research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Experimental Comparative Study on the Performance of Single and Multi-Stage Dry Air Filters
دراسة عملية لمقارنة اداء المرشحات الأحادية وثنائية المراحل

Authors: Abdul- Kareem R. Abed --- Ahmed Q. Ahmed --- Ammar F. Khudaier --- Thabet C. Yassen
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 8 Part (A) Engineering Pages: 1508-1520
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

An experimental study on the effect of filter types, relative humidity and using two stage filters on the weight efficiency and pressure drop across the filter was carried out, to complete the study a test rig is designed and built, the rig consist of three sections air duct, of 30 cm ×30 cm cross sectional area, with overall length of 220 cm. Six types of air filters are used in a single stage filters; namely spongy, polyester, synthetic one and two layer aluminum filters. A molten Aluminum powder dust (Type Aluxite No. 25, 98% less than 35 microns and 2% less than 10 microns) is used. In two stage filters study the bag filter is used as a secondary filter while the primary can be any type of the five filters mentioned above. The study shows that the spongy filters gives a maximum efficiency when is used as a single stage filter as compared with the other filters type. Increasing of working environment relative humidity improves the weight efficiency for both single and two stage filters. Two stage filters can improved the filtration process, it is found that the combination of spongy filter and bag filters give a maximum of weight efficiency of about 92% when the relative humidity equals to 90% . Space distance between two stage filters affect the weight efficiency, it is found that the best distance between the spongy filter and bag filter is between 15 to 20 cm.

أجريت عمليا دراسة تأثير نوع مرشح الهواء الأحادية والثنائية المراحل ورطوبة المحيط النسبية على كفاءة المرشح الوزنية وهبوط الضغط خلال المرشحات. تم تصميم وبناء جهاز مختبري يتكون من مجرى هواء بأبعاد 30 cm × 30 cm ويتكون مجرى الهواء من ثلاثة مقاطع وبطول كلي يساوي 220 cm. أجريت الدراسة على خمسة أنواع من المرشحات كمرشحات أحادية المرحلة هم المرشحات الأسفنجية و البوليستيرية والصناعية والمرشحات المصنوعة من الألمنويم احادية وثنائية الطبقة. أستخدم غبار قياسي )من نوع Alxite No.25 والمتكون من غبار الالمنيوم 98% بقطر اقل من 35 micronsو 2% بقطر يساوي (10 microns. في المرشحات ثنائية المراحل استخدم المرشح الكيسي كمرشح ثانوي دائما في حين ان المرشحات المذكوره اعلاه استخدمت كمرشحات رئيسة.بينت الدراسة أن المرشح الاسفنجي يتميز بأعلى كفاءة وزنية عند استخدامه في مرحلة ترشيح احادية. وكذلك أن زيادة الرطوبة النسبية تحسن من كفاءة المرشحات لكلا مرحلتي الترشيح. وكذلك تبين ان مرحلتي الترشيح تزيد من كفاءة الترشيح،واعطى المرشح الاسفنجي- المرشح الكيسي أعلى كفاءة وبمقادر 92% عندما كانت الرطوبة النسبية تساوي 90%. وكذلك اتضح ان المسافة بين المرشحين في مرحلتي الترشيح لها تأثير واضح على الكفاءة الوزنية، وكانت افضل مسافة بين المرشحين بحدود15-20 cm.


Article
EXPERIMENTAL STUDY ON THE EFFECT OF CAPILLARY TUBE GEOMETRY ON THE PERFORMANCE OF VAPOUR COMPRESSION REFRIGERATION SYSTEM
دراسة عملية لبيان تأثير شكل الأنبوب الشعري على معامل اداء منظومة تثليج دورة انضغاطية

Loading...
Loading...
Abstract

A domestic refrigerator of 5 ft3 capacity is used to study the effect of coiled diameter and pitch distance of a capillary tube. Five capillary tubes of 2 mm in diameter and 1500 mm length each are used, as same as original capillary tube of the refrigerator. The capillary tubes is formed in five shapes, each one has different coil diameter (D) namely 25, 50, 75, 100 and 125 mm in diameter, in addition three distances between each coil (pitch (P)) is tested, namely 6, 8 and 10 mm. The pressure at inlet and outlet of capillary are measured to calculate the cycle COP, as well as the power consumed by the cycle compressor is measured to calculate the mass flow rate of refrigerant. The work show that the coiled diameter of capillary tube affect the cycle COP strongly, as the capillary coiled diameter (D) increases from 25 to 100 mm the cycle COP increases from 2.8 to 3.7 when the cabinet temperature equals to 8oC. The increases of coiled diameter more than 100 mm shows insignificant effect on the cycle COP. While the pitch space of capillary tube coiled shows minor effect on the cycle COP. Moreover, to the mass flow rate of refrigerant increases with approximately ranges from 1.2-2.7 g⁄s as the capillary coiled diameter increases from 25 to 125 mm when the cabinet temperature equals to 8o C. Also; there are directly proportional between the temperature of evaporator cabinet from 2-8 o C with mass flow rate of refrigerant from 1.9-2.4g⁄s when capillary coiled diameter 100 mm.

تم دراسة تأثير قطر لفة الأنبوب الشعري وكذلك الخطوة بين لفة وأخرى على معامل إداء ثلاجة منزلية سعة 5 قدم ، واستخدمت خمسة أنابيب شعرية قياس كل منها يساوي قياس الأنبوب المستخدم في الثلاجة أصلا، وكان قطر الأنبوب 2 ملم وطول 1500 ملم. شكلت الأنابيب الشعرية للحصول على خمسة أشكال من الأنابيب تختلف بقطر اللفة (D)، حيث تم دراسة خمسة أقطار من اللفات تتراوح من 25 الى 125 ملم بخطوة تساوي 25 ملم. أضافة الى ذلك تم دراسة تأثير المسافة بين لفة وأخرى (P) على معامل أداء الثلاجة وكانت المسافات المدروسة تساوي 6 و 8 و 10 ملم. بينت الدراسة ان قطر اللفة (D) يؤثر بشكل كبير على معامل أداء الثلاجة حيث لوحظ زيادة في معامل أداء الثلاجة من 2,8 الى 3,7 عند زيادة قطر اللفة من 25 الى 100 ملم عندما كانت درجة حرارة المقصورة 8 درجة مئوية ، في حين ان زيادة قطر اللفة اكبر من 100 ملم لا يؤثر بشكل كبير على معامل الأداء. ولوحظ تاثير بسيط على معامل اداء الثلاجة عند تغيير المسافة (P) بين لفة وأخرى. أضافه الى ذلك حصلت زيادة في المعدل التدفق الكتلي بمعدلات تقريبية من 1.2-2.7 غمثانية لمائع التثليج عند زيادة قطر اللفة من 25 الى125 ملم عندما كانت درجة حرارة المقصورة 8 درجة مئوية. ايضا لوحظ وجود علاقة طردية بين درجة حرارة مقصورة التبريد من 2-8 درجة مؤوية مع معدل التدفق الكتلي لوسيط التبريد من1.9-2.4 غمثانية عند كان قطر اللفة 100ملم.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2014 (1)

2013 (1)