research centers


Search results: Found 9

Listing 1 - 9 of 9
Sort by

Article
Variation of Soil Temperature with Time and Depth in Karbala Region
تغير درجة حرارة التربة مع الوقت والعمق في منطقة كربلاء

Authors: Talib R. Abbas --- Rajaa R. Abbas
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2009 Volume: 7 Issue: 3 Pages: 170-175
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

A theoretical investigation of factors affecting soil temperature variation with time and depth is presented. Annual soil temperature variation with time and depth declares that there is a considerable temperature variation in the upper few meters that is necessary to several application fields include agriculture, civil engineering, and environmental engineering. One-dimensional mathematical model is used to study the annual soil temperature variation. The model solution was calibrated with soil temperature measurements at Karbala region. The calibrated mathematical expression is a useful mean to describe the soil temperature variation with time and depth in Karbala region. Results show that at depth below about six meter the soil temperature is approximately constant.

تم في هذا البحث إجراء دراسة نظرية للعوامل المؤثرة في تغير درجة الجرارة داخل التربة مع العمق والزمن. اظهر التغير السنوي لدرجة حرارة التربة مع العمق والزمن إن هناك تغييراً مؤثرا في درجة الحرارة في بضعة الأمتار القليلة العليا من التربة وان هذا التغير مهم لعدة مجالات بضمنها الزراعة والهندسة المدنية والبيئية.تم اعتماد نموذج رياضي في بعد واحد لدراسة التغير السنوي لدرجة الحرارة داخل التربة. تمت معايرة نتائج الموديل الرياضي مع قياسات لدرجة حرارة التربة في منطقة كربلاء. يمثل التعبير الرياضي الناتج من هذه الدراسة أداة مفيدة للتعبير عن تغير درجة الحرارة مع الزمن والعمق في منطقة كربلاء. أظهرت النتائج أن درجة الحرارة في هذه المنطقة تبقى ثابتة على طول السنة عند عمق من ستة أمتار وأكثر من سطح التربة.


Article
Non-Isothermal Modeling Of Soil Vapor Extraction System Including Soil Temperature Effect

Authors: Talib R. Abbas --- Rafa'a H. Al-Suhaili
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2007 Volume: 13 Issue: 1 Pages: 1253-1265
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Soil vapor extraction (SVE) is a proven effective in-situ technology for the removal of volatile organic compounds (VOCs) from the subsurface. SVE process is highly sensitive to temperature. Studying annual soil temperature variation with depth declares that there is a considerable temperature variation in the upper few meters that may affect the overall efficiency of SVE process.A numerical model was developed to aid in investigation of field-scale soil vapor extraction process. The model is three-dimensional, time dependent that simulates nonisothermal vapor flow and transport of multicomponent mixtures in soil and keeps track of the distribution of each compound in the other three immobile phases (NAPL, aqueous, and sorbed). Rate limited interphase mass transfer with linear driving force expressions were used to model volatilization of oil into gas phase. A local equilibrium partitioning was assumed between gas, water, and solid phase. The model equations were discretized using a standard Galerkin finite element method and solved using set iterative solution algorithm.Simulation of hypothetical field-scale problems was done. The physical domain described a three-dimensional system with flow to a single extraction well. A hypothetical soil temperature variation with depth was incorporated with the model. The result of these simulations showed that this temperature variation has a considerable effect on system efficiency and may play a role in optimum system configuration.

