research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Removal Of Dyes From Textile Effluent By Adsorption Onto Oven Dried Alum Sludge

Author: Rasha H. Salman
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 2 Pages: 5249-5262
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present study deals with the removal of dyes from the effluent of the state company for cotton textile industries located at Al-Khadmya by using oven dried alum sludge (ODS) as adsorbent. Two different dyes; Direct black and solar brown are studied. Alum sludge was collected from Al-Qadisiya water treatment plant; it was heated in an oven at 105°C for 24 hours, then cooled at room temperature and crushed to produce particle sizes of 1.18-2.36 and 4-4.75 mm. Batch and fixed bed mode were used. In batch experiments the effect of oven dried alum sludge weight on adsorption process and equilibrium isotherm were studied by using 15-125 g/l of oven dried alum sludge for direct black and 15-175 g/l for solar brown, with constant initial dyes concentration of 10 mg/l and constant particle size of 4-4.75 mm. Batch kinetics experiments showed that equilibrium time was about 12-14 days. The three models Freundlich, Langmuir and Freundlich-Langmuir gave good fitting for the adsorption capacity. In the fixed bed isothermal adsorption column, the effect of initial dye concentration (Co), particle size, influent flow rate (Q) and bed depth (H) were studied. The results showed that the oven dried alum sludge was effective in adsorbing dyes with removal efficiency ranged between 90% to 92%.

تم في هذا البحث دراسة قابلية أطيان الشب المعالجة حراريا على أمتزاز وتقليل اللون من المياه المطروحة من الشركة العامة للصناعات القطنية في مدينة الكاظمية. الأصباغ التي تم استخدامها في الدراسة هي direct black و solar brown. أطيان الشب التي تم استخدامها قد جمعت من مشروع القادسية لمعالجة المياه في بغداد. تم معالجة أطيان الشب حرارياً في فرن بدرجة حرارة 105 مo ولمدة 24 ساعة وترك ليبرد الى درجة حرارة الغرفة ثم تكسيره الى حجوم 1.18-2.36 و4-4.75ملم. تم استخدام نمطين من التشغيل في هذا البحث وهي تجارب النمط الدفعي وتجارب النمط المستمر. في تجارب النمط الدفعي تم دراسة تأثير كمية أطيان الشب المعالجة حرارياً على عملية الأمتزاز باستخدام 15-125 غم/لتر من المادة الممتزة لصبغة direct black و15- 175 غم/لتر لصبغة solar brown بثبوت تركيز الصبغة الابتدائي 10 ملغم/ لتر وحجم ثابت لجزيئات المادة الممتزة 4-4.75 ملم ، أظهرت النتائج ان نسبة إزالة الأصباغ تزداد بزيادة كمية أطيان الشب المعالجة حرارياً. كذلك أظهرت النتائج ان الوصول الى حالة التعادل تستتغرق تقريباً 12 الى 14 يوم، تم تحليل النتائج باستخدام موديلات (Langmuir, Freundlich and Langmuir-Freundlich) وأظهرت النتائج ان جميع الموديلات ذات تقارب جيد. في تجارب النمط المستمر تم دراسة تأثير تركيز الأصباغ الابتدائي وحجم جزيئات المادة الممتزة ومعدل الجريان وارتفاع عمود الأمتزاز على عملية الأمتزاز. لقد أظهرت النتائج ان أطيان الشب المعالج حرارياً فعال في امتزاز الاصباغ من مياه الصرف وكانت نسبة ازالة الأصباغ تتراوح بين %90 الى %92.


Article
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
إزالة أيونات المنغنيز (Mn2+) من مياه الصرف المصنعة بواسطة تقنيات التخثر/ التعويم الكهربائية باستخدام أقطاب الفولاذ المشبكية: أيجاد الظروف المثلى بواسطة طريقة تاكوشي

Author: Rasha H. Salman
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2019 Volume: 20 Issue: 1 Pages: 39-48
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANOVA) which indicates that the percentage of contribution followed the order: time (47.42%), C.D. (37.13%), Mesh number (5.73%), and Mn initial Conc. (0.05%). The electrolysis time and C.D. were the most effective operating parameters and mesh no. had a fair influence on Mn removal efficiency, while the initial conc. of Mn. had no significant effect in the studied ranges of control factors. Regression analysis (R2= 90.16%) showed an acceptable agreement between the experimental and the predicted values, and confirmation test results revealed that the removal efficiency of Mn at optimum conditions was higher than 99%.

