Effect of Curing methods on the Compressive Strength of concrete
تأثير طرق الإنضاج على مقاومة الانضغاط للخرسانة

Loading...
Loading...
Abstract

This paper is dedicated for studying the effect of curing methods on the compressive strength of concrete by using five methods of curing which are: the British method which is carried out by immersing the specimens in water starting after 24 hours of casting, then putting them in polyethylene bags- which are closed tightly- till the date of testing .The second method is carried out by covering specimens with burlap and sprinkling the specimens twice a day. The third method is carried out by immersing the specimens with water. The fourth method is carried out by sprinkling the specimens twice a day. And the last method is to paint the specimens with flint coating to prohibit the water from escaping by evaporation. The results showed that the British method is the best one for compressive strength values (36.66,31.26,25.83 MPa(, also the method of immersion in water has a close values to this method especially after 28 days. It has been noticed that the results of the fifth method have the smallest values and for all ages of curing (19.65,19.18,18.24 MPa).

يهدف هذا البحث إلى دراسة تأثير طرق الإنضاج على المقاومة الانضغاطية للخرسانة من خلال استخدام خمس طرق إنضاج و هي: الطريقة البريطانية و التي تشمل غمر النموذج بالماء بعد صبه باربع و عشرون ساعة ثم وضعه بأكياس البولي اثيلين المحكمة الغلق لحين الفحص ، طريقة التغطية بالخيش مع الرش بالماء مرتين يوميا، طريقة الغمر بالماء، طريقة الرش بالماء مرتين يوميا، وطريقة الطلاء بمادة الفلنكوت. أظهرت نتائج فحص المقاومة الانضغاطية لنماذج المكعبات بعمر21،7 و 28 يوم أن طريقة الإنضاج بأتباع المواصفة البريطانية سجلت اكبر قيم للمقاومة الانضغاطية حيث كانت النتائج (25,83،31,26,36, 36,66 ميكا باسكال) ولم تكن نتائج الفحص بطريقة الغمر بالماء مختلفة كثيرا عنها و خصوصا بعمر 28 يوم . و قد لوحظ ايضا بأن نتائج المقاومة الانضغاطية لطريقة الطلاء بمادة الفلنكوت هي الاقل و لكافة الأعمار (18,24, 19,18, 19,65 ميكا باسكال).


Article
Physical Properties and Compressive Strength of the Technical Plaster and Local Juss
الصفات الفيزيائية والمقاومة الانضغاطية للبلاستر الفني والجص المحلي

Loading...
Loading...
Abstract

Five physical properties (water/powder ratio, setting time, fineness, porosity and dendsity) and compressive strength were determined and compared for technical plaster and local juss.Data were monitored using a standard dental stone. The relationships between these properties were also studied. It was revealed that local juss has inferior properties compared with technical plaster. It has lower compressive strength; higher water/powder ratio; shorter setting time; larger grain size and higher porosity. There is an inverse relationship between compressive strength and the two properties water/powder ratio and porosity. There is a direct relationship between compressive strength and the two properties particle size and density. There is also a direct relationship between setting time and the two properties particle size and water/powder ratio.

تم دراسة خمس خواص فيزيائية وهى (نسبة الماء إلى المسحوق وزمن التجمد والنعومة والمسامية والكثافة) والمقاومة الانضغاطية لكل من البلاستر الفني والجص المحلي وتم استعمال حجر الأسنان كنموذج قياسي. وتم كذلك دراسة العلاقات بين هذه الصفات ووجد بأن للجص المحلي صفات متدنية مقارنة مع البلاستر الفني، حيث له مقاومة انضغاطية اقل ونسبة الماء الى المسحوق أعلى وزمن تجمد اقصر وحجم حبيبي اكبر ومسامية أعلى من البلاستر الفني. وأوضحت الدراسة وجود علاقة عكسية بين المقاومة الانضغاطية والصفتين نسبة الماء الى المسحوق والمسامية. وعلاقة طردية بين المقاومة الانضغاطية والصفتين الحجم الحبيبي والكثافة. وتبين ايضا وجود علاقة طردية بين زمن التجمد والصفتين الحجم الحبيبي ونسبة الماء الى المسحوق.


