A sensitive spectrophotometric determination of tadalafil in pharmaceutical preparations and industrial wastewater samples
التقدير الطيفي للتدالافيل في المستحضرات الصيدلانية والمياه الصناعية المطروحة

Author: Nief Rahman Ahmed نايف رحمان احمد
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2013 Volume: 10 Issue: 3عدد خاص بموتمر الكيمياء Pages: 1005-1013
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7μg/ mL ,with molar absorptivity and Sandell ҆ s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations (tablets) and industrial wastewater samples. The proposed method was validated by sensitivity and precision which proves suitability for the routine analysis of tadalafil in true samples.

تم تطوير طريقة طيفية في المنطقة فوق البنفسجية تمتاز بالبساطة والدقة والضبط والسرعة والحساسية العالية لتقدير عقار التدالافيل في مستحضراته الدوائية وفي المياه الصناعية المطروحة حيث تم قياس كميات تتراوح بين 7,1 جزء بالمليون وبمعامل امتصاص مولاري مقداره0.783×105 لترمول سم ودلاله ساندل4.97نانوغرام/سم2وان الانحراف القياسي النسبي للطريقة اقل من 1.7%والدقة(معدل الاسترجاعية)100±0.13وان حدي الكشف والكمي للطريقة هما0.18 و 0.54 مايكرو غرام /مل على التوالي.وطبقت الطريقة بنجاح لتقدير الدواء في مستحضراته الصيدلانية (أقراص) وفي المياه الصناعية المطروحة واقترحت الطريقة للتحليل الروتيني كونها ذات حساسية عالية وبسيطة وسريعة وذات دقة جيدة


Article
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
تقدير الكوافنسين بطريقة كروماتوغرافيا السائل ذات الاداء العالي في مستحضرات الشراب وفي المياه الصناعية المطروحة

Authors: suhaib N. Lottfi صهيب نايف لطفي --- Nief Rahman Ahmed نايف رحمان احمد
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2013 Volume: 10 Issue: 3عدد خاص بموتمر الكيمياء Pages: 1014-1022
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml respectively. The method was validated for its linearity, precision and accuracy .The proposed method was successfully applied for the determination of guaifenesin in syrups and industrial effluent samples.

تم اختبار طريقة كروماتوغرافيا السائل ذات الأداء العالي حيثتميزت الطريقة بالبساطة والدقة والسرعة والضبط العالي لتقدير الكوافنسين في حالته النقية وفي بعض مستحضراته الصيدلانيةوفي المياه الصناعية المطروحة.حيث تم الفصل باستخدام كولوم نوع(L7)و استخدام مزيج الميثانول الماء واسيتونتريل كوسط ناقل نسبة (10:10:80) حجمحجمحجم. وبسرعة جريان 1 مل/دقيقة واستخدام مكشاف الاشعة فوق البنفسجية عند الطول الموجي 254 نانوميتر وفي درجة حرارة المحيط حيث كان زمن الاحتباس 2.4 دقيقه, وامكن تقدير الكميات التي تتراوح بين 0.08-0.8ملغراممل وبحدي كشف وكمي هما 6 و 18 مابكروغراممل على التوالي واختبر مصداقية الطريقة بقياس استقامة الخط البياني والضبط والدقة واستخدمت الطريقة بنجاح لتقدير الكوافنسين في مستحضرات الشراب وفي المياه الصناعية المطروحة.