research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
ELECTROLYTIC PRODUCTION OF POTASSIUM BROMATE USING GRAPHITE SUBSTRATE LEAD DIOXIDE (GSLD) ANODE
الإنتاج الألكتروليتي لبرومات البوتاسيوم باستخدام الكرافيت المغطى بثاني أوكسيد الرصاص( (GSLD كأنود

Author: AHMED DAHAM WIHEEB
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2005 Volume: 12 Issue: 4 Pages: 124-142
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Graphite substrate lead dioxide (GSLD) was used to make a suitable anode for the production of potassium bromate from potassium bromide. This anode has been used successfully in the presence of certain addition agents (like potassium dichromate) as a replacement for graphite anode. A laboratory electrolytic cell was designed to produce of potassium bromate. A solution of potassium bromide (240 g/l) and potassium bromate (20 g/l) is electrolyzed in batch wise. The effect of anodic current density, temperature, and starting PH of electrolyte on the current efficiency of bromate formation was studied. High current efficiency of about 92 – 94 % was obtained by using (GSLD).

يستخدم الكرافيت المغطى بثاني أوكسيد الرصاص ( (GSLDكأنود لإنتاج برومات البوتاسيوم من بروميد البوتاسيوم بنجاح عند توفر العوامل المضافة (مثل دايكرومات البوتاسيوم) كبديل لأنود الكرافيت. وقد تم تصميم خلية الكتروليتية لأجراء التجارب والتي تتضمن التحليل الكهربائي لمحلول من بروميد البوتاسيوم بتركيز (240 غم / لتر) وبرومات البوتاسيوم بتركيز (20 غم / لتر) بالطريقة الدفعية ودراسة تأثير كثافة تيار الأنود ودرجة الحرارة ودرجة الحموضة البدائية للمحلول على كفاءة التيار لتكوين البرومات . أعلى كفاءة تيار تم الحصول عليها بحدود 92 – 94 % باستخدام (GSLD ) كأنود.


Article
Spectrophotometric Determination of (Atorvastatin Ca) in Pure form and in the Pharmaceutical Formulations
التقدير الطيفي لـ (أتورفاستاتين الكالسيوم) بشكله النقي وفي مستحضراته الصيدلانية

Author: Qabas N. Rashid قبس ناجي رشيد
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2017 Volume: 13 Issue: 4 - part 2 Pages: 167-185
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Simple, sensitive and rapid two methods for determination of Atorvastatin Calcium (Atv) in both pure form and pharmaceutical formulations. The first method was based on the oxidation of the studied drug in presence of acidic medium by a known excess of (Potassium bromide: Potassium bromate) (KBr:KBrO3) as an oxidizing agent and subsequent determination of unreacted oxidant by reacting it with Crystal Violet (CV) dye [4 [bis [4 (dimethylamino) phenyl] methylidene] cyclohexa-2,5-dien-1-ylidene]-dimethylazanium;chloride to produce blue at λmax. 594 nm. The second method involved determination of (Atv) using Chromogenic reagent Sodium 1,2-naphthoquine- 4-sulfonate (NQS) as reagent in an alkaline medium (pH 11.5) to form an orange product at λmax. 456nm, and the linearity range was found to be (10-100)µg/mL and (20-80)µg/mL respectively. With molar absorptivity 70.708×104 L/mol.cm and 20.565×103 L/mol.cm, correlation coefficient 0.9992 and 0.9977 and the limit of detection and limit of quantification (0.0178 µg/mL, 0.054 µg/mL) and (0.059 µg/mL, 0.179 µg/mL) respectively. The two methods were successfully applied for the determination of (Atv) in tablet formulation.

استُخدمت طريقتين بسيطة وحساسة وسريعة لتقدير المركب الدوائي اتورفاستاتين الكالسيوم (Atv) بشكله النقي وفي مستحضراته الصيدلانية. اعتمدت الطريقة [I] على أكسدة (Atv) في الوسط الحامضي باستخدام عامل مؤكسد (بروميد البوتاسيوم:برومات البوتاسيوم) (KBr:KBrO3) يليها اضافة صبغة البنفسج البلوري Crystal Violet (CV) [4- [bis[4-(dimethylamino)phenyl]methylidene]cyclohexa-2,5-dien-1-ylidene]-dimethylazanium;chloride والتي تتفاعل مع المتبقي من العامل المؤكسد ليتكون ناتج أزرق والذي أعطى أعلى قيمة امتصاص عند طول موجي 594 نانومتر، أما الطريقة [II] فتضمنت تقدير (Atv) باستخدام الكاشف الكروموجيني صوديوم 2،1- نفثوكينون-4-سلفونيت في الوسط القاعدي وعند أس هيدروجيني (pH 11.5) لتكوين ناتج برتقالي والذي أعطى أعلى امتصاص عند طول موجي 456 نانومتر، ومدى الخطية كان عند (10-100) مكغم/مل و(20-80) مكغم/مل للطريقتين على التوالي، وعند امتصاصية مولارية ×70.708104 لتر/مول.سم و×41.2347104 لتر/مول.سم، ومعامل ارتباط 0.9992 و0.9977، وكان حد الكشف وحد الكمية (0.0178 مكغم/مل، 0.054 مكغم/مل) و(0.059 مكغم/مل، 0.179 مكغم/مل) للطريقتين على التوالي، طبقت الطريقتان بنجاح في تقدير (Atv) في المستحضرات الصيدلانية على شكل أقراص.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)


Year
From To Submit

2017 (1)

2005 (1)