research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Exergy Analysis and Thermodynamic Model for Reciprocating and Scroll Compressors Used in an Air Conditioning Packaged Unit
تحليل للطاقة المتاحة مع نموذج ثرموديناميكي للضواغط الترددية و الاوربيتالية في وحدة تكييف مجمعه

Loading...
Loading...
Abstract

An exergical thermodynamic model was used to analyze and optimize reciprocating and scroll compressors of an air condition packaged unit. The experimental work was carried out using 3.0 TR packaged unit manufactured by Carrier Company. The experimental and the analysis show that the exergy dissipative due to friction losses in bearings, suction and discharge valves and the transformation of power are larger than the heat losses. The exergy efficiency for the compressor was varying between (60-68) %. The scroll compressor was found to be better than the reciprocating compressor at an environmental temperature of 35℃ due to its low total losses which is 10% less than the reciprocating compressor ones . The heat losses percentages were 3% for scroll and 2% for the reciprocating of the total power input. The thermodynamic model has shown to be reliable in dealing with a change in the environmental temperatures and such system components and size.

تم استخدام موديل ديناميكي حراري باستخدام مبدأ الطاقة المتاحه ( Exergy) لتحليل وتحديد أداء نوعين من الضواغط الأول ترددي والأخر اوربيتالي ,مثبتين في جهاز تكييف سعة 3طن تبريد مصنع من قبل شركة Carrier . بينت النتائج التحليلية والمختبرية ان خسائر الاحتكاك اكبر من الخسائر الحرارية. وان الكفاءة الحرارية المتقدمة تتراوح بين 60-68 %. وجد ان الضاغط الاوربتالي أفضل من الضاغط الترددي عند درجة حرارة جو قدرها 35 م بسبب قلة خسائره بمقدار 10% مقارنة بالضاغط الترددي. تبين ان الخسائر الحرارية للضاغط الاوربتالي تمثل 3% من الطاقة الكهربائية الكلية المجهزة و 2% للضاغط الترددي. ووجد ان التحليل الحراري المتقدم كان نافعا ومرنا في التعامل مع تغيير درجة حرارة الجو ومع مكونات وحدة التكييف وحجمها.


Article
Effect of Recirculation Ratio on the Uniformity Flow in a High Area Ratio of Outlets Pipe at Different Entrance flow rates
تأثير نسبة إعادة التدوير على توحيد التدفق في انبوب متعدد المنافذ ذو نسبة مساحة عالية عند معدلات تدفق مختلفة

Authors: Wissam H. Alawee وسام حميد عليوي --- Jafar M. Hassan جعفر مهدي حسن --- Wahid S. Mohammad وحيد شاتي محمد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 9 Pages: 169-184
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The uniform flow distrbiution in the multi-outlets pipe highly depends on the several parameters act togather. Therefor, there is no general method to achieve this goal. The goal of this study is to investigate the proposed approach that can provide significant relief of the maldistribution. The method is based on re-circulating portion of flow from the end of the header to reduce pressure at this region . The physical model consists of main manifold with uniform longitudinal section having diameter of 152.4 mm (6 in), five laterals with diameter of 76.2 mm (3 in), and spacing of 300 mm. At first, The experiment is carried out with conventional manifold, which is a closed-end. Then, small amount of water is allowed by controling the valve located at the end of the manifold slowly. The pressure and the flow distribution among the lateral pipes were recorded. Different inlet flows have been tested and the values of these flows are (625, 790, and 950) l/min. The result reveals that the conventional header give high non-uniform flow distrbution and the distribution of flow is greatly improved by using the perposed methods . When the recircluting ratio is of 15%, the non-uniform coefficient (the stander devation) is reduced from 0.48 to 0.13 which means improves in the flow distribution by 75%.

التوزيع المنتظم للجريان خلال الانابيب متعددة المنافذ يعتمد بشكل كبير على العديد من المتغيرات التي تؤثر بشكل مجتمع. لذلك لا توجد هناك طريقة محددة لتحقيق هذا الهدف. البحث الحالي هو تطوير لطريقة مقترحة يمكن ان تقلل من سوء توزيع الجريان. تستند هذه الطريقة على سحب نسبة محددة من المائع من النهاية المغلقة للانبوب المتفرع وذلك لتقليل الضغط المرتفع في هذه المنطقة. يتكون مقطع الاختبار المستخدم في البحث من انبوب رئيسي بقطر (152.4 ملم) وخمسة انابيب فرعية بقطر (76.2 ملم)، المسافة بين الانابيب الفرعية كانت (300 ملم). أنجزت التجارب في البداية على مقطع الاختبار بالتصميم التقليدي (النهاية مغلقة) بعد ذلك يتم السماح لكميات مختلفة من الماء من المرور من النهاية المغلقة من خلال صمام تحكم مثبت في نهاية الانبوب. استخدمت ثلاثة قيم مختلفة لكمية التدفق الداخل خلال التجارب وهي (625، 790، 950) لتر/ثانية. بينت النتائج ان عملية سحب جزء من الماء من النهاية المغلقة للانبوب المتفرع يساهم الى حد كبير في تحسين توزيع الجريان، حيث انه عند نسبة اعادة تدوير مقدارها (%15) قلت قيم معامل الانحراف من 0.48 الى 0.13، وهذا يحسن من توزيع الجريان بمقدار %75.


