Aeration Tank Behavior in the Activated Sludge Wastewater Treatment Plant Startup Conditions Case study; (Wastewater Treatment plant of General Mosul hospital- IRAQ)
تصرف الخزان المهوى للحمأة المنشطة في معالجة المياه الثقيلة وخلال ظرف تشغيل ابتدائي

Author: Riyadh Mahmood Saleh Al-Obaidi رياض محمد صالح العبيدي
Journal: Muthanna Journal of Engineering and Technology(MJET) مجلة المثنى للهندسة والتكنولوجيا ISSN: 25720317 25720325 Year: 2011 Volume: 1 Issue: 1 Pages: 1-13
Publisher: Al-Muthanna University جامعة المثنى

Loading...
Loading...
Abstract

The biological unit in the waste water treatment plants can be considered the most sensitive treatment units. It begins work with dynamic conditions for several weeks until reach the steady state conditions. Therefore, this study was done to observe aeration tank behavior (activated sludge unit) in the wastewater treatment plant of general hospital complex of Mosul city. Sampling made daily for more than 30 days. The biological treatment monitoring parameter was tested. The study shown that there is need to about 45-60 days to complete the start up work to be the operation stable and successful (if it worked without seeding). There was simple growth of microorganisms with modest treatment of organic matter, and then it rose after 3 first weeks of operation. There was contrary relationship between organic content and suspended solids in the aeration tank; an equation of this relation has been presented. The pH has risen in the first days in the effluent wastewater, then return to be less than influent pH with a relative relation with the activity of the microorganisms and surface aeration in the tank. The EC was simply reduced in the Effluent along with the study.

تعد وحدة المعالجة البيولوجية الوحدة الاكثر حساسية بين وحدات محطة معالجة مياه الفضلات . تبدأ الوحدة عملها بظروف ديناميكية (غير مستقرة) لمدة أسابيع لحين وصولها الى حالة الثبات بالعمل. لذلك اجريت هذه الدراسة لمتابعة سلوك حوض التهوية (بوحدة الحمأة المنشطة) في محطة معالجة مياه الصرف الصحي لمجمع المستشفى العام في مدينة الموصل. وقد تم اخذ نماذج يومية من المحطة اثناء بدء تشغيلها لمدة تزيد على 30يوما . وتم قياس مؤشرات مراقبة عمل الوحدة البايولوجية. أظهرت الدراسة بأن هناك حاجة لفترة 45-60 يوما لاكتمال ظروف الابتداء والوصول الى العمل المستقر للوحدة (حين عدم اضافة بذور الحمأة المنشطة). وقد كان هناك نمو بسيط للاحياء المجهرية مع معالجة معتدلة للمحتوى العضوي في المياه الداخلة للمحطة، وتصاعد النمو بعد 3 اسابيع من التشغيل . وكان هناك علاقة عكسية بين محتوى المواد العضوية في حوض التهوية وبين المواد العالقة (الكتلة الحية). كما حصل ارتفاع لمؤشر الدالة الحامضية pH في الايام الاولى من بدء التشغيل ثم تراجع ليكون pH في المياه المعالجة اقل منه في الداخلة بسبب نشاط الاحياء المجهرية والتهوية السطحية في الحوض. بينما تناقص مؤشر التوصيلية الكهربائية بنسبة قليلة في المياه المعالجة على طول فترة الدراسة ، وتزايد استهلاك الاوكسجين عند اكتمال عملية البدء بالتشغيل.


