Study of Stability of Personal Dosimeter
دراسة استقرارية افلام قياس مستوى التعرض كسجل دائم للجرع

Authors: Husam Ahmad حسام احمد --- Eman Amori ايمان اموري --- Nahida J.H. Al_Mashhadani ناهدة جمعة المشهداني
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2009 Volume: 6 Issue: 4 Pages: 698-704
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The study is carried out by using personal dosimeters (film badge). The films are irradiated to absorbed dose of range (0.01-10000 rad). The calibration curves are drawn by using the ordinary method taking into account the filtration effects in three regions (D (Pb/Sn),D(Du),D(300). The calibration films are stored in ambient condition. It is found that the optical density increases, which is attributed to the photodegradation of the films may induce localized states in the energy gap causing increasing in optical absorption, but optical density decreases, which attributed to the photodegradation of the films may cause some cracks at the film surface during the first month, whereas at the rest months we see clear stability in optical density for the irradiated films. Before irradiation, there is increasing in optical density during the second month, and decreasing in optical density during the rest months. It is concluded that aging effects must be considered for personal dosimeter before and after irradiation to know its use ability as a permanent record.

أجريت هذه الدراسة على افلام قياس مستوى التعرض الشخصي (الفلم باج ) والتي تستخدم لمراقبة التعرض الشخصي للعاملين في حقل الاشعاع في العراق . تمت معايرة الافلام بأستخدام (Ra-226) الباعث لاشعة كاما ذي النشاط الاشعاع mCi ) 10.54) ،وذلك بتشعيع الافلام بجرعة تقع ضمن المدى (0.01-10000rad) أعتمدت الطريقة الاعتيادية برسم ثلاث منحنيات في ثلاثة مناطق (المرشحات D(Pb/Sn),D(Du),D(300)). درس تاثيرالتقادم قبل وبعد تشعيع افلام قياس مستوى التعرض الشخصي وقد وجد بأنه هناك زيادة في الكثافة الضوئية أي زيادة في الامتصاصية وذلك ينجم عن التفكك الضوئي للعينة والذي يعمل على زيادة الامتصاصية(وبالتالي زيادة في الكثافة الضوئية ) كما وجد تناقص بالكثافة الضوئية نتيجة التفكك الضوئي الذي يعمل على احداث تشققات (Cracks )في العينة وبالتالي يحدث تناقص في الامتصاصية وبالتالي (تناقص في الكثافة الضوئية ) خلال الشهرالاول , في حين نلاحظ استقرارية واضحة خلال بقية الاشهربالنسبة للافلام المشععة. اما بالنسبة للافلام غير المشععة نلاحظ ازدياد في الكثافة الضوئية خلال الشهر الثاني وتناقصها خلال بقية الاشهر. لذا فمن الضروري الاخذ بالحسبان تأثيرالتقادم لمعرفة مدى امكانية استخدام الافلام كسجل دائم للجرع.


Article
Structure and Spectrophotometric (UV) Study of γ-Irradiated PMMA for Using as a Low dose Dosimeter
ميثااكريليت المشع بأشعة كاما لاستخدام كمقياس للجرع الاشعاعية الواطئة

Loading...
Loading...
Abstract

Keywords


Article
Spectrophotometric Study of م-Irradiated PM-355
الدراسة الطيفية PM-355المشعع باشعة كاما

Authors: Mohammed T. Abdul Nabi محمد طارق عبد النبي --- Nada F. Tawfiq ندى فاضل توفيق --- Nahida J.H.Al-Mashhadani ناهدة جمعة المشهداني
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2009 Volume: 6 Issue: 3 Pages: 584-589
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The aim of the present work is concerned with the effect of γ-irradiation on PM-355 with absorbed dose of (30-160Mrad) range. This polymer is evaluated spectrophotometrically for use as high dose dosimeters. The absorption spectra of irradiated samples showed radiation induced absorption changes. There is an increment in absorption proportional with absorbed dose. This increment is attributed to interfaces traps which, are formed by irradiation. Calibration curve was drawn .The linear relation was found in calibration curve, and dosimeter range was determined from the linear part. The linearity in response curve suggested that PM-355 could be used as dosimeter within (30-160Mrad) rang. Energy gap shift was used as a second tool to determine the dosimeter range. It was found that PM-355 energy gap systematically decreasing with absorbed dose, and it could be used as a second tool to determine the dosimeter range.

ان الهدف من هذا البحث يتعلق بدراسة تاثير تشعيع PM-355باشعة كاما وبالجرع الاشعاعية التي تقع ضمن المدى30-160Mrad)).تم تحليل البوليمر طيفيالاستخدامه كمقياس للجرع العالية.اظهرت اطياف الامتصاص للنماذج المشععة تغيرا في الامتصاصيةوالمحتث بالاشعاع.هناك زيادة في الامتصاصة بازدياد الجرعة الممتصة.اعزيت الزيادة الىالمصائد البينية المتكونة بتاثير الاشعاع.رسمت منحنيات المعايرة.وجد علاقة خطية في منحنيات المعايرة.ان خطية منحنيات الاستجابةحددت امكانية استخدام PM-355 مقياس الجرع ضمن المدى30-160Mrad)).استخدم الزحف في فجوة الطاقة كوسيلة ثانية لتحديد مدى مقياس الجرع.وجد تناقص نظامي في فجوة الطاقة ل PM- 355 مع الجرعة الممتصة,ويمكن استخدامها كوسيلة ثانيةلتحديد مدى مقياس الجرع.