research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Experimental Behavior of Laced Reinforced Concrete One Way Slab under Static Load
تصرف البلاطات الاحادية الاتجاه والحاوية على حديد متعرج تحت تأثير الاحمال الساكنة

Authors: Abaas Abdulmajeed Allawi عباس عبد المجيد علاوي --- Hussain Askar Jabir حسين عسكر جابر
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 5 Pages: 42-59
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Test results of eight reinforced concrete one way slab with lacing reinforcement are reported. The tests were designed to study the effect of the lacing reinforcement on the flexural behavior of one way slabs. The test parameters were the lacing steel ratio, flexural steel ratio and span to the effective depth ratio. One specimen had no lacing reinforcement and the remaining seven had various percentages of lacing and flexural steel ratios. All specimens were cast with normal density concrete of approximately 30 MPa compressive strength. The specimens were tested under two equal line loads applied statically at a thirds part (four point bending test) up to failure. Three percentage of lacing and flexural steel ratios were used: (0.0025, 0.0045 and 0.0065). Three values of span to effective depth ratio by (11, 13, and 16) were considered, the specimens showed an enhanced in ultimate load capacity ranged between (56.52% and 103.57%) as a result of increasing the lacing steel ratio to (0.0065) and decreasing the span to effective depth ratio by (31.25%) respectively with respect to the control specimen. Additionally the using of lacing steel reinforcement leads to significant improvements in ductility by about (91.34%) with increasing the lacing steel ratio to (0.0025) with respect to the specimen without lacing reinforcement.

في هذا البحث تم مناقشة النتائج العمليه لثمانية بلاطات خرسانيه احادية الاتجاه مسلحه وحاويةعلى تسليح متعرج. ان الغرض من هذا البحث هو دراسه تأثير استخام التسليح المتعرج على سلوك البلاطات الاحادية الاتجاه. وكانت المتغيرات نسبة حديد التسليح المتعرج و هي)0, 0.0025, 0.0045, 0.0065), نسبة الحيد الرئيسي وهي (0.0025,0.0045, 0.0065( ونسبة الطول الصافي الى العمق الفعال للبلاطةوهي (13,16 , 11) . احد العينات لاتحتوي على حديد متعرج اما العينات المتبقيه فكانت تحتوي على نسب مختلفة من حديد التسليح المتعرج والرئيسي. بينت النتائج العملية بان التحمل الكلي للبلاطات تحسن بمقدار (%56,52) نتيجه لاستخدام الحديد المتعرج بنسبة (0.0065) و بمقدار (%103,57) كنتيجة لتقليل نسبة الطول الصافي الى العمق الفعال بمقدار (31,25%) للبلاطات الحاوية على حديد متعرج بنسب متساوية. من ناحيه اخرى فأن استخدام الحديد المتعرج حسن وبشكل ملحوظ معامل المطيلية للبلاطات حيث كانت نسبة الزيادة حوالي (91,34%) للبلاطة ذات نسبة تسليح متعرج (0.0025) مقارنة مع البلاطة بدون حديد تسليح متعرج.


Article
Response of Laced Reinforced Concrete One Way Slab to Repeated Loading
إستجابة البلاطات الخرسانية المسلحة الاحادية الاتجاه والحاوية على حديد متعرج للاحمال المتكررة

Authors: Abaas Abdulmajeed Allawi عباس عبد المجيد علاوي --- Hussain Askar Jabir حسين عسكر جابر
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 9 Pages: 36-54
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Test results of nine reinforced concrete one way slab with and without lacing reinforcement are reported. The tests were designed to study the effect of the lacing reinforcement on the flexural response of one way slabs. The test parameters were considered is the lacing steel ratios of (0, 0.0025, 0.0045, and 0.0065), flexural steel ratios of (0.0025, 0.0045, and 0.0065) and span to the effective depth ratios of (11, 13, and 16). Two specimens had no lacing reinforcement and the remaining seven specimens had the lacing reinforcement. Four point bending test were carried out, one of the specimens was tested under the static load applied gradually up to failure and the other specimens were tested under repeated load (5 cycles) loading-unloading to 80% of the ultimate load of the control specimen then loaded manually by the hydraulic jack up to failure. The specimens showed an improving in ultimate load capacity ranged between (54.54% - 100%) as a result of increasing the lacing steel ratio to (0.0065) and decreasing the span to effective depth ratio by 31.25% respectively with respect to the control specimen. Additionally the using of lacing steel reinforcement leads to reducing the residual deflection by about (57.24%) for the specimen with the largest lacing reinforcement compared with the control specimen (without lacing reinforcement).

تم في هذا البحث مناقشة النتائج العمليه لتسعة بلاطات خرسانيه احادية الاتجاه مسلحه وحاويةعلى تسليح متعرج. ان الغرض من هذا البحث هو دراسه تأثير استخدام التسليح المتعرج على سلوك واستجابة البلاطات الاحادية الاتجاه. وكانت المتغيرات هي نسبة حديد التسليح المتعرج وهي(0.0025,0, 0.0045 , 0.0065), نسبة الحديد الرئيسي وهي (0.0025, 0.0045 , 0.0065) ونسبة الطول الصافي الى العمق الفعال للبلاطة وهي (13,16 , 11). اثنان من العينات لاتحتوي على حديد متعرج اما السبعة المتبقيه فكانت جميعها تحتوي على حديد التسليح المتعرج. تم فحص احدى العينات الغير حاوية على حديد متعرج ستاتيكيا الى الفشل بينما تم فحص العينات المتبقية تحت تاثير الاحمال المتكررة بخمسة دورات تحميلية الى حد 80% من قيمة الحمل الاقصى للعينة المفحوصة ستاتيكياً ثم تحميل العينة الى حد الفشل .بينت النتائج العملية بان التحمل الكلي للبلاطات تحسن بمقدار (%54,54) نتيجه لاستخدام الحديد المتعرج بنسبة (0.0065) و بمقدار (%100) كنتيجة لتقليل نسبة الطول الصافي الى العمق الفعال بمقدار (31,25%) للبلاطات الحاوية على حديد متعرج بنسب متساوية. من ناحيه اخرى فأن استخدام الحديد المتعرج قلل وبشكل ملحوظ مقدار الهطول الدائمي للبلاطات بنسبة (57,24%) للبلاطة ذات اعلى نسبة تسليح متعرج مقارنة مع البلاطة بدون حديد تسليح متعرج.