research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
New Method for the Determination of DL-Histidine by FIA and Chemiluminometric Detection
طريقة جديدة لتقدير الهستادين بتقنية الحقن الجرياني المستمر والتحسسبالبريق الكيميائي

Authors: Nagam S. Turkey نغم شاكر تركي العوادي --- Issam M.A. Shakir عصام محمد علي شاكر الهاشمي
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2010 Volume: 7 Issue: 2 Pages: 927-938
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.

يقدم البحث طريقة بسيطة وحساسة لتقدير الهستادين باستخدام منظومة الحقن الجرياني من خلال قياس البريق الكيميائي الناتج من اكسدة اللومينال بفعل بيروكسيد الهيدروجين في وسط قاعدي بوجود الهستادين بحجم 70 مايكرولتر على التيار الناقل من هيدروكسيد الصوديوم والذي يعطي بريق ازرق-بنفسجي له قمة انبعاث عند 425 نانومتر. تم الحصول على علاقة لتغير استجابة البريق مع التركيز للهستادين باستخدام معادلة الخط المستقيم وكان مدى منحني المعايرة يمتد من (5-60) مللي مول.لتر-1 ومعامل التقدير 95.79% ومعادلة الدرجة الثانية بمدى من (5-80) مللي مول.لتر-1 ومعامل التقدير 96.44% ولوحظ ان الاخيرة اكثر واقعية في التعبير عن كافة النتائج. تم التوصل الى حدود كشف (S/N = 3) 31.93 مايكروغم/70 مايكرولتر من التخفيف التدريجي لاقل تركيز في منحني معادلة الخط المستقيم. تكرارية النتائج المستحصل عليها %RSD < 5% لست قياسات متكررة. تم دراسة تاثير الايونات الموجبة والسالبة حيث ازيل تاثيرها باستخدام اعمدة صغيرة جداً معبأة بمبادل ايوني موجب او سالب ومربوطة بعد صمام الحقن مباشرةٍ.


Article
New Approach for an On-Line Turbidimetric Determination of Cadmium (II) in Different River Water Via the Use of A homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
نمط جديد لقياس التعكرية الأني لتقدير ايون الكادميوم في مختلف مياه الانهر من خلال محلل جديد مصنع محليا للحقن الجرياني المستمر Ayah 6SX1-T-2D Solar) ).

Authors: Nagam S.Turkey نغم شاكر تركي العوادي --- Omar A. Yassin عمر اياد ياسين
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4A Pages: 1402-1414
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly developed analytical method characterized by its speed and sensitivity for the determination of cadmium (II) in aqueous solution in three randomly chosen samples from river water at different locations via turbidimetric measurement by Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity was measured via the reflection of incident light that collides on the surfaces precipitated particles at 0-180o. Chemical and physical parameters were investigated. Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with correlation coefficient r = 0.9951. The limit of detection 25.29 ng/ sample from the step wise dilution for the minimum concentration in the linear dynamic range of the calibration graph with RSD % lower than 1.5% for 8 mmol.L-1 (n=5) concentration of cadmium (II). The method was applied successfully for the determination of cadmium (II) in three river samples. A comparison was made between the proposed method of analysis with the classical method (HANNA instrument for turbidity measurement) using the standard additions method via the use of ANOVA-treatments. It was noticed that there is a significant difference at α=0.05 between the two methods at level < 0.05 was obtained. On that basis the new method can be accepted as an alternative analytical method.

تم تطوير طريقه تحليلية جديدة , تميزت بالسرعة والحساسية لتقدير ايون الكادميوم الثنائي في المحاليل المائية لثلاث نماذج عشوائية الاختيار من مياه الانهر ولمواقع مختلفة عن طريق قياس التعكرية بوساطة محلل الحقن الجرياني المستمر Ayah 6SX1-T-2D Solar. استندت الطريقة على تكوين راسب ابيض مصفر للمعقد Cd3[Fe(CN)]2 بوساطة التفاعل المباشر لايون الكادميوم (II) مع بوتاسيوم سداسي سيانيد الحديديك K3[Fe(CN)6] في وسط مائي. تم قياس التعكرية عن طريق انعكاس الضوء المسلط والمصطدم بسطوح دقائق الراسب بزاوية 0-180o. تم دراسة كافة المتغيرات الفيزياوية والكيميائية. العلاقة الخطية لمنحني المعايرة لايون الكادميوم (II) تمتد من 0.05-12 مللي مول.لتر-1 بمعامل ارتباط r = 0.9951 . حدود الكشف كانت = 25.29 نانوغم / انموذج من التخفيف التدريجي لاقل تركيز في منحني المعايرة مع انحراف قياسي نسبي مئوي RSD% اقل من 1.5 % لتركيز 8 مللي مول.لتر-1 (n=5) من ايون الكادميوم (II) . طبقت الطريقة بنجاح لتقدير ايون الكادميوم (II) في ثلاث نماذج لمياه النهر. اجريت مقارنة بين الطريقة المستحدثة للتحليل والطريقة التقليدية لقياس التعكرية باستخدام منحني الاضافات القياسية وبوساطة المعالجة بتحليل المتغيرات (ANOVA). لوحظ انه يوجد فرق جوهري بين الطريقتين عند مستوى قناعة 95% , حيث تم الحصول على sig > 0.05 . على هذا الاساس بالامكان قبول الطريقة الجديدة كطريقة تحليلية بديلة.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2014 (1)

2010 (1)