research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
New Method for the Determination of DL-Histidine by FIA and Chemiluminometric Detection
طريقة جديدة لتقدير الهستادين بتقنية الحقن الجرياني المستمر والتحسسبالبريق الكيميائي

Authors: Nagam S. Turkey نغم شاكر تركي العوادي --- Issam M.A. Shakir عصام محمد علي شاكر الهاشمي
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2010 Volume: 7 Issue: 2 Pages: 927-938
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.

يقدم البحث طريقة بسيطة وحساسة لتقدير الهستادين باستخدام منظومة الحقن الجرياني من خلال قياس البريق الكيميائي الناتج من اكسدة اللومينال بفعل بيروكسيد الهيدروجين في وسط قاعدي بوجود الهستادين بحجم 70 مايكرولتر على التيار الناقل من هيدروكسيد الصوديوم والذي يعطي بريق ازرق-بنفسجي له قمة انبعاث عند 425 نانومتر. تم الحصول على علاقة لتغير استجابة البريق مع التركيز للهستادين باستخدام معادلة الخط المستقيم وكان مدى منحني المعايرة يمتد من (5-60) مللي مول.لتر-1 ومعامل التقدير 95.79% ومعادلة الدرجة الثانية بمدى من (5-80) مللي مول.لتر-1 ومعامل التقدير 96.44% ولوحظ ان الاخيرة اكثر واقعية في التعبير عن كافة النتائج. تم التوصل الى حدود كشف (S/N = 3) 31.93 مايكروغم/70 مايكرولتر من التخفيف التدريجي لاقل تركيز في منحني معادلة الخط المستقيم. تكرارية النتائج المستحصل عليها %RSD < 5% لست قياسات متكررة. تم دراسة تاثير الايونات الموجبة والسالبة حيث ازيل تاثيرها باستخدام اعمدة صغيرة جداً معبأة بمبادل ايوني موجب او سالب ومربوطة بعد صمام الحقن مباشرةٍ.


Article
Flow injection analysis for the photometric determination of promethazine-HCl in pure and pharmaceutical preparation via oxidation by persulphate using Ayah 3SX3-3D solar micro photometer
التحليل بالحقن الجرياني للتقدير الطيفي للبروميثازين-هيدروكلورايد في المستحضرات الصيدلانية والنقية من خلال الاكسدة باستخدام بيرسلفات الصوديوم ومنظومة Ayah 3SX3-3D solar الطيفية

Authors: Nagam S. Turkey نغم شاكر تركي --- Issam M. A. Shakir عصام محمد علي شاكر
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2013 Volume: 10 Issue: 4 Pages: 1190-1202
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The first flow injection spectrophotometric method is characterized by its speed and sensitivity which have been developed for the determination of promethazine-HCl in pure and pharmaceutical preparation. It is based on the in situ detection of colored cationic radicals formed via oxidation of the drug with sodium persulphate to pinkish-red species and the same species was determined by using homemade Ayah 3SX3-3D solar flow injection photometer. Optimum conditions were obtained by using the high intensive green light emitted diode as a source. Linear dynamic range for the absorbance versus promethazine-HCl concentration was 0-7 mmol.L-1, with the correlation coefficient (r) was 0.9904 while the percentage linearity (r2%) was 98.09%. the L.O.Q was 3.97 µg/sample, while L.O.D (S/N=3) = 0.2407µg/sample (5 µmol.L-1) from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic range of the calibration graph. The R.S.D% at 2 mmol.L-1 promethazine-HCl is less than 1% (eight replicates) using 150 µL sample volume. Throughput 30 sample.hr-1. The method was applied successfully for the determination of promethazine-HCl in pharmaceutical preparation. By using paired t-test it was shown that there was no significant difference between the proposed method and official method and on that basis the new method can be accepted as an alternative analytical method.

