the imaging sections indicate that the stratigraphy ofthe study area is mostly of clayey soil. 4 to 7 distinct geoelectric layers generallyidentify the subsurface down to depth of about 20 m. High resistivity values in the topsoil, medium-high resistivity values representing the upper soil layers, while lowerreistivity values are indicated for the lowerest layers. The resistivity values areinversely proportional to many soil properties such as fine content (clay and silt), saltcontent (sulphate and gypsum content) for saturated conditions, water content,plasticity index (P.I) and void ratio particularly for saturated condition. The resistivityvalues are directly proportional to sand content, void ratio, salt contents for drycondition. The integrated use of ERI technique and conventional site investigation hasled to a far better understanding of the site than could have been achieved using siteinvestigation methods alone.


Article
Characteristics of 2-D Electrical Resistivity Imaging Survey for Soil
خصائصية المسح التصويري ثنائي الأبعاد للمقاومة النوعية الكهربائية للتربة

Authors: Hussein H. Karim --- . Imzahim Abdul Kareem Alwan --- Mohammed A. Al-Neami
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 19 Part (A) Engineering Pages: 70-89
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The present work is aimed to show the efficiency of 2-D Electrical Resistivity Imaging (ERI) in probing the subsurface soil for site investigation, in addition to highlight some capabilities and characteristics of the sections acquired by 2D-ERI survey. In the field survey, where the University of Technology site is chosen for such investigation, ERI technique has been used implementing three common arrangements (Wenner, Wenner-Sclumberger and dipole-dipole). Different resolving powers have been obtained for the used arrays. Wenner-Schlumberger array gives moderate number of possible measurements and has a median depth of investigation of about 10% larger than that for the Wenner array. It is moderately sensitive to both horizontal and vertical structures, thus it might be a good compromise between the Wenner and the dipole-dipole arrays. Good agreements have been obtained between the stratigraphic columns of the site with the inversion models using the different arrays. The distribution of resistivity of the inversion models for the study site reflects the highly inhomogeneous subsurface soil with a wide variation of soil resistivity at different depths.

يهدف العمل الحالي إلى إظهار كفاءة تقنية المقاومة النوعية الكهربائية التصويرية ثنائية الأبعاد (2D-ERI) في فحص التربة تحت السطحية للتحري الموقعي، بالإضافة إلى تسليط الضوء على بعض قدرات وخصائص المقاطع التصويرية التي تم الحصول عليها بواسطة المسح الكهربائي ثنائي الأبعاد ((2D-ERI. في المسح الحقلي, حيث أختير موقع الجامعة التكنولوجية لهذا التحري, حيث استخدمت تقنية (ERI) بتنفيذ ثلاثة ترتيبات شائعة (فنر و فنر-شلمبرجر وثنائي القطب-ثنائي القطب). تم الحصول على قوى تحليلية مختلفة باستخدام هذه الترتيبات.أعطى ترتيب فنر- شلمبرجر عدد معتدل من القياسات الممكنة وبمعدل عمق للتحري أكبر بحوالي 10٪ مما هو لترتيب فينر. كما انه حساس بدرجة متوسطة للتراكيب الأفقية والعمودية, وبالتالي قد يكون حلا وسطا جيدا بين ترتيبي فينر و ثنائي القطب- ثنائي القطب. تم الحصول على اتفاقات جيدة بين العمود الطباقي للموقع مع نماذج الانعكاس باستخدام الترتيبات المختلفة. عكس توزيع المقاومة من نماذج الانعكاس لموقع الدراسة التربة تحت السطحية غير المتجانسة للغاية مع تباين واسع للمقاومة النوعية للتربة في الأعماق المختلفة.