تعتبر عملية استخلاص بخار التربة تكنولوجيا موضعية مثبتة الكفاءة لازالة المركبات العضوية المتطايرة من المنطقة غير المشبعة من التربة. ان هذه العملية حساسة جدا لدرجة الحرارة. من دراسة التغير السنوي لدرجة حرارة التربة مع العمق تبين بأن هنالك تغير حراري لابأس به في الأمتار القليلة العليا من التربة والذي من الممكن أن يؤثر على الكفاءة الكلية لهذه العملية.تم تطوير نموذج عددي للمساعدة في دراسة عملية استخلاص بخار التربة وضمن الأبعاد الحقلية. وهو نموذج ثلاثي الابعاد و معتمد على الزمن والذي يحاكي الجريان و الانتقال متغير الحرارة لأبخرة مخلوطات المكونات المتعددة في التربة مع متابعة توزيع كل مكون في الاطوارالثلاثة الاخرى غيرالمتحركة (الزيتي والمائي و الممتص). تم استعمال نموذج انتقال الكتلة بين طورين ذو المعدل المحدود مع تعبير خطي للقوة الدافعة لنمذجة تطاير الزيت الى الطور الغازي مع افتراض اتزان موقعي لتوزيع الملوث بين الاطوار الثلاثة الغازي والمائي والصلب. حلت معادلات النموذج عدديا وبثلاثة ابعاد باستعمال طريقة العناصر المحدودة التقليدية standard Galerkin finite element methodوباستعمال خوارزمية set-iterative. تمت محاكاة عمليات استخلاص بخار التربة بابعاد حقلية يصف المدى الفيزيائي فيها منظومة ثلاثية الابعاد ووجود جريان بأتجاه بئر سحب واحد. تم ادماج تغير حراري افتراضي للتربة مع النموذج العددي. أظهرت نتائج المحاكات التأثير المهم للتغير الحراري للتربة على كفاءة المنظومة وبينت انها قد تلعب دورا في تحديد الشكل الامثل والابعاد المثلى للمنظومة.


Article
Theoretical Investigation of Pneumatic Soil Vapor Extraction

Authors: Inmar N.Ghazi --- Muhammad A. Abdul-Majeed --- Talib R. Abbas
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 1 Pages: 96-109
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Pneumatic Soil Vapor Extraction (SVE) is a new remediation techniquetargeting to improve removal of Volatile Organic Compounds from low permeableareas in heterogeneous soil settings in unsaturated zone. In contrast to traditional SVE,in which soil vapor is extracted continuously by a vacuum pump, pneumatic SVE isbased on enforcing a sequence of large pressure drops on the system to enhance therecovery from the low-permeable areas to enhance removal from areas subject todiffusion limitation. This technique has been shown to be promising at laboratoryscale.A one-dimensional mathematical model was used to study governing factorsand to clarify and quantify the mechanisms responsible for enhanced contaminantremoval during this process. From analytical solution it is clear that the gas phaseinside low permeable area moves with sinusoidal velocity whose amplitude decreaseswith depth. Two zones can be distinguished. First in which the gas phase can reach thehigh permeability area and continuously mixed with clean air, the enhanced removalmechanism is advection. The depth of this zone may range from .05m to .6m. Secondis in which there is no net contaminant advection, the enhanced removal mechanism ishydrodynamic dispersion. The hydrodynamic dispersion coefficient may reach a valuerange from 7 to 700 times the effective molecular diffusion coefficient. In the absenceof non-aqueous phase liquid in the first zone, it can be considered a clean conductivezone and impose no transport resistance on the second zone (i.e. mathematically, theupper boundary can be lowered just below the first zone).The model was tested by comparing its results with experimental resultspublished by a previous study. Overall, comparisons appear to be reasonably good.Investigation shows that pneumatic SVE is promising at field setting. In order for thistechnique has significant removal enhancement the gas phase permeability in the lowpermeability region should be at least on order of 1*10-12 m2 (1 darcy).


Article
Flow Zones In Unsaturated Soil Due To Barometric Pumping
مناطق الجريان في التربة غير المشبعة بفعل الضخ الجوي