Article
The Study of Temperature Effects On Activated Sludge Stability and it’s Dewaterability by using bioelectricity cell as a treatment unit.
دراسة تأثير تغير درجة الحرارة في تحسين قابلية نزع ماء الحمأة المنشطة واستقراريتها باستخدام الخلية الكهروحيوية كوحدة معالجة

Author: Samaher Jasim Mohamed سماهـر جاسم محمد
Journal: Anbar Journal of Engineering Sciences مجلة الأنبار للعلوم الهندسية ISSN: 19979428 Year: 2012 Volume: 5 Issue: 2 Pages: 295-310
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

%95.21 in (25 c°, 35 c°, 45 c°). In the anaerobic treatment SRF is reduction by percent %91.65, %97.25, %92.7 in (25 c°, 35 c°, 45 c°).Percent reduction of dry solid (DS) concentration in the aerobic treatment is %7.61, %9.3 in (25c°, 35c°, 45c°) respectively. While in the aerobic treatment the percent reduced of DS was %75, %51, %16 respectively with (25c°, 35c°, 45c°). The results showed the effect of aerobic and anaerobic treatments of activated sludge with three different temperatures (25c°, 35c°, 45c°), on the dewatering of sludge and its stability and the hydraulic detention time with using bioelectricity cell. The study outcomes revealed that the biological treatment is enhanced dewaterability of the activated sludge for aerobic and anaerobic treatment, in the aerobic treatment the specific resistance to filtration (SRF) is reduction by percent%95.7.

تضمنت الدراسة الحالية محاولة التعرف على مدى تأثير المعالجة الهوائية واللاهوائية للحمأة المنشطة بأزمان مكوث هيدروليكية مختلفة وثلاث درجات حرارة هي (cº25 و35 و45) على قابلية نزع ماء الحمأة واستقراريتها باستخدام الخلية الكهروحيوية. أظهرت النتائج فعالية المعالجة الحيوية في رفع قابلية نزع الماء للحمأة المنشطة للمعالجتين الهوائية واللاهوائية, ففي المعالجة الهوائية انخفض معدل المقاومة النوعية لترشيح الحمأة بنسب %98.04 و%95.7 و%95.21 عند (cº25 و35 و45). كما انخفض معدل المقاومة النوعية لترشيح الحمأة للمفاعل اللاهوائي بنسب %91.65 و%97.25 و%92.7 عند (cº25 و35 و45).


Article
Early Prediction Of Toxic Shocks Happening In Activated Sludge Biological Systems
التنبؤ المبكر في حدوث الصدمات السمّية في أنظمة المعالجة البيولوجية التي تعمل بأسلوب الحماة المنشطة

Authors: Ma'an Hashim Mahmood معن هاشم محمود --- Ahmed Y. Shehab أحمد ياسين شهاب --- Riyadh M. Saleh Al- Obaidi رياض محمود صالح
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2010 Volume: 18 Issue: 1 Pages: 26-35
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract:The shocks became an important issue in operating wastewater treatment plant, because it may lead to biological unit damage in a short time. This study had been done to experience two separated ways in toxic shock happening prediction. Two glass basin (10L volume) used to conduct the study. The work was with completely mixed activated sludge. The studied ways of prediction were 1-the specific oxygen uptake rate (SOUR) of biomass in aeration tank , and 2-microscopic images monitoring. Two types of toxic material were used , the first was phenol (organic) and cyanide (inorganic inhibitors) with 40mg/l concentration in each of the basin separately. The results revealed that the two ways were useful in shock prediction. SOUR has raised with phenol shock in a short time , and has sharp dropped with cyanide shock (about 15 min.). the microscopic images revealed that filamentous growth happened in the bioflocs after short time of phenol shock. While a dispersed growth and pinpoint flocculation has appeared after short time of cyanide shock (leading to the biomass damage).Key words:activated sludge, toxic shock, shocks early predictionالمقدمة

