research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Laminar Natural Convection Heat Transfer Between Ducted Parallel Plates

Authors: Hazim S.Hamad --- Yasin K. Salman
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2008 Volume: 14 Issue: 3 Pages: 2786-2803
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Laminar natural convection heat transfer to air flow in a ducted two parallel plates subjected to same constant heat flux has been studied experimentally. In this study a test rig has been designed and constructed to allow studying the effect of plate spacing and plates angle of inclination on the heat transfer process. The study covers three plate spacing 15 mm, 35mm and 60 mm that makes plate aspect ratio (AR) 24, 10.285 and 6, The heat flux implemented in all test runs varies between 55 W/m2 – 340 W/m2 that makes the modified Rayleigh number (Ra) varies from 105 -108 . Experimental results presented as plate temperature distribution, variation of local heat transfer coefficient and the relation between Nu and Ra, reveal for the range of parameters mentioned above, an improvement in heat transfer process as the AR values change from 6 to 24 and the improvement rates is higher for the lower heat flux test (lower Ra). A correlation of the results were made in the form of Nuvr (Gr/AR) in which the effect of duct aspect ratio (AR) has been introduced.

تم في هذا البحث دراسة عملية ونظرية لانتقال الحرارة بالحمل الطبيعي الطباقي لجريان الهواء في مجرى بلوحين متوازيين مسخنين بشكل متماثل وبفيض حراري ثابت. الجانب العملي أشمل على تصميم وبناء جهاز مختبري يُمكن من دراسة تأثير المسافة بين اللوحين المسخنين وزاوية ميلان اللوحين على عملية أنتقال الحرارة. الدراسة غطت ثلاث مسافات وهي 15 mm و35 mm و60 mm والتي تعطي قيم للنسبة الباعية (AR = L/D) 24، 10.285، 6 على التوالي. كان مدى الفيض الحراري المجهز للوحين ولجميع الاختبارات يتراوح بين 340 W/m2 – 55 W/m2 وهذا يجعل التغير بقيم رقم رايلي المطور (Ra) تتراوح بين 108 – 105. النتائج العملية والتي عرضت بشكل توزيع درجات الحرارة على اللوح وتغير معامل أنتقال الحرارة الموقعي والعلاقة بين رقم نسلت (Nu) مع رقم رايلي (Ra) كشفت ولمدى المقادير المذكورة أعلاه تحسن في عملية أنتقال الحرارة لتغير قيم Ar من 6 إلى 24 ويكون التحسن أعلى لقيم الفيض الحراري المنخفض (لقيم Ra المنخفض). النتائج العملية تم تحويلها إلى علاقات أرتباطية بين رقم نسلت ونسبة رايلي المطور إلى النسبة الباعية للمجرى (Gr/Ar) والتي تظهر تأثير النسبة الباعية في عملية أنتقال الحرارة.

Keywords


Article
Experimental Study of Mixed Convection Heat Transfer for a Thermally Developing Air Flow in an Inclined Annulus

Authors: Ahmed J.Shkarah --- Yasin K.Salman
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2005 Volume: 11 Issue: 4 Pages: 683-699
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The investigation-included experiments were conducted to investigate the local and average mixed convection heat transfer coefficient for thermally developing and fully developed hydrodynamically laminar airflow in an inclined annulus. The experimental setup, using an aluminum annulus having a radius ratio of (0.41) and the inner tube with a heated length of (0.85m) with constant wall heat flux boundary conditions. The investigation covered Reynolds number range from (332 to 1128) and heat flux varied from (82w/m2 to 545w/m2). The air is developed hydrodynamically by using the entrance section annulus (calming section) having the same inner and outer diameter as a test section but with variable lengths. The entrance sections included a long calming section with a length of 90 cm (L/Dh =20.93) and short calming section with lengths of 60 cm (L/Dh =13.95). The results obtained represent the temperature distribution along the inner tube surface, the local and average Nusselt number distributions with the dimensionless axial distance (Z+). For all annulus orientations and all entrance sections, the results show an increase in the Nusselt number values as the heat flux increases and as the angle of the inclination moves from the vertical to the horizontal position. A comparison was made between the experimental results and the available previous work of Mataira, D. and Subba Raju, K. (1975), for the local Nusselt number distribution with the dimensionless axial distance (Z+). The results obtained showed a good agreement and has the same trend that obtained in the previous work.