في هذه الدراسة ، تم التحقق في كفاءة إزالة أيونات المنغنيز من مياه الصرف الصحي بواسطة تقنيات التخثر/ التعويم الكهربائية. تمت دراسة تأثير تركيز المنغنيز الأبتدائي ، كثافة التيار (C.D.) ، زمن التحليل الكهربائي ، وحجم المشبك لأقطاب الفولاذ المشبكية في خلية دفعية من خلال تطبيق تصميم تاكوشي لايجاد الظروف المثلى لأقصى كفاءة إزالة للمنغنيز. أظهرت نتائج (S/N) أن الظروف المثلى كانت, التركيزالأبتدائي للمنغنيز هو 100جزء في المليون ، C.D.هو 4 مللي أمبير / سم 2 ، ووقت 120 دقيقة ، وشبكة ذات حجم 30 واير/أنج. أيضا ، تم بحث الأهمية النسبية لكل عامل عن طريق تحليل التباين (ANOVA) الذي يشير إلى أن النسبة المئوية للمساهمة تتبع الترتيب: الوقت (%47.42) ، C.D. (% 37.13) ، حجم المشبك (%5.73) ، و التركيزالأبتدائي للمنغنيز هو (%0.05). وقت التحليل الكهربائي و C.D. كانت هي العوامل الأكثر تأثيراً وحجم الشبكة له تأثير مقبول على كفاءة إزالة أيونات المنغنيز ، في حين أن التركيزالأبتدائي للمنغنيز لم يكن له تأثير مذكور في المدى المدروس. أظهر تحليل الانحدار (R2% = 90.16) اتفاقا جيدا بين القيم التجريبية والقيم المتوقعة ، وأظهرت النتائج تأكيد أن كفاءة إزالة المنغنيز في الظروف المثلى كانت أعلى من %99.


Article
Treatment of Industrial Waste Water using Reverse Osmosis Technique

Authors: Rasha H. Salman --- Sama M. Abdullah --- Nada S.Ahmedzeki
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2009 Volume: 15 Issue: 4 Pages: 4356-4363
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Reverse osmosis technique was used for the treatment of industrial waste water. Ions like calcium, magnesium, sodium, sulfate, and nitrate were found in the waste water of the General Company of Vegetable Oil with high concentrations which must be treated for reuse. Feed water containing the above mentioned ions was fed to the RO unit at feed flow rates (0.4 and 0.8 lit/min) and different operating pressure (2-4bar) .It is concluded that increasing operating pressure and feed flow rate improved the separation by a decrease in the concentration of ions in the product. High rejection was obtained for all ions present in feed water, ranging from (63.8-97.6%). Rejection of TDS was 87% when the concentration of TDS was reduced from 1192 to 154.94 ppm.

تقنية التنافذ العكسي أستخدمت لمعاملة المياة الصناعية . أيونات الكالسيوم و المغنيسيوم و الصوديوم و االكبريتات و النترات توجد في المياه الصناعية المطروحة من الشركة العامة للزيوت النباتية وبتراكيز عالية يجب أن تعالج لغرض اعادة استعمالها. المياه الحاوية على الأيونات أعلاه تدخل الى وحدة المعالجة بالتناضح العكسي بمعدل جريان (0.4 و0.8 لتر/دقيقة) وتحت ضغط تشغيلي (2-4 بار).لقد استنتج ان زيادة الضغط ومعدل الجريان ادى الى تحسين عملية الفصل بتقليل تركيز الايونات في الماء الناتج. أزالة عالية لكل الأيونات الموجودة في المياه الداخلة تمت بمعدل (63.8-97.6 %). ومعدل أزالة لكمية المواد الصلبة الكلية الذائبة كان (87%) عندما أنخفضت هذه الكمية من 1192 الى 154.94جزء بالمليون.

