research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Pomegranate Peels as Biosorbent Material to Remove Heavy Metal Ions from Industerial Wastewater
استخدام قشور الرمان كمواد مازة لإزالة أيونات العناصر الثقيلة من مياه الفضلة الصناعية

Authors: S.M. Shartooh سفيان محمد شرتوح --- M.N.A. Al-Azzawi محمد نافع علي العزاوي --- S.A.K. Al-Hiyaly صديق أحمد قاسم الحيالي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2013 Volume: 54 Issue: 4 Pages: 823-831
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Pomegranate peels were used to remove zinc, chromium and nickel from industrial wastewater. Three forms of these peels (fresh, dried small pieces and powder) were tested under some environmental factors such as pH, temperature and contact time. The obtained results showed that these peels are capable of removing zinc, chromium and nickel ions at significant capacities. The powder of the peels had the highest capability in bioremoving all zinc, chromium and nickel ions while dried peels had the lowest capacity again for all metals under test. However, the highest capacities were found in a sequence of chromium, nickel and zinc. Furthermore, all these data were significantly (LSD peel forms = 2.761 mg/l, LSD metal ions = 1.756 mg/l) varied. In case of chromium, these figures were 69.7 ± 0.9 mg/l, 58.0 ± 2.4 mg/l and 49.7 ± 0.5 mg/l for powder, fresh and dried peels respectively. Regarding nickel ions, the data were 58.7 ± 1.1 mg/l for peel powder, 50.7 ± 2.0 mg/l for fresh peel and 42.0 ± 1.2 mg/l for dry peel. While for zinc ions, the biosorption capacity was 48.4 ± 2.2 mg/l, 39.4 ± 0.8 mg/l and 32.0 ± 1.6 mg/l for powder, fresh and dry peels respectively. However, some examined factors were found to have significant impacts upon bioremoval capacity of pomegranate peels such as pH, temperature, and contact time where best biosorption capacities were found at pH 4, with temperature 50 Cº and contact time of 1 hour. Regarding pH, the highest bioremoval ability was found at pH 4 for all heavy metals, but with the sequence of Cr, Ni, and Zn and the data were 68.1 ± 1.5 mg/l, 56.0 ± 0.5 mg/l and 47.88 ± 1.21 mg/l respectively. Similar pattern of bioremoval capacity was detected for temperature which was 50 Cº giving capacities of 72.0 ± 0.0 mg Cr/l, 60.0 ± 1.84 mg Ni/l and 54.0 ± 1.72 mg Zn/l. In case of contact time, these capacities were again similar to those of pH and temperature and found to be 76.0 ± 3.0 mg/l , 64.0 ± 1.82 mg/l and 60.0 ± 2.0 mg/l for Cr, Ni, and Zn respectively but at 1 hour contact time.

لقد استخدمت قشور الرمان في إزالة ايونات عناصر الخارصين ، الكروم و النيكل من مياه الفضلة الصناعية واختبرت ثلاث إشكال ( القشور الطرية ، الجافة ، مسحوق القشور) تحت ظروف بعض العوامل مثل الدالة الحامضية ، درجة الحرارة و زمن التلامس. تشير النتائج الى قدرة قشور الرمان على امتزاز ايونات هذه العناصر من مياه الفضلة الصناعية عند مستويات معنوية وان أفضل قدرة وجدت في حالة مسحوق القشور ثم القشور الطرية بينما كانت القشور الجافة اقل كفاءة. من جهة ثانية ، وجد أن أعلى التراكيز كانت لايون الكروم ثم النيكل و الخارصين. أن الفرق بين تراكيز العناصر الممتزة كانت واضحة ومعنوية بدلالة الفرق المعنوي الأصغر سواءً لأشكال القشور أو العناصر الممتزة ( ف م أ للقشور= 2.761 ملغم/ لتر وللعناصر = 1.756 ملغم / لتر). في حالة ايونات الكروم كانت قيم الامتزاز 69.7 ± 0.9 ملغم/ لتر ، 58.0 ± 2.4 ملغم / لتر لمسحوق القشور ، القشور الطرية و الجافة على التوالي. لايونات النيكل ، فان هذه القيم كانت 58.7 ± 1.1 ملغم / لتر لمسحوق القشور ، 50.7 ± 2.0 ملغم/ لتر للقشور الطرية و 42.0 ± 1.2 ملغم / لتر للجافة. في حالة عنصر الخارصين كانت قيم الامتزاز 48.4 ± 2.2 ، 39.4 ± 0.8 و 32.0 ± 1.6 ملغم / لتر للمسحوق والقشور الطرية و الجافة على التوالي. بالمقابل ، فان بعض العوامل التي تم تقييم تأثيراتها وجدت ذات تأثيرات معنوية على قابلية هذه المازات على امتزاز ايونات العناصر الثقيلة تحت الدراسة وفي ذات الوقت وجدت أن أفضل قيمة دالة حامضية كانت 4 وأفضل درجة حرارة هي 50 م º وزمن تلامس لمدة ساعة واحدة فقط حيث سجلت قدرة امتزاز بلغت 68.1 ± 1.5 ملغم/ لتر لايون الكروم و 56.0 ± 0.5 ملغم / لتر لايون النيكل عند درجة حامضية 4 وذات الترتيب من طاقة الامتزاز سجلت عند درجة حرارة 50 م º حيث كانت 72.0 ± 0.0 ملغم كروم/ لتر ، 60.0 ± 1.84 ملغم نيكل / لتر و 54.0 ± 1.72 ملغم خارصين / لتر . كذلك الحال لزمن التلامس حيث وجدت طاقة امتزاز 76.0 ± 30 ، 64.0 ± 1.82 و 60.0 ± 2.0 ملغم / لتر للكروم ، النيكل و الخارصين على التوالي.


