Biomechanical Analysis of Human Stair Climbing (Ascending and Descending)
تحلیل میكانیكي احیائي لحركة الانسان أثناء صعود السلالم ونزولھا

Author: Sadiq Jafer Abbass
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 5 Pages: 755-774
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Because stair climbing is a common activity of daily living, the ability to do it efficiently is important to an individual's quality of life. More demanding than level walking, stair ambulation is performed with ease by healthy individuals; however, it is more difficult to perform for those with decrements in motor function, balanceproblems, or reduced lower-limb function. The difficulty with stair climbing is attributable to increased muscular demands, which are reflected in larger forces, angles, powers, moments, and ranges of motion, and these increased demands occur consistently at the knee joint. Kinematic system is used in stair climbing to record the position and orientation of the body segments, the angles of the joints and the corresponding linear and angular velocities and acceleration. The purpose of the study is to show an ideal kinematics appearance of human gait cycle for stair climbing in order to get measurement valuesthat can be depended on in the hospitals of rehabilitation, the centers of physical therapy and the clinical of medical sports as a reference data for kinematic joint parameter. In this study, 5 subjects were selected from the society, then a video recording was made for them by using a single digital video camera recorder fitted on a stand of three legs in a sagittal plane while subjects climbing a stair one by one fordifferent stair heights. Motion analysis was used to study the knee and hip joint kinematics. As a result, it was observed that the range of motion at the hip joint is between (10°-70°) at ascending and the range is between (20°-50°) at descending. The range of motion at the knee joint is between (20°-90°) at ascending and the range isbetween (10°-100°) at descending. The range of motion at the ankle joint is between (-25°-20°) at ascending and the range is between (-25°-15°) at descending. Also it was found that the angular velocity at the hip joint is between (-10-10) deg/s for ascending and (-15-25) deg/s for descending. The angular velocity at the knee joint isbetween (-40-30) deg/s for ascending and (-30-50) deg/s for descending. The angular velocity at the ankle joint is between (-30-20) deg/s for ascending and (-15-15) deg/s for descending. In this study, biomechanical characteristics of lower limb joint uponvarious stair height were presented and these data can be applied to biomedical research field that include wearable walking assistant robot.


Article
biomechanical Analysis of bone plate fixation

Author: sadiq jafer abbass
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2012 Volume: 15 Issue: 1 Pages: 149-155
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Keywords


Article
An Investigation Behavior Into Dental Biomechanical Analysis

Authors: Amal Ibrahim --- Sadiq Jafer Abbass
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2008 Volume: 11 Issue: 3 Pages: 544-551
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The aim of the study is to evaluate the Von Mises stress distribution of different human teeth model. Three-dimensional model of the maxillary central incisor, mandibular first molar and mandibular central incisor were constructed using Auto CAD (Auto CAD 2007) software and then imported to ANSYS software (ANSYS V.10) to get finite element model of each teeth. A loading simulating the 200N force was applied vertically and with different inclination to the crowns. Then same loading was applied vertically but the load was distributed along the incisal area for the incisors and at occlusal margin for the molar. Finally the crown was considered as porcelain material and the vertical load was distributed along each tooth and the Von Mises stresses were calculated. The results showed that the increase in the loading angle from 0°, 26° to 45° resulted in an increase in tooth Von Mises stress which means increase the probability of tooth failure. When the load distributed along wide region the ability of model to fail for the same loading will be decreased. Also when the crown consider as porcelain material there will be increasing Von Mises stress compare with the enamel crown for the same load region and load value

إنّ هدفَ الدراسـةِ هو تقييمَ توزيعَ إجهادِ Von Mises لنماذجِ مختلفة من أسنان الإنسـان وهـي القاطع المركزي في الفك الأعلى والقاطع المركزي للفك السفلي والضرس الأول للفك السفلي. أستعمل برنامج (2007 AutoCAD) لرسم النموذج ثلاثي الأبعاد لكل سن من الأسنان التي أستخدمت للدراسة ومن ثم تحويلها الى برنامج العناصر المحددة (ANSYS V.10) للحصول على نموذجِ العنصرِ المحـدد لـكُـلّ سن من الأسـنان التي أستخدمت في هذه الدراسة. تم تسليط حمل عمودي بمقدار 200 نيوتن بشكل عمودي وبزوايا مختلفة على منطقة التاج. نفس الحمل سلط بصورة عمودية ولكن وزع على طول منطقة الحافة العليـا للقواطـع والاضـراس لحالتين الاولى بأعتبـار التـاج مكون من المينا والحالة الثانية أعتبـار التاج مكون من الخـزف وتم أيجاد قيم اجهاد (VonMises).وتم استنتاج انه الزيادة في زاوية التحميل (مِنْ صفر°, 26° إلى 45°) أدت الى الزيادة في اجـهـاداتVon Mises مما يؤدي الى زيادة فشـل النموذج وعندما يتم توزيع الحمل على مساحة اوسع تقل احتمالية الفشل، وعند أستخدام الخزف بدلا من المينا زادت احتمالية فشل النموذج لنفس قيمة الحمل وبنفس منطقة تأثير الحمل