يتضمن هذا البحث إجراء تجارب عملية لبحث معامل انتقال الحرارة الموقعي والمعدل بواسطة الحمل المختلط لجريان المواء الطباقي المتطور حرارياً وتام التطور هيدروداينميكياً في أنبوب حلقي مائل. يتكون الجهاز العملي من أنبوب حلقي مائل نسبة القطر له (0.41) و أنبوب داخلي مسخن و بطول (m0.85) تحت الشرط الحدي بثبوت الفيض الحراري. يتراوح رقم رينولدز في هذا البحث من 332 إلى 1128، وكذلك يتغير الفيض الحراري من (82w/m2 إلى 545w/m2). يكون الهواء تام التطور باستعمال أنابيب مدخل حلقية (أنابيب تهدئة) لها نفس قطر الأنبوب الداخلي والخارجى لجزء الاختبار ولكن بأطوال مختلفة. تتضمن أنابيب المدخل أنبوب طويل بطول (20cm) (L/Dh=20.93) وكذلك أنبوب مدخل قصير بطول (60cm) (L/Dh=13.95). النتائج المستخرجة وضحت توزيع درجة الحرارة على سطح الأنبوب الداخلي، وكذلك تون يع رقم نسلت الموقعي والمعدل مع المسافة المحورية اللابعدية (Z+). لكل زوايا ميل الأنبوب الحلقي و لكل أنبوبي المدخل المستخدمين، بينت النتائج إن قيم رقم نسلت تزداد كلما ازداد الفيض الحراري وكذلك يزداد رقم نسلت كلما زاوية ميل الأنبوب الحلقي تتغير من الموقع العمودي إلى الموقع الأفقي. أجريت مقارنة بين الدراسة العملية والعمل السابق للأدبيات المتوفرة لعمل Mataira, D. and Subba Raju, K. (1975)، لتوزيع رقم نسلت الموقعي مع المسافة المحورية اللابعدية (Z+) حيث أظهرت النتائج موافقة جيدة وتم الحصول على نفس الشكل الذي حصل عليه الباحث.


Article
Combined Convection Heat Transfer to Thermally Developing Flow in Horizontal Circular Cylinder

Authors: Hussein A. Mohammed --- Hassain H. Ahmad --- Yasin K. Salman
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2006 Volume: 12 Issue: 1 Pages: 1-15
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Experiments were conducted to study the local and average heat transfer by mixed convection for hydrodynamically fully developed but thermally developing laminar air flow in horizontal circular cylinder . The experimental setup using an aluminum cylinder as test section with 30 mm inside diameter and 900 mm heated length (L/D=30) is subjected to a constant wall heat flux boundary condition. The investigation covers Reynolds number range from (400 to 1600) , heat flux varied from(60W/m2 to 400w/m2) and by using an aluminum entrance section pipes (calming sections) having the same inside diameter as test section pipe but with variable lengths as entrance sections. The entrance sections included a long calming section of length 240 cm (L/D=80) and two short calming sections with lengths 60 cm (L/D=20), 120 cm (L/D=40).The results present the temperature variation along the cylinder surface and the the local and average Nusselt number variation with the dimensionless axial distance (Z+) . For all entrance sections , the results show an increase in the Nusselt number value as the heat flux increases. Also, the mixed convection regime can be bounded by a suitable selection of (Re) number ranges and the heat flux ranges. The obtained Richardson number (Ri) range varied approximately from(0.1171 to 12.54).