Article
Use of Alum and Polyelectrolyte Coagulants in Mixing Water in Concrete Bunkers Building or Construction
إستخدام مخثرات الشب والبولي ألكتروليت في ماء الخلط للخلطات الخرسانية المستخدمة في إنشاء السواتر

Author: Ako Rashed Hama آكو رشيد حمه
Journal: Sulaimania Journal for Engineering Sciences مجلة السليمانية للعلوم الهندسية ISSN: 24101699/24156655 Year: 2019 Volume: 6 Issue: 1 Pages: 11-28
Publisher: university of Sulaimania جامعة السليمانية

Loading...
Loading...
Abstract

This paper examines the possibility of using water treatment plant’s sludge [WTP] in mixing water in preparing high strength concrete bunkers. The two main chemical coagulants used in Dokan WTP 70 km southwest of Sulaimani city in Iraq, are alum and polyelectrolyte and they produce a coagulant’s sludge which settled at the end of sedimentation process on the bottom of the clarifier tanks. In this study, the two chemical coagulants alum and polyelectrolyte used as a concrete additives. Samples of the raw water taken from the inlets and have been tested continuously for a time period of 12 months during summer and winter seasons especially at the beginning of the stratification periods of Dokan Lake (source of the treatment plant). The tests included jar tests and turbidity of the samples, then determining the optimum quantity of each of alum and polyelectrolytes. So the maximum amount of the alum was 15mg/L while for polyelectrolyte was 10mg/L. Those two maximum high values of rates of alum and polyelectrolytes and their hybrid mixing rates have been used in preparation 7 concrete prototype bunkers with dimensions of 80cm x 80cm x 15cm with an admixture rates of 15mg/L alum, 15mg/L polyelectrolyte, 10mg/L alum, 10mg/L polyelectrolyte , 10mg/L alum with 5 mg/L polyelectrolyte, 5 mg/L alum with 5 mg/L polyelectrolyte and zero mg/L for both of them (blank). Two different types of tests have been performed for the prepared concrete bunkers; the in-lab compression tests for the cube samples of the prototypes concrete and the outdoor field shouting test for the prepared concrete bunker prototypes using 12.7 mm gun fire bullets and a shooting 100m from the target. Concrete compression laboratory tests have been conducted for 7,21and 28days aged concrete prototype bunkers while the depth, length and the diameter of the cracks and punching of the bullet hitting locations on the targeted prototype concrete bunker were measured. The results of this research reveals that adding alum along either in 15mg/l or 10 mg/ l doses in the three aged concrete 7,21,and 28 days will affect inversly on the concrete compaction strength by a (1 – 8)% while adding the other mensioned doses (polyelectrolyte along with different doses 10mg/l or 15 mg/l and a hybird doses of alum 10mg/l mixed with polyelectrolite 10mg/l ,will help in increasing the concrete compression strength of the concrete by 3.5% to 12%. Through out the tests its clearly appeared that the optimum coagulant in increasing the capacity of the concrete is polyelectrolyte and with a dosage of 15mg/l and it helps to increase the capacity of the concrete to 9% at 7days , 11.5 % at 21days and 13% at 28days from the age of the concrete .The results showed that the penetration depth for all the seven concrete bunker prototypes, evaluates each prototype performance via their penetration depths, because the penetration depth of the bullet is the most important variable in selecting the best performance concrete bunker prototype among all of them. The results also showed that the minimum penetration was 1.7 cm of polyelectrolyte used coagulant prototype of 15mg/L, and the maximum ratio about 2.2cm for the concrete banker prototype containing 15 mg/L of polyelectrolyte coagulant in mixing water of the concrete mixture used in it. Also the smallest diameter as a result of shooting test was 10 cm for this prototype while the largest diameter was 20 cm for the bunker prototype containing 10 mg/L of polyelectrolyte coagulant in mixing water of the mixture used in it.

