research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
A generalL Velocity Profile For Alaminar Boundary Layer Over Flat Plare With Zero Incidence

Author: Qussai J. Abdul-Ghafour
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 5 Pages: 1223-1231
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A general velocity profile for a laminar flow over a flat plate with zero incidence is obtained by employing a new boundary condition to the other available boundary conditions. The general velocity profile is mathematically simple and nearest to the exact solution. Also other related values, boundary layer thickness, displacement thickness, momentum thickness and coefficient of friction are nearest to the exact solution compared with other corresponding values for other researchers.

تم ايجاد معادلة عامة للسرعة خلال الطبقة المتاخمة للجريان الطباقي فوق السطح المستوي من خلال توظيف ظرف محيطي جديد بالاضافة الى الظروف المحيطية المتوفرة. المعادلة العامة المستحصلة ذات صيغة رياضية بسيطة واقرب ماتكون من الحل التام. تم استخدام المعادلة العامة للسرعة لايجاد القيم ذات العلاقة, سمك الطبقة المتاخمة و سمك الازاحة و سمك الزخم و معامل الاحتكاك وكانت النتائج هي الاقرب للحل التام مقارنة مع القيم المناظرة لها والمستحصلة من الباحين السابقين.


Article
A GENERAL VELOCITY PROFILE FOR A LAMINAR BOUNDARY LAYER OVER FLAT PLATE WITH ZERO INCIDENCE

Author: Qussai J. Abdul-Ghafour
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 6 Pages: 1614-1621
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A general velocity profile for a laminar flow over a flat plate with zero incidence is obtained by employing a new boundary condition to the other available boundary conditions. The general velocity profile is mathematically simple and nearest to the exact solution. Also other related values, boundary layer thickness, displacement thickness, momentum thickness and coefficient of friction are nearest to the exact solution compared with other corresponding values for other researchers

تم ايجاد معادلة عامة للسرعة خلال الطبقة المتاخمة للجريان الطباقي فوق السطح المستوي من خلال توظيف ظرف محيطي جديد بالاضافة الى الظروف المحيطية المتوفرة. المعادلة العامة المستحصلة ذات صيغة رياضية بسيطة واقرب ماتكون من الحل التام. تم استخدام المعادلة العامة للسرعة لايجاد القيم ذات العلاقة, سمك الطبقة المتاخمة و سمك الازاحة و سمك الزخم و معامل الاحتكاك وكانت النتائج هي الاقرب للحل التام مقارنة مع القيم المناظرة لها والمستحصلة من الباحين السابقين


Article
CFD Simulation of Enhancement Techniques in Flat Plate Solar Water Collectors

Authors: Jafar Mehdi Hassan --- Qussai J. Abdul-Ghafour --- Mohammed F. Mohammed
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 3 Pages: 751-761
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The present work is a numerical study of thermal performance of modified flat plate solar water collectors. Numerical simulations have been done by solving the governing equations (Continuity, Momentum and Energy) equations in the laminar regime , three dimensions by using the FLUENT software version (14.5). The effect of flow on temperature distribution of flat plate water collectors by inserting (twist strip with twist ratio (3), helical spring surrounding the solid shaft) inside riser pipes is numerically simulated and compared with solar collector without inserting device inside its riser pipes at flow rates of (100)ℓ/h . The numerical simulation results show that the flat plate water, solar collectors with the inserted, twist strip and helical spring that’s surround the solid shaft were higher enhancement of heat transfer than without inserted devices. The useful energy in case of twist strip is (10%) higher than the case of flat plate solar collector without enhancement device. Also, the case of helical spring is increased (6.8 %) than the twist strip, and (16.2%) than collector without enhancement device for the same mass flow rate.

يوضح البحث الحالي دراسة عددية لتحسين الاداء الحراري لمجمعات الماء الشمسية المسطحة. تمت الدراسة العددية بحل المعادلات الحاكمة (الاستمرارية ، الزخم والطاقة) لجريان طباقي ثلاثي الابعاد باستخدام برنامج (Fluent 14.5 ) . تضمن الحل العددي دراسة تاثير الجريان وتوزيع درجات الحرارة لمجمعات الماء الشمسية من خلال اقحام ادوات (شريط ملتوي ذات نسبة التواء (3) ، محور صلب محاط بنابض حلزوني ) داخل انابيب رفع الماء ومقارنتها مع مجمع شمسي بدون اقحام ادوات داخل انابيب رفع الماء عند معدل تدفق (100) لتر/ ساعة. اظهرت النتائج العددية ان اقحام شريط ملتوي ذات نسبة الالتواء (3) ومحور صلب محاط بنابض حلزوني داخل انابيب رفع الماء تؤدي الى تحسين انتقال الحرارة بشكل ملحوض عن الحالة بدون اقحام هذه الادوات . ان الطاقة المفيدة في حالة الشريط الملتوي اعلى بمقدار ((10% في حالة المجمع الشمسي بدون ادوات اقحام . كذلك في حالة اقحام محور صلب محاط بنابض حلزوني بلغت الزيادة في مقدار الطاقة المفيدة 6.8 %)) عن حالة الشريط الملتوي و 16.2% )) عن حالة المجمع الشمسي بدون ادوات اقحام عند نفس معدل التدفق.