اجريت تجارب لدراسات عملية لدراسة انتقال الحرارة الموقعي والمعدل بطريقة الحمل المختلط لجريان الهواء الطباقي تام التطور والمشكل حراريا في داخل اسطوانة دائرية افقية.يتكون الجهاز المستخدم من اسطوانة من الالمنيوم وهي جزء من الاختبار بقطر (30ملم) وبطول (900 ملم) ، نسبة الطول الى القطر تعادل (L/D=30)تحت فيض حراري ثابت. يتراوح رقم رينولدز في هذا البحث من (400) الى (1600) اما الفيض الحراري فيتغير من 60W/m2 الى 400w/m2 وباستعمال انابيب في المدخل (انابيب تهدئة) من الالمنيوم لها نفس القطر الداخلي لجزء الاختبار ولكن باطوال مختلفة . انابيب المدخل تتضمن انبوب مدخل طويل بطول (240 سم) (L/D=80) وكذلك انابيب قصيرة في المدخل وباطوال (60 سم) (L/D=20) و (120 سم) (L/D=40) على التوالي . وضحت النتائج تغير درجة الحرارة على طول سطح الاسطوانة وكذلك تغير رقم نسلت الموقعي (Nux) والمعدل (Nu)مع المسافة المحورية غير البعدية ( +Z) ، لكل الاطوال المستخدمة ، وبينت النتائج زيادة رقم نسلت كلما زاد الفيض الحراري وكذلك تم الحصول على منطقة الحمل المختلط من خلال الاختبار المناسب لرقم رينولدز وقيم الفيض الحراري . يتغير رقم (Ri) الذي تم الحصول عليه تقريبا من (0.1171) الى (12.54).


Article
The Effect of Restriction Shape On Laminar Natural Convection Heat Transfer InA Vertical Circular Tube
تأثير شكل المقيّد على انتقال الحرارة الطباقي بالحمل الطبيعي في انبوب دائري شاقولي

Authors: Hussein Ahmed Mohammed حسين احمد محمد --- Dr. Yasin K. Salman ياسين خضير سلمان
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2005 Volume: 1 Issue: 1 Pages: 83-100
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Natural convection heat transfer is experimentally investigated for laminar air flow in a vertical circular tube by using the boundary condition of constant wall heat flux in the ranges of (RaL) from (1.1*109) to (4.7*109). The experimental set-up was designed for determining the effect of different types of restrictions placed at entry of heated tube in bottom position, on the surface temperature distribution and on the local and average heat transfer coefficients. The apparatus was made with an electrically heated cylinder of a length (900mm) and diameter (30mm). The entry restrictions were included a circular tube of same diameter as the heated cylinder but with lengths of (60cm, 120cm), sharp-edge and bell-mouth. The surface temperature along the cylinder surface for same heat flux would be higher values for circular restriction with length of (120cm) and would be smaller values for bell-mouth restriction. The results show that the local Nusselt number (Nux) and average Nusselt number are higher for bell-mouth restriction and smaller values for (120cm) restriction. For all entry shape restrictions, the results show that the Nusselt number values increases as the heat flux increases. From the present work an empirical correlations were obtained in a form of (Log ) versus (Log ) for each case investigated and obtained a general correlation for all cases which reveals the effect of restriction existence on the natural convection heat transfer process in a vertical circular tube.