Authors: Talib R. Abbas --- Muhammad A.Abdul-Majeed --- Inmar N.Ghazi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 10 Pages: 1900-1909
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The study of gas flow in unsaturated soil is important for better modeling ofvolatile organic compounds (VOCs) transport. A gas flow in unsaturated soil can beinduced naturally by the atmospheric pressure fluctuation. Oscillations in barometricpressure are both diurnal, corresponding to daily heating and cooling of theatmosphere, and of longer time periods, resulting from the passage of weather fronts.Daily variations will average about 4 to 5 mbar while those due to weather frontpassage can be 25 mbar or more.A one-dimensional conceptual model was used to investigate the advectivegas flow zones in the subsurface induced by the natural atmospheric pressurefluctuation. From analytical solution, it is clear that the gas phase inside unsaturatedzone moves with sinusoidal velocity whose amplitude decrease with depth. Two zonescan be distinguished. First in which the gas phase can reach the soil surface andcontinuously mixed with clean air. The depth "Penetration Depth" of this zone mayrange from 0.05m to 0.8m. Second is "Oscillation Zone" in which the air oscillatesaround its original position but still remains in the soil. Maximum air displacementtoward the upper boundary may reach 0.24m when the depth of the lowerimpermeable boundary is 10m. This displacement is more as the lower impermeableboundary is deeper. The mixing of air above penetration depth with clean air abovesoil surface and the oscillation of air below penetration depth may have a significanteffect on natural VOCs transport and fate in the soil region within these depths.

أن دراسة جريان الغاز في التربة غير المشبعة مهمة للوصول الى نمذجة رياضيةأفضل لأنتقال المركبات العضوية المتطايرة. اذ يحصل جريان غاز في التربة غير المشبعةوبصورة طبيعية نتيجة التذبذبات في الضغط الجوي. حيث يحصل التذبذب في الضغط الجويعلى نمطين، الأول تذبذب يومي يناغم التسخين والتبريد اليومي للهواء الجوي، والثاني تذبذببفترات اطول ناتجا من مرور منخفظات أو مرتفعات ضغط جوي. يتراوح التذبذب اليومي5 ملي بار، في حين ممكن أن يصل التذبذب الناتج من مرور – للضغط الجوي حوالي 4منخفظات أو مرتفعات ضغط جوي الى 25 ملي بار أو أكثر.تم اعتماد نموذج رياضي ذو بعد واحد لدراسة جريان الغاز تحت سطح التربة متأثرا بتذبذباتالضغط الجوي. يوضح الحل التحليلي للنموذج الرياضي أن الطور الغازي في المنطقة غيرالمشبعة من التربة يتحرك بسرعة جيبية تتناقص سعتها مع العمق. ويمكن تمييز منطقتين،الأولى يمكن للغاز الوصول الى سطح التربة ويختلط وبصورة مستمرة مع الهواء النظيف ويبلغ سمك هذه المنطقة من 0.05 الى 0.8 متر، والثانية والتي يتذبذب فيها الهواء حولموقعه الأصلي ويبقى داخل التربة. اذ من الممكن أن تصل سعة التذبذب في هذه المنطقة الى0.24 متر عندما يكون عمق الحدود غيرالنفاذه السفلى 10 متر. وتزاد سعة التذبذب هذه كلماكان عمق الحدود غير النفاذه اكبر. أن اختلاط الهواء في المنطقة الأولى مع الهواء النظيففوق سطح التربة وتذبذب الهواء في المنطقة الثانية ممكن أن يكون له تأثيرذو قيمة علىالأنتقال الطبيعي للمركبات العضوية المتطايرة في التربة ضمن هاتين المنطقتين.


Article
Testing the Applicability of Submerged Hollow Fiber Membrane Bioreactor (MBR) Technology for Municipal Wastewater Treatment in Iraq
أختبار تطبیق تقنیة المفاعلات البیولوجیة ذات أغشیة الألیاف المجوفة لمعالجة میاه الصرف الصحي في العراق

Authors: Talib R. Abbas --- Mohammed A. Abdul-Majeed --- Inmar N.Ghazi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 19 Pages: 3467-3473
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Operation of a one module hollow fiber submerged type MBR system wastested in this work. The system was operated at fixed permeate flowrate of 12 l/hr.The hydraulic retention time of the aeration tank was about 8.3 hr. The mixedliquor suspended solid (MLSS) concentration was maintained in the range 5000-5500 mg/l. The results show the workability of this system under Iraqi conditionswithout any difficulties. About 85% chemical oxygen demand (COD) removalwas achieved. The value of turbidity is well below 0.61 NTU throughout theoperation time.