الخلاصة:تُعدّ الصدمات الحاصلة في وحدات الحمأة المنشطة من المشاكل المهمة التي قد تضر بعمل المحطة البايولوجية. لذلك جرى في هذه الدراسة اختبار طريقتين منفصلتين للتنبؤ المبكر بحصول الصدمة. الأولى تتمثل بحساب استهلاك الأوكسجين في الكتلة الحية Specific Oxygen Uptake rate SOUR والثانية تتمثل بمراقبة الصور المجهرية لنماذج من الحمأة المأخوذة من حوض التهوية. وتم العمل مختبرياً باستخدام أحواض زجاجية بحجم 10 لتر (تعمل بأسلوب الحمأة المنشطة- المزج التام) وتسليط نوعين من المواد السمية احدها عضوي (الفينول) والأخر لا عضوي (السيانيد). أثبتت الدراسة بان طريقتي التنبؤ كانتا ناجحتين في الكشف عن مقدمة صدمة إذ حصل تغاير كبير في مؤشر SOUR (تصاعد حاد عند تسليط الفينول وانخفاض حاد عند تسليط السيانايد) في وقت وجيز (15 دقيقة) مما يدل على صلاحية الطريقة في تخمين حدوث صدمة في حوض التهوية. اما الطريقة الصورية فقد اثبت النتائج تغير شكل نمو اللبادات البايولوجية اعتماداً على نوع الصدمة (اذ تحولت من النمو المتكتل الى النمو الخيطي بشكل ملحوظ عند تسليط الفينول والى النمو المتشتت العصوي عند تسليط السيانيد) ذلك بوقت وجيز ايضاً لا يزيد على نصف ساعة. الكلمات الدالة : الحمأة المنشطة، الصدمة السمية، التنبؤ المبكر للصدمات.


Article
Investigate the Effects of F/M, MLSS, and Metal/MLSS Ratio on the Removal of Cd and Pb in the Activated Sludge Units,
تحري تأثير كل من الحمل العضوي وتركيز الحمأة ونسبة تركيز المعدن إلى تركيز الحمأة على إزالة الكادميوم والرصاص في وحدات الحمأة المنشطة

Loading...
Loading...
Abstract

AbstractThe objective of this research is to investigate the effect of each of the average organic load, the mixed liquor suspended solids(MLSS) in aeration tank and the ratio of concentration of metal to the MLSS on removal of cadmium and lead in activated sludge unit. Bench scale unit was used to conduct this study. Four glasses container were used, one for monitoring and others for examination of specific doses of lead and cadmium (5,10,20)mg/l. The capacity of sludge for metal under conditions of study were calculated. Dynamic constant of removal was computed depending on the result of study demonstrated as Frendlich and Langmuir equations, it is clearly shown that the relationship between capacity of sludge for cadmium to organic load is strong at three initial doses while lead was less correlated at the upper initial doses. As a result concentration of metals doesn't affect the removal efficiency of organic material at the range of the organic load used.Keywords: Cadmium, Lead, Activated sludge, Frendlich Equation, Langmuir Equation, Organic load

الخلاصة يهدف البحث إلى تحري تأثير كل من معدل الحمل العضوي وتركيز الحمأة في حوض التهوية ونسبة تركيز المعدن إلى تركيز الحمأة على إزالة الكادميوم والرصاص في وحدة حمأة منشطة ، وقد تم الاعتماد على العمل بالحجم ألمختبري لتحقيق أهداف الدراسة ، وذلك من خلال استخدام أربعة أحواض زجاجية ، احدها للمراقبة والأخرى تم فيها تسليط تراكيز ابتدائية معينة من كل من معدن الرصاص والكادميوم (5، 10، 20) ملغم/لتر، وقد تم احتساب معدلات استيعاب الحمأة للمعدن في ظل ظروف الدراسة، وقد جرى من خلال نتائج الدراسة حساب الثوابت الحركية للإزالة متمثلة بمعادلتي فرندلج ولانكمير كل على حدة ، وقد أظهرت الدراسة ارتباطا قويا بين سعة استيعاب الحمأة للكادميوم على الحمل العضوي بشكل كبير عند التراكيز الابتدائية الثلاثة، بينما للرصاص فقد اظهر اعتمادا قليلا عند التراكيز الابتدائية العليا المسلطة للمعدن ، وأخيرا لم يكن لتركيز المعدن تأثير واضح على كفاءة إزالة المواد العضوية ضمن مدى الحمل العضوي المتبع في هذه الدراسة . الكلمات الدالة : الكادميوم ، الرصاص ، الحمأة المنشطة ، معادلة فرندلج ، معادلة لانكمير ، الحمل العضوي

Listing 1 - 4 of 4