Article
Bioadsorption of Heavy Metals From Industrial Wastewater Using Some Species of Bacteria
الادمصاص الحيوي للعناصر الثقيلة من مياه الفضلة الصناعية باستخدام بعض الانواع البكتيرية

Loading...
Loading...
Abstract

Three isolated bacteria were examined to remove heavy metals from the industrial wastewater of the Diala State Company of Electrical Industries, Diyala-Iraq. The isolated bacteria were identified as Pseudomonas aeruginosa, Escherichia coli and Sulfate Reducing Bacteria (SRB). The three isolates were used as an adsorption factor for different concentrations of Lead and Copper (100, 150, and 200 ppm.), in order to examine the adsorption efficiency of these isolates. In addition, the effect of three factors on heavy metals adsorption were examined; temperature (25, 30, and 37 ͦC), pH (3 and 4.5) and contact time (2 and 24 hrs). The results showed that the highest level of lead adsorption was obtained at 37 ͦC by E. coli, P, aerugenosa and SRB with percentage of 95, 95.3 and 99.7 % respectively, whereas, E. coli, P. Aerugenosa and SRB gave a copper adsorption percentage of (40.63, 50.51 and 80.57%) respectively at 37 ͦC. Moreover, E.coli showed different percentage of metal adsorption ranged from 6.4% to 95 % with lead concentration of 100 and 200 ppm at pH4.5 and for each of 2 and 24 hrs contact time, whereas, it exerts percentage of copper adsorption ranged from 3.5 % to 40.63 % at 100 and 200 ppm and pH value of 4.5 for similar contact time. P. aerugenosa was also shown to be involved in metal adsorption with percentage ranged from 1.39 % for lead concentration of 150 ppm to 97.9 % for 200ppm under pH of 3 and contact times of 2 and 24 hrs. Interestingly, SRB exhibits significant differences in metal absorption values ranged from 14.97 % for lead (100 ppm) to 99.32 % at 200 ppm with a pH value of 3 and contact times of 2 and 24 hrs and under different temperatures.