ت م ف ي ھ ذا العم ل أختب ار منظوم ة معالج ة می اه ص رف ص حي بأس تعمال تقنی ة المف اعلاتالبیولوجیة ذات الأغشیة. تم أستعمال قطعة غشاء واحدة غاطسة نوع الالیاف المجوفة. تم تشغیلالمنظومة بمعدل جریان ثابت للماء النافذ عب ر الغش اء وبح دود 12 لت ر/س اعة. ك ان ال زمن البق اءالھیدرولیكي للماء داخل خزان التھوی ة بح دود 8.3 س اعة. ت م الحف اظ عل ى تركی ز الم واد العالق ة5500 ملغم/لتر. أظھ رت النت ائج عم ل ھ ذه - الصلبة للماء في خزان التھویة ضمن المدى 5000التقنیة وفي الظروف العراقیة وبدون مشاكل. بلغ ت نس بة الأزال ة لمتطل ب الأوكس جین الكیمی اوي.NTU بحدود 85 %. وكانت قیمة العكورة خلال فترة التشغیل أقل من 0.61


Article
Removal of a Single-Component NAPL under Nonequilibrium Condition: a Zero Mass Flux Moving Boundary
ازالة السائل ذو الطور اللامائي والمركب الواحد تحت ظروف عدم الأتزان: ظروف حدودية متحركة ذات تدفق كتلي صفري

Authors: Talib R. Abbas --- Mohammed A. Abdul-Majeed --- Inmar N.Ghazi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 8 Part (A) Engineering Pages: 2096-2105
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A new zero flux moving boundary conditions to solve the non-equilibrium single-component dispersion-advection transport problem containing NAPL have been introduced. The resultant model can overcome many approximations in the model which is done by previous study and give more precise analytical solution to the aqueous (or gas) phase concentration profile, NAPL saturation and the moving front speed. From the results, it is clear that the number of pore volumes (P), which are required for removing all NAPL under equilibrium conditions, plays a role in the differences between the two models' predictions. The NAPL saturation profile predicted by the two models is the same. At very low P the predicted value of the front speed by the present model is half of the value predicted by Brouwers and Augustijn model and increases gradually with P. It reaches 0.99 when P is 100.

تم أعتماد ظروف حدودية متحركة ذات تدفق كتلي صفري للحل الرياضي لمسألة الحمل-الأنتشار ولمركب واحد وتحت ظروف عدم الأتزان. يتجاوز الموديل الرياضي الناتج عدة تقريبات للحل الذي تم في دراسة سابقة. ويعطي حل تحليلي ادق لتركيز الطور المائي (الغازي) وكذلك لتركيز الطور السائل اللامائي وسرعة تقدم الجبهه المتحركة. تشير النتائج الى ان P ،عدد مرات حجم الفراغات في التربة من المائع النظيف واللازمة لأزالة كل الطور السائل الامائي وتحت ظروف الأتزان، يلعب دورا في الأختلافات بين تنبؤات كل من الموديلين. يعطي كلا الموديلين حلا متشابها لتركيز الطور السائل اللامائي. عند القيم الصغيرة جدا الى P فأن سرعة الجبهه التي يعطيها الحل في هذا البحث هي نصف القيمه التي يعطيها الحل السابق وتزداد هذه النسبة مع زيادة قيمة P. تصل قيمة هذه النسبة 0,99 عندما تكون قيمة P 100.