Keywords


Article
Finite Element Analysis of Human and Artificial Articular Cartilage

Authors: Farah Mohammed Reda Abdulateef --- Sadiq Jafer Abbass
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 4 Pages: 443-458
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Joint diseases, such as osteoarthritis, induce pain and loss of mobility to millions of people around the world. Current clinical methods for the diagnosis of osteoarthritis include X-ray, magnetic resonance imaging, and arthroscopy. These methods may be insensitive to the earliest signs of osteoarthritis. This study investigates a new procedure that was developed and validated numerically for use in the evaluation of cartilage quality. This finite element model of the human articular cartilage could be helpful in providing insight into mechanisms of injury, effects of treatment, and the role of mechanical factors in degenerative conditions, this three-dimensional finite element model is a useful tool for understanding of the stress distributions within articular cartilage in response to external loads and investigating both the prevention of injury and the pathological degeneration of the joints.In this study, 21 models were analysed by using ANSYS workbench v12.1: four normal articular cartilage models (distal femur, patella, medial and lateral tibia). A redesign to the distal femur model was done to get osteoarthritis articular cartilage (simple and deep) seven models by making partial cut without affecting the subchondral bone, and full cut with part of the subchondral bone in different diameters. Finally a treatment done by replacing the defective parts with artificial articular cartilages with different types of treatment. The finite element analysis studied depending on a Von Mises criteria and total deformation in different activities. The results shows that Autologous Chondrocyte Implementation is the best treatment way and it is close by 87.50% to normal cartilage. This procedure can be used as a diagnostic procedure for osteoarthritic patients and to choose the best treatment options.

أمراض المفاصل، كـ (إلتهاب المفاصل الضموري)، تسبب الالم وعدم القدرة على الحركة لملايين الناس في العالم. طرق التشخيص الحالية للمرضى تستخدم الاشعة السينية، و جهاز الرنين المغناطيسي، و الناظور المفصلي، هذه الطرق لا تكون حساسة لإكتشاف العلامات الاولى لحدوث هذا المرض. لذلك هذه الدراسة بحثت طريقة جديدة طُورت حسابياً لتستخدم في تقييم كفاءة الغضروف عن طريق تصميم نموذج للغضروف المفصلي في الانسان بإستخدام العناصر المحددة لإلقاء الضوء على ميكانيكية الجرح و تأثيرات المعالجة و دور العوامل الميكانيكية في حدوث الأضرار و يعتبر نموذج العناصر المحددة ثلاثي الابعاد للغضروف المفصلي هذا طريقة مفيدة في فهم توزيع الاجهاد ضمن الغضروف المفصلي ضد الاجهادات الخارجية و بحث كل من منع حدوث الاضرار والامراض التي تحدث في المفاصل. في هذه الدراسة تم تحليل واحد وعشرون نموذجاً بإستخدام برنامج (ANSYS workbench v12.1) يتضمن أربع نماذج للغضروف المفصلي الطبيعي (غضروف عظم الفخذ السفلي، و غضروف الرضفة، و غضروفي عظم القصبة الداخلي والخارجي)، وبعدها تم إزالة جزء من الغضروف المفصلي لعظم الفخذ ليصبح كأنه مصاب بمرض (إلتهاب المفاصل الضموري) البسيط والعميق وذلك عن طريق عمل قطع جزئي بدون التأثير على العظم الذي تحت الغضروف، ومن ثم عمل قطع كامل لجزء من الغضروف مع جزء من العظم الذي تحته، وبأبعاد مختلفة بكلتا الحالتين، ثم معالجة الجزء المقطوع بإستبداله بغضروف مفصلي صناعي بإستخدام عدة طرق للعلاج ثم دراسة التحليل بإستخدام العناصر المحددة بالاعتماد على معايير (Von Misses) و التشوه الكلي في نشاطات مختلفة.