ُبحث عملياً انتقال الحرارة بالحمل الطبيعي لجريان الهواء الطباقي في داخل أنبوب دائري شاقولي باستخدام شرط ثبوت الفيض الحراري ولمدى تغير رقم رايـلي (RaL) من (*109 1.1 ) إلى (9*10 4.7). ُصمم الجهاز العملي لإيجاد تأثير الأنواع المختلفة من المقيد (restriction) الموضوع في مدخل الأنبوب وفي الموقع السفلي لأنبوب التسخين, على درجة الحرارة على طول سطح الأنبوب المسخن وكذلك على معامل انتقال الحرارة الموقعي و المعدل. الجهاز العملي المستخدم يتكون من اسطوانة مسخنة حرارياً بطول (900mm) وبقطر داخلي (30mm). مقيدات الدخول تتضمن أنبوب دائري أسطواني له نفس القطر الداخلي لأنبوب التسخين ولكن بأطوال(120cm, 60cm), وكذلك مقيد بشكل حافة حادة (sharp-edge) بالإضافة إلى مقيد بشكل فم الجرس (bell-mouth). لقد وجد من خلال النتائج العملية أن درجة الحرارة على طول سطح الاسطوانة تكون أعلى ما يمكن للمقيد الأسطواني الذي طوله (120cm) وتكون اقل ما يمكن في حالة المقيد الذي بشكل فم الجرس (bell-mouth) عند نفس الفيض الحراري. أظهرت النتائج أن قيم رقم نسلت الموقعي (Nux) والمعدل تكون أعلى ما يمكن في حالة المقيد الذي بشكل فم الجرس (bell-mouth) وتكون اقل ما يمكن في حالة المقيد الأسطواني الذي طوله (120cm) , وأيضا لكل الحالات المستخدمة ,بينت النتائج زيادة رقم نسلت كلما زاد الفيض الحراري . لقد تم الحصول على معادلات تجريبية(empirical correlations) بشكل ) (Log ضد ( Log) لكل حالة من الحالات المدروسة في البحث وكذلك تم الحصول على معادلة عامة والتي ُتظهر تأثير وجود المقيد على عملية انتقال الحرارة بالحمل الطبيعي في داخل أنبوب دائري شاقولي.


Article
Free Convective Heat Transfer with Different Sections Lengths Placed at the Exit of a Vertical Circular Tube subjected to a Constant Heat Flux
انتقال الحرارة بالحمل الحر باستخدام مقاطع مختلفة الاطوال وموضوعةعند مخرج انبوب دائري شاقولي معرض لفيض حراري ثابت

Authors: Hussein A. Mohammed حسين احمد محمد --- Yasin K. Salman ياسين خضير سلمان
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2007 Volume: 3 Issue: 3 Pages: 31-52
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A free convective heat transfer from the inside surface of a uniformly heated vertical circular tube has been experimentally investigated under a constant wall heat flux boundary condition for laminar air flow in the ranges of RaL from 6.9 108 to 5 109. The effect of the different sections (restrictions) lengths placed at the exit of the heated tube on the surface temperature distribution, the local and average heat transfer coefficients were examined. The experimental apparatus consists of aluminum circular tube with 900 mm length and 30 mm inside diameter (L/D=30). The exit sections (restrictions) were included circular tubes having the same inside diameter as the heated tube but with different lengths of 600 mm (L/D=20), 900 mm (L/D=30), 1200 mm (L/D=40), 1500 mm (L/D=50), and 1800 mm (L/D=60). It was found that the surface temperature along the tube axial distance would be higher for restriction with length of 1800 mm (L/D=60) and it would be smaller for the restriction with length of 1200 mm (L/D=40). The results show that the local Nux and average Nusselt number were higher values for the restriction with length of 1200 mm (L/D=40) and smaller values for the restriction with length of 1800 mm (L/D=60). The results were correlated with empirical equations and presented as Log against Log for each case investigated and a general empirical equation was proposed for all cases.