Article
Modeling the Effect of Operation Temperature on Characteristics of Rosen Type Piezoelectric Transformer
نمذجة تأثير درجة حرارة العمل على خصائص محولة كهروضغطية نوع روزين

Authors: Nabil N. Rammo --- Rajaa R. Abbas --- Talib R. Abbas --- Inmar N. Ghazi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 20 Pages: 6074-6083
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A simplified lumped model that makes direct correlation between Rosen'spiezoelectric transformer (PT) dimensions and material properties via equivalentcircuit parameters was studied. The model calculation of the resonancecharacteristics and voltage gain was associated with changes in operatingtemperatures from 50°C to 70°C. It is found that for different load resistors, theresonance frequencies are shifted by less than 1.6% their normal values uponraising the operation temperature to 70°C, whereas the sensitivity of voltage gainis better at higher load resistors.Each of the elastic compliances SE11, SE33 and SD33 of the PT material due to theirtemperature dependency cause the resonance frequency to shift below and abovethe normal value by less than 1% for very slight change in voltage gain in eachcase. The overall balance between mechanical parameters may play role in theoptimum stability of the voltage gain.

تمت دراسة نموذج ریاضي مبسط یربط وبعلاقة مباش رة بین أبعاد محولة كھروضغطیة نوع روزین ومواصفات مادة المحولة مع مكونات دائرة كھربائیة مكافئة. استعمل النموذج لدراسة التصرف الرنیني وربح 70 . بینت الدراسة ولقیم ˚C 50 الى ˚C الفولتیة للمحولة عند تغیر درجة حرارة عمل المحولة منمختلفة لمقاومة الحمل، ان الانحراف في قیمة ترددات الرنین للمحولة لا تزید عن 1.6 % عن 70 وأن حساسیة ربح الفولتی ة ˚C 50 عند ارتفاع درجة حرارة عمل المحولة الى ˚C قیمتھا في للحرارة تكون أفضل لقیم مقاومة الحمل العالیة. SE نظرا لأعتماد قیمة كل من ثوابت المرونة S 11 و ES 33 و D 33 لمادة المحولة على درجة الحرارة 50 بمق دار لا یزی د ˚C فأن تأثیركل منھا یؤدي الى انحراف تردد الرنین أقل أو أكثر من قیمتھ عندعن 1% مع تغیر ضئیل في ربح الفولتیة في كل حالة. ان الموازنة بین تأثیرك لمن ھذه الثوابت یمكن أن یلعب دوراً في تحقیق الاستقراریة المثلى لربح الفولتیة.


Article
Use of Membrane Bioreactor for Medical Wastewater Treatment
استخدام الأغشية الغاطسة في المفاعل الحيوي لمعالجة مياه الصرف الصحي المطروح من المستشفيات

Authors: Mohammed Ali I. Al-Hashimi --- Talib R. Abbas --- Yaser I. Jasem
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 3 Part (A) Engineering Pages: 720-730
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this study, a lab scale modified Ludzack-Ettinger (MLE) type submerged membrane bioreactor (MLE-type MBR) system is studied to treat a hospital wastewater to remove organic matter as well as nitrogen. During the operation period, the BOD5 and COD removal efficiency is higher than 98 and 90%, respectively regardless of the fluctuation in influent quality. In addition, the results show excellent removal of nitrogen, pathogen and TSS with average of 96, 98.33 and 99.5%, respectively. The MLE-MBR system produces high quality effluent which can achieve the Iraqi limits for irrigation purpose for all measured parameters.

في هذه الدراسة, تم اختبار نظام الأغشية الغاطسة في المفاعل الحيوي (هوائي محدد) لمعالجة مياه الصرف الصحي من المستشفيات من خلال إزالة المواد العضوية إضافة" إلى النتروجين. خلال فترة العمل كانت كفاءة الإزالة لكل من الأوكسجين المطلوب حيويا" والأوكسجين المطلوب كيميائيا" تزيد على 98 و 90% على التوالي, بغض النظر عن التذبذب في نوعية المياه الواردة. كما وأظهرت النتائج نسب إزالة ممتازة لكل من النتروجين, الأحياء المسببة للأمراض و المحتوى الكلي للمواد الصلبة وبمعدل نسبة إزالة تساوي96, 98,33 و 99,5% على التوالي. إن نظام الأغشية الغاطسة في المفاعل الحيوي (هوائي محدد) ينتج ماء بنوعية ممتازة يستطيع من خلالها تحقق حدود المواصفة العراقية الخاصة بالمياه المكررة لإغراض الري ولجميع المعايير المقاسة.