Article
Experimental and Theoretical Study of Vacuum Cooling System
دراسة تجریبیة ونظریة لمنظومة التبرید بالتفریغ

Authors: Ahmed A. M. Saleh --- Qussai J. Abdul Ghafour --- Luay T. Al-Rawi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 14 Part (A) Engineering Pages: 2619-2631
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A vacuum cooling system and the parameters which affect on its performancewere studied experimentally and theoretically. For the experimental study the rig wasbuilt up to studying the performance of cooling system in three cases. These casesare: Cooling water by vacuum only, cooling water in conventional method, andcooling water by vacuum with condensation.The experimental results show that the addition of a condenser to the vacuumcooling system leads to sweep of largest amount of generated vapor, also the timeconsumed for the process was decreased. The times required for cooling 45 g fromwater from temperature 29oC to 10oC for the three test cases were 4375 second, 3535second and 263 second, respectively. Vacuum cooling with condenser is a fastcooling of three systems test, which is about (13.7 times) faster than the system ofnatural convection cooling. To work properly, the existence of condenser is veryimportant in vacuum cooling. It normally removes the large amount of water vaporgeneration (about 94%).For the theoretical study, a computer program was built up by employing thegoverning equation to simulate the performance of the vacuum cooling system. Thetheoretical results indicate an acceptable agreement with the experimental results.Also, the results show that the decreasing of condenser temperature causes decreasingof cooling time according to the equation (t = 0.2031Tcd4 - 2.8958 Tcd3 + 16.406Tcd2 - 21.104 Tcd + 313.39), and increasing the evaporation surface area leads todecreasing of cooling time according to the equation (t=1/ (0.0006*Area+0.0005)),and the increasing of water mass causes in increasing of cooling time according to theequation (t=7.2667*mass+14).


Article
Experimental Study of the Effect of VentilatedCavity Wall on Building Cooling Load
دراسة عملية لإيجاد تأثير جدار ذي تجويف مھوى على حمل تبريد حيز معين

Authors: Qussai J. Abdul Ghafour قصي جھاد عبدالغفور --- Bashar Kamil Mahmoud بشار كامل محمود
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 7 Part (A) Engineering Pages: 133-147
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The study, which was made during August showed through calculations, that the use of ventilated cavity wall by air with temperature equal to the temperature of the space (about 25.5oC) and within air velocities range(0.0785,0.157,0.282m/s) made a percentage reduction in the cooling load caused by heat gain from the wall by(65.1,70.7,75.7%) compared with the conventional wall. Also the study showed an increase in the cavity thermal resistance with increasing ventilated air velocity and a linear relationship is obtained within the test velocities range.The experimental results of the study showed that the use of ventilated cavity wall reduced the average temperature of the inner surface of the wall during the day, andthat the amount of reduction was an average(1.45,1.53,1.71oC)during August when compared with the conventional wall and within the test velocities range, as well asthe use of ventilated cavity wall reduced the temperature difference range of the inner surface of the wall during the day and that the amount of reduction was close within therange of testvelocities, the average of reduction ranged between (0.94,1.01oC)during August when compared with the conventional wall .

تظهر الدراسةالتي اجريت خلال شهر آب ومن خلال الحسابات ان استخدام الجدار ذي التجويف المهوى بهواء ذي درجة حرارة مساوية لدرجة حرارة الحيز (بحدود 25.5oC) وضمن مدى سرع تهوية(0.0785, 0.157, 0.282 m/s) ادى الى تخفيض حمل التبريد نتيجة الكسب الحراري عبر الجدار وبنسب (65.1, 70.7, 75.7 %) بالمقارنة مع الجدار التقليدي. كذلك بينت الدراسة زيادة المقاومة الحرارية للتجويف الهوائي للجدار عند زيادة سرعة التهوية له وتم ايجاد علاقة (خطية) لذلك وضمن مدى سرع الاختبار. وبينت النتائج العملية للدراسة ان استخدام الجدار ذي التجويف المهوى يعمل على تخفيض متوسط درجة حرارة السطح الداخلي للجدارخلال اليوم،وان مقدارالتخفيضكان بمعدل1.45, 1.53, 1.71oC)) خلال شهر آبعند المقارنة مع الجدار التقليدي وضمن مدى سرع الاختبار، وكذلك يعملعلى تخفيض مدى التغير في درجة الحرارة للسطح الداخلي للجدار خلال اليوم,وان مقدار التخفيض الحاصل كان متقارباً ضمن مدى سرع الاختبار حيث تراوح معدله بين (0.94, 1.01oC) خلال شهر آب عند المقارنة مع الجدار التقليدي.


Article
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
تأثير ادخال شرائط ملتوية على اداء مجمعات الماء الشمسية المسطحة

Authors: Jafar M. Hassan جعغر مهدي حسن --- Qussai J. Abdul-Ghafour قصي جهاد عبد الغفور --- Mohammed F. Mohammed محمد فوزي محمد
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2015 Volume: 11 Issue: 3 Pages: 37-46
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at different flow rate used (60,100 and 150) ℓ /hr. were 49 %, 57% and 63% respectively.

لغرض تحسين كفاءة مجمعات الماء الشمسية المسطحة بدون احداث تغيير في الشكل الاصلي مع اضافة بسيطة للتكلفة، تم اقحام شرائط ملتوية داخل انابيب رفع الماء. تم استخدام ثلاثة مجمعات شمسية مسطحة لغرض الدراسة. حيث وضعت مجموعة من الشرائط الملتوية مختلفة في نسبة الالتواء (TR=3,4,5) داخل انابيب رفع الماء لكل مجمع . تم ربط المجمعات على التوازي (شكل –Z ) وتعريضها للضروف نفسها (شدة الاشعاع الشمسي و درجة حرارة المحيط). اوضحت النتائج العملية ان اعلى معدل لانتقال الحرارة حصل عند نسبة التواء (3). ونتيجة لذلك و لنسبة الالتواء نفسها كانت قيمة الكفاءة اليومية للمجمع الشمسي لعدد من قيم معدل الجريان (60,100,150) لتر/ ساعة بلغت 49% ،57% و63% على التوالي .

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (4)

Arabic (1)

Arabic and English (1)


Year
From To Submit

2017 (1)

2015 (2)

2013 (1)

2011 (2)