تم تطوير طريقة تحليلية طيفية سريعة وحساسة باستخدام تقنية الحقن الجرياني لتقدير بروميثازين – هيدروكلورايد في المستحضرات الصيدلانية والنقية. استندت الطريقة على التحسس الاني بالجذور الايونية الملونة والمتكونة من خلال اكسدة الدواء باستخدام بيرسلفات الصوديوم لتكوين اصناف بلون احمر – برمنغناتي وقياس الامتصاصية باستخدام منظومة مصنعة محلياً طيفية للتحليل بالحقن الجرياني المستمر Ayah 3SX3-3D solar FI photometer . تم دراسة الظروف المثلى باستخدام ثنائي الوصلة باعث للضوء الاخضر وبشدة عالية كمصدر للتشعيع. المدى الخطي الفعال لعلاقة تغير الممتصية مع التركيز للبروميثازين – هيدروكلورايد يمتد (0-7)مللي مول.لتر-1 وبمعامل ارتباط 0.9904 =r بينما نسبة الخطية 98.09 =%r2. حد التقدير الكمي (L.O.Q) 3.97 مكغم/انموذج بينما حدود الكشف (L.O.D) (S/N= 3) = 0.2407 مكغم /انموذج (5 مايكرومول.لتر-1) من التخفيف التدريجي لاقل تركيز في منحني المعايرة. الانحراف القياسي النسبي المئوي RSD% لتركيز 2 مللي مول.لتر-1 من البروميثازين – هيدروكلورايد اقل من 1% (تكرارية (8=n)) باستخدام حجم لانموذج محقن 150 مايكرولتر. معدل النمذجة = 30 انموذج/ساعة. طبقت الطريقة بنجاح لتقدير الدواء في المستحضرات الصيدلانية.باستخدام اختبار –tالمزدوج لوحظ انه لا يوجد فرق جوهري بين الطريقة المقترحة والطريقة القياسية، وعلى هذا الاساس بالامكان استخدام الطريقة المقترحة للتحليل بالحقن الجرياني الطيفي كبديل للطريقة القياسية.


Article
New Approach for an On-Line Turbidimetric Determination of Cadmium (II) in Different River Water Via the Use of A homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
نمط جديد لقياس التعكرية الأني لتقدير ايون الكادميوم في مختلف مياه الانهر من خلال محلل جديد مصنع محليا للحقن الجرياني المستمر Ayah 6SX1-T-2D Solar) ).

Authors: Nagam S.Turkey نغم شاكر تركي العوادي --- Omar A. Yassin عمر اياد ياسين
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4A Pages: 1402-1414
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly developed analytical method characterized by its speed and sensitivity for the determination of cadmium (II) in aqueous solution in three randomly chosen samples from river water at different locations via turbidimetric measurement by Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity was measured via the reflection of incident light that collides on the surfaces precipitated particles at 0-180o. Chemical and physical parameters were investigated. Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with correlation coefficient r = 0.9951. The limit of detection 25.29 ng/ sample from the step wise dilution for the minimum concentration in the linear dynamic range of the calibration graph with RSD % lower than 1.5% for 8 mmol.L-1 (n=5) concentration of cadmium (II). The method was applied successfully for the determination of cadmium (II) in three river samples. A comparison was made between the proposed method of analysis with the classical method (HANNA instrument for turbidity measurement) using the standard additions method via the use of ANOVA-treatments. It was noticed that there is a significant difference at α=0.05 between the two methods at level < 0.05 was obtained. On that basis the new method can be accepted as an alternative analytical method.

تم تطوير طريقه تحليلية جديدة , تميزت بالسرعة والحساسية لتقدير ايون الكادميوم الثنائي في المحاليل المائية لثلاث نماذج عشوائية الاختيار من مياه الانهر ولمواقع مختلفة عن طريق قياس التعكرية بوساطة محلل الحقن الجرياني المستمر Ayah 6SX1-T-2D Solar. استندت الطريقة على تكوين راسب ابيض مصفر للمعقد Cd3[Fe(CN)]2 بوساطة التفاعل المباشر لايون الكادميوم (II) مع بوتاسيوم سداسي سيانيد الحديديك K3[Fe(CN)6] في وسط مائي. تم قياس التعكرية عن طريق انعكاس الضوء المسلط والمصطدم بسطوح دقائق الراسب بزاوية 0-180o. تم دراسة كافة المتغيرات الفيزياوية والكيميائية. العلاقة الخطية لمنحني المعايرة لايون الكادميوم (II) تمتد من 0.05-12 مللي مول.لتر-1 بمعامل ارتباط r = 0.9951 . حدود الكشف كانت = 25.29 نانوغم / انموذج من التخفيف التدريجي لاقل تركيز في منحني المعايرة مع انحراف قياسي نسبي مئوي RSD% اقل من 1.5 % لتركيز 8 مللي مول.لتر-1 (n=5) من ايون الكادميوم (II) . طبقت الطريقة بنجاح لتقدير ايون الكادميوم (II) في ثلاث نماذج لمياه النهر. اجريت مقارنة بين الطريقة المستحدثة للتحليل والطريقة التقليدية لقياس التعكرية باستخدام منحني الاضافات القياسية وبوساطة المعالجة بتحليل المتغيرات (ANOVA). لوحظ انه يوجد فرق جوهري بين الطريقتين عند مستوى قناعة 95% , حيث تم الحصول على sig > 0.05 . على هذا الاساس بالامكان قبول الطريقة الجديدة كطريقة تحليلية بديلة.


