research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
تقدير الكوافنسين بطريقة كروماتوغرافيا السائل ذات الاداء العالي في مستحضرات الشراب وفي المياه الصناعية المطروحة

Authors: suhaib N. Lottfi صهيب نايف لطفي --- Nief Rahman Ahmed نايف رحمان احمد
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2013 Volume: 10 Issue: 3عدد خاص بموتمر الكيمياء Pages: 1014-1022
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml respectively. The method was validated for its linearity, precision and accuracy .The proposed method was successfully applied for the determination of guaifenesin in syrups and industrial effluent samples.

تم اختبار طريقة كروماتوغرافيا السائل ذات الأداء العالي حيثتميزت الطريقة بالبساطة والدقة والسرعة والضبط العالي لتقدير الكوافنسين في حالته النقية وفي بعض مستحضراته الصيدلانيةوفي المياه الصناعية المطروحة.حيث تم الفصل باستخدام كولوم نوع(L7)و استخدام مزيج الميثانول الماء واسيتونتريل كوسط ناقل نسبة (10:10:80) حجمحجمحجم. وبسرعة جريان 1 مل/دقيقة واستخدام مكشاف الاشعة فوق البنفسجية عند الطول الموجي 254 نانوميتر وفي درجة حرارة المحيط حيث كان زمن الاحتباس 2.4 دقيقه, وامكن تقدير الكميات التي تتراوح بين 0.08-0.8ملغراممل وبحدي كشف وكمي هما 6 و 18 مابكروغراممل على التوالي واختبر مصداقية الطريقة بقياس استقامة الخط البياني والضبط والدقة واستخدمت الطريقة بنجاح لتقدير الكوافنسين في مستحضرات الشراب وفي المياه الصناعية المطروحة.


Article
High Performance Liquid Chromatographic Method for Determination of Sildenafil Citrate (Viagra) in Pharmaceutical Formulation and Industrial Effluent Sample
استخدام طريقه كروماتوغرافيا السائل عالي الأداء لتقدير السيلدينافيل ستريت(الفيكرا) في مستحضراته الصيدلانية وفي المياه الصناعية المطروحة

Authors: Nief R. Ahmed نايف رحمن --- Suhaib N. Lottfi صهيب نايف لطفي
Journal: Rafidain journal of science مجلة علوم الرافدين ISSN: 16089391 Year: 2013 Volume: 24 Issue: 5E Pages: 24-31
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

A simple, precise, rapid and accurate reversed–phase high performance liquid chromatographic method has been developed for the determination of sildenafil citrate in a pure form, pharmaceutical formulations and industrial effluent samples. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol: water: triethylamine (630: 370 :2 v/v/v) and adjusted to pH 4.0 with dilute phosphoric acid as a mobile phase at a flow rate of 1.0 ml.min-1.Uv detection was performed at 220 nm at ambient temperature (25 °C). The retention time for sildenafil citrate found to be 4.6 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 10 to 70 µg/ml. Limit of detection (LOD) and limit of quantification (LOQ) were 60 ng/ml and 180 ng/ml respectively. The method was validated for its linearity, precision and accuracy. The proposed method was successfully applied to the determination of sildenafil citrate in tablets and industrial effluent samples.

تم تطوير طريقة كروماتوغرافيا السائل عالي الأداء لتقدير السلدينافيل ستريت بحالته النقية وفي بعض مستحضراته الصيدلانية وفي المياه الصناعية المطروحة. تتميز الطريقة بالبساطة والدقة والسرعة والضبط العالي، إذ تم الفصل باستخدام كولوم نوع L7 و استخدام مزيج الميثانول والماء وثلاثي اثيل امين بوصفه وسطاً ناقلاً بنسبة (2:370:630) حجم/ حجم/ حجم. وتم تثبيت الداله الحامضيه عند 4.0 بواسطة حامض الفسفوريك المخفف وبسرعة جريان 1 مل/دقيقة واستخدام مكشاف الأشعة فوق البنفسجية عند الطول الموجي 220 نانوميتر وفي درجة حرارة المحيط ( 25م°)، وأمكن تقدير الكميات التي تتراوح بين 70-10 مايكروغرام /مل وبحدي كشف وكمي هما 60و180 نانو غرام/ مل على التوالي واختبرت المصداقية بقياس استقامة الخط البياني والضبط والدقة واستخدمت الطريقة بنجاح لتقدير السلدينافل ستريت في الأقراص الدوائية وفي المياه الصناعية المطروحة.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2013 (2)