يتناول البحث دراسة عملية لانتقال الحرارة بالحمل الحر لجريان الهواء الطباقي في داخل أنبوب دائري شاقولي باستخدام شرط ثبوت الفيض الحراري ولمدى تغير لرقم رايـلي (RaL) من (*108 6.9 ) إلى (9*10 5). ُصمم الجهاز العملي لإيجاد تأثير طول المقيد (restriction) الموضوع في مدخل الأنبوب وفي الموقع العلوي لأنبوب التسخين, على درجة الحرارة على طول سطح الأنبوب المسخن وكذلك على معامل انتقال الحرارة وبالتالي على تغير رقم نسلت الموقعي (Nux) والمعدل . الجهاز العملي المستخدم يتكون من أنبوب من الالمنيوم مسخن حرارياً بطول ( 900mm) وبقطر داخلي (30mm). مقيدات الدخول تتضمن أنبوب دائري أسطواني له نفس القطر الداخلي لأنبوب التسخين ولكن بأطوال(, 1500 mm, 1200 mm, 900 mm, ,600 mm1800 mm), لقد وجد من خلال النتائج العملية أن درجة الحرارة على طول سطح الأنبوب تكون أعلى ما يمكن للمقيد الذي طوله (1800 mm) وتكون اقل ما يمكن للمقيد الذي طوله (1200 mm). أظهرت النتائج أن قيم رقم نسلت الموقعي (Nux) والمعدل تكون أعلى ما يمكن للمقيد الذي طوله (1200 mm) وتكون اقل ما يمكن في حالة المقيد الذي طوله (1800 mm). لقد تم الحصول على معادلات تجريبية (empirical equations ) بشكل ( Log) ضد ) (Log لكل حالة من الحالات المستخدمة في البحث وكذلك تم الحصول على معادلة عامة تربط جميع الحالات


Article
Study of Performance and Prediction of Heat Releace in Compression Ignition Engin Working on Ethyl Alcohol and Gas-Oil Solution

Authors: Abdul-kahdim M. H. --- M A. Abdul-Hadi --- Yasin K. Salman
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2005 Volume: 11 Issue: 1 Pages: 137-147
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The effect of using solutions of ethanol and gas-oil (duel fuel ) to fuel the diesel engine on engine performance and heat release have been studied experimentally. A single cylinder diesel engine type Recardo (E6/US) was used and the ethanol percentage in the solution was varied from 0 to 20 percent. The results showed that, in general, addition of ethanol to gas-oil cause the maximum power output to decrease at medium and high range of speed and it was nearly the same as that of the straight gas-oil at low speed ranges. The specific fuel consumption of the dual is nearly the same as that of straight gas-oil at low and medium ranges of load. But at high ranges of load the specific fuel consumption was increase. In general, the addition of ethanol to gas-oil cause the maximum rate of heat release to increase during the first stage of combustion and decrease during the second stage of combustion. Further substitution of gas-oil with ethanol (higher than 20 percent) was limited by knock.

تم في هذا البحث دراسة تأثير استخدام وقود ثنائي يتكون من محلول الايثانول وزيت الغاز على اداء محرك ديزل واستنتاج الحرارة المتحررة منه ولتحقيق ذلك فقد استخدم محرك ديزل نوع ريكاردو (E6/US) وتراوحت نسبة الايثانول في المحلول من (صفر الى 20) جزء.اظهرت النتائج المستحصلة ان اضافة الايثانول الى زيت الغاز تؤدي الى تناقص القدرة العظمى الخارجة من المحرك عند السرع المتوسطة والعالية بشكل عام وتبقى مشابهة لتلك المستحصلة من زيت الغاز لوحده عند السرع القليل.كما اظهرت النتائج بان الاستهلاك النوعي للوقود الثنائي يكون مماثلاً تقريباً للاستهلاك النوعي لوقود زيت الغاز لوحده عند الاحمال المتوسطة والخفيفة ولكنه يزداد عند الاحمال العالية.وقد اظهرت النتائج بشكل عام ان اضافة الايثانول الى زيت الغاز تؤدي الى زيادة معدل الحرارة المتحررة في المرحلة الاولى من الاحتراق ونقصانها من المرحلة الثانية من الاحتراق .لم يمكن اضافة كمية من الايثانول ( اكثر من عشرين جزء) لتسببها في احداث طرق عالي في المحرك.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (4)

Arabic and English (2)


Year
From To Submit

2008 (1)

2007 (1)

2006 (1)

2005 (3)