Article
New Method for Determination of Molybdenum(VI) through Flow Injection Analysis Via the Consumption of Liberated Oxygen from Reaction System Ammonia-Hydrogen peroxide-Molybdenum(VI) in the Presence of Pyrogallol
طريقة جديدة لتقدير الموليبدينوم(VI) بتقنية الحقن الجرياني باستهلاك الاوكسجين المتحرر من تفاعل محلول الامونيا-بيروكسيد الهيدروجين-موليبدينوم(VI) وبوجود البايروكالول

Authors: Nagam S. Turkey نغم شاكر تركي --- Yasmeen H. Muhamad Ali ياسمين حكمت محمد علي --- Issam M.A. Shakir عصام محمد علي شاكر
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2008 Volume: 5 Issue: 4 Pages: 545-562
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This piece of research work aims to study one of the most difficult reaction and determination due to continuous and rapid variation of reaction products and the reactants. As molybdenum (VI) aid in the decomposition of hydrogen peroxide in alkaline medium of ammomia, thus means a continuous liberation of oxygen which cuases and in a continuous manner a distraction in the measurement process. On this basis pyrogallol was used to absorbe all liberated oxygen and the result is an a clean undisturbed signals. Molybdenum (VI) was determined in the range of 4-100 g.ml-1 with percentage linearity of 99.8% or (4-300 g.ml-1 with 94.4%) while L.O.D. was 3.5 g.ml-1. Interferring ions (cations and anions) were studied and their main effect was reduced using mini column cataining resin, or the separation of molybdenum via its precipitation prior to injection. The reaction system and manifold were used to determine pyrogallol (4-40 g.ml-1, L.O.D. 80 M) and hydrogen peroxide (0.1-5M, L.O.D. 50 mM). Relative standard diviation was better the 1%.

يهدفُ البحث الى دراسة واحد من التفاعلات الاكثر صعوبة في التقدير بفعل التغير المستمر والسريع لمكونات الناتج المتكون والمواد المتممة للتفاعل اذ ان فعل الموليبدينوم(VI) يسهمُ في تكسير وتجزئة بيروكسيد الهيدروجين في الوسط القاعدي من الامونيا وهذا معناهُ تكوّنٌ مستمر لغاز الاوكسجين الذي يسببُ وبشكلٍ مستمر اعاقة في عملية القياس وعلى هذا الاساس تم استخدام البايروكالول لاستهلاك الاوكسجين المتحرر والحصول على استجابات نقية خالية من التشويش بناءً على ذلك قدر الموليبدينوم باستخدام منظومة الحقن الجرياني عند طول موجي يبلغ 480 نم وتم الحصول على منحني معايرة بمدى خطي 4-100 مكغم.مل-1 وr = 0.9990 وبخطية (r2) 99.8% (او 4-300 مكغم.مل-1 وr = 0.9717 وخطية (r2) 94.43). اما حدود الكشف فبلغت 3.5 مكغم.مل-1. تمت دراسة تاثير الايونات الدخيلة الموجبة والسالبة وقد ازيل تاثيرها باستخدام مبادلات ايونية او عملية فصل الموليبدينوم(VI) بوساطة الترسيب عن الايونات الدخيلية. طُبّق النظام: NH4+-H2O2-Mo(VI)-بايروكالول لتقدير كل من البايروكالول وكان منحني المعايرة يمتدُ من (4-40) مكغم.مل-1 وr = 0.9878 عند max = 480 نم وحدود الكشف 80 مايكرومول.لتر-1 وعلى بيروكسيد الهيدروجين ويمتدُ منحني المعايرة 0.1-5 مول.لتر-1 وr = 0.9788 عند max=480 نم وحدود الكشف 50 مللي مول.لتر-1. تم تكرار كل قياس ثلاث مرات متتالية بقيم للانحراف القياسي النسبي المئوي تقتربُ من الصفر (%RSD < 1%).

Keywords

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

Arabic (2)

English (2)


Year
From To Submit

2014 (1)

2013 (1)

2010 (1)

2008 (1)