research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Simulate the loss of energy in the X-ray in the magnesium and silicon
محاكاة فقدان طاقة الأشعة السينية في عنصري المغنسيوم والسليكون

Authors: Z.T.Ghaleb زهراء طالب غالب --- S.F.Mohammed سمين فاضل محمد --- A.M.Ghaleb عبد الهادي مردان غالب
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2015 Volume: 11 Issue: 1 Pages: 69-80
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

This paper includes the study of X-rays to simulate a range of energies (E = 5.5, 7,8,17.5,22.5) KeV in the elements (Mg, Si) and with different thickness., And compared the results obtained with the program (XCOM). Was calculated linear attenuation coefficients and mass of the linear relationship between the logarithm ( ln ), and the thickness chosen for the elements. Calculated and also all of the electronic density and the cross-sectional area of atomic materials mentioned above, Present research results they are compatible with the results computed within the program (XCOM).

يتضمن هذا البحث دراسة محاكاة الأشعة السينية لمدى من الطاقات KeV(E=5,7,8,17.5,22.5) في العناصر (Mg ,Si) وذات الأسماك المختلفة.وقورنت النتائج التي حصلنا عليها مع برنامج (XCOM ).ايضا تم حساب معاملات التوهين الخطي والكتلي من العلاقة الخطية بين لوغاريتم ( ) والسمك المختار للعناصر .وكذلك حسبت كل من الكثافة الكتروني (Electron density) والمساحة المقطع العرضي الذري لمواد المذكورة أعلاه,النتائج البحث الحالي كانت متوافقة مع النتائج المحسوبة ضمن برنامج (XCOM).


Article
Calculation of Atomic Cross section &Electron Density for (Tissue and Bone ) using Monte Carlo program
حساب مساحة المقطع العرضي الذري والكثافة الكترونية لـــ (الانسجة والعظام) باستخدام برنامج مونت كارلو

Author: Abdulhadi.M.Ghelab
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2016 Volume: 14 Issue: 1 Pages: 38-44
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

In the present work , calculated mass attenuation coefficients ,atomic cross section and electron density for these tissue and bone were theoretically calculated using monte carlo program within a range of energies of x-rays (16.5-17.5-21.5-24.5)keV .The attenuation coefficient of substances ,at any energy of x-ray photon ,is known to depends on the electron density and effective atomic number of the material .which makes it very sensitive to the index "x" .Several different values laying between) 0.5 - 2.5( step 0.5 have been suggested for the exponent "x".The results were compared with XCOM program .These theoretical values are found to be in agreement with the calculated from XCOM value .

في هذا البحث,حسبت معاملات التوهين الكتلية ـ المساحة المقطع العضي الذري وكذلك الكثافة الالكترونية للانسجة والعظام باستخدام برنـامج مونت كارلو ولمدى الطاقــــــات الاشعة السينية (16.5-17.5-21.5-24.5)keV.وتم فرض الاسماك المختلفة لمواد المذكوره اعلاه ,اظهرت النتائج ان المعامل التوهين يقل بزيادة الطاقة الاشعة السينية .وقورنت البيانات البحث الحالي مع برنامج (XCOM) (Version 3.1) وكانت هناك توافق جيد في الحسابات

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2016 (1)

2015 (1)