Article
A COMPARATIVE STUDY BETWEEN THE INTERNAL AND EXTERNAL BONE FIXATION METHODS
دراسة مقارنة بين طرق التثبيت الداخلية والخارجية للعظام

Author: Sadiq Jafer Abbass صادق جعفر عباس
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2011 Volume: 11 Issue: 4 Pages: 601-618
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

AbstractThe basic goal of fracture fixation is to stabilize the fractured bone, to enable fast healing ofthe injured bone, and to return early mobility and full function of the injured extremity [1]. Thecomputerized tomography scan slices of the femur bone of one patient were translated to theANSYS V.(10) program and then the solid model (3-D) model was built and analysed by the finiteelement method under different loading conditions for each method of fixation. Finite elementanalysis would help to reveal stress pathways across the shaft of the femur bone and the sites of the8 screws or pins fixed at the shaft of the femur above and below the fracture site.In the internal fixation method two types of screws' materials can be studied. Firstlystainless steel and secondly cobalt chromium. The stress distributions were studied for each screwmaterial for different body weights. While in the external fixation method the stress distributions foronly stainless steel pins were studied.The stress distributions for six pins or screws fixed at the fractured bone above and belowthe fracture site for each method of fixation were studied.The von mises stresses of the cobalt chromium screws fixed internally are less than the vonmises stresses of the stainless steel for each of the body weight. The stresses of the pins fixedexternally are greater than the stresses of the same screws fixed internally.When decreasing the number of the screws or the pins the stress values will increase;therefore when using eight screws or pins the stresses are less than those when used six screws orpins for each method of fixation (internal and external).

اد 23456 76839 و ;<=>? م AB56C ا EF ر =H5I6 ا JK46 ا ELI5M6 ر 2>LI6 ا JK46 ا NMOPQ 2 ر ھ 2>L6 ا NMOPQ EF STATU ف ا WX6 إن ار. =H5I6 ف ا =[6 ;FAL6 ا ;]M ظ26 و ا ;9=_6 ا ;M?A` ا =LOFA3XM\_Q J53M6 د A34?U ا S3qrP6 ذج ا 23Io6 ء ا Ao? JQ و Ansys aFAb=? c6 إ Ndb Sb وe\_6 اس ا =]I6 ا ;[T ا2? ذة 2ijI6 ا 8k]6 ا JK< lm ا=n إن. NMOP56 ا S5dt= ط rL6 ;]5kF ى 2` =MqjQ N_Q دة W_I6 ا =wAo46 ا ;dt=[?أو S3y ا=O6 ا z3` ا2F S3{ 76839 و 83k]6 ا J3K< ع 83} S3{ ~H36 وا W€36 دات ا A3X} ا z3t ز2Q ر A3X ظƒ ت WL6 ا z`2F N_Q ق و 2{ JK46 ع ا 8} S{ ;5OPF =MFA>F ;MbAIq A دھ W< و =MFA>I6 اN3?2L6 ا ;LMO3T ;3MbAP6 أ وا W…36 وم A3dI6 ذ ا C23]6 ام ا Wk5TA? c6 وU ا NT در Sy ا=O6 اد ا 2F EF EM<2b م Wk5T ا Si اW6 ا NMOP56 ا ;dt= ط S{دات A3X}C ا z3t ز2Q ;3T درا J3Q S} رA3k6 ا N3MOP56 ا S3{ A3IoM? . ;3]5kF وزان U EMQ دAI6 ا EF ع 2b †L6 NT دات در AX}C ا zt ز2Q وم. إن =9. ~d{ أ W…6 وم AdI6 ذ ا C2]6 ع ا 2b EF Sy=? ام Wk5T ا Wo<


Article
Kinematic analysis of human gait cycle
التحليل الكينماتيكي البشري للحركة الدائرية