Article
Strength Improvement of Soft Soil Treated Using Stone Columns
تحسین مقاومة التربة الطینیة الضعیفة المعالجة بالاعمدة الحجریة

Authors: Mohammed Y. Fattah --- Mohammed A. Al-Neami --- Ahmed Shamel Al-Suhaily
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 8 Part (A) Engineering Pages: 1740-1756
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A total number of 12 models tests were carried out on models of soft clays of different values of undrained shear strength varying from 8 to 18 kPa. The tests consist of twelve models of stone columns, single column, two-column group, three-column group, four-column group, five-column group and six-column group, in addition to one model of untreated soil.The undrained shear strength has been measured using portable vane shear before testing and after failure of model. It was noticed that the undrained shear strength of model stone columns increased by about (5.6 -20) % due to the construction of stone columns. The provision of stone column in soft clay bed caused an increase in the bearing capacity of the foundation bed by (1.76 - 2.91) times for floating stone columns and (2.13 – 3.15) times for end bearing columns.

تم اجراء الأختبارات على اثني عشر موديلا لتربة طينية ضعيفة تتراوح قيمة مقاومة القص غير المبزول فيها بين ( 8- 18) كيلوباسكال وتتضمن الأختبارات عمود حجري واحد و عمودين و ثلاثة اعمدة و أربعة أعمدة و خمسة أعمدة وستة أعمدة بالأضافة الى موديل لأساس على تربة طينة ضعيفة فقط. تم قياس مقاومة القص غير المبزول بأستخدام جهاز فحص القص بالأرياش المختبري قبل الفحص وبعد حصول الفشل لكل موديل. و قد لوحظ بأن مقاومة القص غير المبزول تزداد بنسبة تتراوح بين (5.6 -20 ) % وذلك بسبب انشاء الأعمدة الحجرية وأن قابلية تحمل التربة تزداد بنسبة تتراوح بين ( 1.94 – 1.32 ) للأعمدة الحجرية الطافية وتزداد بنسبة ( 1.7 – 2.5 ) للأعمدة الحجرية ذات التحمل عند النهايات.


Article
Effect of Relative Density on Behavior of Single Pile and Piles Groups Embedded with Different Lengths in Sand

Authors: Falah. H. Rahil --- Mohammed. A. Al-Neami --- Kather Abdullah Naji Al-Zaho
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 6 Part (A) Engineering Pages: 1206-1220
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The present research investigates the effect of axial relative density on the ultimate load of model piles with different lengths driven in dry sandy soil having small scale model piles.The materials used in this study are divided into three parts they are; sandy soil, steel piles and aluminum pile caps.A total number of 27 model tests are carried out using three relative densities (33%, 60%, and 80%) corresponding to loose, medium and dense sand, respectively. A square section steel solid model piles are used with 18 mm width and (320, 420, 520) mm embedded length (Ld). A 6B distance between the piles center to center is selected to eliminate the effect of group interaction.Two pile groups' configuration (1×2) and (2 × 2) are considered in this study connected by aluminum caps with smooth surface having a thickness of 25 mm.The load applied on the models is measured by a pressure transducer connected to the main line of the hydraulic pressure system and applying up to failure. During all the experimental tests, the loading rate is kept at 3 mm/min. It was founded that relative density has more impact on (2×2) pile group than on (1×2) pile group and single pile. The average rate of increase in the ultimate load from loose to medium is about 15% greater than the average rate of increase from medium to dense. Also, the ultimate load of pile increased about 96% with changing the sand density from loose to medium sand for single and piles group while the average increment is about 81% from medium to dense. The increase in embedded length of pile caused increasing the ultimate load capacity and decreasing the settlement ratio. The average rate of increase in the ultimate load when the embeddedlength changes from 32 cm to 42 cm is about 4% less than the average rate of increase when the embedded length changes from 42 cm to 52 cm. Also, use of (1×2) piles group instead of a single pile, the average rate of increase is about 6% less than the average rate of increase when change from (1×2) group to (2×2) pile group.Finally, when the number of piles changes from single pile to (1×2) piles group, and to (2×2) piles group, the average of increase of ultimate load is about 102.5% and 108.5% respectively.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (6)


Year
From To Submit

2016 (1)

2015 (1)