Keywords


Article
Indirect Electrochemical Oxidation of Phenol Using Rotating Cylinder Reactor

Loading...
Loading...
Abstract

Indirect electrochemical oxidation of phenol and its derivatives was investigated by using MnO2 rotating cylinder electrode. Taguchi experimental design method was employed to find the best conditions for the removal efficiency of phenol and its derivatives generated during the process. Two main parameters were investigated, current density (C.D.) and electrolysis time. The removal efficiency was considered as a response for the phenol and other organics removal. An orthogonal array L16, the signal to noise (S/N) ratio, and the analysis of variance were used to test the effect of designated process factors and their levels on the performance of phenol and other organics removal efficiency. The results showed that the current density has the higher influence on performance of organics removal while the electrolysis time has the lower impact on the removal performance. Multiple regressions was utilized to acquire the equation that describes the process and the predicted equation has a correlation coefficient (R2) equal to 98.77%. The best conditions were found to get higher removal efficiency. Removal efficiency higher than 95% can be obtained in the range of C.D. of 96-100 mA/cm2 and electrolysis time of 3.2 to 5 h. The behavior of the chemical oxygen demand (COD) mineralization denotes to a zero order reaction and the rate of reaction controlled by active chlorine reaction not by mass transfer of phenol towards the anode.


Article
Prediction of Equilibrium Mixing Index and Optimum Mixing Time for Three solid materials in Fluidized Column
التنبؤ بمعامل الخلط عند التوازن وزمن الخلط الامثل لثلاثة مواد صلبة في عمود التميع

Authors: Rasha H. Salman رشا حبيب سلمان --- Ammar S. Abbas عمار صالح عباس --- Abbas H. Sulaymon عباس حميد سليمون
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2010 Volume: 6 Issue: 4 Pages: 21-30
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Equilibrium and rate of mixing of free flowing solid materials are found using gas fluidized bed. The solid materials were sand (size 0.7 mm), sugar (size0.7 mm) and 15% cast iron used as a tracer. The fluidizing gas was air with velocity ranged from 0.45-0.65 m/s while the mixing time was up to 10 minutes. The mixing index for each experiment was calculated by averaging the results of 10 samples taken from different radial and axial positions in fluidized QVF column 150 mm ID and 900 mm height.
The experimental results were used in solving a mathematical model of mixing rate and mixing index at an equilibrium proposed by Rose. The results show that mixing index increases with increasing air velocity and mixing time until it reaches an optimum value then decrease to an equilibrium value. The results also show the dependency of the mixing index on the particle size of the tracer component.
The statistical analysis of the obtained theoretical mixing index versus the experimental mixing index shows that the standard error is 0.92 % (about 1 %) with the correlation coefficient of 0.9857 and the total residual of 0.002 for the ninth observation of the mixing index (theoretical versus experimental) over 95% confidence level.

تم دراسة معامل الخلط عند الاتزان ومعدل الخلط لمواد حرة الجريان بأستخدام عمود هواء متميع. المواد التي تم خلطها هي الرمل ( قطر الجسيمات 0.7 ملم) والسكر (قطر الجسيمات0.7 ملم) وبرادة الحديد وهي تمثل المادة الكاشفة بتركيز 15% وزنا. معدل سرعة الهواء كان بين 0.45 و 0.65 م/ثا بينما زمن الخلط كان لحد 10 دقائق. معامل الخلط لكل تجربة كان يحسب بأخذ عشرة نماذج ذات مواقع مختلفة قطريا وخطيا من عمود التميع ذو القطر الداخلي 150 ملم وأرتفاعه 900 ملم.تم أستخدام النتائج العملية في حل موديل رياضي لمعدل الخلط ومعامل الخلط عند الأتزان مقترح من قبل Rose. النتائج التجريبية أستعملت لحل موديل رياضي لمعدل الجريان و معامل الخلط عند الاتزان أقترح من قبل .Rose النتائج بينت ان معامل الخلط يزداد بزيادة سرعة الهواء وزمن الخلط حتى يصل للقيمة المثلى ثم ينخفض الى أن يصل للاتزان. نتائج معدل الخلط بينت أعتمادها على مقدار الفرق بين حجم جسيمات المادة الكاشفة. أشار التحليل الإحصائي لكل من معامل الخلط النظري و العملي إلى أن الخطأ المعياري كان 0.92 % (حوالي 1 %) و معامل ارتباط 0.9857 ومجموع المتبقيات لتسع مشاهدات كان 0.002 لمستوى ثقة 95%.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (4)

Arabic and English (1)


Year
From To Submit

2019 (1)

2016 (1)

2010 (2)

2009 (1)