Author: Sadiq Jafer Abbass صادق جعفر عباس
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2013 Volume: 16 Issue: 2 Pages: 208-222
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Kinematic system is used in gait analysis to record the position and orientation of the body segments, the angles of the joints and the corresponding linear and angular velocities and acceleration. Gait analysis is used for two very different purposes to aid directly in the treatment of individual patients and to improve our understanding of gait through research. The purpose of the study is to show an ideal kinematics appearance of human gait cycle for walking in order to get measurement values that can be depended on in the hospitals of rehabilitation, the centers of physical therapy and the clinical of medical sports as a reference data for kinematic joint parameter. In this study, 20 subjects and one abnormal subject (undergoes foot flat) were selected from the society; the 20 subjects were not to have any pathology that would affect gait and had to be unfamiliar with treadmill walking, then a video recording was made for them by using a single digital video camera recorder fitted on a stand of three legs in a sagittal plane while subjects walked on a motorized treadmill one by one, the treadmill is often used in rehabilitation programs because it allows standard and controlled conditions and it needs small space. Then by special motion analysis software (Dartfish) was used to study the knee and hip joint kinematics and the spatial –temporal gait parameters (step length, stride length, stride duration, cadence) from the video recording. Results obtained from the Dartfish program are important in understanding that the knee and hip angles differ in each gait cycle, similarly to spatial- temporal parameters, the spatial- temporal parameters differ in each gait cycle analyzed for subjects.

يستخدم نظام الكينماتيك في تحليل الحركة لتسجيل موقع ودوران أجزاء الجسم، زوايا المفاصل, والسرعة الخطية والزاوية والتعجيل الخطي والزاوي، تحليل الحركة يستخدم لغرضين مختلفين جداً لكي يساعد بصورة مباشرة في معالجة المرضى ولتعميق مفهوم الحركة لدينا من خلال البحث. الغرض من هذه الدراسة هو اجراء وتصميم نموذج للمظاهر الكينماتيكية المثالية الخاصة بحركة المشي من اجل الحصول على قيم قياسية يمكن الاعتماد عليها في مستشفيات التأهيل ومراكز الطب الفيزيائي و العيادات ذات التخصص الرياضي كقاعدة بيانات للرجوع اليها. في هذه الدراسة تم اختيارعشرين شخص من المتبرعين وشخص واحد يعاني من مرض ذا تأثير على الحركة ، هؤلاء الأشخاص العشرون لا يملكون أي مرض ذا تأثير على الحركة, وليس لديهم سابق معرفة في كيفية السير على جهاز السير المتحرك ,حيث تم أجراء تصوير لهؤلاء الأشخاص باستخدام كاميرة تصوير فيدوية رقمية Sony) نوع) مثبتة على حامل من ثلاث أرجل في مستوى جانبي بينما الأشخاص يسيرون على جهاز السيرالألي المتحرك بصورة متسلسلة, أن جهاز السير المتحرك غالبا ما يستخدم في برامج التأهيل لأنه يسمح بحالات ثابتة ومسيطرة في مساحة صغيرة. وباستخدام برنامج التحليل الحركي (Dartfish) تم دراسة كينماتيكية مفاصل الورك والركبة وحساب المتغيرات الزمنية – المكانية (طول الخطوة، طول الخطوة الكاملة, زمن الخطوة الكاملة ، التردد) من التصوير الفديوي.أن النتائج التي تم الحصول عليها من برنامج (Dartfish) كانت مهمة في فهم أن زوايا الورك الركبة تختلف في كل دورة مشي كاملة ، بصورة مشابهة للمتغيرات الزمنية – المكانية ، وان المتغيرات الزمنية – المكانية تختلف في كل دورة مشي كاملة للأشخاص.


Article
Investigating of A Modified Model for Human Eye Movement

Authors: Sadiq Jafer Abbass --- Sheelan Kameran Baker
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2013 Volume: 16 Issue: 1 Pages: 111-124
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this research a biological model was modified upon a homomorphic sccadic eye movement model by adding and calculating the mass of eye and the elasticity of eye tendon and take a primary position only. According to this modification, equation with six order was appeared which was processed with a MATLAB SIMULINK to get a desire results of theta, velocity and acceleration in the normal case.For the same model, a disease was estimated to evaluate the results of theta and how it is affected by this disease which was estimate the increase and decrease happened in the primary elastic element and viscosity. After theta controller was added to the model to control the system and get the desire angle which is equal to 15º in the normal case while in the system with disease, the PI controller that used can control only the system during normal case while in the system with disease, the PI controller could not control the system to get the desired angle.