Article
Exergy Analysis of a Domestic Refrigerator
تحليل الإكسيرجي لثلاجة منزلية

Authors: Samir Akram Mahmood سمير أكرم محمود --- Wahid S. Mohammad وحيد شاتي محمد --- Loauy Abd Al-Azez Mahdi لؤي عبد العزيز مهدي
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 9 Pages: 1-20
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An energy and exergy thermodynamic analysis using EES program was done for a domestic refrigerator working with R-134a using vapor compression refrigeration cycle. The analysis deals with the system component, i.e. compressor, condenser, evaporator and the expansion device. The analysis depends on the entropy generation minimization approach to improve the refrigerator performance by exploring the optimum design points. These design points were derived from three different theories governing the entropy generation minimization using exergy analyzing method. These theories were first applied to find the optimum balance between the hot inner condenser area and the cold inner evaporator area of the refrigerator and between its hot and cold thermal conductances. Nine types of condensers were used according to its internal surface area and thermal conductance, in order to reach the minimum entropy generation in the refrigerator. The results showed that the compressor has the lowest exergy efficiency of 25%. The expansion device was the second component after the compressor with exergy efficiency of 92%, followed by the condenser with an efficiency of 93%. The evaporator was found to have an exergy efficiency of 98 %. The experimental tests were repeated for the nine condensers sizes with three different ambient temperatures 25℃, 30℃ and 35℃. The exergy analysis showed that the design of the refrigerator mainly depends on thermal conductance calcuAn energy and exergy thermodynamic analysis using EES program was done for a domestic refrigerator working with R-134a using vapor compression refrigeration cycle. The analysis deals with the system component, i.e. compressor, condenser, evaporator and the expansion device. The analysis depends on the entropy generation minimization approach to improve the refrigerator performance by exploring the optimum design points. These design points were derived from three different theories governing the entropy generation minimization using exergy analyzing method. These theories were first applied to find the optimum balance between the hot inner condenser area and the cold inner evaporator area of the refrigerator and between its hot and cold thermal conductances. Nine types of condensers were used according to its internal surface area and thermal conductance, in order to reach the minimum entropy generation in the refrigerator. The results showed that the compressor has the lowest exergy efficiency of 25%. The expansion device was the second component after the compressor with exergy efficiency of 92%, followed by the condenser with an efficiency of 93%. The evaporator was found to have an exergy efficiency of 98 %. The experimental tests were repeated for the nine condensers sizes with three different ambient temperatures 25℃, 30℃ and 35℃. The exergy analysis showed that the design of the refrigerator mainly depends on thermal conductance calculations rather than the surface inner area estimation.lations rather than the surface inner area estimation.

في العمل الحالي، تم إجراء تحليل حراري للطاقة والإكسيرجي باستخدام برنامج EES لثلاجة منزلية تعمل بغاز R-134a وبدورة التثليج الانضغاطية. وتناول التحليل مكونات النظام، أي الضاغط والمكثف والمبخر وأداة الخنق. وأعتمد التحليل على نهج تقليل توليد الإنتروبي. أجريت هذه الدراسة لتحسين أداء الثلاجة واستكشاف نقاط التصميم الأمثل لها. وقد استمدت نقاط التصميم هذه من ثلاثة نظريات مختلفة تحكم تقليل توليد الإنتروبي باستخدام نهج تحليل الإكسيرجي. تم تطبيق هذه النظريات أولاً للحصول على التوازن الأمثل بين منطقتي المكثف الداخلية الساخنة والمبخر الداخلية الباردة في الثلاجة وبين الايصالية الحرارية الساخنة والباردة. وتم استخدام تسعة أنواع من المكثفات وفقاً لمساحتها الداخلية السطحية والايصالية الحرارية، من أجل الوصول إلى الحد الأدنى من توليد الإنتروبي في الثلاجة. أظهرت النتائج أن الضاغط لديه أقل كفاءة إكسيرجي وكانت 25%. وكانت أداة الخنق المكون الثاني بعد الضاغط مع كفاءة إكسيرجي 92%، يليه المكثف بكفاءة 93%. اما كفاءة الإكسيرجي للمبخر كانت 98%. تم تكرار الاختبارات العملية لأحجام المكثف التسعة لثلاث درجات حرارة سيليزية محيطية مختلفة 25، 30 و35. أظهر تحليل الإكسيرجي أن تصميم الثلاجة يعتمد أساساً على حسابات الايصالية الحرارية، وليس على المساحة السطحية الداخلية المخمنة.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (2)

Arabic and English (1)


Year
From To Submit

2018 (1)

2015 (1)

2014 (1)