research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Study the effect of the proportion of coal and the size of the added grains on the thermal conductivity of the ceramic
دراسة تأثير نسبة الفحم المضاف وحجم حبيباته على التوصيلية الحرارية للسيراميك

Author: tagreed muslim alsaady تغريد مسلم الساعدي
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2012 Volume: 8 Issue: 1 Pages: 86-95
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Studied in this research the impact of the proportion of added coal and the size of its grains on the thermal conductivity of the samples of ceramic used soil as a basis and added to its coal percentages by weight are: (20, 10, 5.1, 0.5, 0.2, 0.1)% and four volumes of granulomas, and then compressed samples in tablets of 25mm diameter and burned much 1100оC. Calculated the thermal conductivity using a CD-I Lee's disk) (and then calculated the porosity and absorbency of water and the density of each sample. Found that there is a close relationship between thermal conductivity and the proportion of added coal and the size of its grians, with increasing thermal conductivity of the ratios weighted low-lying (0.2 - 0.1)% and then starts decreasing with increasing the proportion of coal in the sample, on the other hand decreasing thermal conductivity increase size granular added coal, recorded samples with ratios weighted high of 20% and size granular coarse (600-1180) μm lower values for the conduction heat. wecan take advantage of the low thermal conductivity of the work of thermal insulation ceramic used for lining furnaces, cooking and drying can also be employed in the manufacture of brick construction to increase the thermal isolation.

دُرس في هذا البحث تأثير نسبة الفحم المضاف وحجم حبيباته على التوصيلية الحرارية لعينات سيراميكية أستخدمت التربة Soil كمادة أساس وأضيف لها الفحم Coal بنسب وزنية هي : (20 , 10 , 5 , 1 , 0.5 , 0.2 , 0.1 )% ولأربعة حجوم حبيبية , ثم كُبست العينات بشكل أقراص قطر كل منها 25mm وحُرقت بدرجة 1100оC. حُسبت التوصيلية الحرارية بإستخدام قرص لي Lee’s disk) (ثم حُسبت المسامية وإمتصاصية الماء وكثافة كل عينة. وجد أن هناك علاقة وثيقة بين التوصيلية الحرارية ونسبة الفحم المضاف وحجم حبيباته , حيث تتزايد التوصيلية الحرارية للنسب الوزنية الواطئة (0.2 - 0.1 )% ثم تبدأ تتناقص مع تزايد نسبة الفحم في العينة , ومن جهة أخرى تتناقص التوصيلية الحرارية بزيادة الحجم الحبيبي للفحم المضاف حيث سجلت العينات ذات النسب الوزنية العالية 20% والحجم الحبيبي الخشن (600-1180) µm أقل قيم للتوصيلية الحرارية. يمكن الإستفادة من إنخفاض التوصيلية الحرارية لعمل عوازل حرارية سيراميكية تستخدم لتبطين أفران الطبخ والتجفيف كما يمكن توظيفها في صناعة طابوق البناء لزيادة عزله الحراري .


Article
A Study of the Influence of Additive Coal Percentage and Its Grain Size on Compressive Strength for Building Brick
دراسة تأثير نسبة الفحم المضاف وحجم حبيباته في متانة إنضغاط طابوق البناء

Author: Tagreed Muslim Al-Saadi تغريد مسلم الساعدي
Journal: Journal of Kufa - physics مجلة الكوفة للفيزياء ISSN: 20775830 Year: 2012 Volume: 4 Issue: 1 arabic Pages: 11-20
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

The influence of additive coal percentage and its grain size on compressive strength of building bricks were studied .Soil was used as a basic material and coal was added to it, with weight percentage of (0.1,0.2,0.5,1,3,5,10)% for three grain sizes. The samples were compressed in cubic shapes of 5cm edge, fired at (1100оC). Porosity , water absorption , lost weight and compressive strength were calculated for each sample. It was found that there is a close relationship between compressive strength and additive coal percentage and its grain size ,where compressive strength increases for low weight percentage (0.2-0.5)% and fine grain size (75-150) μm and the highest value of compressive strength was recorded with the range of (400kg.f/cm2). On the other hand compressive strength decreases with the additive coal and grain size increase where the samples of high percentage of weight (10%) and coarse grain size(300-600) μm has recorded the less value of compressive strength . So the obtained brick has a high quality of Porosity ,water absorption and compressive strength that the Iraqi standard of qualification No.(25) class A.

دُرسَ تأثير نسبة الفحم المضاف وحجم حبيباته في متانة إنضغاط الطابوق لعينات أستخدمت التربة Soil كمادة أساسوأضيف لها الفحم Coal بنسب وزنية هي: (10 , 5 ,3 ,1 , 0.5 , 0.2 , 0.1 )% ولثلاثة حجوم حبيبية , ثم كُبستالعينات بشكل مكعبات طول ضلع كل منها ) 5cm ( وحُرقت بدرجة (1100оC) .حُسبت المسامية ,إمتصاصية الماء,الوزن المفقود ومتانة الإنضغاط لكل عينة. وجد أن هناك علاقة وثيقة بين متانة الإنضغاط ونسبة الفحم المضاف وحجمحبيباته , إذ تزداد متانة الإنضغاط للنسب الوزنية الواطئة %) 2.0 2.0 ( وللحجم الحبيبي الناعم - (75-150 ) μmوسجلت أعلى قيمة لمتانة الإنضغاط بحدود 400Kg.f/cm2 . ومن جهة أخرى تتناقص متانة الإنضغاط بزيادة الحجمالحبيبي للفحم المضاف وسجلت العينات ذات النسب الوزنية العالية 10% والحجم الحبيبي الخشن (300-600) μm أقلقيم لمتانة الإنضغاط . تم الحصول على طابوقة تتفوق بمواصفاتها من حيث المسامية وإمتصاصية الماء ومتانة الإنضغاطعلى الطابوقة بالمواصفة العراقية رقم) 25 ( ذات الصنف أ .A

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

Arabic and English (1)


Year
From To Submit

2012 (2)