يشهد العلم اليوم تطوراً رئيساً ومتزايد بسرعة عالية في الأختراعات والأبداعات في كافة الحقول العلمية وبضمنها الهندسة الطبية، التي شهدت تحسناً في الأبداعات البشرية التي تخدم هذا المشروع وتوضح تصميم الحركة الميكانيكية للعين البشرية والذي يتضمن ثلاث حركات هي الأساسية والثانوية والثلاثية. تم تطوير نموذج لحركة العين الميكانيكية الاحيائية باضافة وحساب كتلة العين ومعامل مرونة وتر العين في حالة حركة العين الابتدائية. قد ظهرت طبقا لهذا التطوير، معادلات من الدرجة السادسة والتي عولجت باستخدام MATLAB SIMULINK للحصول على النتائج المطلوبة للزاوية والسرعة والتعجيل في الحركة الطبيعية.تم أخذ النتائج لنفس النموذج في حالة مرض تم افتراضه لاختبار النتائج المحصلة للزاوية وكيف تتاثر بالمرض الذي تم افتراضه حيث لوحظ كون زيادة ونقصان تصيب معامل المرونة الابتدائية للعين ولزوجة العين. بعد ذلك تم اضافة مسيطر للموديل ليتم السيطرة على النظام الحركي للعين ولحصول الزاوية المطلوبة والتي تساوي 15° في الحالة الطبيعية وفي حالة المرض لكن المسيطر الذي تم استعماله استطاع فقط السيطرة على النظام الحركي للعين بالحالة الطبيعية بينما في حالة المرض فالمسيطر لم يستطع السيطرة على النظام الحركي للعين للحصول على الزاوية المطلوبة.

Keywords


Article
Articular Cartilage Surface Topography and Roughness in Frozen Tissue Samples Using Optical Coherence Microscopy
طبوغرافيا وخشونة سطح غضروف مفصلي لعينات أنسجة مجمدة باستخدام طريقة التماسك البصري المجهري

Author: Sadiq Jafer Abbass صادق جعفر عباس
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2016 Volume: 19 Issue: 1 Pages: 166-171
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

This paper describes a method to visualize the topography of the surface of cartilage. Optical Coherence Microscopy (OCM) technique has been used to get two dimensional images of frozen tissue samples of bovine articular cartilage. Optical Coherence Microscopy (OCM) is a combination of optical coherence tomography and confocal microscopy. Coherence gate from OCT and confocal gate from confocal microscopy can achieve higher resolution and deeper penetration depth. The precise three-dimensional topography of the cartilage surfaces has been obtained. The full-image roughness, for frozen samples has been obtained.

يوضح هذا البحث استخدام طريقة لتصوير تضاريس سطح الغضروف. حيث استخدمت تقنية التماسك البصري المجهري (OCM) للحصول على صور ثنائية الأبعاد من عينات لأنسجة مجمدة من غضروف بقري مفصلي.ان التماسك البصري المجهري (OCM) هو مزيج من التصوير المقطعي للتماسك البصري والفحص المجهري متحد البؤر. بوابة التماسك من طريقة التماسك البصري المجهري وبوابة مبائر من الفحص المجهري متحد البؤر يمكن تحقيق دقة أعلى وعمق أكبر للاختراق. تم الحصول على تضاريس دقيقة ثلاثية الأبعاد لسطح الغضروف. تم الحصول على صورة كاملة لخشونة سطح العينات المجمدة


Article
A BiomechanicalModel Study of the Rat as a Medial Collateral Ligaments of the Knee
دراسة ميكانيكية حيوية في الجرذ كنموذج للروابط الأنسجة الجانبية للركبة

Authors: Fakhir Salman --- Sadiq Jafer Abbass --- Noor Ali Sadek
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 9 Pages: 1593-1610
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Ligament primarily stabilizes the diarthrodial joints and function to providestability and support during the motion of diarthrodial joints. These functions areassisted by the congruent geometry of the articulating joint surfaces andmusculotendinous forces. Ligament exhibits viscoelastic, or time-dependentbehavior, like many tissues in the body. From the medical point of view anunderstanding of the biomechanics of ligaments are crucial for the understandingof injury mechanisms and to evaluate existing surgical repair techniques. The modeof failure in ligaments depends strongly on the rate of loading. Thus, ligamentviscoelasticity is an important determinant of tissue response to loading, andviscous dissipation by the tissue modulates the potential for injury. Manymathematical models have been developed to describe the complexity of thesebehaviors that could include the microphysical interactions of various constituentsbut none of them seems to represents the overall properties of these structures.Models can be an important tool in understanding tissue structure-functionrelationships and elucidating the effects of injury, healing, and treatment. The mainobjective of this work is to study from the biomechanical point of view, thebehaviour of an example of the medial collateral ligament in response to stress andstrain effects to evaluate the biological behaviour of the ligament. The strain effectas example of the modified superposition method and analyze the results and themodel that can express the medial collateral ligament behaviour