اختبرت ثلاثة أنواع من البكتريا المعزولة وهي Pseudomonas aeruginosaوEscherichia coli و Sulfate Reducing Bacteria. لازالة العناصر الثقيلة من مياة الفضلة الصناعية لشركة ديالى للصناعات الكهربائية, ديالى – العراق واستخدمت في المختبر كعامل امتزاز , كما استخدمت تراكيز مختلفة من الرصاص والنحاس100)و 150 و200) جزء بالمليون لاختبار كفاءة الامتزاز للبكتريا المعزولة. وبالإضافة إلى ذلك، تم اختبار تاثير ثلاث عوامل على امتزاز الرصاص والنحاس وهي الحرارة 25) و 30و 37) مº , ومستويات مختلفة من الأس الهيدروجيني (3و4.5 )، بالاضافة الى وقت الاتصال استخدمت فترتين ( 2 و 24 ) ساعة. تم الحصول على اعلى مستوى لامتزاز الرصاص وبالنسب 95% , 95.3% و 99.7% للبكتريا E.coli و P. aeruginosaو SRB عند37مᵒ على التوالي. بينما كانت نسب امتزاز النحاس 40.63% و % 50.51و %80.57 للبكتريا E.coli , P. aeruginosa و SRB. عند درجة حرارة 37مº, على التوالي. قد اظهرت E.coli نسب مختلفة من الامتزاز للمعادن تراوحت من 6.4% إلى 95% في تركيز الرصاص من100 و 200 جزء بالمليون وقيمة الاس الهيدروجيني 4.5 لكل من فترات الاتصال 2 و 24 ساعة على التوالي . في حين تراوح امتزاز النحاس من3.5% إلى %40.63 في 100 و 200 جزء في المليون في قيمة أس هيدروجيني 4.5 وخلال فترة اتصال2 و 24 ساعة , على التوالي . حققت P. aeruginosa امتزاز على النحو التالي: تراوح امتزاز الرصاص من 1.39٪ في التتركيز150 جزء في المليون إلى 97.9٪ في200 جزء في المليون عند قيمة الأس الهيدروجيني3 وبفترات اتصال 2 و 24 ساعه على التوالي. اظهرت SRB فعالية امتزاز اكبر من الانواع لاخرى من لبكتريا المستخدمة في الدراسة, وقد تراوح امتزاز الرصاص من 14.97% بتركيز 100 جزء من المليون وقيمة الأس الهيدروجيني ولفترة اتصال 24 ساعة إلى 99.32% في تركيز الرصاص200 جزء في المليون وقيمة الأس الهيدروجيني 3 وبفترة اتصال 2 ساعة. سجلت النتائج وجود فروق معنوية في درجات الحرارة عند استخدام بكتيريا SRB في امتزاز الرصاص والنحاس.


Article
عزل وتشخيص البكتريا المحللة للمركبات الفينولية من المياه

Author: سوزان كامران حسن حسن رحيم الشريفي جامعة بغداد/ كلية الزراعة – قسم علوم الاغذية
Journal: journal of the college of basic education مجلة كلية التربية الاساسية ISSN: 18157467 Year: 2016 Volume: 22 Issue: 96/ علمي Pages: 165-176
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Isolation and Identification of phenol degrading bacteria from waterAbstractSix phenol degrading bacteria were isolated from the industrial sewage of Al-Doura oil refiner and identified by the developed bacterial identification technique Vitek 2 system. Four of these isolates were identified as Pseudomonas fluorescens , one as Citrobacter freundii and Serratia liquefaciens . The better of phenol degrading Isolate Pseudomonas fluorescens SK was chosen as its total number was 262x105 c.f.u.ml when they were grown in mineral medium containing phenol as carbon source.

المقدمةيعد تلوث البيئة مشكلة من اكبر واخطر مشاكل العصر والذي شهد العالم خلاله تطورا كبيرا في جميع المستويات ومن أكثرها ضرراً على مستقبل الحياة على كوكب الارض ، ويعد التلوث المائي أحد المخاطر التي تهدد البيئة) 2). اذ ان الصناعة هي من اهم وانشط المصادر المسببة لتلوث المياه، ولاسيما الصناعات التي تستعمل وتطرح العناصر الثقيلة والمركبات السامة أذّ مما لا شك فيه ان هذه المواد ذات تأثيرات ضارة وسامة عندما تنتقل الى الكائنات الحية وتستقر في انسجتها (14) . وإن ما يعظم الحالة ويدعو الى الحذر والاهتمام بالموضوع هو كون العناصر الثقيلة والمركبات السامة لا تتحلل بفعل الاحياء المجهرية ولكن تتجمع ويزداد تركيزها تدريجيا وقد تخزن فى انسجة الكائنات الحية (التركيز الحياتي Bioconcentration) ، كما يمكن ان تنتقل الى مسافات بعيدة عن مصادر طرحها في الماء ومن ثم تاثيرها في الانسان عبر انتقالها عن طريق السلسلة الغذائية(26). ويعد الفينول والمركبات الفينولية من ملوثات المياه السامة ولزيادة طرح المياه الصناعية الملوثة بهذا المركب كان لابد من ايجاد طرائق كفؤة لازالة هذه الملوثات عن طريق استعمال انظمة مايكروبايولوجية لازالة المركبات السامة من المخلفات الصناعية ومن ثم طرحها الى الانهار (23).

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (2)

Arabic (1)


Year
From To Submit

2016 (2)

2013 (1)