تم في هذه الدراسة إستخدام المياه الغنية بمادتي الشب والبولي ألكتروليت اللتين هما من اكثر المخثرات شائعة الإستخدام في محطات التصفية كمحطة دوكان لتصفة مياه الإسالة والواقعة جنوب شرق مدينة السليمانية اذ تم إستخدامها كماء خلط في الخلطات الخرسانية عالية المقاومة والمستخدمة في إنشاء السواتر الخرسانية اذ تم إستخدام جرعات مختلفة من الشب والبولي ألكتروليت بالإعتماد على القيم القصوى للإستهلاك في المحطة خلال فترة زمنية مقدارها سنة اذ بلغت 15 ملغ/ لتر من الشب و 10 ملغ/لتر من البولي ألكتروليت. تم إنشاء سبعة نماذج من السواتر الخرسانية بأبعاد 80 سم x80 سم x 15 سم. كانت نسب الاضافة للمواد المخثرة الكيميائية الى ماء الخلط 10 و 15 ملغ/ لتر من شب لوحدهما ، 10 و 15 ملغ/لتر من البولي ألكتروليت لوحدهما ، و 10 ملغ/لتر من شب مع 5 ملغ/لتر من البولي ألكتروليت معا ، 5 ملغ/لتر من الشب مع 5 ملغ/لتر من البولي ألكتروليت معا وكما تم مقارنة الخلطات الحاوية على هذه النماذج من ماء الخلط مع خلطة مرجعية ذات ماء خلط إعتيادي ) غير حاوي على الشب او البولي اليكتوليت( . استخدم نوعان من الفحوصات لغرض معرفة مدى تأثر مقاومة الخرسانة عند إضافة تلك المواد وهما فحص مقاومة الإنضغاط للمكعبات والفحص الموقعي بإستخدام الرمي من رشاش آلي ذو ذخيرة حية بعيار 12.7 ملم من موقع ثابت وعن مسافة ثابتة تبلغ 100 م. بينت النتائج بان إستخدام الشب في ماء الخلط تقلل من مقاومة الخرسانة للانضغاط بنسبة تراوحت من 1 ٪ الى 8 ٪ في المقابل لوحظ ان إستخدام البولي اليكتوليت بشكل منفرد في ماء الخلط او بشكل مركب مع الشب ادى الى زيادة مقاومة الإنضغاظ بنسبة تراوحت من ) 3.5 الى 13 ٪) اذ عند إضافة 15 ملغ/لتر من البولي اليكتروليت الى ماء الخلط , لوحظ بان نسبة الزيادة في مقاومة الإنضغلط بلغت ) 13 ، 11.5 و 9(٪ عند الأعمار ) 7 ، 21 و 28 ( يوما على التوالي كما أن نسب الزيادة هذه تمثل النسب الأعلى مقارنة بالبقية الخلطات.أظهرت نتائج ألرمي الحقلي على نماذج السواتر والتي تعتبر دليل آخر لمعرفة مدى تأثر النماذج بالمواد المخثرة الكيميائية المضافة كانت أقل قيمة مقاسة لعمق إختراق الذخيرة في النماذج الخرسانية بلغت 1.7 سم للنموذج التي يحتوي على 15 ملغ/لتر من البولي اليكترويت أما أعلى قيمة للعمق كانت 2.2 سم. كما ان أكبر قطر متأثر بالذخيرة كان 18 سم للنموذج الذي يحتوي على 15 ملغ/لتر من البولي أليكتروليت أما أضغرها فقد بلغ 10 سم عند النموذج الذي يحتوى على 15 ملغ/لتر من مادة الشب. بذلك يمكن القول بأن المواد المخثرة الكيمياوية تزيد من مقاومة الإنضغاط للخرسانة المستخدمة في السواتر الخرسانية.