تعد الروابط من الأنسجة الحيوية التي تعمل على تثبيت عظام المفاصل الزلالية , و وظيفتهاالأساسية تثبيت ودعم هذه المفاصل اثناء الحركة . هنالك بعض العوامل التي تدعم الرابط لأداءوظائفه منها التناسق في شكل العظام في منطقة التقائها عند المفصل و قوة العضلات المتصلةيعتمد على الزمن (viscoelastic behaviour) بالمفصل. و للروابط سلوك لزوجة مرنة كمعظم الانسجة الحية. من وجهة النظر الطبية فانه من الضروري فهم الميكانيكية الحيويةللروابط لفهم ميكانيكية حدوث الجروح وايجاد التقنيات الجراحية البديلة. ان الفشل الذي يحدث فيالرابط يعتمد بصورة كبيرة على معدل تحميل القوة. لهذا فان خاصية اللزوجة المرنة تعطينظرة مهمة عن استجابة النسيج لتحميل القوة وكيفية تجنب الجروح. ولهذه الأهمية تم تطويربعض النماذج الرياضية لوصف و فهم عمل الروابط من الناحية الوظيفية و التركيبية. يهدف هذاالعمل دراسة الناحية الميكانيكية الإحيائية كمثال للرابط الموجود على الناحية الداخلية لمفصلالركبة واستجابته لتأثير الإجهاد و المطاوعة, ثم تطبيق النموذج الرياضي لوصف و تحليلالنتائج.


Article
Effects of Backpack Loads on Kids Posture

Authors: Sadiq Jafer Abbass --- Duha Qais Abd-ul-Amir
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 4 Pages: 876-886
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Kids carrying heavy loads as a part of everyday activity may be related to bend their trunks forward to maintain body posture and balance while walking. This study was to determine a correlation between the weight of a child's backpack, their body weight, and certain features of their body posture. The study group consisted of 6 children, in age of primary school. The anthropometry (age, length, weight) were taken for each volunteers. A school backpack was specially built for the present study. Walking gait was filmed in three cases: (zero kg, 3 kg and 6 kg) backpack.Posture was analyzed by using (Kenova and MATLAB) computer programs.The results show that the forward inclination of the trunk increases when the load and the walking distance are increased, this forward inclination segment may impose greater stress over the vertebral column (ligaments and intervertebral disks) and increase the risk of back problems. Spine and back health may be adversely affected by load carriage and it may be important to use spinal curvature as a measure of posture for load carriage. This study shows that the backpack load cause a lumbar asymmetry by 10 to 20 degree according to the load which has a significant amount of back pain in kids.

الاطفال اللذين يحملون أحمال ثقيلة كجزء من نشاطاتهم اليومية من الممكن ان تؤدي الى إنحناء ابدانهم الى الأمام للمحافظة على هيئة الجسم والتوازن اثناء المشي. هذه الدراسة كانت لتحديد العلاقة المتبادلة بين وزن حقيبة الظهر للأطفال، مع وزن أجسامهم وتعيين الملامح لوضعية أجسامهم. تمت الدراسة بالاستعانة بستة أطفال متطوعين طبيعيين في مرحلة الدراسة الابتدائية، تم حساب الانثروبومترية (العمر والطول والوزن) للمتطوعين. تم اختيار حقيبة الظهر المدرسية لهذه الدراسة. تم تصوير خطوات المشي من المستوي الجانبي لثلاث حالات هي (صفر كغم و3 كغم و6 كغم) لحقيبة الظهر. تم تحليل وضعية الجسم باستخدام برنامجي الحاسوب (كينوفا وماتلاب). أظهرت النتائج زيادة في الأنحناء للأمام لجذع الجسم عند ازدياد الثقل ومسافة المشي، وهذا الأنحناء يفرض إجهاد عالي على العمود الفقري (الأربطة والأقراص الفقرية) والتي بدورها تزيد من خطر الإصابة بمشاكل الظهر. بينت الدراسة أن حمل الثقل يؤثر سلباً على العمود الفقري وصحة الظهر، ومن المهم استخدام انحناءات العمود الفقري لقياس وضعية

Keywords

posture --- spine --- gait analysis --- back pain --- kids.

Listing 1 - 10 of 12 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (12)


Language

English (7)

Arabic and English (4)


Year
From To Submit

2017 (1)

2016 (1)

2013 (2)

2012 (4)

2011 (2)

More...