Article
Performance of Aerobic Granular Sludge Bioreactor Seeded with Flocculated Activated Sludge From an Iraqi Municipal Wastewatere Treatment Plant
أداء المفاعل البيولوجي الهوائي ذو الحمأة المنشطة الحبيبية والمبذور بحمـأة منشطة متكتلة من أحدى محطات معالجة الصرف الصحي العراقية

Authors: Talib R. Abbas --- Majid A. Dixon --- Mohammed A. Abdul-Majeed --- Inmar N.Ghazi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 6 Part (A) Engineering Pages: 1462-1472
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Aerobic granular activated sludge is an attractive and promising process for intensive and high-rate biological nutrient removal (BNR) and secondary clarification in a single reactor.This work reportsthe performance of aerobic granular sludge sequential batch reactor (SBR) seeded with flocculated activated sludge collected from an Iraqi municipal wastewater treatment plant, using synthetic wastewater. The conditions under which the successful cultivation of aerobic granular sludge was done are as follows: influent chemical oxygen demand (COD) was 1100 mg/l, volumetric exchange rate was 50%, aeration time was 10 hr, anoxic time was 2 hr aerationand sludge settling time was about 0.5 min. After 90 days, the dominant granules size was 1.5-3.5 mm. The granules became regular in shape with smooth surface, sharp boundaries and compact in structure. The biomass concentration in the reactor in terms of MLSS was 4100 mg/l. Sludge volume index (SVI) was 60 ml/g. High syntheticCOD removal and simultaneous nitrification and denitrification during aerobic phase was observed. Subjection of themature granules to a low COD municipal wastewater the activity of the granules was significantly reduced.

تعتبر تقنية الحمأة المنشطة الحبيبية من التقنيات المؤملة وذات الكفاءة العالية في أزالة المغذيات بايولوجيا من المياه وعمل الترسيب الثانوي وفي حيز واحد. بين هذا البحث التعرف على أداء المفاعل البايولوجي المتعاقب ذو الحمأة المنشطة الحبيبية. والذي غذي عند البدء بحمأة منشطة جلبت من أحدى المنظومات التقليدية لمعالجة مياه الصرف الصحي في مدينة بغداد. وقد أستخدامت مياه ذات مغذيات أصطناعية في هذا العمل. تتلخص الظروف التشغيلية والتي تم فيها الحصول بنجاح على حمأة منشطة حبيبية هي كالاتي: تركيز متطلب اوكسجين كيمياوي في الماء الداخل بحدود 1100 ملغم/لتر، نسبة مئوية للأستبدال الحجمي للماء في المفاعل البايولوجي وفي كل دورة 50%، فترة تهوية 10 ساعة، فترة هوائية محددة 2 ساعة، فترة ترسيب بحدود 0,5 دقيقة. كان الحجم السائد للحبيبات، وبعد حوالي 90 يوما من بدأ عمل المفاعل البايولوجي، ضمن المدى 1,5 – 3,5 ملم. كانت الحبيبات الناتجة منتظمة الشكل وواضحة الحواف وذات سطح أملس وتركيب مكتنز. كان تركيز المواد الحية وبدلالة تركيز المواد العالقة الكلية بحدود 4100 ملغم/لتر. وكان مؤشر حجم الحمأة بحدود 60 ملغم/لتر. تمت ملاحظة الكفاءة العالية لأزالة متطلب الأوكسجين الكيمياوي وتزامن عمليتي النترجة وأزالة النتروجين في فتر التهوية. أن تعريض الحمأة الحبيبية الناتجة من هذا البحث الى مياه صرف صحي حقيقية أدى الى انخفاض في فعاليتها.

Listing 1 - 9 of 9
Sort by
Narrow your search

Resource type

article (9)


Language

English (9)


Year
From To Submit

2015 (1)

2014 (2)

2012 (1)

2011 (1)

2010 (2)

More...