research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Development Zinc-selective membrane potentiometric sensor based on crown ether.

Author: Zeina Mohammed Kadhum Al-Mossawy
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2006 Volume: 4 Issue: 1 Pages: 25-35
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

A new liquid selective electrode for Zinc ions based on Di-benzo-18-crown-6 as membrane carrier with plasteicezer (DOPP) was prepared. The sensor exhibits a nernstian response for Zn2+ range with nernstian slope ,and detection limit of( )activity unit. .It has a response time of a bout(30 s) and can be used for at least (60 days) without any divergence. The proposed membrane sensor revealed good selectivity for Zn2+ over variety of other metal ions and could be used in pH range of (3-7).It was successfully used for direct determination of Zn2+ in solution.

لقد حُضر قطب انتقائي سائل جديد لايون الزنك المعتمد على الايثر التاجيDB18C6 والمذيب الملدن Di –n-octyl phenyl phosphonate (DOPP) وقد حقق القطب الحساس إستجابة نيرنستية لايونات الزنك لمدى وحدة فعالية وبميل نيرنستي . وحد كشف وحدة فعالية.وكان زمن الاستجابة حوالي (30 s) ويمكن ان يستعمل لفترة (60 days) على الاقل بدقة قياسات ثابتة.واستعمل القطب بنجاح في تقدير أيونات الزنك مباشرة في المحلول

Keywords


Article
Development Zinc-selective membrane potentiometric sensor based on crown ether.

Author: Zeina Mohammed Kadhum Al-Mossawy
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2006 Volume: 4 Issue: 4 Pages: 79-85
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

A new liquid selective electrode for Zinc ions based on Di-benzo-18-crown-6 as membrane carrier with plasteicezer (DOPP) was prepared. The sensor exhibits a nernstian response for Zn2+ range with nernstian slope ,and detection limit of( )activity unit. .It has a response time of a bout(30 s) and can be used for at least (60 days) without any divergence. The proposed membrane sensor revealed good selectivity for Zn2+ over variety of other metal ions and could be used in pH range of (3-7).It was successfully used for direct determination of Zn2+ in solution.

لقد حُضر قطب انتقائي سائل جديد لايون الزنك المعتمد على الايثر التاجيDB18C6 والمذيب الملدن Di –n-octyl phenyl phosphonate (DOPP) وقد حقق القطب الحساس إستجابة نيرنستية لايونات الزنك لمدى وحدة فعالية وبميل نيرنستي . وحد كشف وحدة فعالية.وكان زمن الاستجابة حوالي (30 s) ويمكن ان يستعمل لفترة (60 days) على الاقل بدقة قياسات ثابتة.واستعمل القطب بنجاح في تقدير أيونات الزنك مباشرة في المحلول.

Keywords

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2006 (2)